INTEX CS2220 Krystal Clear Saltwater System Owner’s Manual
- June 6, 2024
- INTEX
Table of Contents
- PARTS REFERENCE
- PRODUCT SPECIFICATIONS
- SETUP INSTRUCTIONS
- SALT & POOL WATER VOLUMES
- INTEX POOLS SALT TABLE
- INTEX POOLS CYANURIC ACID TABLE
- INTEX POOLS OPERATING TIMETABLE (WITH CYANURIC ACID)
- IMPORTANT
- SALT CALCULATION FORMULA FOR ALL POOLS
- SALT TABLE FOR COMMON NON-INTEX POOLS
- CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS
- OPERATING TIMETABLE FOR COMMON NON-INTEX POOLS (WITH CYANURIC ACID)
- OPERATION INSTRUCTIONS
- LED CODE CHART
- SALTWATER SYSTEM STATIONARY MOUNTING
- MAINTENANCE
- POOL MAINTENANCE & CHEMICAL DEFINITIONS
- TROUBLESHOOTING GUIDE
- LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QS 200
Krystal Clear™Saltwater System
Certified Model Number CS2220
220 – 240 V~, 50/60 Hz
For illustrative purposes only.
IMPORTANT SAFETY RULES
Please read, understand, and follow all instructions carefully before
installing and using this product. keep for future reference.
Don’t forget to try these other fine Intex products: pools, pool accessories, inflatable pools, in-home toys, airbeds, and boats available at fine retailers or visit our website. Due to a policy of continuous product improvement, Intex reserves the right to change specifications and appearance, which may result in updates to the instruction manual without notice.
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and
Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
- Always supervise children and those with disabilities.
- Children must stay away from this product and electrical cord(s).
- Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Assembly and disassembly by adults only.
- The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA.
- Always unplug this product from the electrical outlet before removing, cleaning, servicing, or making any adjustments to the product.
- Do not bury the electrical cord. Locate the cord where it will not be damaged by the lawnmowers, hedge trimmers, and other equipment.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
- To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors, or converter plugs to connect the unit to the electric supply; provide a properly located outlet.
- Do not attempt to plug in or unplug this product while standing in water or when your hands are wet.
- Keep this product more than 2m away from the pool.
- Keep the plug of this product more than 3.5m away from the pool.
- Position this product away from the pool, so as to prevent children from climbing on it and accessing the pool.
- This product is for use with storable pools only. Do not use with permanently installed pools. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original configuration.
- The appliance is intended only for household use.
- This product is intended to be used only for the purposes described in the manual!
- For all the information pertaining to the installation, cleaning, and maintenance, please refer to the below paragraphs of the manual.
- In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY DAMAGE, ELECTRIC
SHOCK, ENTANGLEMENT, OR OTHER SERIOUS INJURY OR DEATH.
These product warnings, instructions, and safety rules provided with the
product represent some common risks of water recreation devices and do not
cover all instances of risk and danger. Please use common sense and good
judgment when enjoying any water activity. For portable Above-Ground-Pools
only
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts.
NOTE: Drawings for illustration purposes only. The actual product may vary. Not to scale. No tools are required for the assembly.
REF. NO. | DESCRIPTION | QTY. | SPARE PART NO. |
---|---|---|---|
1 | CONTROL STATION | 1 | 13092 |
2 | CONNECTOR HOSE | 1 | 11873 |
3 | HOSE CLAMP | 2 | 11489 |
4 | CELL HOUSING O-RING | 2 | 12947 |
5 | CELL HOUSING | 1 | 13088 |
6 | TITANIUM ELECTRODE O-RING | 1 | 13094 |
7 | TITANIUM ELECTRODE | 1 | 13093 |
8 | ELECTROLYTIC CELL NUT | 1 | 13095 |
9 | TEST STRIPS | 1 | 19635 |
PRODUCT SPECIFICATIONS
Certified Model Number: | CS2220 |
---|---|
Wattage: | 20 W |
Ideal Salt Level: | 3000 ppm (parts per million) |
Maximum Chlorine Output/hour: | 2 grams/hour |
Filter pump minimum and maximum flow rate: | 300 gallons/hour (1136 |
liters/hour) /1000 gallons/hour (3785 liters/hour)
Limited Warranty:| see “Limited Warranty”
For pools and filter pumps with 1-¼” (32mm) hose connection fittings.
SETUP INSTRUCTIONS
IMPORTANT
- The Saltwater System requires a separate fi later pump [300~1000 gph (1136~3785 lph)] to drive the water and function properly.
- The Saltwater System must be installed as the last piece of pool equipment in the water return line to the pool as displayed below. This location extends the life of the titanium plates.
- Remove any large debris and particles such as leaves, sand, insects, and bugs from the pool water fi first.
-
Assemble the above-ground pool (AGP) and its fi later pump according to their installation instructions.
-
Take the Saltwater System and its accessories out of the packaging.
-
Place the Saltwater System in line after the fi later pump.
-
Connect the connector hose (2) to the Saltwater System inlet with a hose clamp (3).
-
Go directly to step 6 if your pool is empty. If your above-ground pool is fi filled with water, unscrew the strainer grids from the strainer connectors and insert the black hat-like plugs into the connectors, before installing the saltwater pool system.
-
Disconnect the water return hose from the fi later pump connection and connect it to the Saltwater System outlet.
-
Connect the connector hose (2) to the fi later pump outlet connection with a hose clamp (3).
Tighten securely. -
Remove the black hat-like plugs that prevent water from fl owing out of the pool. Now, return the strainer grids to the strainer connectors.
SALT & POOL WATER VOLUMES
-
Which kind of salt to use:
For use within the European Union, salt must be from an authorized salt supplier registered with the European Chemicals Agency (ECHA) – visit echa.europa.eu. *
Use only Sodium Chloride Salts
Use only sodium chloride (NaCl) salt that is at least 99.8% pure. It is also acceptable to use water conditioning salt pellets (the compressed forms of evaporated salt). However, it will take a longer time for them to dissolve. Do not use iodized or yellow (yellow prussiate of soda) colored salt. Salt is added to the pool water and the electrolytic cell uses the salt to create chlorine. The purer the salt the better the performance of the electrolytic cell. -
Optimum Salt Levels
The ideal salt level in the pool water is between 2500-3500 ppm (parts per million). The optimal level is 3000 ppm.
A too low salt level will reduce the efficiency of the Saltwater System and result in low chlorine production. A high salt level may generate a salty taste in the pool water (this may occur at a salt level above 3500-4000ppm). The too-high salt level may damage the power supply and cause corrosion to the pool metal fixtures and accessories. The Salt Table page of this manual shows the correct dosage of salt needed. -
Adding Salt
- Switch the fi latter pump on to start the water circulation.
- Keep the Saltwater System turned off.
- Determine the amount of salt to be added (see “Salt Table”).
- Evenly spread the proper amount of salt around the inside perimeter of the pool.
- Avoid clogging the fi later. Do not add salt through the skimmer.
- Brush the pool bottom to speed up the dissolving process. Do not allow the salt to pile up on the bottom of the pool. Run the fi later pump for 24 consecutive hours to thoroughly dissolve the salt.
- After 24 hours and if all the salt is dissolved, turn on the Saltwater System, press code “00” fl ashing, and set the saltwater pool system to desired operating time (see “Operating Time Table”).
-
Removing Salt
If too much salt has been added, the unit will beep and display “Code 92” (see “Alarm Codes”). You will need to lower the salt concentration. The only way to do so is to partially drain the pool and refill it with fresh water. Drain and refill approximately 20% of the pool’s water until the “Code 92” disappears. -
Pool Volume Calculation
Types of Pool| Gallons (pool size in feet)| Cubic Meters (pool
size in meters)
---|---|---
Rectangular| Length x Width x Average Depth x 7.5| Length x Width x
Average Depth
Circular| Length x Width x Average Depth x 5.9| Length x Width x Average
Depth x 0.79
Oval| Length x Width x Average Depth x 6.0| Length x Width x Average
Depth x 0.80
- The European Biocidal Products Regulation (BPR, Regulation (EU) 528/2012) requires that salt (sodium chloride) used as a precursor for on-site generation of active chlorine by electrolysis must be registered by the salt supplier with the European Chemicals Agency (ECHA), and such supplier must be included on ECHA’s list of authorized suppliers (Article 95 list).
INTEX POOLS SALT TABLE
This table shows the amount of salt needed to achieve and maintain the optimal 3000 ppm salt level.
Pool Size
| Water Capacity (Calculated at 90% for Frame Pool and 80% for Easy Set & Oval Pool)| Salt Needed for Startup
3.0g/L (3000ppm)
| Salt Needed when Low Salt Detected (CODE “91”)
---|---|---|---
(Gals)| (Liters)| (Lbs)| (Kgs)| (Lbs)| (Kgs)
INTEX ABOVE GROUND POOLS (agps)
EASY SET® POOL
| 244cmx61cm (8’x24”)| 513| 1942| 13| 6| 5| 2
244cmx76cm (8’x30″)| 639| 2419| 16| 7| 5| 2
305cmx61cm (10’x24”)| 813| 3077| 20| 9| 7| 3
305cmx76cm (10’x30″)| 1018| 3853| 25| 12| 9| 4
366cmx76cm (12’x30″)| 1485| 5621| 37| 17| 13| 6
396cmx84cm (13’x33″)| 1926| 7290| 48| 22| 17| 8
METAL FRAME POOL| 244cmx51cm (8’x20”)| 483| 1828| 13| 6| 5| 2
305cmx76cm (10’x30″)| 1185| 4485| 30| 13| 9| 4
366cmx76cm (12’x30″)| 1718| 6503| 43| 20| 15| 7
PRISM FRAME TM POOL| 305cmx76cm (10’x30″)| 1185| 4485| 30| 13| 10| 5
366cmx76cm (12’x30″)| 1718| 6503| 43| 20| 15| 7
PRISM FRAME TM RECT. POOL| 300cmx175cmx80cm (9’10″x5’9″x31½”)| 935| 3539|
23| 11| 7| 3
400cmx200cmx100cm (13’1½”x6’6¾”x39½”)| 1806| 6836| 45| 21| 15| 7
SMALL RECT. FRAME POOL| 220cmx150cmx60cm (7’2⅝”x4’11″x23⅝”)| 439| 1662|
11| 5| 3| 1
260cmx160cmx65cm (8’6½”x5’3″x25⅝”)| 603| 2282| 16| 7| 5| 2
300cmx200cmx75cm (9’10″x6’6¾”x29½”)| 1013| 3834| 25| 12| 9| 4
450cmx220cmx84cm (14’9¼”x7’2⅝”x33″)| 1883| 7127| 48| 22| 17| 8
INTEX POOLS CYANURIC ACID TABLE
Cyanuric acid is a chemical that reduces the loss of chlorine in water due to ultraviolet rays. To maintain the pool water clear and clean, and to maximize the performance of the device, add cyanuric acid to the pool. We recommend that the cyanuric acid level be maintained at approximately 0.35% of the salt, i.e. 100 Lbs (45 Kgs) salt x 0.35% =0.35 Lbs (0.16 Kgs) cyanuric acid.
Pool Size
| Water Capacity (Calculated at 90% for Frame Pool and 80% for Easy Set & Oval Pool)| Cyanuric Acid Needed for Startup
0.01g/L (10ppm)
---|---|---
(Gals)| (Liters)| (oz)| (g)
INTEX ABOVE GROUND POOLS (agps)
EASY SET® POOL| 244cmx61cm (8’x24”)| 513| 1942| 0.7| 19
244cmx76cm (8’x30″)| 639| 2419| 0.9| 25
305cmx61cm (10’x24”)| 813| 3077| 1.1| 31
305cmx76cm (10’x30″)| 1018| 3853| 1.4| 39
366cmx76cm (12’x30″)| 1485| 5621| 2.0| 56
396cmx84cm (13’x33″)| 1926| 7290| 2.6| 73
METAL FRAME POOL| 244cmx51cm (8’x20”)| 483| 1828| 0.7| 19
305cmx76cm (10’x30″)| 1185| 4485| 1.6| 45
366cmx76cm (12’x30″)| 1718| 6503| 2.3| 65
PRISM FRAME TM POOL| 305cmx76cm (10’x30″)| 1185| 4485| 1.6| 45
366cmx76cm (12’x30″)| 1718| 6503| 2.3| 65
PRISM FRAME TM RECT. POOL| 300cmx175cmx80cm (9’10″x5’9″x31½”)| 935| 3539|
1.3| 35
400cmx200cmx100cm (13’1½”x6’6¾”x39½”)| 1806| 6836| 2.4| 68
SMALL RECT. FRAME POOL| 220cmx150cmx60cm (7’2⅝”x4’11″x23⅝”)| 439| 1662|
0.6| 17
260cmx160cmx65cm (8’6½”x5’3″x25⅝”)| 603| 2282| 0.8| 23
300cmx200cmx75cm (9’10″x6’6¾”x29½”)| 1013| 3834| 1.4| 39
450cmx220cmx84cm (14’9¼”x7’2⅝”x33″)| 1883| 7127| 2.5| 71
INTEX POOLS OPERATING TIMETABLE (WITH CYANURIC ACID)
Pool Size| Water Capacity (Calculated at 90% for Frame Pool and 80%
for Easy Set & Oval Pool)| Operating Time (hours) at different
ambient/air temperatures| Intex Filter pump Operating Time (hours)
---|---|---|---
(Gals)| (Liters)| 10 – 19°C
(50 – 66°F)
| 20 – 28°C
(68 – 82°F)
| 29 – 36°C
(84 – 97°F)
INTEX ABOVE GROUND POOLS (AGP’s)
EASY SET® POOL| 244cmx61cm (8’x24”)| 513| 1942| 2| 2| 2| 3
244cmx76cm (8’x30″)| 639| 2419| 2| 2| 2| 3
305cmx61cm (10’x24”)| 813| 3077| 3| 3| 3| 4
305cmx76cm (10’x30″)| 1018| 3853| 4| 4| 4| 5
366cmx76cm (12’x30″)| 1485| 5621| 5| 5| 5| 6
396cmx84cm (13’x33″)| 1926| 7290| 7| 7| 7| 8
METAL FRAME POOL| 244cmx51cm (8’x20”)| 483| 1828| 2| 2| 2| 3
305cmx76cm (10’x30″)| 1185| 4485| 4| 4| 4| 5
366cmx76cm (12’x30″)| 1718| 6503| 6| 6| 6| 7
PRISM FRAME TM POOL| 305cmx76cm (10’x30″)| 1185| 4485| 4| 4| 4| 5
366cmx76cm (12’x30″)| 1718| 6503| 6| 6| 6| 7
PRISM FRAME TM RECT. POOL| 300cmx175cmx80cm (9’10″x5’9″x31½”)| 935| 3539|
3| 3| 4| 5
400cmx200cmx100cm (13’1½”x6’6¾”x39½”)| 1806| 6836| 6| 6| 7| 8
SMALL RECT. FRAME POOL| 220cmx150cmx60cm (7’2⅝”x4’11″x23⅝”)| 439| 1662|
1| 2| 2| 3
260cmx160cmx65cm (8’6½”x5’3″x25⅝”)| 603| 2282| 2| 2| 2| 3
300cmx200cmx75cm (9’10″x6’6¾”x29½”)| 1013| 3834| 4| 4| 4| 5
450cmx220cmx84cm (14’9¼”x7’2⅝”x33″)| 1883| 7127| 7| 7| 7| 8
IMPORTANT
The filter pump running time should be 1 hour longer than the required operating time of the Saltwater System.
NOTE: If an Intex fi later pump has a timer on the GFCI, the maximum run time is 10 hours. The timer will need to be manually reset in order to extend the operating time.
SALT CALCULATION FORMULA FOR ALL POOLS
Salt Needed for Startup (Lbs)| Salt Needed for Startup (Kgs)|
Salt Needed when Low Salt Detected (Lbs)| Salt Needed when Low Salt
Detected (Kgs)
---|---|---|---
Water Capacity (Gals) x 0.025| Water Capacity (Liters) x 0.003| Water Capacity
(Gals) x 0.0067| Water Capacity (Liters) x 0.0008
SALT TABLE FOR COMMON NON-INTEX POOLS
Water Capacity| Salt Needed for Startup| Salt Needed when Low
Salt Detected (CODE “91”)
---|---|---
(Gals)| (Liters)| (Lbs)| (Kgs)| (Lbs)| (Kgs)
500| 1893| 13| 6| 5| 2
750| 2839| 20| 9| 7| 3
1000| 3785| 25| 11| 8| 4
1250| 4731| 31| 14| 11| 5
1500| 5678| 38| 17| 13| 6
1750| 6624| 44| 20| 15| 7
2000| 7570| 50| 23| 17| 8
2200| 8327| 55| 25| 20| 9
CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS
Water Capacity | Cyanuric Acid Needed for Startup 0.01g/L (10ppm) |
---|---|
(Gals) | (Liters) |
500 | 1893 |
750 | 2839 |
1000 | 3785 |
1250 | 4731 |
1500 | 5678 |
1750 | 6624 |
2000 | 7570 |
2200 | 8327 |
OPERATING TIMETABLE FOR COMMON NON-INTEX POOLS (WITH CYANURIC ACID)
Water Capacity| Operating Time (hours) at different ambient/air
temperatures| Recommend Filter pump Operating Time (hours)
---|---|---
(Gals)| (Liters)| 10 – 19°C (50 – 66°F)| 20 – 28
°C (68 – 82 °F)| 29 – 36°C (84 – 97°F)
500| 1893| 2| 2| 2| 3
750| 2839| 3| 3| 3| 4
1000| 3785| 4| 4| 4| 5
1250| 4731| 4| 5| 5| 6
1500| 5678| 5| 5| 6| 7
1750| 6624| 6| 6| 6| 7
2000| 7570| 7| 7| 7| 8
2200| 8327| 8| 8| 8| 9
OPERATION INSTRUCTIONS
-
Turn on the filter pump.
-
Startup the unit:
Plug the power cord into the electrical outlet and test the household socket GFCI (circuit breaker). Press button. Flashing code “00” appears on the electronic control station’s LED, indicating that the unit is ready to be programmed. -
Set operating hours for the Saltwater system:
With code “00” flashing, press button to set the desired operating hours. See the “Operating Time Table” for the required operating hours related to each pool size. Pressing will increase the time from 01 to 12 hours maximum. If you have selected too many hours keep pressing to repeat the cycle. The built- in timer will now activate your Saltwater System, at the same time each day, for the number of hours you have set.
NOTE: The Saltwater System will not operate if the filter pump is not operating. Make sure to program your filter pump (or start it manually) for operation beginning 5 minutes before the saltwater system and finishing 15 minutes after the saltwater system. -
Lock keypad controls :
With the desired hour value showing, press the button. A green “WORKING” indicator on the control panel will light up within a few seconds to indicate that the saltwater system has started sodium hypochlorite production, the LED will display the remaining chlorinator hours until it’s finished. Locking the control buttons into this setting prevents unauthorized changing of the operating cycle.
NOTE: If you forget to lock the keypad controls, the system will automatically lock it and start working 10 seconds later. -
Readjust operating time if necessar y:
The operating hours can be re-adjusted if necessary. Press the button and the current programmed time will flash. Repeat steps 3 to 4. -
Stand-by/power saving mode:
• When the cycle ends, the green “SLEEP” indicator on the control panel lights up and the LED display flashes “93”. The system is now in Stand-By mode. After a while, it shuts down and sets itself in a Power Saving mode. The system will automatically turn itself back on in 24 hours, starting its daily cycle of sodium hypochlorite production.
• The “SLEEP” indicator stays on, while the system is in the Power Saving mode. The LED display, however, goes blank after 5 minutes. Press any button ( or ) to view the last LED code.
LED CODE CHART
LED Reading | Definitions |
---|---|
00 | Stand-By Mode (Start-up) |
01 | Minimum Operating Hour (1-hour remaining) |
02 – 11 | Operating Hours (2 – 11 hours remaining) |
12 | Maximum Operating Hours (12 hours remaining) |
90 | Alarm Code (Low Pump Flow / No Flow) |
91 | Alarm Code (Low Salt Level) |
92 | Alarm Code (High Salt Level) |
93 | Stand-By Mode (Operating Process finished) |
“BLANK” | No Power or “Power Saving Mode” waiting to start the next Saltwater |
System cycle.
IMPORTANT
When Code “90” alarm is shown, ensure the timer of the filter pump is set one
(1) hour longer than the Saltwater System.
If the filter pump does not have a built-in timer, the filter pump needs to be
turned on/off manually every day.
SALTWATER SYSTEM STATIONARY MOUNTING
Some countries, especially in the European community, require the product to
be secured to the ground or to a base in a permanently upright position. Check
with your local authorities to determine if there is a regulation in your area
regarding above-the-ground swimming pool fi later pumps. If yes, then the
product can be mounted to a platform using the two holes located in the base.
See the drawing below.
The product can be mounted on a cement base or onto a wooden platform to
prevent accidental tipping. The total assembly must exceed 18kg.
- The mounting holes are 6.4 mm in diameter and spaced 52 mm apart.
- Use two bolts and locknuts with a maximum of 6.4 mm in diameter.
MAINTENANCE
IMPORTANT
Unplug the power cord before cleaning your system. Also, insert the black hat-
like plugs in the strainer opening to prevent water spillage. After completing
all maintenance tasks, you must plug the power cord back in and remove the
plugs.
Titanium Electrode Cleaning
The titanium electrode has a self-cleaning function incorporated into the
electronic control’s programming. In most cases, this self-cleaning action
will keep the electrode working at optimum effi science. If the pool water is
hard (high mineral content) the electrode may require periodic manual
cleaning. To maintain maximum performance, we recommend that you open and
visually inspect the titanium electrode (7) monthly. The following steps
provide instructions on how to clean your cell.
Inspection and cleaning:
-
Switch off the unit, unplug the power cord from the electrical socket.
-
To prevent water from fl owing out of the pool, unscrew the strainer grids from the strainer connectors and insert the hat-like plugs into the strainer connectors.
-
Disconnect the 2 hoses from the Saltwater System (see drawings 1~3).
-
Unscrew the titanium electrode plug collar, and disconnect the plug from the titanium electrode (7) ( see drawing 4 ).
-
Unscrew the cell nut, and remove the titanium electrode from the cell housing (see drawing 5).
-
Place the titanium electrode in a container and pour kitchen-grade vinegar into the container until the titanium electrode is immersed. Soak for 1 hour and then fluse with a
high-pressure garden hose ( see drawing 6 ). -
Reverse steps 3, 4, 5, and 6 to reconnect the electrolytic cell.
INTEX® TEST STRIPS (PACKED WITH THE PRODUCT)
The Test Strips can test the “Free Chlorine”, “pH”, “Calcium Hardness” and “Total Alkalinity” levels at the same time. We recommend that you test the water chemistry weekly, and maintain the chlorine concentration at 1.0-3.0 ppm.
Directions and Use
- Dip the entire strip into the water and remove immediately.
- Hold the strip level for 15 seconds. Do not shake excess water from the strip.
- Now compare the strip pad to the color chart on the packaging label. If necessary, adjust the chemical level in the pool water. It is very important, to use the proper technique when testing the water’s chemical level. Read and follow the written strip instructions carefully.
LONG TERM STORAGE
- Disconnect the power cord from the electrical outlet.
- After the pool is completely empty, disconnect the Saltwater System from the hoses by reversing the installation instructions.
- Air-dry the unit before you store it. This might be a good time to visually inspect and clean the electrolytic cell.
- Store the unit and accessories in a dry place. The temperature should be controlled, between 32 degrees Fahrenheit (0 degrees Celsius) and 97 degrees Fahrenheit (36 degrees Celsius).
- The original package can be used for storage.
POOL MAINTENANCE & CHEMICAL DEFINITIONS
Preferred Water Chemistry Reading
| Minimum| Ideal| Maximum
Free Chlorine| 0| 1.0 – 3.0 ppm| 5.0 ppm
Combined Chlorine| 0| 0 ppm| 0.2 ppm
pH| 7.2| 7.4 – 7.6| 7.8
Total Alkalinity| 40 ppm| 80 ppm| 120 ppm
Calcium Hardness| 50 ppm| 100 – 250 ppm| 350 ppm
Stabilizer (Cyanuric Acid)| 10 ppm| 10 – 30 ppm| 30 ppm
Free Chlorine – Is the chlorine residual present in pool water.
Combined Chlorine – Is formed by the reaction of free chlorine with
ammonia wastes. The result if too high – Sharp chlorinous odor, eye
irritation.
pH – A value that indicates how acidic or basic a solution is.
Result if too low – Corroded metals, eye & skin irritation, destruction of
total alkalinity.
Result if too high – Scale formation, cloudy water, shorter filter runs, eye &
skin irritation, poor chlorine efficiency.
Total Alkalinity – indicates the degree of the water’s resistance to
change in pH.
It determines the speed and ease of pH change, so always adjust total
alkalinity before adjusting the pH level.
The result if too low – Corroded metals, eye & skin irritation. Low alkalinity
will cause the pH to be unstable. Any chemical added to the water will have an
effect on pH. The result is too high – Scale formation, cloudy water, eye &
skin irritation, poor chlorine efficiency.
Calcium Hardness – This refers to the amount of calcium and
magnesium dissolved in the water.
Result if too high – Eye & skin irritation, difficulty balancing water, and poor chlorine efficiency. The scale will form and will cause the water to become cloudy.
Stabilizer – Stabilizers extend the life of chlorine in swimming pools. (Cyanuric Acid)
- Do not add pool chemicals directly to the skimmer. This may damage the cell.
- Maintaining a salt and sanitizer level above the recommended range can contribute to the corrosion of the pool equipment.
- Check the expiry date of the test kit as the test results may be inaccurate if the kit is used after that date.
- If, due to heavy pool usage, it is required to increase the sanitizer level, then use a chemical based on trichlor, TCCA, or dichloro.
TROUBLESHOOTING GUIDE
PROBLEM | CAUSE | SOLUTION |
---|---|---|
INSUFFICIENT CHLORINE |
- Insufficient operating hours of the Saltwater System.
- The salt level in the pool water is less than 2000ppm. This is insufficient.
- Chlorine loss due to intense sunlight exposure.
- The bather load has increased.
- Clogged or dirty electrolytic cell.
- High UV level exposure.
|
- Increase the daily Saltwater System operating time. See “Operating Instructions”.
- Check the salt level with the Test Kit. Adjust as needed. See “Salt & Pool Water Volumes”.
- Use a pool cover when the pool is not in use and/or when the unit is operating.
- Increase the daily Saltwater System operating time. See “Operating Instructions”.
- Remove the cell for inspection, clean it if necessary. See “Maintenance”.
- Cover the pool with a pool cover for 2 days with the device running and then test the water using the test strips.
- If the pool is clean and clear, add a stabilizer to the water and then test the water with the device running.
WHITE FLAKES IN THE WATER| • Excessive calcium hardness is present in the
pool water.| • Drain about 20 to 25% of the pool water and add fresh water
to decrease the calcium hardness. Inspect the electrolytic cell for scale
buildup. Clean the electrolytic cell if necessary.
NO LED DISPLAY|
- No power supply.
- RCD has not reset.
- A power fuse has blown.
- LED failure.
|
- Find out the switch and turn it on.
- Reset the RCD
- Contact Intex Service Center.
LED PANEL CODE
| PROBLEM|
SOLUTION
---|---|---
LED Panel Code Flash & Alarm On ( NOTE : Always turn off the power before
cleaning and servicing).
**| 1. Filter pump not attached to the system and/or switch on.| •
Ensure a filter pump with the correct flow rate is attached and operating. See
“Setup Instruction”.
2. Circulation line is blocked.| • Remove the black hat-like plugs from
the pool strainer connectors.
• Clear your filter cartridge and cell from debris and dirt. See
“Maintenance”.
• Release all trapped air in the circulation line. See the filter pump
manual.
3. Incorrect inlet and outlet hose direction.| • Check the direction of
the inlet and the outlet hose. Reverse the hoses if necessary. See “ Set Up
Instructions”.
4. Scale on flow sensor pins inside the titanium electrode.| • Clean the
titanium electrode. See the “Maintenance” section.
5. Electrode cord is loose.| • Plug the cord into the electrode and
tighten the plug collar firmly.
6. Inner timer conflict between filter pump and saltwater system.| •
Reset both timers on the filter pump and saltwater system. See “Operating
Instructions”.
**| 1. Dirt or scale on titanium plates.| • Remove primary
electrolytic cell for inspection. Clean it if necessary. See “Maintenance”.
2. Low salt level / No salt.| • Add salt. See “Salt & Pool Water
Volumes”.
3. Electrolytic cell cord is loose.| • Ensure that the cell cord is
plugged firmly into the cell housing receptacle.
4. Possible electrolytic cell failure.| • Contact Intex Service Center.
Replace the cell if needed.
**| 1. High salt level.
2. Water temperature > 35ºC.
3.** Titanium electrode failure.| • Partially drain the pool and refill it
with fresh water. See “Salt & Pool Water Volumes”.
• Contact Intex Service Center.
• Contact Intex Service Center.
IMPORTANT
If you continue to experience diffi culty, please contact our Consumer Service
Department for assistance. See separate “Authorized Service Centers” sheet.
LIMITED WARRANTY
Your Krystal Clear™ Saltwater System has been manufactured using the highest
quality materials and workmanship. All Intex products have been inspected and
found free of effects prior to leaving the factory. This limited warranty
applies only to the Krystal Clear™ Saltwater System and accessories listed
below.
This limited warranty is in addition to, and not a substitute for, your legal
rights and remedies.
To the extent that this warranty is inconsistent with any of your legal
rights, they take priority.
For example, consumer laws across the European Union provide statutory
warranty rights in addition to the coverage you receive from this limited
warranty: for information on EU-wide consumer laws, please visit the European
Consumer Center website at http://ec.europa.eu/consumers/ecc/contact_en/htm.
The provisions of this limited warranty apply only to the original purchaser
and are not transferable. This limited warranty is valid for the period noted
below from the date of the initial retail purchase. Keep your original sales
receipt with this document, as proof of purchase will be required and must
accompany warranty claims or the limited warranty will be invalid.
Krystal Clear TM Saltwater System Warranty – 2 Years
Titanium electrode Warranty – 1 Year
Hoses & Fittings Warranty – 180 days
If you find a manufacturing defect in the Krystal Clear™ Saltwater System
during the warranty periods noted above, please contact the appropriate Intex
Service Center listed in the separate “Authorized Service Centers” sheet. If
the item is returned as directed by the Intex Service Center, the Service
Center will inspect the item and determine the validity of the claim. If the
item is covered by the provisions of the warranty, the item will be repaired
or replaced, with the same or comparable item (at Intex’s choice) at no charge
to you.
Other than this warranty, and other legal rights in your country, no further
warranties are implied. To the extent possible in your country, in no event
shall Intex be liable to you or any third party for direct or consequential
damages arising out of the use of your Krystal Clear™ Saltwater System, or
Intex or its agents’ and employees’ actions (including the manufacture of the
product). If your country does not allow the exclusion or limitation of
incidental or consequential damages, this limitation or exclusion does not
apply to you.
You should note that this limited warranty does not apply in the following
circumstances:
• If the Krystal Clear
TM
Saltwater System is subject to negligence, abnormal use or
application, accident, improper operation, improper voltage or current
contrary to operating
instructions, improper maintenance or storage;
- If the Krystal Clear™ Saltwater System is subject to damage by circumstances beyond Intex’s control, including but not limited to, ordinary wear and tear and damage caused by exposure to fire flood, freezing, rain, or other external environmental forces;
- To parts and components not sold by Intex; and/or
- To unauthorized alterations, repairs, or disassembly to the Krystal Clear™ Saltwater System by anyone other than Intex Service Center personnel.
The costs associated with the loss of pool water, chemicals, or water damages are not covered by this warranty. Injury or damage to any property or person is not covered by this warranty. Read the owner’s manual carefully and follow all instructions regarding the proper operation and maintenance of your Krystal Clear™ Saltwater System. Always inspect your product prior to use. This limited warranty will be void if use instructions are not followed.
©2021 Intex Marketing Ltd. – Intex Development Co. Ltd. – Intex Recreation
Corp.
All rights reserved
®™ Trademarks used in some countries of the world under license from Intex
Development Co. Ltd., Hong Kong &
Intex Recreation Corp., P.O. Box 1440, Long Beach, CA 90801 • Distributed in
the European Union by – The Netherlands
www.intexcorp.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>