AERIAL AD 110 Dehumidifier Instruction Manual
- June 6, 2024
- AERIAL
Table of Contents
AERIAL AD 110 Dehumidifier Instruction Manual
Product overview
Front view
- Air intake area with filter
- Control panel
- Air outlet
Back view
- Bracket for wall mount
- Discharge nozzle for discharge hose
- Mains plug
- Discharge hose
Inside view
- Heat exchanger cover
- Pump
- Fan
- Compressor
Overview of control panel
-
Humidity switch:
0 = off
Cont. = continuous operation -
Signal lights
-
Actual room temperature/Actual room humidity
-
Operating hours
-
Operating state/Target room humidity
Signal light| State|
Meaning
---|---|---
| Illuminated| Target room humidity reached
| Illuminated| Dehumidifying room
| Illuminated| Outside temperature <1°C or >34 °C
| Illuminated| Fault
Flashing| Pump fault. The pump will start up again automatically once the
fault has been repaired.
Overview of wall attachment
- Wall mount
- Top edge of wall mount
- Drilled hole Ø = 8 mm (2x)
About these operating instructions
These operating instructions must not be reproduced, duplicated or distributed without the written consent of the manufacturer.
Important: Read carefully before use. Keep for later reference.
Product description
The dehumidifier controls the air humidity in the room. The condensate water which is produced is pumped away via a discharge hose. The dehumidifier has an automatic defrost function. The dehumidifier is designed to be wall-mounted.
Package contents
- Dehumidifier
- Operating instructions
- Wall mount
- Universal installation kit for wall attachment
- Discharge hose 12 x 2 mm with hose clamp
Identification plate
The identification plate is on the housing.
Safety
Intended use and conditions of use
The dehumidifier is used to remove humidity from the air where there is atmospheric pressure in closed indoor rooms, such as basements, garages or warehouses, and is designed to be wall mounted.
The dehumidifier must only be mounted, used and stored in rooms larger than 4
m2.
The dehumidifier must only be used in compliance with the Technical Data.
Persons with physical, sensory or mental restrictions and children are not
permitted to use the dehumidifier. Every user must have read and understood
the operating instructions.
Foreseeable misuse
The dehumidifier must not be used:
- In rooms with potentially explosive atmospheres.
- In rooms with an aggressive atmosphere (e.g. caused by chemicals).
- In rooms with water with a pH value below 7.0 or above 7.4.
- In rooms with salt or liquids with a salt content > 1 %, e.g. brine baths.
- In rooms with ozone-treated air, high solvent concentrations or high dust pollution.
General safety information
WARNING! Risk of explosion, burns and poisoning from refrigerants!
The appliance contains an odorless, flammable refrigerant which, if handled
incorrectly, could result in explosions and fire as well as injuries and
burns. The refrigerant circuit is pressurized.
- Do not use any objects to accelerate the thawing process.
- Do not store the dehumidifier in rooms with permanent sources of ignition, such as open flames, operational gas appliances or electric heaters.
- Do not drill open or ignite dehumidifiers.
- Only operate the appliance in an adequately ventilated room larger than 4 m2.
- Any work to the refrigerant circuit must be performed by the manufacturer or the manufacturer’s authorised technical personnel. Before working on the refrigerant circuit, it must be depressurized using the designated mechanisms.
- Observe the national regulations for gas installations.
- Do not dump refrigerants or dispose of them as household waste.
- Avoid coming into contact with the refrigerant.
WARNING! Electrocution!
Working on live components or water on live components can cause life-
threatening electrocution.
- Avoid contact between water and live components.
- Always switch off and unplug the dehumidifier before moving it to another location.
- Only allow the manufacturer or authorised personnel to carry out work on electric components.
Unpacking
Procedure
- Check that the package contents are complete. Contact your stockiest in the event of damage or missing contents.
- Remove the packaging and dispose of it in accordance with local regulations.
Transport and connection
Transport
WARNING! Crushing as a result of instability!
- Transport the dehumidifier in an upright position and secure it so that it cannot tip over or slip.
- Position the dehumidifier on a stable, even surface.
WARNING! Risk of cuts and crushing from incorrect handling during transport
- Do not reach into openings such as air filters.
- The dehumidifier must be transported by two people using appropriate lifting and transport equipment.
Procedure
- Make sure that the discharge hose and the mains cable have been disconnected from the appliance.
- Transport the dehumidifier to where it is going to be used.
Installing the dehumidifier
WARNING! Risk of dehumidifier falling as a result of incorrect assembly!
- Only use the wall mount provided and universal installation kit.
- The dehumidifier must be installed by two people.
- Make sure that the wall is sound and capable of bearing the load.
Requirements
The air must circulate freely. Do not cover the air openings. There must be a
clearance of at least 100 cm in front of the air outlet and the air filter.
There must be at least 10 cm between the top of the wall mount and the nearest
object to allow the device to be mounted.
There must be at least 60 cm between the bottom of the wall mount and the nearest object.
Procedure
- Remove and set aside the two screws used to pre-assemble the wall mount to the dehumidifier.
- Use a spirit level to position the wall mount horizontally and fix to the wall using the universal installation kit as shown in fig. 5. Drilled hole Ø = 8 mm.
- Hang the dehumidifier on the bracket of the wall mount.
- Screw the dehumidifier to the wall mount using the two screws from step 1 to secure the device so that it does not fall.
Connecting the discharge hose
ATTENTION! Inadequate appliance output!
- Do not bend the discharge hose.
- Do not place any objects on the hose.
Procedure
- Attach the discharge hose on the back of the device to the discharge nozzle and secure with the hose clamp.
Run the discharge hose away from the dehumidifier to a drain (maximum height difference: 3 m).
Electrical connection
Procedure
- Make sure that the supply voltage is the same as the connection voltage in the technical data.
- Provide an adequate fuse for the socket and the power supply.
- Install an earth leakage circuit breaker in damp rooms and building sites.
- Make sure that the mains plug is suitable for the socket of the building.
- Make sure that the socket used is earthed.
- Plug the mains plug into the socket.
Operation
Dehumidifying the room
NOTE: Allow the dehumidifier to rest in its final position for approx. 15 minutes before starting up, after transport and after prolonged storage.
Procedure
- Make sure that the condensate water can drain off through a discharge hose
- Turn the humidity switch from “0” to “Cont”. Set the desired humidity at the humidity switch. The dehumidifier will only start if the actual room humidity is higher than the target room humidity.
Light illuminates. The dehumidifier will start operating. The dehumidifier runs for at least 10 minutes. Once the target room humidity has been reached, the fan continues to run for 30 minutes. If the actual room humidity increases by 5% during the cool-down period, the light flashes and the compressor restarts when the time is up. If the humidity switch is at “Cont”, the dehumidifier will run continuously.
Maintenance and care
- Only clean the dehumidifier with compressed air in open spaces.
- Wear a protective mask and goggles.
WARNING! Risk of injury from rotating fan.
Before opening the bezel :
- Disconnect the mains plug and wait at least 15 s.
- Make sure that the fan has stopped.
CAUTION! Risk of burning from hot cables!
Some cables inside the housing can get hot and cause slight burns.
- Allow the cables to cool down sufficiently.
ATTENTION! Damage to property!
- Cleaning agents can damage surfaces. Only use mild detergents.
- Only use approved original spare parts.
Cleaning and inspection
Procedure
-
Switch off the dehumidifier.
-
Unplug the mains plug.
-
Remove and clean the air filter (e.g. with vacuum cleaner) or replace it.
-
Check the discharge nozzle and hose, if connected.
-
Insert a new or clean filter. Only use an original filter.
-
Undo the screws on the side panels and the lid and remove the bezel.
-
Undo the screws on the heat exchanger cover and remove the lid.
-
Pull out the drip tray slightly (Pos. 1) and wipe with a cloth.
-
Push the drip tray back in again.
-
WARNING! Risk of electrocution from leaking condensate water! After cleaning the drip tray, make sure that the drain hose (Pos. 2) is inserted in the pump opening.
-
Carefully blow off the device with compressed air. Make sure that all of the components have been cleaned.
-
Fit the heat exchanger cover.
-
Fit the bezel.
-
Plug in the mains cable.
Spare parts and customer service
If you have any questions about the dehumidifier or require spare parts, contact your authorised dealer or AERIAL Service.
Troubleshooting
Please check the following points in the event of a fault. If necessary contact AERIAL Service.
WARNING! Poisoning from refrigerant, burns, crushing or electrocution during maintenance work!
- Only allow the manufacturer or authorised personnel to carry out repairs and maintenance work.
- In the event of malfunctions, switch off the dehumidifier and secure it so that it cannot be switched back on again.
- Allow any hot components to cool sufficiently before working on them.
Error messages
Display message | Possible cause | Remedial action |
---|---|---|
Outside temperature < 1°C or > 34°C | Appliance will automatically restart |
as soon as the temperature is > 5°C or< 30°C.
| Cooling system fault| Contact AERIAL Service.
Faults
Problem| Possible cause|
Remedial action
---|---|---
The dehumidifier is not performing well/removing moisture.| Air filter is
dirty. The dehumidifier is not getting enough air. Dirty filters can damage
the appliance in the long term.| dehumidifier is not getting enough air. Dirty
filters can damage the appliance in the long term. Clean the filter or replace
if necessary.
The dehumidifier is out of operation / fan and compressor are not working.|
Dehumidifier is switched off.| Switch on the dehumidifier.
Pump fault| There is no power supply to the dehumidifier| Check the power
supply.
Pump is blocked, e.g. water cannot drain out of the discharge hose.| Check the
discharge hose, if connected.
Pump faulty.| Contact AERIAL Service.
Decommissioning
Procedure
- Switch off the dehumidifier.
- Unplug the mains plug.
- Cover the dehumidifier with a cloth to protect it from dust.
Storage
CAUTION! Injury!
- Do not stack more than two dehumidifiers on top of each other.
- Secure the dehumidifiers so that they do not fall over.
Procedure
- Store the dehumidifier between 0°C and +40°C.
Disposal
ATTENTION! Risk from materials and substances.
- Sort materials according to type and recycle in accordance with local regulations.
- When disposing of auxiliary and operating materials, observe the local regulations and information on the safety data sheets.
Do not dispose of the dehumidifier as household waste but rather in accordance with the legal regulations.
EC Declaration of Conformity in accordance with Machinery Directive
2006/42/EC Appendix II 1.A
Manufacturer: Dantherm GmbH Oststraße 148 22844 Norderstedt
Product : Dehumidifier
Product no.: AD110
Functional description : The dehumidifier is used to remove humidity from
air where there is atmospheric pressure in closed rooms.
We hereby confirm that the product complies with the relevant provisions of
the following directives:
- 2006/42/EC Machinery directive
- 2014/ 30/ EU Directive on electromagnetic compatibility (EMC)
The following harmonized standards have been applied:
- EN 60335-2-40:2003
- N 60204-1:2006
- EN 378-2:2016
- EN ISO 12100:2010
- EN ISO 13857:2008
- EN ISO 14120:2015
Person authorised to compile the technical documentation: Manfred Föhlisch -\ Oststraße 148 – 22844 Norderstedt.
Norderstedt, 30 March 2020
| AD110
---|---
| 230 V / 50 Hz
W max
| 350 W
| IP 44
| 46 dB/A
|
490 x 330 x 280 mm
| 18,5 kg
| 4 /0,0006 t
| Rotary
| R-1234yf/0,14 kg
| + 1 °C – + 34 °C
| 35 % – 99 %
| 3 m
| 225 m3 /h
| % 15 l/d