AERIAL AD 740 Dehumidifier Instruction Manual
- June 5, 2024
- AERIAL
Table of Contents
- Models
- Product overview
- Overview of the control panel
- About these operating instructions
- Product description
- Safety
- Unpacking
- Stacking appliances
- Transport and connection
- Operation
- Maintenance and care
- Troubleshooting
- Decommissioning, storage, and disposal
- EC Declaration of Conformity
- Technical Data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Dehumidifier
AD 740,AD 40
Series
Operating Instructions
Models
These operating instructions relate to various models. The functions and
operations are virtually identical. You can find out which model you have from
the identification
plate. Further information can be found in the Technical Data (see the last
page).
Model | Main characteristics |
---|---|
AD 740 | Hinged handle, 2 wheels |
AD 40 | Carry handles, feet |
Product overview
Fig. 1: Front view
1 | Control panel | 6 | Socket |
---|---|---|---|
2 | Hinged handle (AD 740 only) | 7 | Wheels (AD 740) |
3 | Mains plug | 8 | Attachment points for safety harnesses |
4 | Socket fuse | 9 | Feet (AD 40) |
5 | Air outlet |
Fig. 2: Back view
1 | Air intake area with filter | 4 | Basin |
---|---|---|---|
2 | Ambient temperature sensor | 5 | Basin lock |
3 | Drip tray |
Overview of the control panel
Fig. 3: Overview of the control panel
1 | Actual room humidity | 7 | Load counter (MID) |
---|---|---|---|
2 | Increase room humidity | 8 | “Basin full” indicator |
3 | Target room humidity | 9 | Info key |
4 | Lower room humidity | 10 | Night mode |
5 | Fan setting | 11 | Operating hours |
6 | On/off button | 12 | Display |
Button | Press briefly | Press for 5s | Display |
---|---|---|---|
Lower/raise room humidity in 1% increments | |||
From the Language menu: Select language | Lower/increase room humidity | ||
in 5% increments | |||
On/off button | Switch dehumidifier on/off | Start 45% 12345h | |
Change fan levels |
Level 2: Higher fan power
Level 1: Lower fan power| | fan speed high
fan speed low
| Press twice briefly:
Setting the language| Unlock key
lock| Language
English
About these operating instructions
These operating instructions must not be reproduced, duplicated, or
distributed without the written consent of the manufacturer.
Important: Read carefully before use. Keep for later reference.
Product description
The dehumidifier controls the air humidity in the room. The condensate water produced is collected in a basin or pumped away via an optional discharge hose. The dehumidifier has an automatic defrost function.
Package contents
- Dehumidifier
- Operating instructions
- Basin (in the appliance)
Optional accessories
- Pump kit
- Discharge hose
Identification plate
The identification plate is on the basin.
Safety
Intended use and conditions of use
The dehumidifier is used to remove humidity from the air where there is
atmospheric pressure in closed indoor rooms, such as basements, garages, or
warehouses. The dehumidifier must only be set up, used, and stored in rooms
larger than 4 m 2. The dehumidifier must only be used in compliance with the
Technical Data (see the last page). Persons with physical, sensory, or mental
restrictions and children are not permitted to use the dehumidifier. Every
user must have read and understood the operating instructions.
Foreseeable misuse
The dehumidifier must not be used:
- In rooms with potentially explosive atmospheres.
- In rooms with an aggressive atmosphere (e.g. caused by chemicals).
- In rooms with water with a pH value below 7.0 or above 7.4.
- In rooms with salt or liquids with a salt content > 1 %, e.g. brine baths.
- In wet areas of indoor swimming pools.
- In rooms with ozone-treated air, high solvent concentrations, or high dust pollution.
General safety information
WARNING! Risk of explosion, burns, and poisoning from refrigerants!
The appliance contains an odorless, flammable refrigerant which, if handled
incorrectly, could result in explosions and fire as well as injuries and
burns.
The refrigerant circuit is pressurized.
- Do not use any objects to accelerate the thawing process.
- Do not store the dehumidifier in rooms with permanent sources of ignition, such as open flames, operational gas appliances, or electric heaters.
- Do not drill open or ignite dehumidifiers.
- Only operate the appliance in an adequately ventilated room larger than 4 m².
- Any work to the refrigerant circuit must be performed by the manufacturer or the manufacturer’s authorized technical personnel. Before working on the refrigerant circuit, it must be depressurized using the designated mechanisms.
- Observe the national regulations for gas installations.
- Do not dump refrigerants or dispose of them as household waste.
- Avoid coming into contact with the refrigerant.
WARNING! Electrocution!
Working on live components or water on live components can cause life-
threatening electrocution.
- Avoid contact between water and live components.
- Always switch off and unplug the dehumidifier and drain away any water before moving it to another location.
- Always empty the basin before moving it to another location.
- Only allow the manufacturer or an authorized personnel to carry out work on electric components.
Unpacking
Procedure
- Check that the package contents are complete. Contact your stockist in the event of damage or missing contents.
- Remove the packaging and dispose of it in accordance with local regulations.
Stacking appliances
Two appliances from this series can be stacked on top of each other for transport and storage.
Warning! Crushing as a result of tipping or instability!
- Do not stack more than two dehumidifiers on top of each other. Make sure that the feet of the top appliance is in the notches of the bottom appliance.
- Secure the dehumidifiers to prevent them from tipping over or falling, e.g. using tension belts.
Procedure
- Place the feet of the top appliance in the appropriate notches of the bottom appliance.
- Attach a suitable safeguard, e.g. tension belts, to the attachment points for straps to secure the top appliance to the bottom appliance and stop it from falling off. Stack a maximum of two appliances.
Transport and connection
Transport
WARNING! Crushing as a result of instability!
- Transport the dehumidifier in an upright position and secure it so that it cannot tip over or slip.
- Position the dehumidifier on a stable, even surface.
WARNING! Crushing or cutting from reaching into the grille of the air filter!
- Use the handles to transport the dehumidifier.
- Do not reach into the air filter.
CAUTION! Crushing or ergonomic damage when transporting the dehumidifier!
- Use the handles to transport the dehumidifier.
- The dehumidifier must be transported by two people.
Procedure
- Make sure that the basin is empty and secured with the basin lock.
- Make sure that the discharge hose (optional) and the main cable have been disconnected from the appliance.
- AD 740: Raise the hinged handle for transporting on the wheels. To do this, release the lock on the right and left of the hinged handle (item 1) and lift the hinged handle until the lock engages again.
- Transport the dehumidifier to where it is going to be used.
- AD 740: Fold the hinged handle back down again.
NOTE: The air must circulate freely. Do not cover the air openings. There must be a clearance of at least 1 m in front of the air outlet and the air filter.
Preparing the basin
Does not apply if an optional discharge hose is connected.
Procedure
- Slide the basin into the dehumidifier.
- Secure the basin with the basin lock.
Connecting an optional discharge hose
If necessary, the condensate water can be drained off via a discharge hose
instead of into the basin.
To do this, proceed as follows:
ATTENTION! Inadequate appliance output!
- Do not place the end of the hose in the water (backwater possible).
- Do not bend the discharge hose.
- Do not place any objects on the hose.
Procedure
- Remove the basin.
- Attach a suitable hose (12 x 2 mm) to the discharge nozzle (Pos. 2) using a pipe clip.
- Make sure that the end of the hose is lower than the start of the hose at the discharge nozzle. Minimumslope of 5 % (5 cm/metre).
- Slide the top cover sheet (item 3) in front of the notch (item 4). To do this, loosen the screw on the cover sheet and slide the cover sheet to the top.
- Run the end of the hose into a drain or a suitable container.
Electrical connection
Procedure
- Make sure that the supply voltage is the same as the connection voltage in the technical data.
- Provide an adequate fuse for the socket and the power supply.
- Install an earth leakage circuit breaker in damp rooms and building sites.
- Make sure that the main plug is suitable for the socket of the building.
- Make sure that the socket used is earthed.
- Plug the mains plug into the socket.
- If necessary, connect one more appliance at most to the socket on the dehumidifier. If more than one appliance is connected, the integrated socket fuse will stop the appliances from working.
Operation
Unlock key lock
The key lock activates automatically if the control panel is inactive for 2
minutes.
Procedure
- Hold the key down for 5 seconds.
The key lock is released.
Setting the language
Procedure
- Press the key twice in quick succession.
- The display will show the current language.
- Set the desired language using the arrow keys .
- Wait 3 seconds until the selected language stops flashing.
Dehumidifying the room
NOTE: Allow the dehumidifier to rest in its final position for approx. 15
minutes before starting up, after transport, and after prolonged storage.
Procedure
- Make sure that the condensate water can drain off through a discharge hose or into the basin.
- Set the on/off button to “I”. “Start” will flash on the display. The dehumidifier will start operating. Operation is not possible when “Stop” or “Start” is flashing.
- Set the desired humidity using the arrow keys . The dehumidifier will only start if the actual room humidity is higher than the target room humidity.
- Select the fan level. To do this, press the key.
The dehumidifier runs until the target room humidity has been reached or the basin is full, then it will stop running.
Emptying the basin
The “Basin full” indicator flashes, the basin is full. Procedure
- Release the basin lock.
- Empty the basin.
- Secure the basin again with the basin lock.
Night mode
If necessary, night mode can be enabled for quieter operation for 10 hours.
- Press the key.
The dehumidifier runs for 10 hours at level 1.
Switching off
Procedure
- Empty basin if necessary.
- Set the on/off button to “0”.
Maintenance and care
WARNING! Electrocution!
- Always disconnect the mains plug to disconnect the dehumidifier from the power supply before cleaning the defrosting tray of the AD40.
WARNING! Damage to health from dust!
- Only clean the dehumidifier with compressed air in open spaces.
- Wear a protective mask and goggles.
ATTENTION! Damage to property!
-
Cleaning agents can damage surfaces.
Only use mild detergents. -
Only use approved original spare parts.
Cleaning and inspection
Procedure
- Switch off the dehumidifier.
- Unplug the mains plug.
- Remove and clean the air filter (e.g. with a vacuum cleaner) or replace it.
- Check the discharge nozzle and discharge hose, if connected.
- AD 740 only: Pull out the drip tray slightly and wipe with a cloth.
- AD 40 only: Remove the filter holder. To do this, undo the four marked screws with a suitable screwdriver and remove the filter holder.
- Nur AD 40: The drip tray is on the filter cover (item 5). Wipe the drip tray with a cloth.
- Insert/push in the drip tray again and fit the filter cover again if necessary.
- Insert a new or clean filter. Only use an original filter. Make sure that the notch (item 6) is facing up.
- Plug in the main cable.
- Switch on the dehumidifier if necessary.
Spare parts and customer service
If you have any questions about the dehumidifier or require spare parts,
contact your authorized dealer or AERIAL Service.
Troubleshooting
Please check the following points in the event of a fault. If necessary contact AERIAL Service.
WARNING! Poisoning from refrigerant, burns, crushing, or electrocution during maintenance work!
- Only allow the manufacturer or an authorized personnel to carry out repairs and maintenance work.
- In the event of malfunctions, switch off the dehumidifier and secure it so that it cannot be switched back on again.
- Allow any hot components to cool sufficiently before working on them.
Error messages
Display message
| Possible cause|
Remedial action
---|---|---
Error El
Error E2
Check the air intake area and air outlet. Both must be freely accessible.
Faulty refrigeration circuit| Contact AERIAL Service.
Faults
Problem | Possible cause | Remedial action |
---|---|---|
The dehumidifier is not performing well/removing moisture. | The air filter is |
dirty. The dehumidifier is not getting enough air. Dirty filters can damage
the appliance in the long term.| Clean the filter or replace it if necessary.
The dehumidifier is out of operation/fan
and the compressor is not working.| A dehumidifier is switched off.| Switch on
the dehumidifier.
There is no power supply to the dehumidifier.| Check the power supply.
“Basin full” illuminates even though the basin is empty.| Basin was not
inserted correctly.| Insert basin correctly.
Pump fault.
| The pump is blocked, e.g. water cannot drain out of the discharge
hose/basin.| Check the discharge hose/basin, if connected.
Pump faulty.| Contact AERIAL Service.
Decommissioning, storage, and disposal
Decommissioning
⇒ Secure the dehumidifiers to prevent them from tipping over or falling, e.g. using tension belts.
Procedure
- Switch off the dehumidifier.
- Empty the basin.
- Unplug the mains plug.
- Cover the dehumidifier with a cloth to protect it from dust.
Procedure
- Store the dehumidifier between 0 °C and +40 °C.
Storage
WARNING! Injury!
⇒ Do not stack more than two dehumidifiers on top of each other. Make sure
that the feet of the top appliance is in the notches of the bottom appliance.
Disposal
ATTENTION! The risk from materials and substances
Do not dispose of the dehumidifier as household waste but rather in accordance with the legal regulations.
⇒ Sort materials according to type and recycle in accordance with local
regulations.
⇒ When disposing of auxiliary and operating materials, observe the local
regulations and information on the safety data sheets.
EC Declaration of Conformity
EC Declaration of Conformity In accordance with Machinery Directive
2006/42/EC Appendix II 1. A
Manufacturer: Dantherm GmbH Oststraße 148 22844 Norderstedt Product:
Dehumidifier
Product no.: AD 740 / AD 40
Functional description: The dehumidifier is used to remove humidity from
the air where there is atmospheric pressure in closed rooms.
We hereby confirm that the product complies with the relevant provisions of the following directives:
- 2006/42/EC Machinery directive
- 2014/ 30/ EU Directive on electromagnetic compatibility (EMC)
The following harmonized standards have been applied:
- 60335-2-40:2003
- 60335-1:2012
- 60204-1:2018
- 378-2:2016
- ISO 12100:2010
- ISO 13857:2008
- ISO 14120:2015
Person authorised to compile the technical documentation: Manfred Föhlisch –
Oststraße 148 – 22844 Norderstedt
Norderstedt, 30/11/2020
Technical Data
|
AD 740
|
AD 40
---|---|---
|
230 V / 50 Hz
W max
|
650 W
|
IP X1
|
51 dB/A
|
53 dB/A
H/W/L
|
690 / 390 / 470 mm
|
580 / 390/ 450 mm
|
32 kg
|
25 kg
GWP / CO₂|
148 /0,047 t
|
Rotary
|
R454C /0,32 kg
|
+ 5 °C – + 34 °C
|
35 % – 99 %
|
450 m³/h
|
300 m³/h
|
550 m³/h
|
400 m³/h
30 °C / 80 %|
34 1/d
|
33.51/d
20 °C / 60 %|
18 1/d
|
16 1/d
Dantherm GmbH · Systeme zur Luftbehandlung
Oststraße 148 · D-22844 Norderstedt
Phone 0049 (0) 40 526 879 0 · Telefax 526 879 20
E-Mail: info.de@dantherm.com · Internet:
www.aerial.de