FGT-001 Temperature Controller
Instruction Manual
Nice
Heat-Control Kit
Heat control with temperature measurement
Instructions and warnings for installation and use
WARNING AND GENERAL PRECAUTIONS
- CAUTION! This manual contains important instructions and warnings for personal safety. Carefully read all parts of this manual. If in doubt, suspend installation immediately and contact Nice Technical Assistance.
- CAUTION! Important instructions: keep this manual in a safe place to enable future product maintenance and disposal procedures.
- CAUTION! Any use other than that specified herein or in environmental conditions other than those stated in this manual is to be considered improper and is strictly forbidden!
- The product’s packaging materials must be disposed of in full compliance with local regulations.
- Never apply modifications to any part of the device. Operations other than those specified may only cause malfunctions. The manufacturer declines all liability for damage caused by makeshift modifications to the product.
- Do not expose this product to moisture, water, or other liquids.
- This product is designed for indoor use only. Do not use it outside!
- This product is not a toy. Keep away from children and animals! CR2032 coin cell battery is harmful if swallowed!
Battery pack warning!
The Heat Controller contains a lithium-ion polymer battery pack, heed all the
following warnings:
- If an unusual odor or malfunction is detected, avoid sources of open flame and remove the device from the radiator.
- In the event of damage from crashes, etc., carefully remove to a safe place for at least a half-hour to observe.
- Do not leave the device unattended while charging.
- Do not attempt to replace the battery!
PRODUCT DESCRIPTION
A heat Controller is a remotely controlled thermostatic head to control the
temperature in your room. It measures the temperature and automatically
adjusts the heat level. It can be mounted without tools on three types of
thermostatic radiator valves. You can create schedules via app to easily
manage temperature throughout the week.
Main features
- can be installed on three types of valves: M30 x 1.5, Danfoss RTD-N, and Danfoss RA-N,
- compatible with any certified Z-WaveTM Controller,
- supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption,
- built-in battery recharged through a standard micro-USB port,
- easy installation – no tools required,
- can use a dedicated temperature sensor – Temp-Control,
- supports heating schedules,
- automatic calibration,
- anti-freeze function,
- descaling function,
- unconstrained rotation spherical knob to set the desired temperature.
Heat-Control is a fully compatible Z-Wave PlusTM device.
This device may be used with all devices certified with the Z-Wave Plus
certificate and should be compatible with such devices produced by other
manufacturers. All non-battery-operated devices within the network will act as
repeaters to increase the reliability of the network. The device is a Security
Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be
used in order to fully utilize the product. The device supports Z-Wave network
Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-
based encryption.
BASIC ACTIVATION
If you use one of the adapters, double-check that it is mounted properly. It should click when putting on the valve, hold tight after installing and not rotate!
- If the device is installed in a vertical position, set bit 5 in parameter 2.
- Do not cover or veil the thermostatic head. · First charging may take up to 3 hours.
-
Connect the charger to the micro-USB port to charge the device. The LED ring will pulse red if it’s not fully charged; otherwise, it will pulse green. If you have the temperature sensor:
Use a coin to open the battery cover by turning it counter-clockwise.
Remove the sticker underneath the battery. · Use a coin to close the battery cover by turning it clockwise. -
Disconnect the charger when the LED ring pulses green (device fully charged).
-
Dismount your current thermostatic head.
-
Depending on the type of your thermostatic valve:
-
Mount the device on the valve and tighten it by turning the cap clockwise.
-
Press and hold the button for at least one second. The LED ring will start blinking
If you have the temperature sensor:
- Click the button on the temperature sensor now.
- The LED ring on the thermostatic valve will blink green 5 times if the connection was successful.
ADDING THE DEVICE
- Full DSK code is present only on the box, make sure to keep it or copy the code.
- In case of problems with adding the device, please reset the device and repeat the adding procedure.
Adding (Inclusion) – Z-Wave device learning mode, allowing to add the device
to the existing Z-Wave network.
To add the device to the Z-Wave network manually:
-
Make sure the device is within the direct range of your Z-Wave controller.
-
Set the main controller in (security/non-security) add mode (see the controller’s manual)
-
Quickly triple-click the button on the thermostatic head.
-
The LED ring will start blinking white.
-
If you are adding in S2 authenticated mode, type in the device pin code (underlined part of the public key on the label).
-
Wait for the adding process to end.
-
Successful adding will be confirmed by the Z-Wave controller and green LED color.
REMOVING THE DEVICE
Removing (Exclusion) – Z-Wave device learning mode, allowing to remove
the device from the existing Z-Wave network.
To remove the device from the Z-Wave network:
- Make sure the device is within the direct range of your Z-Wave controller.
- Set the main controller into remove mode (see the controller’s manual).
- Quickly triple-click the button on the thermostatic head.
- The LED ring will start blinking white.
- Wait for the removing process to end.
- Successful removal will be confirmed by the Z-Wave controller and red LED color.
Note. Removing the device from the Z-Wave network restores all the default parameters of the device.
CONTROLLING THE TEMPERATURE
You can set the temperature using the app (10-30°C) or directly on the device (16-24°C). During manual temperature change LED ring color corresponds to the temperature set-point. To check and change the temperature on the device:
- Bring your hand close to the sphere.
- LED ring will:
· Glow if the temperature was set manually,
· Pulse slowly if the device is in schedule mode,
· Pulse quickly if the device is in override schedule mode.
» With color depending on set temperature:
Table A1 – Meaning of colors in relation to temperatures
Z-Wave Mode | Temperature [°C] | Colour |
---|---|---|
OFF | Valve closed (anti-freeze) | White |
16°C or lower | Blue | |
17°C | Azure | |
18°C | Cyan | |
19°C | Spring green | |
20°C | Green | |
21°C | Chartreuse | |
22°C | Yellow | |
23°C | Orange | |
24°C or higher | Red | |
MANUFACTURER-SPECIFIC | Valve fully opened | Magenta |
3. Turn the sphere counter-clockwise to lower the temperature or turn clockwise to raise the temperature.
4. Remove the hand from the sphere, after 5 seconds LED will fade and a new temperature will be set. You can set the temperature using the app (1030°C) or directly on the device (16-24°C).
EXTRA TEMPERATURE SENSOR
- Temp-Control is the only compatible temperature sensor.
- This product is not a toy. Keep away from children and animals!
The device can be used with an additional, dedicated temperature sensor (Temp- Control) to provide the best temperature regulation. It should be placed in the same room or heating zone as the thermostatic head which will use it as a reference point for the room temperature. Before use, the sensor must be paired with the thermostatic head. One thermostatic head can be paired with only one sensor, but one sensor can be paired with up to three thermostatic heads.
7.1 – Pairing Temp-Control
To pair the Temp-Control with the device:
-
Press and hold the button on the thermostatic head.
-
Release the button when you see the blue LED color.
-
Click the button to confirm the selection, the LED ring will start blinking blue.
-
Within 1 minute click the button on the sensor.
-
The LED ring on the thermostatic head will glow green to confirm successful pairing.
-
Place the sensor in the same room as the head, no further than 5 meters from it.
7.2 – Removing Temp-Control To remove all paired heads from the sensor’s memory:
- Press and hold the button on the sensor for 2 seconds.
- The LED on the sensor will blink 3 times to confirm unpairing.
DISMOUNTING THE DEVICE
Before dismounting, the device must be put in Standby Mode to ensure safe removal. See chapter ,, Standby Mode” for more information. To dismount the device:
- Press and hold the button.
- Release the button when you see a cyan LED color.
- Click the button to confirm the selection.
- Turn the cap counter-clockwise and remove the adapter if used.
- Store the device in temperatures: -10°C to 25°C.
MENU
The menu allows performing important configuration and maintenance actions. In order to use the menu:
- Press and hold the button.
- Release the button when you see desired LED color:
Table A2 – Meanings of colors while in the menu
Colour | Action |
---|---|
Blue | pair dedicated temperature sensor |
Red | enable/disable local control protection |
White | perform head calibration |
Green | adding/removing to/from the Z-Wave network |
Magenta | Z-Wave network’s range test |
Cyan | put the device in Standby Mode |
Yellow | factory reset |
3. Click the button to confirm the selection.
LOCAL PROTECTION
After enabling the local protection changing the temperature directly on the device (by turning it) will not be possible. Enabling local protection is recommended if you want to prevent accidental temperature change, e.g. by children.
- Local protection can also be enabled/disabled remotely through the Z-Wave controller.
- When attempting to change the temperature if local protection is enabled:
- The device will not set new target temperature,
- The LED ring will blink red 3 times. To change the temperature use the app or disable the local protection.
To enable/disable local protection using the menu:
- Press and hold the button.
- Release the button when you see the red LED color.
- Click the button to confirm the selection.
HEAD CALIBRATION
- Calibration cannot be performed while the device is being charged. Calibrating the device to your radiator valve is required for properly controlling the temperature.
Calibration is performed:
- Automatically, after 10 minutes from turning on if no operation on the device has been made (only at first installation),
- Automatically, after 10 minutes from last state change (only at first installation),
- Manually, using the menu (see below).
To perform calibration using the menu:
-
Press and hold the button.
-
Release the button when you see a white LED color.
-
Click the button to confirm the selection.
STANDBY MODE
In Standby Mode the device is in a deep sleep state allowing safe dismounting,
transporting, and low as possible battery consumption. The device is shipped
in Standby Mode. It should be fully charged before first use. Entering the
device in Standby Mode will not factory reset the device nor will result in
losing any data, but calibration and sensor pairing (after long Standby) is
lost. We recommend unpairing the temperature sensor before putting the device
into Standby Mode.
To enter Standby Mode:
- Press and hold the button.
- Release the button when you see a cyan LED color.
- Click the button to confirm the selection.
To exit Standby Mode click the button once, the device will enter first installation procedure.
FACTORY RESET
The reset procedure allows restoring the device back to its factory settings,
which means all information about the network and user configuration will be
deleted.
To perform a factory reset:
-
Press and hold the button.
-
Release the button when you see a yellow LED color.
-
Click the button to confirm the selection.
-
After finishing resetting the device will be put in Standby Mode. Click the button to activate it again.
Note. Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use the reset procedure only if the primary controller is missing or inoperable.
Z-WAVE RANGE TEST
The device has a built-in Z-Wave network main controller’s range tester.
To make the Z-Wave range test possible, the device must be added to the Z-Wave
controller. Testing may stress the network, so it is recommended to perform
the test only in special cases.
To perform a range test:
-
Press and hold the button.
-
Release the button when you see a magenta LED color.
-
Click the button to confirm the selection.
-
LED ring will indicate the Z-Wave network’s range:
- Pulsing green – the device attempts to establish direct communication with the main controller. If a direct communication attempt fails, the device will try to establish a routed communication, through other modules, which will be signaled by a visual indicator pulsing yellow.
- Glowing green – the device communicates with the main controller directly.
- Pulsing yellow – the device tries to establish a routed communication with the main controller through other modules (repeaters).
- Glowing yellow – the device communicates with the main controller through the other modules. After 2 seconds the device will retry to establish direct communication with the main controller, which will be signaled with a visual indicator pulsing green
- Pulsing magenta – the device does communicate at the maximum distance of the Z-Wave network. If the connection proves successful it will be confirmed with a yellow glow. It’s not recommended to use the device at the range limit.
- Glowing red – the device is not able to connect to the main controller directly or through another Z-Wave network device (repeater).
5. To exit the Z-Wave range test, press the button briefly.
BATTERY AND CHARGING
Do not leave the device unattended while charging.
- Make sure you are using certified charger Class II, marked which complies with parameters specified in the
- manual.
- Set the device to OFF (white) before charging or dismount the thermostatic head if not possible.
- Do not use cables longer than 3 meters for charging the device.
- Make sure the device won’t discharge during the heating season or it may cause high temperatures!
The device is equipped with a rechargeable lithium-polymer battery pack that
can be charged via a micro-USB port using a standard 5V charger (not
included). When the battery is low the LED ring will start to blink red. The
device will also report low battery status of itself and a dedicated
temperature sensor (if paired) to the controller. The device does not operate
the valve during the charging and maintains the last valve position. If the
battery is discharged the device will open the valve completely to allow easy
dismounting.
To charge the battery:
- Connect the charger to the micro-USB port.
- During charging the LED ring will pulse red and valve control will be disabled.
- When LED starts pulsing green, disconnect the charger.
- The device will restore its previous operation.
NORMAL SCHEDULES
The device allows the creation of multiple heating schedules to manage the temperature in the room throughout the week. Schedules are created via controller interface or app.
- Up to 253 normal schedules can be created.
- The lower the schedule ID number, the higher the priority.
- Schedules with higher priority override those with lower priority in case of overlapping schedules.
- Schedules can be disabled without deleting it.
- Schedules allow to set the target temperature for HEAT mode (using Thermostat Setpoint CC) and one of the operating modes: HEAT, OFF or MANUFACTURER SPECIFIC (using Thermostat Mode CC)
- Only SET commands are permitted.
To create normal schedules user must specify:
- Day of the week,
- Starting time (hour and minute),
- Duration,
- Temperature Setpoint for HEAT mode in the range 10-30°C (using Thermostat Setpoint CC)
- One of the operating modes (using Thermostat Mode CC):
» HEAT for setting temperature,
» OFF for valve fully closed,
» MANUFACTURER SPECIFIC for valve fully opened.
Note. Schedule CC Set command payload must not be greater than 22 bytes limit or it would be rejected.
OVERRIDE SCHEDULE
Override Schedule is a special type of schedule with the highest priority;
thus it overrides other schedules. The Override Schedule starts right after
setting and lasts for specified time, then it is removed and the current
schedule or normal operation is restored.
To create an Override Schedule user must specify:
- Starting time (START NOW),
- Duration,
- Temperature Setpoint for HEAT mode in range 10-30°C (using Thermostat Setpoint CC)
- One of the operating modes (using Thermostat Mode CC):
» HEAT for setting temperature,
» OFF for valve fully closed,
» MANUFACTURER SPECIFIC for valve fully opened.
Override Mode can be enabled in two ways:
- By turning the knob, while the normal schedule is active. The LED ring will pulse with the selected adjustment.
- Via controller, by creating a schedule with ID set 255, start time set to NOW and duration (in minutes/hours/days). To exit Override Mode grab the knob with your hand for 5 seconds.
Z-WAVE SPECIFICATION
Endpoint 1: Generic Device Class: GENERIC_TYPE_THERMOSTAT Specific Device
Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2 Description: represents the
thermostatic head, allows to set temperature, schedules, and check its battery
level.
Endpoint 2: Generic Device Class: GENERIC_TYPE_SENSOR_MULTILEVEL Specific
Device Class: SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL Description:
represents temperature sensor:
- Extra temperature sensor paired reports temperature measured by the extra sensor and its battery level,
- No extra temperature sensor paired reports temperature measured by the built-in sensor and head battery level.
Association Command Class: The device supports only the “Lifeline” association group that reports the device status and allows for assigning single device only (main controller by default).
Table A3 – Response to Basic Command Class
Value| Action
0| Set OFF mode (unfreeze function)
99| Set HEAT mode (last set temperature)
255| Set MANUFACTURER SPECIFIC mode (valve fully opened)
Table A4 – Supported Command Classes
Command Class| Version| Secure
ZWAVEPLUS_INFO [0x5E]| V2|
ASSOCIATION [0x85]| V2| YES
MULTI_CHANNEL_ASSOCIATION [0x8E]| V3| YES
BASIC [0x20]| V1| YES
APPLICATION_STATUS [0x22]| V1|
THERMOSTAT_MODE [0x40]| V3| YES
THERMOSTAT_SETPOINT [0x43]| V3| YES
SCHEDULE [0x53]| V1| YES
TRANSPORT_SERVICE [0x55]| V2|
ASSOCIATION_GRP_INFO [0x59]| V2| YES
DEVICE_RESET_LOCALLY [0x5A]| V1| YES
MULTI_CHANNEL [0x60]| V4| YES
SUPERVISION [0x6C]| V1| YES
NOTIFICATION [0x71]| V8| YES
MANUFACTURER_SPECIFIC [0x72]| V2| YES
POWERLEVEL [0x73]| V1| YES
PROTECTION [0x75]| V1| YES
FIRMWARE_UPDATE_MD [0x7A]| V4|
BATTERY [0x80]| V1| YES
CLOCK [0x81]| V1| YES
VERSION [0x86]| V2| YES
SECURITY [0x98]| V1|
SECURITY_2 [0x9F]| V1|
CONFIGURATION [0x70]| V1| YES
CRC_16_ENCAP [0x56]| V1|
---|---|---
SENSOR_MULTILEVEL [0x31]| V5| YES
Table A5 – Multichannel Command Class
Command Class| Version| Secure
Endpoint 1| |
ZWAVEPLUS_INFO [0x5E]| V2|
ASSOCIATION [0x85]| V2| YES
MULTI_CHANNEL_ASSOCIATION [0x8E]| V3| YES
BASIC [0x20]| V1| YES
THERMOSTAT_MODE [0x40]| V3| YES
THERMOSTAT_SETPOINT [0x43]| V3| YES
SCHEDULE [0x53]| V1| YES
ASSOCIATION_GRP_INFO [0x59]| V2| YES
SUPERVISION [0x6C]| V1| YES
NOTIFICATION [0x71]| V8| YES
BATTERY [0x80]| V1| YES
CLOCK [0x81]| V1| YES
PROTECTION [0x75]| V1| YES
SECURITY [0x98]| V1|
SECURITY_2 [0x9F]| V1|
Endpoint 2
ZWAVEPLUS_INFO [0x5E]| V2|
ASSOCIATION [0x85]| V2| YES
MULTI_CHANNEL_ASSOCIATION [0x8E]| V3| YES
SENSOR_MULTILEVEL [0x31]| V5| YES
ASSOCIATION_GRP_INFO [0x59]| V2| YES
SUPERVISION [0x6C]| V1| YES
NOTIFICATION [0x71]| V8| YES
BATTERY [0x80]| V1| YES
SECURITY [0x98]| V1|
SECURITY_2 [0x9F]| V1|
Notification Command Class: The device uses Notification Command Class to report different events to the controller (“Lifeline” group).
Table A6 – Notification Command Class (Endpoint 1)
Notification Type
| Event|
Event Parameters
Power Management [0x08]
| Charge battery soon [0x0E]|
Charge battery now! [0x0F]|
The battery is charging [0x0C]|
The battery is fully charged [0x0D]|
System [0x09]
|
System Hardware Failure [0x03]
| External sensor remove [0x02]
Motor error [0x03]
Calibration error [0x04]
Table A7 – Notification Command Class (Endpoint 2)
Notification Type| Event| Event Parameters
Power Management [0x08]| Replace battery soon [0x0A]|
Replace the battery now! [0x0B]|
ADVANCED PARAMETERS
The device allows customizing its operation to the user’s needs using configurable parameters. The settings can be adjusted via the Z-Wave controller to which the device is added. The way of adjusting them might differ depending on the controller.
Table A8 – Heat-Control – Available parameters
Parameter:| 1. Override Schedule duration
Description:| This parameter determines the duration of the Override Schedule
after turning the knob while the normal schedule is active (set by Schedule
CC).
Available settings:| 10-10 000 (in minutes)
Default setting:| 240 (4h)| Parameter size:| 4 [bytes]
Parameter:| 2. Additional functions
Description:| This parameter allows enabling of different additional functions
of the device.
Available settings:| 1 (bit 0) – open window detection (normal) 2 (bit 1) –
open window detection (rapid)
4 (bit 2) – increase receiver sensitivity (shortens battery life) 8 (bit 3) –
LED indications when controlling remotely
16 (bit 4) – protect from setting Full ON and Full OFF mode by turning the
knob manually 32 (bit 5) – device mounted in vertical position
64 (bit 6) – Moderate regulator behavior (instead of Rapid) 128 (bit 7) –
inverted knob operation
256 (bit 8) – heating medium demand reports
512 (bit 9) – detecting heating system failures
Default setting:| 1| Parameter size:| 4 [bytes]
Parameter:| 3. Additional functions status (read-only)
Description:| This parameter allows checking statuses of different additional
functions.
Available settings:| 1 (bit 0) – optional temperature sensor connected and
operational 2 (bit 1) – open window detected
4 (bit 2) – provide heat in order to maintain the set temperature
8 (bit 3) – malfunctioning heating system (cannot reach set temperature)
Default setting:| 0| Parameter size:| 4 [bytes]
Notes:
- Entering invalid values of parameters will result in not setting the value and response with the Application Rejected or Supervision CC frame (depending on the controller).
- Parameter 2 values may be combined, e.g. 1+8=9 means that Open Window Detector and LED indications when controlling remotely are enabled.
- Parameter 3 values may be combined, e.g. 1+2=3 means the optional sensor works properly and open window detection was triggered.
TECHNICAL SPECIFICATIONS
The product Heat-Control is produced by Nice S.p.A. (TV). Warnings: – All technical specifications stated in this section refer to an ambient temperature of 20 °C (± 5 °C) – Nice S.p.A. reserves the right to apply modifications to the product at any time when deemed necessary while maintaining the same functionalities and intended use.
Heat-Control
Power supply| 3.7V Li-Poly battery pack (non-replaceable)
Charging port| micro-USB
Charger voltage (not included)| 5V DC (±5%)
Minimum charger current (not included)| 0.5A
Operating temperature| 0–40°C
Storage temperature (standby mode)| -10–25°C
Maximum water temperature| 90°C
Temperature measuring accuracy| 0.5°C (within 0–40°C range)
Regulator class| Type 1 class
Device Firmware Class| A-grade
Motor protection| Impedance Protected
Actuator action| Linear variable position actuator
Actuator stroke| 5mm
Purpose of control| Operating control
Construction of control| Integrated control
Degree of protection by enclosure| IP20
Classification of control according to protection against electric shock|
Class III
Action type| type 1
Control pollution degree| pollution degree 2
Rated impulse voltage| 330V (when connected to the USB power supply)
Dimensions (Diameter x Length)| 56 x 74 mm (without the adapter); 56 x 87 mm
(with the adapter)
- The Radiofrequency of the individual device must be the same as your Z-Wave controller. Check the information on the box or consult your dealer if you are not sure.
- Charger type: Unit shall be supplied by a source certified as Limited Power Source (LPS) as defined in clause 2.5 of IEC60950-1 2nd edition + Amd. 1 + AMD. 2.
- SELV power supply (USB supply) is used only for battery charging. The device does not operate the valve during the charging.
Heat-Control (radio transceiver)|
---|---
Radio protocol| Z-Wave (500 series chip) Bluetooth
Frequency band| 868.0-868.6 MHz
869.7-870.0 MHz
2402-2480 MHz (for communication with Temp-Control)
Max. transmit power| 6dBm (Z-Wave) 7dBm (Bluetooth)
(*) The transceiver range is strongly influenced by other devices operating at the same frequency with the continuous transmissions, such as alarms and radio headphones which interfere with the control unit transceiver.
Temp-Control
Power supply| CR2032, 3.0V battery (included)
Operating temperature| 0–40°C
Storage temperature| -10–40°C
Temperature measuring accuracy| 0.5°C (within 0–40°C range)
Dimensions (Diameter x Height)| 38×12
Frequency band| 2402-2480 MHz
Max. transmit power| 1dBm
- Using batteries other than specified may result in an explosion. Dispose of properly, observing environmental protection rules.
- CR2032 coin cell battery is harmful if swallowed!
PRODUCT DISPOSAL
This product is an integral part of the automation and therefore must be
disposed of together with the latter. As in installation, also at the end of
the product lifetime, the disassembly and scrapping operations must be
performed by qualified personnel. This product is made of various types of
material, some of which can be recycled while others must be scrapped. Seek
information on the recycling and disposal systems envisaged by the local
regulations in your area for this product category.
Caution! some parts of the product may contain pollutants or hazardous
substances which, if disposed of in the environment, may cause serious damage
to the environment or physical health. As indicated by the symbol alongside,
disposal of this product in domestic waste is strictly prohibited. Separate
the waste into categories for disposal, according to the methods envisaged by
current legislation in your area, or return the product to the retailer when
purchasing a new version.
Caution! local legislation may envisage serious fines in the event of
abusive disposal of this product.
DECLARATION OF CONFORMITY
Hereby, Nice S.p.A., declares that the radio equipment type Heat-Control is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
http://www.niceforyou.com/en/support
Nice SpA Oderzo TV Italia info@niceforyou.com
www.niceforyou.com
IS0856A00EN_05-03-2022
Documents / Resources
|
FIBARO FGT-001 Temperature
Controller
[pdf] Instruction Manual
FGT-001, Temperature Controller, FGT-001 Temperature Controller
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>