Shenzhen Intelligent Energy MP1000 Portable Power Station User Manual
- June 6, 2024
- Shenzhen Intelligent Energy
Table of Contents
- Shenzhen Intelligent Energy MP1000 Portable Power Station
- Safety instructions
- Product Recharging
- Product Maintenance
- Feature details
- Function buttons
- LCD features
- Details displayed on LCD
- Operating instructions
- Troubleshooting
- Maintenance and warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Shenzhen Intelligent Energy MP1000 Portable Power Station
Safety instructions
Read the following instructions to ensure safety before using. Improper use may result in fire, property damage, or personal injury.
- Product use:
- DO NOT use any inappropriate power cords.
- DO NOT place the unit close to or in a fire on expose it to heat. Keep out of direct sunlight.
- DO NOT charge, use or store the unit in a bathroom or in an area exposed to rain or moisture. Do not drop the unit into the water. If the battery in the unit comes into contact with water, it may cause chemical decomposition of the battery. This may cause the battery to catch fire or explode.
- Never use or charge swollen, leaky, or damaged batteries. If your battery is abnormal, contact us to get support.
- Never install or remove a battery from the unit when it is turned on.
- DO NOT use the batteries in strong electrostatic or electromagnetic environments. Otherwise, the battery control board may malfunction and cause a serious accident.
- Never disassemble or pierce the product in any way. Otherwise, it may leak, catch on fire, or explode.
- DO NOT use the product if it was involved in a crash or a heavy bump.
- If the product falls into the water during use,take the product out immediately and put it in a safe and open area. Keep a safe distance from it until it is completely dry. Never use it again and dispose it properly as described in the
- Battery Disposal section below. If the product catches fire, it is recommended to use fire extinguishing equipment in the following order: water or water mist, sand, fire blanket, dry powder, carbon dioxide fire extinguisher.
- DO NOT allow pins, wires or other metal pieces to insert to the device case, outlets or controls. Metal pieces may short circuit the product.
- Avoid collision. DO NOT place heavy objects on the machine.
- Use and store the unit only in a clean and dry environment. Do not use and store in dusty and wet environment.
- If there is dirt on any plug or outlet surface, use a dry cloth to clean it. Otherwise, it will cause abrasion and result in energy loss or inability to charge.
- DO NOT put the machine in a microwave oven or in a pressurized container.
Product Recharging
- DO NOT charge the unit via power supply systems that operate outside of AC100-240V.
- DO NOT charge the unit via solar panel that operate voltage outside of DC12-26V.
- Always use approved attachment charging cables. we take no responsibility for any damage caused by using other brand charging cable.
- When charging, please place the product on the ground with no flammable or combustible materials around. To prevent accidents, never leave the machine unattended during charging.
- DO NOT charge a product immediately after a long heavy load, because the product’s temperature may be too high. DO NOT charge a product until it cools down to room temperature.
- Only charge, use the unit within an ambient temperature of 0 to 40 °C (32~104°F). The ideal charging temperature range is 71ºF to 82ºF(22°C to 28°C).
Product Storage and Transportation:
Keep the product out of the reach of children. If any children accidentally swallow parts, please go to a doctor immediately.
- If a low-battery warning appears, charge the battery before storing it.
- Store the product in dry environments. DO NOT place the product where it may contact with water. Make sure no small metal objects can fall on or around the product while in storage.
- Never transport a product with a battery power level higher than 30%.
Product Maintenance
- Never store the product in environments below -20°C or above 45°C.
- Battery life may be reduced if not used for a long time.
- Fully charge and discharge the battery at least once every 3 months to maintain battery health.
Feature details
- LCD screen display
- DC 5525 output
- Cigarette lighter
- output USB-C output
- 5 USB-A output
- 1000W rated AC output
- Anti-collision strip
- DC input
- PV input
- 10 SOS mode & LED light
- Folding handle
- Wireless charger
- Air Intake vent with the cooling fan
- No user-serviceable parts inside. recommended to fully charge the MP1000 before use.
Button feature
A: MP330 power ON/OFF button B:SOS mode & LED light button C:DC output power ON/OFF button D:USB output power ON/OFF button E: AC output power ON/OFF button
Function buttons
Button A: MP1000 power ON/OFF
Button A is the master switch. Press button A to turn on the power or to shut down the output(s) when not in use.
Button B: SOS mode & LED light
- Function is available no matter the button “POWER ON/OFF ” is activated or not as the following steps :
- Firstly, press button B to turn on the LED light into the LED light mode.
- Secondly, double-click it to turn on the SOS mode.
- Thirdly, press button B back to LED light mode, then press it again, and the light will be turned off.
Button C: DC output power ON/OFF
Pls. make sure the button “POWER ON/OFF” is activated before pressing button C to turn it on; Press button C to shut down the output(s) when not in use.
Button D: USB and wireless charger output power ON/OFF
Pls. make sure the button “POWER ON/OFF” is activated before pressing button D
to turn it on; Press button D to shut down the output(s) when not in use.
The USB-C cable of different devices needs different endorsements of
corresponding protocols, if the USB-C port doesn’t work, try to use the AC
adapter to charge .
Button E: AC output power ON/OFF
Pls. make sure the button “POWER ON/OFF” is activated before pressing Button E to turn on; Press Button E to shut down the output(s) when not in use.
Cooling fan
MP1000 utilizes an internal cooling fan to ensure the product is operating within the appropriate temperature range. MP1000, when it experiences a higher output load, will automatically turn on the fan during discharge or recharging, the fan may operate intermittently to keep the internal temperature within operating range. The fan will likely start when the AC circuit is activated to ensure proper operation.
LCD features
- H: Battery level indicator
- I: Input status
- J: DC outputs status
- K: AC outputs status
- L: USB outputs status
Details displayed on LCD
Battery level indicator
The battery level is provided by percentage of battery
charge corresponding to the number of bars and percentage displayed. The
segments in the battery level correspond to the current state of charge, 0-5%
empty, 6-20% one segment, 21-40% two segments, 41-60% three segments, 61-80%
four segments, and all five are lit when charge level is above 81%.
Provides the user live telemetry data on time to completely charge, or deplete
thebattery based upon the energy entering or leaving the battery.
Highly recommend to fully charge MP1000 when first use. Higher battery level
indicator show, more precise the data will indicate.
Please be aware that this value can adjust multiple times as the energy draw
changes from the connected devices. This is evident during initial activation
of ports with a connected device.
Recommended back to charge the MP1000 when battery indicate less than 20%.
Note that when you first plug in a power source, whether it’s a solar panel or
a wall charger, the MP1000 may take a minute to detect and adjust its charge
circuitry before it starts drawing power from the source.
Input status: The MP1000 is capable of providing input energy in watts.
DC output status: The display will provide output watts of the DC port.
AC output status: The display will provide output watts of the AC port.
Power-saving mode:
when the device enters the input or output state, it will enter the screen-off mode after more than 20 seconds, which does not affect the normal operation of the device. When the output power of the device is less than 5W, the device will go into hibernation after more than 3 hours, and the input can be “awakened” when the input is charged or any button is pressed. When not in use, press the switch button to turn off the output.
Operating instructions
Charging MP1000
Connect the provided AC Wall power adapter to Input, and allow MP1000 to fully
charge prior to use, approx. 5-7 hours. When charging, the LCD Screen will be
illuminated, and the LCD display will provide Battery level Indicator, MP1000
is fully charged when the level is 100%. It is recommended to fully charge
MP1000 every 3 months to maintain the health of the battery pack.
What it powers
How to charge
AC adapter charging
It will take 6-7 hours to charge fully by using the AC adapter we provided.
Solar panel charging
- DO NOT charge the unit via solar panel that operate voltage outside of DC12-26V.
- Place Solar Panels in direct sunlight as much as possible.
- Support 60W/80W/100W/120W/150W Max Solar Panels (Not included), the charging time is determined by the solar light intensity.
12V car charger charging
Use the car charger we provided to charge this unit. The full charge time takes 9-11 hours. When the LCD display shows the battery power of 100%, it indicates that this unit is fully charged.
Powering / charging devices with MP1000
Select the type of outlet required by pressing the output ON/OFF button C/D/E. The output port will not function until the appropriate button is pressed to activate the port. When activated, the indicator on the button will illuminate green, indicating that the output(s) are active, and the LCD display will turn on and provide details on the charging output. The LCD Screen will automatically shut down when no outputs are activated.
Pass-through charging
The advanced battery management system of the MP1000 allows it to charge a connected device via AC and DC output & USB output while charge the Mp1000.
Overload condition
- If an overload condition occurs on the output port, MP1000 will:
- Automatically turn off AC output(6)power.
- The blue indicator light of LCD screen(1)still illuminated.
- DC output status J still the same status as usual.
Do following
Check the input charge cable. The port will be efficient when the input charge
cable meets the specification outlined in the general specifications section.
Only charge MP1000 with provided AC wall power adapter.
MP1000 accessory list
Recommend to use Solar p 100W/120W panel (not included).
Equipment cleaning
- Please make sure that the device is disconnected from all input power and output devices. Wipe with a clean, dry, non-soft cotton cloth. Removing any foreign objects, dirt or other obstructions on the vents on both sides. When cleaning foreign objects in the side vents, do not allow debris, dirt or other Blockage enters the equipment.
- Do not use corrosive cleaners or solvents.
- Do not use compressed air to clean the side cooling vents, as it will cause foreign particles to enter the interior and cause a short circuit.
- Note: To avoid the risk of electric shock, do not use metal objects to clean the ports.
Storage
If it will be stored for more than 1 month, please charge it to 50% capacity
and keep it indoors, at normal temperature, and the maximum storage time shall
not exceed 6 months. please keep away from direct sunlight (see the general
specification section).
Excessive temperature will lead to reduced service life, overheating, and
fire. Extremely cold conditions below the specified storage range can also
impair the performance and service life of the equipment. Please keep away
from corrosive chemicals and gases.
After taking it out of storage, perform a visual inspection to ensure that the
appearance of the equipment and all accessories are qualified. Checking the
vents on the intake and exhaust sides to make sure they are free of foreign
objects. Allowing the device to return to the environment before charging or
other devices.
Notice
Transportation: The power station meets all legal requirements for the transportation of dangerous goods. The capacity of the lithium battery pack exceeds 100Wh. According to international standards Standard, if the power station is transported by air, it must be transported in accordance with IATA standard packaging. The instructions and labeling requirements of the International Air Transport Association and related declarations must be completed.
Troubleshooting
-
The device does not discharge
-
Check whether the output buttons are activated ;
-
Check whether the total output power exceeds the rated output power;
-
Check whether the temperature of the equipment is too high.
The device can not be charged -
Confirm that the wall plug power adapter’s cord is inserted fully into the DC Input.
-
Confirm that the AC wall plug power adapter is the charger provided with MP1000.
-
If the input does not comply with the requirements located in the general
-
specifications section, the low power range 0% to 10%may be displayed on the LCD.
-
If the device cannot be charged immediately after it is discharged, please wait for an hour and try again, it may enter the over-temperature protection.
Maintenance and warranty
Maintenance
- Check as needed. If the MP1000 energy storage power supply cannot be used regularly, please charge and discharge it every 3 months under normal temperature to keep the service life. Regularly check all ports and wall chargers for any debris, dirt, damage, and corrosion.
- Do not disassemble the device privately.
- Do not cover the equipment with towels, clothes or other items. Regularly observe the side vents for dust and foreign matter, and clean them according to the cleaning procedures specified in the manual.
Disposal/recycling
Do not put the device and its accessories in the trash can. Items must be
properly handled in accordance with local laws and regulations.
For additional information, please see www.epa.gov.
Affirm
© Copyrighted equipment. all rights reserved. All trademarks cited here are
the property of their respective owners. The information contained in this
agreement is subject to change without notice. We are not responsible for
technical or editorial errors or omissions contained in this agreement.
First edition: Aug. 2021.
We assure the original consumer purchaser that our products are free of
defects in workmanship and materials during the applicable warranty period
determined in the “Warranty Period” section below, subject to the exclusions
set third below.
This warranty statement sets total and exclusive warranty obligations. We will
not assume, nor authorize any person to assume for us any other liability
related to the sale of our products.
Warranty period
The warranty period is 12 months, and the warranty period is calculated by the original consumer purchaser from the date of purchase. In order to determine the start date of the warranty period, a sales receipt from the first consumer purchase or other reasonable documentary proof is required.
Repair processing
We will repair or replace any products that cannot be operated due to defects in workmanship or materials within the applicable warranty period. If a valid claim is filed within the applicable period, we can choose:
- Replacement product.
- It can be exchanged with products of equal value. The replacement product bears the remaining warranty period of the original product or replaces it (90) days from the date of warranty, whichever is greater. The customer is responsible for the shipping cost of the return.
Exclusions
The warranty does not apply to 1) any product that is modified, misused, abused, damaged by accident, or used for anything other than normal consumer use as authorized in the current product literature or 2) any product purchased through an online auction house. The warranty does not apply to the battery cell unless the battery cell is fully charged by you within seven days after your purchase the product and at least every 6 months thereafter.
After-sales service
For after-sales maintenance service, please contact our customer service team.
Notes
-
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
-
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.
FCC ID: 2A4UPMP1000MV1000
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>