PASSION FOR PRECISION
RED DIGITAL
Operating instructions
Scope of delivery for RED DIGITAL/REDM DIGITAL:
- RED DIGITAL/REDM DIGITAL
- AAA batteries
- Quick Starter
Scope of delivery for HORIZON GREEN BASIC:
- RED LASER DIGITAL
- AAA batteries
- Quick Starter
Operating instructions
RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL (original version)
About this manual
Congratulations on the purchase of your new RED DIGITAL, REDM DIGITAL, RED
LASER DIGITAL!
You have acquired a SOLA measurement instrument, which can make your work
easier, faster, and more precise.
To utilize the complete functionality range of this measurement instrument,
and to ensure a safe operation, please observe the following instructions:
- Please read this operating manual before commissioning the device.
- Always keep the operating manual near the device.
- Only hand over the device to other persons together with the operating manual.
- Never render the attached warning signs unreadable.
General information
Signal words and their meaning
DANGER
For an imminent danger that could lead to serious injury or death.
WARNING:
For a possibly dangerous situation that could lead to serious injury or death.
CAUTION
For a possibly dangerous situation that could lead to slight injury or
property damage.
NOTE:
For application notes and other useful information.
Pictograms and other information
Warning signs
Warning of dangers in general
Symbols
| Read the operating manual before use
---|---
| Dispose of batteries and devices separate from household waste
| Do not throw batteries into the fire
| Do not heat the battery above 60 °C
| Class 2 laser device
| Do not look into the laser beam
Description
Device components, display, and operating elements
RED DIGITAL/REDM DIGITAL
- Acrylic glass block vials
- Gradient module
- Gradient module battery compartment
RED LASER DIGITAL
- Laser output aperture
- Acrylic glass block vials
- On/off switch
- Laser battery compartment
- Magnetic adapter for installing an angled prism or beam splitter
- Laser warning label
- Gradient module
- Gradient module battery compartment
Gradient module
- On/Off switch / Display light
- On/Off switch acoustics (signal at 0° and 90°)
- Hold function (measurement is retained by pressing once) / Toggling between ABS (absolute) and INC (incremental)
- Display switch ° / mm/m / % / in/ft
- Arrows show in which direction the spirit level is to be moved
- Display ° / mm/m / % / in/ft
- Display in the case of low battery voltage
- Display of ABS or INC
Technische data
Gradient module
Max. measurement tolerance
-0° – 90°
-1° – 89°| ± 0.05°
± 0.10°
---|---
Protection class| IP 65
Power supply| Power supply 3 x 1.5 V AAA batteries
Battery life (at 20°C)| 30 h (if display light switched off, approx. 80 h)
Permissible temperatures
Operating temperature
Storage temperature| -10°C to +50°C
-20 °C to +70 °C
Laser
Working range
-Laser point| r = 30 m*
---|---
Max. measurement tolerance
-Laser beam to the measuring surface -Laser beam to the lateral surface| ± 0.5 mm/m
± 1.0 mm/m
Point size
-At 10 m
-At 20 m| approx. 6 mm
approx. 10 mm
Power supply| Power supply 2 x 1.5 V AAA batteries
Battery life (at 20°C)
-Micro (AAA) batteries| 500 h
Permissible temperatures
Operating temperature
Storage temperature| -15 °C to +50°C
-20 °C to +50°C
Laser diode lines/points| 635–650 nm < 1 mW
Laser class| Laser class 2, DIN EN 60825-1 and FDA 1040.10
*… depending on the ambient conditions in the workplace. Subject to modifications (drafts, descriptions, and technical data)
Safety Instructions
AREA OF RESPONSIBILITY
Manufacturer
SOLA is responsible for delivering a safe and immaculate product, including
the operating manual and original accessory equipment.
SOLA-Messwerkzeuge GmbH
Unteres Tobel 25
A-6840 Götzis| KESON LLC
810 N. Commerce St. Aurora
Illinois 60504|
---|---|---
Operator
The operator is responsible for the correct use of the product, the
deployment of its employees, training
for its employees and the operational safety of the product.
- The operator understands the safety information which is stated on the product and the instructions in the operating manual.
- The operator shall comply with the standard local regulations relating to safety and accident prevention regulations as well as worker protection laws and regulations.
- The operator shall immediately notify SOLA if safety-related issues should arise relating to the product or during its utilization.
- The operator shall ensure that the product is not utilized any further if defects become evident, and they will have the product repaired professionally.
Improper Use
- Use of the device and the accessories without instruction.
- Use of third-party accessories or additional equipment.
- Use outside of the intended limits (see Chapter 3 / Technical data).
- Use under extreme temperature fluctuations without adequate acclimatization.
- Disabling of safety devices and removal of hazard notices and labels.
- Unauthorized opening of the device.
- Performance of modifications or alterations to the device or the accessories.
- Deliberate blinding of third parties.
- Inadequate safeguarding at the installation site.
Utilization limitations
The RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL is suitable for use in an atmosphere that can be permanently inhabited by humans.
- Do not operate the product in explosion-prone or corrosive environments.
- Inform the local safety authorities and safety experts before working in hazardous environments, in close proximity to electrical installations or similar surroundings.
Usage Hazards
General
WARNING
Missing or incomplete instructions may result in improper or incorrect use.
This can cause accidents with serious damages to persons, property, assets,
and the environment.
- Follow the manufacturer’s and operator’s safety instructions.
- Protect equipment and accessories from being accessed by children.
WARNING
Blinding by laser radiation can indirectly lead to serious accidents,
especially for people who are driving a vehicle or operating machinery. Do not
look into the laser beam.
- Do not set up the laser beam and the laser plane at eye level or aim at people.
CAUTION
A fall, longer storage, transportation, or other mechanical effects can lead
to erroneous measurement results. Check the unit for damage before use.
Do not use damaged equipment.
- Repairs must only be performed by SOLA.
- Before use, check the accuracy of the device (see Chapter 8 / Checking the accuracy).
Charger / batteries / rechargeable batteries
DANGER
Mechanical damage can cause batteries to leak, explode or catch fire or
trigger the release of toxic substances.
- Batteries and rechargeable batteries may not be opened or exposed to mechanical loads.
- Damaged batteries, chargers, and charging stations may not be used.
- Repairs must only be performed by SOLA.
WARNING
High ambient temperatures and immersion into liquids can cause batteries to
leak, explode or catch fire or trigger the release of toxic substances.
- Protect batteries and rechargeable batteries from mechanical damage during transport.
- Do not overheat batteries and rechargeable batteries or expose them to fire.
- Avoid the ingress of moisture into batteries and rechargeable batteries.
- Do not use damaged batteries or rechargeable batteries. Ensure proper disposal (see Chapter 12 / Disposal).
WARNING
A short-circuit or unintended use can cause batteries to overheat and create
an injury or fire hazard.
- Do not transport or store batteries in the pockets of garments.
- Do not bring the battery contacts in contact with jewelry, keys, or other electrically conductive objects.
- Do not charge the batteries.
- Do not discharge the batteries through short-circuiting.
- Do not solder the batteries in the device.
- Do not mix old and new batteries, and do not mix batteries from different manufacturers or with a differing type designation.
WARNING
If disposed of improperly, third parties may be seriously injured and the
environment polluted.
Burning plastic components generates toxic fumes which may impair health.
Batteries/rechargeable batteries may explode if they are damaged or heated
excessively, and thereby cause poisoning, burning, corrosion, or environmental
contamination. If disposed of negligently unauthorized persons are able to use
the product improperly.
- The product may not be disposed of together with household waste. Dispose of the device and accessories properly (see Chapter 12 / Disposal).
- Protect the product against access by unauthorized persons at all times, especially children.
ELECTROMAGNETIC COMPATIBILITY (EMC)
Electromagnetic compatibility is the ability of the product to function in an
environment where electromagnetic radiation and electrostatic discharge are
present, without causing electromagnetic interference to other devices.
Interference with other devices by RED LASER DIGITAL
Although the product meets the strict requirements of the relevant directives
and standards, SOLA can not completely exclude the possibility of interference
with other devices (for example, when using the product in combination with
third-party devices, such as field computers, personal computers, wireless
devices, mobile phones, certain cables or external batteries).
- When using computers and radio equipment, be sure to observe the vendor-specific information about electromagnetic compatibility.
- Only use original SOLA equipment and accessories.
Interference with RED LASER DIGITAL by other devices
Although the product meets the strict requirements of the relevant directives
and standards, SOLA cannot entirely exclude the possibility that intense
electromagnetic radiation in the immediate vicinity of radio transmitters,
two-way radios, diesel generators, etc. may distort the measurement results.
- When performing measurements under these conditions, check the plausibility of the results.
FCC statement
Warning:
The user is cautioned that changes or modifications not expressly approved by
the party responsible for compliance could void the user‘s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. The following two
conditions apply for operation:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
NOTE:
This device has passed the compliance test for limits for a digital class B
device as per Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation.
This device produces and uses radio-frequency energy and can also emit it. If
it is not installed and used according to the instructions, it may cause
harmful interference to radio communication. However, there is no guarantee
that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Realign the receiving antenna or set up in a different location
- Set up the device further away from the receiver
- Connect the device to another socket than that to which the receiver is connected
- Seek advice from the dealership or a technical expert
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ISED statement
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
IC Radiation Exposure Statement:
This equipment complies with FCC and Canada radiation exposure limits set
forth for an uncontrolled environment. This transmitter must not be co-located
or operating in conjunction with any other antenna or transmitter.
Use of the product with Bluetooth
WARNING:
Electromagnetic radiation can cause disturbances in other equipment, in
installations (e.g.
medical ones such as pacemakers or hearing aids) and in aircraft. It can also
affect humans and animals. Precautions:
Although this product conforms to the most stringent standards and
regulations, the possibility of harm to people and animals cannot totally
excluded.
- Do not use the product near petrol stations, chemical plants, in areas with an increased risk of explosion, and where blasting takes place.
- Do not use the product near medical equipment.
- Do not use the product on airplanes.
- Do not use the product near your body for extended periods of time.
LASER SAFETY / CLASSIFICATION
The RED LASER DIGITAL emits a visible laser point.
The product complies with laser class 2, DIN EN 60825-1, and FDA 1040.10.
Laser Class 2:
When using Class 2 laser devices, the eye is protected by the blink reflex or
aversion reaction in the case of random and short-term exposure.
WARNING
Looking directly into the laser beam with optical aids (such as binoculars,
and telescopes) can be dangerous.
CAUTION
Looking directly into the laser beam can damage the eyes.
Do not look into the laser beam.
Do not aim the laser beam at other people.
Labeling on the device:
- Do not remove the labeling!
Getting Started
Prior to initial set-up, check whether the batteries have been installed correctly in the device. Do not point the laser at people when you switch the device on.
Inserting batteries
- Open the battery compartment cover with an appropriate screwdriver.
- Insert batteries making sure that the poles of the batteries are in the right position.
- Close the battery compartment cover with an appropriate screwdriver.
Only use type 1.5 V AAA batteries!
Remove the batteries if the instrument is not used for an extended period.
NOTE
The intensity of the laser lines can vary depending on the battery quality.
Operation
Switching on/off
-
On:
Press the “On/Off switch / Display light” to switch on the gradient module. -
Off:
Press the “On/Off switch / Display light” for at least 2 seconds to switch off the gradient module.
Display
If the gradient spirit level is used in the inverted position (upside down –
above your head), the display screen turns too so that the measurement can be
read easily.
The display switches off automatically after 5 minutes, as soon as the device
is no longer being moved.
Display light
- Switch on the gradient module (display light is active)
- Press the “On/off switch / Display light” to switch the light on and off.
Acoustic signal
The acoustic signaling is switched on by pressing the “On/off switch for
acoustics”. The closer the gradient spirit level gets to the standard
position, the more rapid the frequency of the acoustic signal.
This function assists you with leveling work, where it is not possible for you
to read the measurement from the display.
Hold function
The current measurement is frozen by pressing the “Hold function” once.
A previously measured value can be “frozen” on the display using this
function. The measurement remains unchanged until the “Hold function” button
is pressed again.
Toggling between ABS and INC
You can toggle between ABS (absolute) and INC (incremental) by pressing the
“Hold function” for more than 2 seconds.
In the “ABS” (absolute) mode, the measurement result is displayed based on the
device calibration.
In contrast, in “INC” (incremental) mode, the measurement result is displayed
based on a relative reference level.
For example, you can take a measurement on a 5° inclined plane in “ABS” mode and then toggle to “INC” function. In doing so, the measurement display is set to 0°. You can now take additional measurements based on this new zero value. To leave “INC” mode, press the button again for 2 seconds.
Changing measurement display
Press the “Display switch” to change between ° / mm/m / % / in/ft.
Changing the display resolution
By pressing the “Hold function” and the “On/off switch / Display light” button at the same time, you can choose between two resolutions: 0.00° or 0.0°.
Bluetooth
Fast and efficient data transfer of measured values can be made directly to a smartphone via Bluetooth.
NOTE
To pair with a smartphone, launch the SOLA Measures App and connect using one
of the function options.
Calibration and adjustment
Calibration of gradient module
Calibration stage 1 based on position 0°
- Place RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL with the measuring surface on a horizontal plane
- Briefly, press buttons and
- Display -1- appears on the screen
- Press the button briefly, display -1- flashes for approx. 5 seconds
- Display -2- appears on the screen
- Rotate RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL 180°
- Press the button briefly, display -2- flashes for approx. 5 seconds
- A measurement display appears on the screen, calibration stage 1 is complete.
Calibration stage 2 is based on a position of 180°
- Place RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL ‘on its head’ and on a horizontal plane
- Briefly press buttons and
- Display -1- appears on the screen
- Press the button briefly, display -1- flashes for approx. 5 seconds
- Display -2- appears on the screen
- Rotate RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL 180° again
- Press the button briefly, display -2- flashes for approx. 5 seconds
- A measurement display appears on the screen, calibration stage 2 is complete.
Calibration stage 3 based on position 90°
- Place RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL with the measuring surface on a vertical plane
- Briefly, press buttons and
- Display -1- appears on the screen
- Press the button briefly, display -1- flashes for approx. 5 seconds
- Display -2- appears on the screen
- Turn RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL by 180°
- Press the button briefly, display -2- flashes for approx. 5 seconds
- A measurement display appears on the screen.
- The RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL is thus fully calibrated.
Adjusting the laser spirit level on the leveling base
Place the device on the leveling base so that the product logo is in front of you (Pos. 0°).
- Adjust the vial to a 0° position.
- Adjust the vial to a 90° position.
- Adjust the vial to a 180° position.
WARNING:
Always work with both screws when adjusting!
Making slight corrections after every turn means no errors occur. These are
sometimes necessary and therefore state of the art.
Maintenance, storage, and transportation
Cleaning
- Wipe off the dirt with a soft damp cloth.
- Check the outlet openings of the laser regularly, and thoroughly clean them if necessary. Do not touch the glass with your fingers.
- Do not use aggressive cleaning agents or solvents.
- Do not immerse the device in the water!
- Clean and dry wet equipment, accessories, and transport containers prior to packaging them. Only pack equipment again when it is completely dry.
- Keep plug connections clean and protected from moisture.
Storage
General
- The equipment may only be stored within the specified temperature limits (see Chapter 3 / Technical data).
- After prolonged storage, check the accuracy of the measuring device before using it.
Batteries/rechargeable batteries
- To store the rechargeable battery remove it from the device or the charging station.
- They should preferably be stored in a dry environment at room temperature (see Chapter 3 / Technical data).
- Protect from moisture and humidity. Dry wet or damp batteries before storage before usage.
- Before storing for extended periods, charge the battery to 80% capacity (see Chapter 7 / Operation). Repeat the process every six months during storage.
- After storage, fully charge the battery.
- Check the battery for any damage before use. Do not use damaged equipment.
Transport
General
The device may be damaged if it falls or is subjected to strong vibrations.
- Never transport the product lose. Always use the original packaging or an equivalent transport container.
- Switch off the measuring device before transporting it.
- Check the unit for damage before use.
Batteries/rechargeable batteries
The operator is responsible for adhering to the regulations and requirements
valid on a national and international level when transporting or sending
batteries and rechargeable batteries.
- Before shipping, remove the batteries from the device.
In principle, li-ion batteries are subject to the requirements for dangerous
goods; nonetheless, they can be transported by the user by road without any
further requirements.
For dispatch via third parties (e.g. shipping companies or air freight),
certain requirements for packaging and labeling must be observed.
- Remove the battery from the device and send it to storage condition (80% capacity).
- Mask open contacts.
- Pack the battery so that it cannot move in the packaging and it cannot be damaged by external impacts.
- Observe other national and international regulations and, if necessary, additional requirements of the respective transport company.
Delivery of contents and accessories
Delivery contents RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL:
RED DIGITAL, REDM DIGITAL, RED LASER DIGITAL
AAA batteries
Quick Starter
ACCESSORIES (optional)
Angle prism WP
Beam splitter ST
Target ZS RED
Laser goggles LB RED
Leveling base NB
Telescopic tripod TST
Elevator tripod KST
Construction tripod BST
Transport protection bag
Further information on accessories can be found at
www.sola.at
Troubleshooting
Error | Possible Cause | Remedy |
---|---|---|
The device is switched on, no display, the screen is not illuminated |
- Battery flat
- Battery inserted incorrectly Device or switch faulty
|
- Replace battery
- Insert battery correctly
- Contact the dealer and have the device repaired
No laser beam function.|
- Battery flat
|
- Replace battery
Display jumps or screen “frozen”|
- Program error
|
- Remove batteries, wait for one minute, reinsert batteries
Irregular display screen|
- Battery power low
|
- Replace battery
Laser lines blink in one-second intervals|
- Battery flat
|
- Replace battery
The device is switched on, the display is lit up but a laser beam is not visible|
- Ambient temperature too high/low
- Laser diodes or laser control faulty
|
- Allow the device to acclimatize
- Contact your dealer and arrange for the device to be repaired
Disposal
If disposed of improperly third parties can possibly be seriously injured and
the environment polluted.
Burning plastic components generates toxic fumes which may impair health.
Batteries/rechargeable batteries may explode if they are damaged or heated
excessively, and thereby cause poisoning, burning, corrosion or environmental
contamination.
If disposed of negligently unauthorized persons are able to use the product
improperly.
Measuring tools, accessories and packaging must be recycled in an
environmentally-friendly manner.
The product as well as the accessories – especially the batteries and
rechargeable batteries – may not be disposed of with household waste.
- Dispose of the device and the accessories properly.
- Only dispose of batteries when discharged.
- Observe the country-specific disposal requirements.
Your SOLA dealership will take back batteries as well as old equipment, and will ensure proper disposal.
Only EU countries
Electric tools must not be disposed of with household waste!
According to European Directive, 2002 / 96 / EC on Waste Electrical and
Electronic Equipment and its transposition into national law, electrical and
electronic equipment that is no longer usable must be collected separately and
recycled in an environmentally friendly manner.
Manufacturers’ guarantee
“The manufacturer warrants to the original purchaser stated on the guarantee
card, freedom from defects of the device for a period of two years, with the
exception of batteries,
from such time as the device is handed over. The guarantee is limited to
repairs and/or replacements at the manufacturer‘s discretion.
Defects that are caused through improper handling by the purchaser or third
parties, natural wear, and optical flaws that do not affect the usability of
the equipment, are not
covered by this guarantee. Claims under this guarantee can only be invoked if
the device is submitted along with the guarantee card, completely filled out
by the dealer, dated, and provided with the company stamp.
If the guarantee claim is justified, the manufacturer shall bear the transport
costs. The duration of the guarantee will not be extended through repair or
spare parts work that is carried out within the scope of the guarantee.
Further claims are excluded unless these are stipulated by the respective
national legislation. In particular, the manufacturer shall not be liable for
any direct, indirect, incidental, or consequential damages, losses, or
expenses in connection with the use or because of the inability to use the
tool for any purpose whatsoever. Implied warranties for the usage or
suitability for a particular purpose are expressly excluded.”
EC conformity declaration
Declaration of conformity
declare under our sole responsibility that the Product(s)
RED DIGITAL
to which this declaration relates is in conformity with the following standards.
EMC
61326-1:2013
61326-2-2:2013
55011:2009+A1:2010
Lasers
61000-6-3:2007
61000-6-3:2007
Radio transfer
301489-1 V2.1.1
301489-17 V3.1.1
300328 V2.1.1
62479:2010
Following the provisions of Directive(s)
Electromagnetic compatibility 2014/53/EU
SOLA-Messwerkzeuge GmbH