Pro FPP14206 2-Channel Digital Timer Installation Guide

June 5, 2024
Pro

**Pro FPP14206 2-Channel Digital Timer

Pro-FPP14206 2-Channel-Digital-Timer-product**

About your Digital Timer

The Digital Timer is designed to work with your existing thermostat, heating and hot water. It can work automatically, or you can adjust it manually to maintain a comfortable indoor environment while minimising energy use and costs associated with heating both your home and the hot water you require.

Features

Energy-saving design: Automatically activates or shuts down your heating and hot water up to six times per day to fit your lifestyle while saving energy costs. Each day of the week can be programmed separately (see pages 8-12).
One-touch comfort control : This allows you to override programmed settings at any time by turning your heating or hot water on or off — or by extending an “on” period by up to three hours.
Holiday button: Turns off your heating and hot water for up to 99 days while you are away, then resumes normal operation when you return (see page 12).
Seasonal clock change: Automatically adjusts the clock for seasonal changes in the spring and autumn to adjust for standard time or daylight savings time.
Lifetime memory: Saves your customized settings indefinitely, even if the mains power supply fails.

Quick reference

Pro-FPP14206 2-Channel-Digital-Timer-fig-1

Date/time settings

  • Pro-FPP14206 2-Channel-Digital-Timer-fig-2To change the date or time, set the slider to DAY/TIME.
  • Use the + or – buttons to set the correct day, then press the OK button. Follow the same procedure to set month, year and time.
  • Date and time are set at the factory and should not need to be changed unless you turn off the automatic daylight savings feature (see pages 21-23).

TIP : While setting the time, press and hold the +/- buttons to change the clock time more rapidly.

Operating modes

  • Press the MODE button repeatedly to select an operating mode. You can set the Hot Water and Heating modes separately, by pressing the appropriate button as shown at left. Both work the same way:
  • Cont : Heating or Hot Water remains on continuously.
  • Auto : In this mode the Digital Timer follows a daily schedule for the Hot Water or Heating, turning each on and off at preset times during the day (see page 8).
  • Once : In this mode the Heating or Hot Water is turned on at the first programmed “On” time of the day, and remains on until the last programmed “Off” time (see page 8).
  • Off: Heating or Hot Water remains off at all times.

Cost-saving programme schedules

  • The Digital Timer is preset at the factory to turn off your home heating and hot water when they’re less likely to be needed. The preset schedules are shown below. To change them, see pages 9-12. (See also two alternate schedules on page 25).
  • To run this schedule (as shown below, or as you’ve modified it), leave the MODE buttons set to Auto. You can make temporary adjustments at any time (without changing the schedule) by pressing the EXTRA HOUR or OVERRIDE buttons (see pages 10-11).

Pro-FPP14206 2-Channel-Digital-Timer-fig-4

To adjust programme schedules

Pro-FPP14206 2-Channel-Digital-Timer-fig-5The Hot Water and Heating schedules must be programmed independently, but the procedure is the same for both.
1 Move slider to HOT WATER or HEATING, then press + or – to adjust the “On” time for Period 1 as shown at left.
2 Press OK to save, then press + or – to adjust the “Off” time for Period 1. Repeat for all time periods.
3 After all Monday time periods are set, press the NEXT DAY button to adjust settings for Tuesday. Repeat for all other days.
To stop programming at any time, move slider to RUN.

SHORTCUT : While programming, press the COPY DAY button to copy settings for the current day and apply them to other days. For example, you can apply Monday settings to other days of the week. After copying, press the NEXT DAY button to select a target day, then press OK.
TIP : To delete an unwanted time period, set identical times for the “On” and “Off” periods.

Temporary schedule overrides

  1. The OVERRIDE buttons work like a simple “on/off” switch. If you press the button when the system is on, it will turn off. If off, it will turn on. The Hot Water and Heating override buttons work independently. Neither affects the other system.
  2. These buttons work only when the MODE is set to Auto or Once (see page 7).
  3. This change is temporary. It does not change the daily programme schedule, which will resume at the next programmed “On” or “Off” time period.

NOTE : See also temporary overrides for extra hours or holidays (see pages 11-12).

Temporary schedule overrides — Holiday

  1. Pro-FPP14206 2-Channel-Digital-TimeThe Holiday feature turns off your heating and hot water while you are away for an extended time (up to 99 days). After the designated time both systems resume normal operation.
  2. With slider set to RUN, press the HOLIDAY button.
  3. Press + or – to select the number of days you will be away (up to 99 days), then press OK to save and exit. The display shows the date you will return and counts down the number of holiday days remaining.To cancel the Holiday mode at any time, press HOLIDAY again.

Advanced features

• Preset programme schedules: The Digital Timer is preset to follow the schedules shown on page 10 (Schedule A) unless you change the settings. However, instead of changing the settings manually, you can choose either of 2 other pre-configured schedules. Schedule B keeps heating and hot water on longer if you’re often at home. Schedule C keeps heating and hot water off longer to reduce energy costs.
• Adjustable time settings: By default, the Digital Timer has 6 time settings per day (3 on, 3 off). You can reduce this to 4 time settings if desired (see page 23).
• Seasonal time change: The clock automatically changes in spring and autumn to correspond with changes to and from daylight savings time (see page 22 to turn off this feature).
• Adjustable clock format: The screen can display time in either AM/PM format (i.e., 2 pm) or 24-hour format (14:00) (see page 22).
• Adjustable backlight: A bright continuous backlight makes the display screen easier to read. You can change its operation so the backlight always remains off or is lit for only a few seconds after each button press (see page 22).
• Mini-Programmer option: This special operating mode is designed to compensate for the inefficiency of some poorly controlled gravity hot water systems, which heat water whenever the home heating system is on. The Mini- Programmer option blocks some operating modes (i.e., “Auto” is not available in Heating, and “Off” is not available in Hot Water). (see page 23).

System installation

Pro-FPP14206 2-Channel-Digital-Time Installation procedure  Disconnect electrical power 2 Install Digital Timer
1. Connect system wiring
2. Restore electrical power
3. Configure system operation 6 Test system operation

NOTE: If you are not experienced in equipment installation and electrical wiring, we recommend that these procedures be done by a professional installer.
DISCONNECT ELECTRIC POWER BEFORE INSTALLATION: Can cause electrical shock or equipment damage.

Remove wall bracket and select location

  • Use a screwdriver to loosen screws and separate the Digital Timer from the wall bracket as shown at left.
  • Select a mounting location about 1.2 to 1.5 metres from the floor where the display can be seen clearly, in an area where the ambient temperature is between 0 and 40º C. Install the wall bracket as shown on page 16.

Mounting options

Pro-FPP14206 2-Channel-Digital-Timer-fig-10Use appropriate wood screws or anchor screws to mount the wall bracket flush against the wall. Use metal screws to mount on an existing junction box.
Pull wiring through the wall bracket and connect to screw terminals as shown on page 17.
1. Make sure electrical power is off.
2.Install wall bracket as shown at left.
3.Connect system wiring as shown then replace Digital Timer on wall bracket and secure with screws.

Connect system wiring

Pro-FPP14206 2-Channel-Digital-Timer-fig-11Connect wiring from your heating and hot water system to the Digital Timer terminal screws as shown at left. See wiring diagrams on pages 18-20.
1.Make sure electrical power is off.
2.Strip insulation to expose about 7 mm of bare wire.
3.Use a screwdriver to loosen terminal screws, insert wires beneath terminal clamp, then tighten screws.

4.Replace Digital Timer on wall bracket, tighten securing screws, then restore electrical power.

NOTE: Keep AC mains supply/load cables separate from equipment wiring.

Wiring diagrams

Pro-FPP14206 2-Channel-Digital-Timer-fig-12 Note 1: This is a Class II device (i.e., double insulated). A parking terminal is available for earth wiring if required.
Note 2: In “Y,” “S” and “W” wiring plans, connections are shown only for basic boilers. For connections to pump over-run boilers, consult boiler manufacturer’s instructions.

Pro-FPP14206 2-Channel-Digital-Timer-fig-13 Note 3: Gravity circulation hot-water systems should be fitted with a suitable hot-water control valve as shown in Plan C on page 19. If this valve is not installed, configure this device as a Mini-Programmer (see page 24).
Note 4: For convenience, wiring is shown with connections made to a 10-way wiring strip in a junction box.

Wiring diagrams

Pro-FPP14206 2-Channel-Digital-Time Note 1: This is a Class II device (i.e., double insulated). A parking terminal is available for earth wiring if required.
Note 2: In “Y,” “S” and “W” wiring plans, connections are shown only for basic boilers. For connections to pump over-run boilers, consult boiler manufacturer’s instructions.

Pro-FPP14206 2-Channel-Digital-Timer-fig-15 Note 3: Gravity circulation hot-water systems should be fitted with a suitable hot-water control valve as shown in Plan C above. If this valve is not installed, configure this device as a Mini-Programmer.
Note 4: For convenience, wiring is shown with connections made to a 10-way wiring strip in a junction box.

Installer setup

Pro-FPP14206 2-Channel-Digital-Timer-fig-16Installer settings allow you to customise how your system works. Check the table to see if any settings need to be changed.
To change installer settings:
1.Set slider to RUN.
2.Press and hold the OK and – buttons together until the screen displays “Set Installer OK?” Press OK to enter installer setup mode and continue.

3.Press OK repeatedly to scroll through functions until you find one you want to change.
4.Press the + or – buttons to change any setting, then press ok to save the new setting and advance to the next function. To exit installer setup at any time, move the slider up, then back down to the RUN position.

Installer setup functions and settings

Pro-FPP14206 2-Channel-Digital-Timer-fig-17

Pro-FPP14206 2-Channel-Digital-Tim

To test the system

After you have installed and configured the Digital Timer, you should check to make sure the system is operating correctly.Pro-FPP14206 2-Channel-Digital-
Timer-fig-191. Set the Heating and Hot Water operating modes to AUTO
2. Press the Heating and Hot Water OVERRIDE buttons to turn the heating and hot water on. The indicator lights should be lit. In case of difficulty.

3. Press the Heating and Hot Water OVERRIDE buttons again to turn the heating and hot water off.
4. Check to ensure the factory-set date and time are correct.

Alternate programme schedules

In addition to the default programme schedule shown on page 8, you can set the system to run either of the schedules shown below. Either schedule can be changed as described on pages 9 12.Pro-FPP14206 2-Channel-Digital-Timer-
fig-20Pro-FPP14206 2-Channel-Digital-Timer-
fig-21

In case of difficulty

Pro-FPP14206 2-Channel-Digital-Timer-fig-21

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pro User Manuals

Related Manuals