xylem FLXI2102 FlexNet SmartPoint Module User Guide

June 5, 2024
xylem

xylem FLXI2102 FlexNet SmartPoint Module

xylem-FLXI2102-FlexNet-SmartPoint-Module-PRODUCT

The Sensus FlexNet™ SmartPoint® module provides wireless communication capability to electric utility meters. The Aclara i210+c™ meter is an electronic, single-phase or network, demand and time- of-use (TOU) electricity meter intended primarily for residential applications.

Technical Overview

  • The FlexNet communications network offers a simple, reliable, and secure system that is economical for mass meter deployments, strategic deployments, and rural applications while providing a multi-application solution for all AMI end points.
  • The FlexNet network enhances the i210+c meter by providing AMI capability.
  • The FlexNet SmartPoint module is a printed circuit board that provides wireless communication capability to the Aclara i210+c electric meter. The SmartPoint module interrogates the meter registers on a programmable interval from five minutes to daily readings. The SmartPoint module then transmits the meter consumption and status information at regular intervals.
  • The module mounts into the existing i210+c meter and acts as a “third party AMR board.” It is designed to mount mechanically into the meter with no additional mechanical modification required.
  • The module communicates via the FlexNet fixed wireless telemetry network to provide electric meter readings and diagnostic data from the meter to the utility provider via radio.
  • The module contains both a receiver and transmitter to allow for two-way communications over the FlexNet network.

Specifications

The i210+c meter with the FlexNet module will have a visible label containing the following information:

  • Contains Model: FLXI2102
  • Contains FCC ID: SDBFLXI2102
  • Contains IC: 2220A-FLXI2102xylem-FLXI2102-FlexNet-SmartPoint-Module-FIG-2

Warnings & Hazards

WARNING Sensus devices are for professional installation only. They are to be serviced by professional personnel only. This product is NOT for consumer installation or servicing. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different form that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help  WARNING

If you are not sure of the rated power of your radio, contact your Sensus representative or dealer and supply the product model number found on the product label. If you cannot determine the rated power out, then assure 3-feet separation from the body to the device.

WARNING
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO QUALIFIED SERVICE PERSONNEL.

RADIATION HAZARD
In order to satisfy the FCC RF exposure limit for transmitting devices, a separation distance of 20cm (7.87 inches) or more should be maintained while operating the Sensus FLXI2102. To ensure compliance, operation at closer than this distance is not recommended. This minimum safe distance is required between personnel and the antenna of this device.

RADIATION HAZARD
In order to satisfy the ISED RF exposure limit for transmitting devices, a separation distance of 27cm (10.63 inches) or more should be maintained while operating the Sensus FLXI2102. To ensure compliance, operation at closer than this distance is not recommended. This minimum safe distance is required between personnel and the antenna of this device. Afin de satisfaire à la limite d’exposition RF pour les appareils de transmission, une distance de séparation de 27cm (10.63 pouces) ou plus doit être maintenu pendant le fonctionnement du Sensus FLXI2102. Pour assurer la conformité, un fonctionnement à distance inférieure à celle est pas recommandée. Cette distance minimale de sécurité est nécessaire entre le personnel et l’antenne de cet appareil. xylem.com SENSUS | 637 Davis Drive | Morrisville, NC 27560 | 800.638.3748 | sensus.com

References