zokop YPO2-09C Portable Air Conditioner User Manual

June 5, 2024
zokop

zokop YPO2-09C Portable Air Conditioner

Thank you for selecting this super quality air-conditioner. Please keep this User’s Manual properly for future reference. Read the User’s Manual carefully before operating this unit.

Important Safeguards

Important safeguards:

  • This air-conditioner is suitable for indoor use only rather than for other occasions.
  • Rated operating range: this unit shall be connected to 220-240V / 50Hz power output end.
  • The air-conditioner shall be installed in accordance with the wiring rules of local grid to ensure proper grounding. Should you have any question about electrical installation, follow the User’s Manual or have the installation done by professional electrician whenever necessary.
  • Please put this unit in a flat and dry place and keep it at least 50cm away from surrounding objects or walls.
  • Once the air-conditioner is installed, ensure that the plug wire is in good condition and inserted firmly into the power socket and always ensure that the power cord is arranged in order to prevent the personnel from stumbling over it or the plug from being pulled out.
  • Do not insert any object into the air inlet/outlet of the air-conditioner. Be sure to keep the air inlet/outlet of the air-conditioner unblocked.
  • Where there is the need to install a drain pipe, ensure that the connection of the drain pipe is in good condition without flexure.
  • When adjusting the horizontal/vertical louver at the air outlet, turn it slightly by hand to avoid damage of the louvre.
  • Keep the unit in an upright position when moving it.
  • Keep this unit away from gasoline, flammable gases, oven or other heat sources.
  • Do not dismantle, inspect or modify the unit without authorization as this may result in fault of the unit, and even bodily injury & property damage; to avoid dangers, if the unit is faulty, be sure to have it repaired by the manufacturer or professionals.
  • Do not install and operate this air-conditioner in a bathroom or other wet environments.
  • Do not allow the children to play with this machine. Closely supervise the children or disabled people when this unit is in use.
  • Do not turn off this unit by removing the plug.
  • Do not place such objects as cups on the unit to prevent water or other liquids from spilling into the air-conditioner.
  • Do not use pest control aerosol or other flammable substances near the air-conditioner.
  • Do not wipe or wash the air-conditioner with chemical solvents such as gasolines and alcohols, etc. Before cleaning the air-conditioner, be sure to turn off the power supply and wipe it with soft semi-wet cloth; if the machine is indeed very dirty, wipe it with neutral cleaner.

Recommendation:
Do not operate this unit if the ambient temperature is greater than 35 in the cooling mode or lower than 5 in the heating mode.

Function Description

This series of mobile air-conditioners are available in cooling only and cooling & heating models of different sizes. The cooling only models offer the cooling, dry, air blowing and sleep functions; the cooling & heating models offer the cooling, dry, air blowing and heating functions. The speed of the fan is adjustable between high fan speed and low fan speed, the temperature setting range is 17-300C, and various protection functions such as (24h) timed ON/OFF setting.

Features and Parts

Features
  • Brand new appearance, compact structure with a sense of streamline.
    ··The appearance of the unit is beautiful and elegant; the remote control can be placed on the right of the handle at the back of the unit, and the remote control features user-friendly memory design.
    ··The structure of the power cord at the back and the universal jack design can better protect the power cord.

  • The position of the outdoor connector is high to allow for convenient assembly and smooth air flow of the heat exhaust hose.

  • Timed start/shutdown function, unique start/shutdown music.

  • 3-minute delay compressor restart protection function, multiple other protection functions.

  • The free snap-fit design of the heat exhaust hose allows for more convenient installation of the unit.

Parts:


  1. Control panel
  2. Horizontal louvre
  3. Vertical louvre
  4. Air outlet frame
  5. Vertical Louvre connecting lever
  6. Caster
  7.  Horizontal louvre connecting lever
  8. Main vertical louver
  9. Front shell
  10. Handle position (right side: remote control storage area)
  11. Back shell
  12. C shape bucke of the heat exhaust hose snap
  13. Power cord
  14. Lower air duct bottom
  15. Wire-winding post
  16. Drain cap
  17. Evaporator filter mesh
  18. Evaporator filter frame
  19. Radiating fine mesh
  20. Condenser filter mesh
  21. Condenser filter frame
  22. Base plate
  23. Remote control
  24. Heat exhaust hose short connector
  25. Heat exhaust hose
  26. Window sealing board assembly

Installation Adjustment

Installation

Warning: leave this mobile air-conditioner in an upright position for at least 2 hours before first use.
This air-conditioner may be moved indoor conveniently; leave the air- conditioner in an upright position while moving it. The air-conditioner shall be placed on a flat ground surface. Do not install or operate this air- conditioner in a bathroom or other wet environments.

  1. Assembly of the heat exhaust hose and heat exhaust hose short connector (as shown in Figure 1)

    1). Take out the heat exhaust hose short connector and heat exhaust hose, and remove the plastic bag.
    2). Pull the few turns at the end of the heat exhaust hose apart, screw the round end of the heat exhaust hose short connector counterclockwise into the heat exhaust hose to form the heat exhaust hose assembly (as shown in Figure 2).
    Note: 1. The heat exhaust hose and heat exhaust hose short connector shall be screwed into place and the heat exhaust hose shall be screwed in at least 3 turns.

  2. Installation of the C shape buckle of the heat exhaust hose and unit

    1). Take out the C shape buckle of the heat exhaust hose and remove the plastic bag.
    2). Point the rotary hole at the end of the heat exhaust hose snap toward the rotation shaft of the back shell and slide it onto the back shell in accordance with the snap joint direction of the rotation shaft on the back shell (as shown in Figure 3).
    Note: 1. When the end snap joint at the end of the rotation shaft of the back shell sticks out of the snap, it means that the heat exhaust hose snap has been slided into place.
    3). Rotate the C shape buckle of the heat exhaust hose that is slided into place counterclockwise to clip the snap joint of the C shape buckle of the back shell successfully through the guide of the slide way of the back shell (as shown in Figure 4).
    Note: 1. Do not rotate the C shape buckle of the heat exhaust hose if it is not slided into place as this may damage the rotation shaft of the back shell and the C shape buckle of the heat exhaust hose.

  3. Installation of the heat exhaust hose assembly and unit
    1). Pull the end of the heat exhaust hose apart by several turns;
    2). Hold the end handle of the C shape buckle of the heat exhaust hose with the left hand and the heat exhaust hose short connector with the right hand, put one end of the heat exhaust hose that is pulled apart onto the snap of the lower air duct bottom, press the C shape buckle of the heat exhaust hose with the left hand by force so that the C shape buckle of the heat exhaust hose clips the snap joint of the back shell (as shown in Figure 5).
    Note: 1. The end of the heat exhaust hose must reach one step inside the bottom of the lower air duct (as shown in Figure 6).
    2. The few turns at the end of the heat exhaust hose must be snapped in the snap of the lower air duct bottom.
    3. The C shape buckle that clips the heat exhaust hose must clip the back shell and heat exhaust hose firmly.

    3). Hold the unit with one hand and the heat exhaust hose short connector with another hand; or both people cooperate with one person holding the unit and the other person pulling the heat exhaust hose to prolong the heat exhaust hose gently.
    Note: 1. Do not separate the heat exhaust hose assembly from the unit.
    2. Do not tilt the unit when pulling apart the heat exhaust hose.

  4. Installation of the window sealing board assembly
    2). Half open the window and mount the window sealing board assembly onto the window, either vertically or horizontally (as shown in Figure 7 and 8).
    3). Pull apart the parts of the window sealing board assembly, adjust the distance of the window sealing board assembly pulled apart so that the two ends of the assembly come into contact with the window frame, and fasten the parts of the assembly with copper screws.

  5. Installation of the unit
    1). Move the machine with the heat exhaust hose assembly installed before the window and keep the unit at least 50cm away from the walls or other objects. (As shown in Figure 9).

    2). Snap the flat end of the heat exhaust hose short connector into the elliptical hole of the window sealing board assembly (as shown in Figure 10 and 11).
    Note: 1. The flat end of the heat exhaust hose short connector must be snapped into place.
    2. The heat exhaust hose may not be bent and shall be free from significant (greater than 45°) flexure, and the heat exhaust hose shall be ventilated properly.

    Important notes:
    The exhaust hose is 280mm-1500mm long and this length is determined based on the specification of the air-conditioner (s). Do not use prolonged hose or replace with other different hoses as this may affect the functions of the air-conditioner. The exhaust must be smooth and the air-conditioner may overheat if the exhaust is obstructed.

BEST INSTALLATION

Control Setting

One. Operation instructions of the control panel

  1. Select the operation interface depending on the models and functions. The operation interfaces of the cooling only and cooling & heating models are as follows:
    1). Cooling only model

    2). Cooling & heating model:
Operation instructions:

1). When the unit is energized for the first time, the buzzer will play the energizing music, the double 8 display area will display the ambient temperature value, and the temperature display range is 10i35¥. H is indicated if the temperature is higher than 35¥. L is indicated when the temperature is lower than 10¥ and the unit enters the standby state.
2). ON/OFF button: used to start/shut down the unit. Upon start, the power indicator displays the green light; after the ON/OFF button is pressed to start the unit, the buzzer plays the startup music, the unit first enters the cooling mode, the double 8 area displays the ambient temperature. The fan speed is high. In the meanwhile, the power indicator displays the green light and the high indicator illuminates. This button may be pressed in the start state to shut down the unit, all loads stop working, the buzzer plays the shutdown music and the unit enters the standby state; When the unit is started again, it will operate in accordance with the status prior to shutdown.
3). Mode button:
a) Cooling only models: press this button to switch between the cooling, air supply, dry and sleep modes. In the meanwhile, corresponding cooling, air supply, dry and sleep mode indicators will illuminate.
b) Cooling & heating models: press this button to switch between the cooling, air supply, dry and heating modes. In the meanwhile, corresponding cooling, air supply, dry and heating mode indicators will illuminate.
c) In the dry mode, if the ambient temperature ¥, the compressor will start. Then, the unit is controlled in the following manner: when the ambient temperature ¥, the compressor shuts down. When the ambient temperature rises to be 17¥, the compressor starts again. The start/stop of the compressor meets the requirement for 3-minute protection time. The fan is forced to switch to low level.
d) In the sleep mode, this unit is performing the cooling function. After operating two hours, the set temperature increases 1¥ automatically. After operating for another 2 hours, the set temperature will increase 1¥ again. Then, the set temperature will not change and the fan is forced to switch to low level.
4). Fan button: the fan may operate in the following manners: a) In the cooling, heating and air supply mode: highlowhigh… and so on. b) Switching between the cooling, air supply and heating modes: maintain the fan speed of the previous mode.
5) Timer button:
a) Upon start, press the Timer button to enter timed shutdown. Upon shutdown, press this button to enter timed start. In the meanwhile, the timer indicator will illuminate.
b) Press the Timer button to enter the timing function (timed start/timed shutdown).
Adjust the up or down button to set the timing time. The time will cycle in the order of 1 2 3 ……24 0 1 hours or 24 23 22 ……1 0 24 hours. The adjustment time of the timing function is relative time.
c) After timed start is set, once the timed start time is reached, the unit will start. In the meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
d) After timed shutdown is set, once the timed shutdown time is reached, the unit will shut down. In the meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
e) Only the last setting of the timing function is valid and valid once only.
f) ON/OFF operations caused by the button or remote control will clear all timing settings.
g) Once the timing is determined, if the timer button is pressed once, it is possible to query the remaining timed start/shutdown time. If the timer button is pressed twice continuously within 5s, it is possible to cancel timing.
6). The up button and down button may be used to change the set value of the temperature, as follows: The up button and down button may be used to change the set value of the temperature. Press the up button or down button when displaying the value of the ambient temperature and the ambient temperature value display area will change to display the set value of temperature (the unit will not respond to this operation in the air supply and dry modes).
a) In the cooling and heating modes, the temperature setting range is 1730.
b) Press the up button and down button simultaneously to switch between the Fahrenheit degree and Celsius degree. When the Celsius degree is displayed, the Celsius degree indicator illuminates; when the Fahrenheit degree is displayed, the Fahrenheit degree indicator illuminates.

Two. Operation instructions of the remote control
The operation instructions of the buttons of this simple remote control are as follows:

  1. Power button: press this button to turn on/off the unit;
  2. Timer button: upon shutdown, press this button to set timed start; upon start, press this button to set timed shutdown.
  3. High button: press this button to allow the unit to operate in the high fan speed state (except in the dry and sleep modes);
  4. Low button: press this button to allow this unit to operate in the low fan speed state;
  5. Up button: press this button to increase the temperature and timing value;
  6. Down button: press this button to decrease the temperature and timing value;
  7. — F button: press this button to switch between the Celsius degree and Fahrenheit degree;
  8. Cool button: press this button to set this unit to operate in the cooling mode;
  9. Fan button: press this button to set this unit to operate in the air supply mode;
  10. Dry button: press this button to set this unit to operate in the dry mode; 1
  11. Sleep mode: press this button to set this unit to operate in the sleep mode. (Cooling only models)
  12. Heat button: press this button to set this unit to operate in the heat mode. (Heating and cooling models)

Three. Multiple protection functions:

  1. Anti-freeze protection function:
    Upon cooling, when the compressors operates continuously for more than 10 minutes, if the pipe temperature Tp is less than or equal to 2 continuously for 20 seconds, the compressor and water spraying motor turn off, other loads operate and LED displays E4, the unit initiates the anti-frost protection function and the buttons are inactive (except the OFF button). Once the pipe temperature rises to exceed or equal 8, the protection is relieved, the original status is restored and the unit meets the requirements for 3-minute delay protection of the compressor.

  2. Full water protection function:
    When the water in the water tray exceeds the alarm level, the unit will alarm automatically and the full water indicator illuminates. In this case, you need to drain the condensate in the unit; otherwise, the unit will shut down automatically after the buzzer gives off 5 beeps. (For more information about the drain method, refer to the “Drain”). If the unit is not shut down manually, the unit will be restored to the previous operating status automatically once the water is fully drained. Or the power may be turned on again to start the unit.

  3. Delay protection function of the compressor
    This unit offers restart protection for the compressor. Except that the compressor may start immediately when the unit is energized for the first time, there is 3-minute delay start protection after the compressor is shut down.

  4. After the compressor operates continuously for 10 minutes, if the pipe temperature sensor detects that the difference between the pipe temperature and room temperature is less than 3 for 30 minutes continuously, the unit enters fluorine-free protection, the compressor and water spraying motor turn off, the fan operates in the low speed mode and E3 is displayed.

Remote Control

  1. Power key
    Press the key to turn ON/OFF the A/C.

  2. Speed key
    Press the key to choose high/low speed.

  3. Temperature/ time adjusting key
    Press the key at cooling mode to increase/reduce the setting temperature; press it at timing mode to adjust timing ON/OFF time.

  4. Mode key
    Press the key to choose cool,fan,dry.

  5. Timer key
    Press the key at standby mode to set ON time.
    Press this key at ON mode to set OFF time.

  6. Sleep Key
    Press the key to choose sleep mode.

  7. ºC/ ºF
    Press the key to switch ¥ and .

Water Drainage

1. Manual drain: (as shown in Figure 12)
1). Once the unit shuts down upon full water, turn off the power of the unit and then unplug the power plug.
Note: move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit.
2). Put the vessel that holds water below the water outlet at the back of the unit.
3). Screw off the drain cap, unplug the water plug and water will flow into the vessel that holds water automatically.
Note:
1. Protect the drain cap and water plug properly.
2. Tilt the unit slightly backward when draining.
3. If the vessel that holds water can not hold all water in the unit, before the vessel that holds water is full of water, block the water outlet with the water plug as soon as possible to prevent the water from flowing onto the ground or carpet.
4). Once the water is fully drained, insert the water plug and screw on the water cap tightly.
Note: 1. Turn on the unit only after the water plug and drain cap are installed properly; otherwise, the condensate of the unit will flow onto the ground or carpet.

2. Continuous drain:
1). Screw off the water cap in the direction shown by the arrow and unplug the water plug; (Figure 13)
2). Insert the OD 13mm PVC drain hose 8mm-10mm into the water outlet; (Figure 14) 3). Connect the drain hose to the WC or outdoor.

Note:

  1. The drain hose must be installed when there is not water in the baseplate;
  2. When operating in the cooling mode, to ensure the water for radiation of the condenser of the unit and enhance the cooling effects of the unit, it is recommended that continuous drain not be set as far as possible when this unit is in use;
  3. When operating in the heating mode, adopt continuous drain; otherwise, the unit may shut down due to full water;
  4. Put the drain hose in an inaccessible place at a height not above the water outlet and keep the drain hose free from flexure;
  5. When continuous drain is adopted, keep the drain cap and water plug properly.

Maintenance and Servicing

Prior to maintenance and servicing of the unit, turn off the power and unplug the plug.

  1. Surface cleaning
    Clean the surface of the unit with wet soft cloth. Do not use chemical solvents such as alcohol and gasoline; otherwise, the surface of the air- conditioner may be damaged and even the whole unit may be damaged.

  2. Cleaning of the filter frame and filter mesh
    Clean the filter mesh once every two weeks. If the filter frame and filter mesh are clogged with dust, the function of the air-conditioner may decrease
    2.1 Cleaning of the filter frame and filter mesh
    1). Grip the gripping position of the evaporator filter frame and the condenser filter frame and take out the filter frame gently in the direction shown by the arrow (as shown in Figure 12).
    2). Grip the gripping position of the evaporator filter mesh and condenser filter mesh and take out the filter mesh gently in the direction shown by the arrow (as shown in Figure 13).
    Note: when taking out the filter frame or filter mesh, the force shall be applied evenly to avoid twisting or damage of the filter frame or filter mesh. Be sure to take out the filter frame first and then take out the filter mesh.

    3). Put the evaporator filter frame, condenser filter frame, evaporator filter mesh, and condenser filter mesh into warm water (about 40) to which neutral cleaner is added for cleaning and then dry them in the shade (as shown in Figure 14).
    Note: 1. Do not damage the mesh fabric on the filter frame and filter mesh.

    2.2 Installation of the filter frame and filter mesh
    Special note: be sure to install the filter mesh first and then install the filter frame.
    1 To install the evaporator filter mesh and condenser filter mesh, point the back end of the filter mesh toward the socket and then push the filter mesh evenly and gently into the socket.
    Note:
    1. Install the filter mesh in the reverse order of removal. The filter mesh must be installed into place; otherwise, the filter frame may not be installed into place.
    2. Install the filter mesh gently so as not to damage it.
    2). To install the evaporator filter frame and condenser filter frame, point the back end of the filter frame toward the socket and then push the filter frame evenly and gently into the socket.
    Note: 1. Install the filter frame in the reverse order of removal. Be sure to install the filter mesh first before the filter frame is installed.
    2. Install the filter frame gently so as not to damage it

  3. Cleaning of the handle position and remote control storage area
    1). Take the remote control out of the remote control storage area in the direction shown by the arrow; (as shown in Figure 15)

    2). Clean the handle position and remote control storage area of this unit with wringed wet soft cloth;
    Note: the wet soft cloth must be wringed out. Do not drip water into the unit.
    3). If the remote control needs to be put back into the remote control storage area, put it back into the storage area in the reverse direction of removal.

Handling of the Unit

1. Handling and moving of the unit
1). To handle or move the unit, hold the top of the air outlet of the front shell with one hand and the handle position at the top of the back shell with another hand, and leave the unit in the upright position. (As shown in Figure 16).
Note:

  1. Do not hold the horizontal louvre by hand.
  2. Leave the unit in the upright position when handling or moving it.
  3. To handle or move the unit, drain the water in the unit first to prevent the water in the unit from flowing onto the ground or carpet.
  4. If the remote control is in the position of the handle, take out the remote control.

End of Season Storage

  1. Screw off the drain cap, unplug the water plug and drain the water in the water tray to another vessel that holds water.
    Note: the tilt angle of the unit shall not be greater than 30 degrees.

  2. Start the unit, turn the mode to the low fan speed state of the air supply mode, keep this state for half a day and dry the interior of the unit to prevent mold.

  3. Turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, insert the plug into the universal jack at the back shell of the unit; install the water plug and drain cap.

  4. Remove the heat exhaust hose assembly and keep it properly. Note: to remove the heat exhaust hose assembly, hold the handle of the C shape buckle of the heat exhaust hose by hand, pull the C shape buckle outward evenly, rotate the C shape buckle of the heat exhaust hose clockwise once the buckle is separated from the snap position of the C shape buckle of the back shell and then take out the heat exhaust hose assembly.

  5. Pack the air-conditioner properly with soft plastic bag, put the unit in a dry place & take appropriate dust-proof measures, and keep the unit out of the reach of children.

  6. Take out the batteries of the remote control and keep it properly.
    Note: ensure that the unit is put in a dry place. All accessories of the unit shall be protected properly.

Troubleshooting

Never repair or remove the air-conditioner yourself. Disqualified repair will void the warranty card and may cause harm to the removal personnel and property. If you encounter any of the problems listed in the table below or the recommended remedy does not work, contact the professional service agency.

Problem/fault indication

| Cause|

Remedy

---|---|---
The air-conditioner does not work| No power| Connect the unit to a live socket and turn it on.
Full water indicator illuminates?| Drain the water stored in the unit.
Ambient temperature too low or too high?| It is recommended that this unit be operated at 5-35℃.
The room temperature is lower than the set temperature in the cooling mode.
The room temperature is lower than the set temperature in the heating mode.| Change the set temperature
Bad cooling or heating effects| There is direct sunlight| Draw the curtain on.
The doors and windows are open, the room is crowded or there are other heat sources in the cooling mode| Close the door and window and add new air- conditioners
Filter mesh very dirty| Clean or replace the filter mesh
Air inlet or air outlet clogged| Remove the obstruction
Large noise| Air-conditioner Surface not put on a flat| Put the air- conditioner in a flat and firm place (may reduce noise)
The compressor does not work| Initiation of overheat protection.| Wait 3 minutes until the temperature decreases and then turn on the unit
The remote control does not work| Too long a distance| Bring the remote control close to the air-conditioner and ensure that the remote control points toward the receiving head of the remote control.
The remote control does not point toward the receiving head of the remote control
The batteries have no electricity| Replace the batteries
Display E1| Pipe temperature sensor failure| Check the pipe temperature sensor and related circuits
Display E2| Room temperature sensor failure| Check the room temperature sensor and related circuits
Display E3| No refrigerant or little refrigerant| Check the refrigerant leak location, weld the leak location, create vacuum and fill with refrigerant.
Display E4| Anti-freeze protection| Restore the functions automatically once defrozen.
Full water indicator illuminates| The water in the baseplate of the unit reaches the full water level| Drain the water in the baseplate.

Appendix

Fuse parameters
Model: FSD or 50F
Voltage: 250V
Current: 3.15A
Schematic diagram of the air-conditioner

For specific technical parameters of the models, refer to the nameplate on the product (s).

Disposal: do not store waste products with other non-classified wastes. Such wastes shall be stored separately for other special purposes.

Documents / Resources

| zokop YPO2-09C Portable Air Conditioner [pdf] User Manual
YPO2-09C, Portable Air Conditioner
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>