zokop 8000Btu Window Air Conditioner User Manual

June 1, 2024
zokop

8000Btu Window Air Conditioner

“`html

Specifications:

  • Models Available: 8000Btu, 10000Btu, 12000Btu
  • Features: AUTO SPEED, AUTO MODE
  • Refrigerant: R32
  • Country of Origin: China

Product Usage Instructions:

Introduction to Refrigerants (Only for R32 Model):

The air conditioner uses Refrigerant R32 and is suitable for
different room sizes based on the capacity:

Capacity (Btu) Room Area
9K Above 4m²
12K Above 4m²
18K Above 15m²
24K Above 25m²

Installation and Safety Warnings:

  • * Read the manual before installation, use, and maintenance.
    • Do not use unauthorized methods to defrost or clean the
      unit.

    • Avoid piercing or burning the appliance.

    • Store the appliance away from open flames or heat sources.

Operating Instructions:

  1. Ensure proper installation in a standard double-hung
    window.

  2. Secure all supporting parts to firm surfaces like wood,
    masonry, or metal.

  3. Keep the lower sash clear for vertical clearance when
    opening.

Maintenance:

Contact the nearest after-sale service center for maintenance.
Only professionals should handle maintenance tasks following the
manufacturer’s guidelines.

FAQ:

Q: Can children operate the air conditioner?

A: This appliance is not intended for use by children or
individuals with reduced capabilities. Children should be
supervised at all times around the unit.

“`

Window Air Conditioner
USER MANUAL 8000Btu, 10000Btu, 12000Btu

AUTO SPEED

AUTO MODE

Thank you for purchasing this Window Air Conditioner. Before operating this unit, please read these instructions completely and keep the manual ready for further reference.
Made in China

INTRODUCTION
IMPORTANT SAFETY INSTRUCTION …………………………………………………………………1 INTRODUCTION TO REFRIGERANTS R32(Only for R32 Model)………………………………. 2 ELECTRICAL REQUIREMENTS ………………………………………………………………………..3 PACKING LIST ………………………………………………………………………………………………4 INSTALLATION&ASSEMBLY INSTRUCTIONS …………………………………………………….. 6 THROUGH-THE-WALL INSTALLATION INSTRUCTIONS………………………………………… 11 INSTALLATION & ASSEMBLY INSTRUCTIONS……………………………………………………..12 USING YOUR AIR CONDITIONER …………………………………………………………………….. 13 OPERATING YOUR AIR CONDITIONER ………………………………………………………………15 CARE AND CLEANING …………………………………………………………………………………… 16 TROUBLESHOOTING ……………………………………………………………………………………. 17

1

INTRODUCTION TO REFRIGERANTS R32(Only for R32 Model)
The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly. Compared with ordinary refrigerants, Refrigerant R32 is environmentally friendly and do not destroy the ozone sphere and that its value of greenhouse effect is also very low.

Room area requests for air conditioner with Refrigerant R32

Refrigerant R32

Capacity(Btu) 9K 12K 18K 24K

Room Area Above 4m2 Above 4m2 Above 15m2 Above 25m2

Warnings
Please read the manual before installation, using, maintenance.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
Do not pierce or burn the appliance.
The appliance shall be stored in a room without continuously operating sources (for example: open flames, an operating ignition gas appliance or an operating electric heater.)
Please contact the nearest after-sale service center when maintenance is necessary. At the time of maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.
The handling, installation, storage, servicing and disposal must comply with the provisions of gas-related national laws and regulations, and also national wiring regulation.
It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner. Be aware that refrigerants may not contain an odour.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Unit operation limits: Outdoor side 61~110 , 80%RH; indoor side 61~90 , 80%RH.
A2L

2

(6K cooling) 10A time-delay fuse or circuit breaker
(8K-12K cooling & 8K heating) 15A time-delay fuse or circuit breaker
(12K heating) 20A time-delay fuse or circuit breaker

6K/8K/10K/12K Cooling 8K Heating

12K Heating

3

3/8″ Short Screws

5

1/2″ Length Screws

4

3/4″ Long Screws

3

5/8″ Big Flat Head Bolt and Locknut

2

Sill Angel Bracket

1/2″ Small Flat Head Bolt and

Locknut

4

Chassis Lock

(Only for E-star model) Support Bracket(with R and L remark) Battery
4

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’ S MANUAL ARE THE PRESENTATION OF THE MANUFACTURE. PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY.

Window preparation
1. This air conditioner is designed to be installed In a standard double-hung window with a window width.
2. The air conditioner can be installed without the accordion panels fit in a narrow window opening.
3. The lower sash ( the lower part of the window that moves up and down) must allow for vertical clearance when open.
4. All supporting parts must be secured to firm wood, masonry, or metal.
5. The electrical outlet must be within reach of the power cord.

For 6K/8K-Cooling

Air conditioner

STOOL SILL OFFSET
INTERIOR WALL

Bottom channel
EXTERIOR WALL

23″ to 36″ 584mm to 914mm
14-1/2″ 368mm

For 10K/12K-Cooling, 8K/12K-Heating

Air conditioner

STOOL SILL OFFSET
INTERIOR WALL

Bottom channel
EXTERIOR WALL

26″ to 36″ 660mm to 914mm
16″ 406mm

Besure that, there will be a 3 tilt angle downward to the unit back side, after finish the unit installation.

How to Install NOTE:This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear muse be maintained!
Remove the air conditioner from the box and place on a hard flat surface, as floor, a bench or a table. There is a Left and Right Window Filler Panel – be sure to use the proper panel for each side. When installed the flange for securing the panel in place to the window sill will be facing into the room.
5

REMOVE FRONT PANEL AND CHASSIS 1. Pull down the front panel and remove the filter.
2. Lift the front panel upwards to remove and place to the side.

5. Remove the control panel screw and WI-FI module screw (if available) from the front panel.

3. Locate the two faceplate screws and remove. These screws will need to be re-installed prior to mounting the air conditioner.

6.Remove the screws from the cabinet.

4. After removing the screws, gently pull away the faceplate from the air conditioner cabinet.

7. Hold the cabinet while pulling on the base handle to carefully remove the unit. Do not pull or lift near the top of the unit.

Do not pull or lift this area. It may cause damage.
Pull the base handle.

6

Top Rail Assembly

Top Foam Top Rail

1. Place the cabinet on a hard flat surface.
2. Remove top rail from the top form of the packaging material as shown in FIG. A.
3. Align the hole in the top rail with those on the top of the unit as shown in FIG. B.
4. Secure the top rail to the unit with the 3/8″ screws as shown in FIG. C.

7

Accordion Panel and cabinet Assembly
1.Hold the Accordion Panel in one hand and gently pull the center to free the open end.

4.Use two or more people, place the air conditioner into the window opening so the bottom of the air conditioner frame is against the window sill. Tilt the back of the unit slightly download to allow accumulated rain water to drain out.

2.Slide the free end of the panel into the cabinet as shown. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.

Air conditioner

STOOL SILL OFFSET
INTERIOR WALL

Bottom channel
EXTERIOR WALL

5.Fasten cabinet bottom to window sill using two 1/2″ screws. Pre-drill holes if needed.

3.Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. Slide the panel all the way for both sides.

8

1.Hold each support bracket flush against the outside of the window sill. Tighten each bracket to the bottom of the cabinet as shown. Mark the brackets at top lever of the window sill and then remove.

Support bracket Bolt and Locknut

Sill angle bracket

4. Tighten all the bolts with locknuts securely.

Sign marking

1.Team lift (two people or more) the air conditioner

2.Assemble the sill angle brackets to the support brackets at the marked position with long bolt and locknut as shown. Hand tighten, but not all the way

chassis and carefully slide it into the cabinet. Let the front of the air conditioner hang out approximately 6″.

for any changes that may need to be made later during installation.

2.CAUTION: DO NOT PUSH ON THE CONTROLS OR FINNED COILS.

Sill angle bracket

1/2″ long bolt and locknut

3.Be sure the chassis is firmly seated in the back of the cabinet.

4.Insert all screws removed during window installation and fasten, then reattach the front face plate, front panel, and the air filter.

5/8″ long bolt and locknut
3.Install the support brackets (with sill angle brackets) to the bottom of the cabinet as shown.

5. If the wall is too near to effect driving the cabinet screw back, you can assemble the chassis lock at the right bottom corner of chassis with 3/8″ screw as shown, before assemble the front panel.
Chassis Lock

9

5.Extend the side accordion panels out against the window frame as shown.

7.To secure lower sash in place, attach right angle sash lock with 3/4″ screws as shown.
Sash lock

6.Drive 1/2″ locking screws through frame holes, and drive one 3/4″ screw through top rail into window sash as shown.

8.Cut foam seal and insert in the space between the upper and lower sashes as shown.

Window seal sponge

A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1/2″. Make sure the board or piece of wood is approximately 1/2″ higher than the storm window frame. This will allow the air conditioner to tilt enough for proper drainage.

SASH

1/2 MIN

16 MIN

Storm Window Frame or Obstruction

SASH

1/2 MIN

16 MIN 1/2 MIN

Storm Window Frame or Obstruction
10

THROUGH-THE-WALL INSTALLATION INSTRUCTIONS – OPTIONAL

The case may be installed through-the-walll as optional. Read completely, then follow step-by-step. NOTE: Obtain all materials locally for mounting the air conditioner through-the-wall.

NOTE: The allowed maximum wall thickness is less than 8 9/10″. Otherwise, the wall will block the air inlet of outdoor side, it will effect the normally operation of unit.

IMPORTANT
Building a wooden frame is required when install the case through-the-wall. The opening and dimension of wooden frame is required as below.

1.Build a wooden frame into the wall opening and make sure fasten securely, which is suitable to the WALL OPENING REQUIREMENT.

Frame Max. Thickness 8 9/10″( 225 mm)

Inside Frame Width

20″( 508 mm)

Inside Frame Height 15-1/5″(385 mm)

2.Remove the air conditioner from the carton box and take off the chassis as window mounting installation.
3.Place the cabinet into the wooden frame, and lock the cabinet by the top rail hole and bottom chassis hole with 1″ long wood screws as shown, from inside to outside.

Frame Thickness

Inside Frame Height

Inside Frame Width

The Maximum Wall thickness 8 9/10″(225mm)

4. Assemble the two Support Bracket with Sill Angle Bracket to the cabinet against to the wooden frame as window mounting installation instructions.

Through-the-wall installation is not appropriate, if any of the side or top louvers of case is obstructed by the wall.
All side and top louvers in the case must project on the outdoor side of the wall.
The room side of the case must project into the room far enough to maximize the balance of the unit.
The case must be installed level from side to side and with a slight tilt from front to rear. Use a level, no more than a 1/2 bubble will be correct slant to the outside.
Lintel angle is required to support bricks or blocks above opening.
Flashing is required and should extend the length of the opening to ensure no inside cavity leakage occurs.

Support bracket Bolt and Locknut
Sill angle bracket 5. Assemble the chassis into the cabinet and fasten or
lock it, as window mounting installation instructions.

11

INSTALLATION & ASSEMBLY INSTRUCTIONS Important Considerations
Before installing the appliance, you must read the manual carefully to get the safety information and notes. Unit refrigerant charge amount: refer to unit name plate marking. A leak test must be done after the installation is completed. It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant in order to ensure that the fire risk is reduced to minimum. It is necessary to operate the machine under a controlled procedure in order to ensure that any risk arising from the combustible gas or vapor during the operation is reduced to minimum.
Introduction to Refrigerants R32(Only for R32 Model)
1. Site Safety

A2L

Open Flames Prohibited

2. Operation Safety

Open Flames Prohibited

Ventilation Necessary

Mind Static Electricity Must Wear Protective Clothing and anti-static gloves
3. Installation Safety
Refrigerant Leak Detector Appropriate Installation Location

Don’t use mobile phone

The left picture is the schematic diagram of a refrigerant leak detector.
Please note that: 1. The installation site should be in a well-ventilated condition. 2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire
or welding, smoking, drying oven or any other heat source higher than 548 which easily produces open fire. 3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear
anti-static clothing and/or gloves. 4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of
the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or explosive environment. 5. If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user’s site. 6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even. 7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also prevent mechanical damage from occurring.
12

For Cooling model

1

2

AUTO SPEED

AUTO MODE

3

98 76 54

For Heating model

1

2

AUTO SPEED

HEAT

AUTO MODE

3

98 76 54

Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces air humidity. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated. Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated. Fan Mode: The conditioner works in only ventilation. Press MODE button to set the FAN mode. With pressing the FAN SPEED button the speed changes in the following sequence: Hi, Med and Lo in FAN mode. Auto Mode: In AUTO mode the unit automatically chooses the fan speed and the mode of operation (COOL,HEAT,DRY or FAN). In this mode the temperature are set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.). Heat Mode: The heating function allows the air conditioner to heat the room. Press the MODE button to activate the heating function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated.

1. Digital Display: Without timer setting, the set temperature will be displayed. Time will be displayed under the timer setting.
2. And Button: Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61 ~88 or 16 ~31 .
3. Power Button: Turn the air conditioner on and off.
4. Mode Button: Press the mode button to cycle through the various modes: Cool, Dry, Fan and Auto, or Heat.

5. Timer Button: Use these buttons on the control

panel and remote to set the Timer.

Timer Off: The timed stop is programmed by

pressing TIMER button. Set the rest time by

pressing the button

or

until the rest

time displayed is to your liking then press

the TIMER button again.

Timer On: When the unit is off, press TIMER

button at the first time, set the temperature with

pressing the button

or

. Press TIMER

button at the second time, set the rest time with

pressing the button

or

. Press TIMER

button at the third time, confirm the setting, then

the rest time to next automatical switching-on

could be read on the display of the machine.

Note: It can be set to automatically turn off or on in

0.5-24 hours. Each press of the

buttons will increase or decrease the timer. The

Timer can be set in 0.5 hours increment below 10

hours and 1 hour increment for 10 hours or above.

The SET light will turn on while setting.

To cancel the set function, press the TIMER

button again.

13

6. ECO Button: When the unit is in ECO mode, the 10.Directional Louvers: To direct the airflow, use the

light will turn on. In ECO mode, the unit will turn-off

horizontal wheel to control the horizontal direction

once the room is cooled to the user set temperature. and the air deflector to control the vertical

The unit will turn back on when the room temperat-

direction.

ure rises above the user set temperature.

Before the compressor starts, the fan motor will run

for a while, then it will stop for awhile, It will repeat

to provide a much more comfortable feeling and save energy.

air deflector horizontal wheel air deflector

7. Sleep Button: Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise or decrease based on the room temperature and the duration of sleep.
8. Fan Speed Button: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL mode and choose Hi, Med, Lo in FAN mode.
9. Filter Button: When the Filter Check light is off, it isn’t necessary to press the Filter Check button. When the Filter Check light is on, you can turn off the light by pressing the Filter Check button. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter.

14

USING YOUR REMOTE CONTROL

DISPLAY:

4

POWER:

MODE: Press the button to select the mode of operation, AUTO, COOL, DRY, FAN and HEAT Note: The HEAT mode is inactive for COOL ONLY models. Press and hold the MODE button for more than 5 seconds to delete or add the HEAT mode on remote.

” ” and ” “:

.

Press the “FAN” speed button to select the fan options. You can choose HI, MED, LO or AUTO in COOL MODE or HEAT MODE, and HI, MED, LO in FAN MODE.

15

3/8″ Short Screws

5

1/2″ Length Screws

4

3/4″ Long Screws

3

5/8″ Big Flat Head Bolt and Locknut

2

Sill Angel Bracket

1/2″ Small Flat Head Bolt and

Locknut

4

Chassis Lock

(Only for E-star model) Support Bracket(with R and L remark) Battery
4

17

18

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals