Miele PW 5105 EL AV Washer-Extractor Installation Guide
- June 5, 2024
- Miele
Table of Contents
Installation plan
Washer-extractor
PW 5105 EL AV/LP
Technical datasheet|
---|---
Washer-extractor:| PW 5105 AV/LP
Heating:| Electric (EL)
Legend:
| Abbreviations in bold type:
Connection required
---|---
| Abbreviations in circles with dashes:
Connection optional or required depending on model version
Optional extras:
UM| Miele plinth| UO 5010 (UO = open plinth)| |
---|---|---|---|---
Height| mm| 305
Width| mm| 684
Depth| mm| 787
UG 5010 box plinth| |
Height| mm| 305
Width| mm| 692
Depth| mm| 788
BS| Concrete plinth| The quality and density of concrete must comply with the
load. Con- Crete plinth must be firmly secured to the floor!| |
Recommended height| mm| 300
Minimum height| mm| 70
Recommended width| mm| ≥700
Recommended depth| mm| ≥800
Machine connections:
1. Standard voltage (as supplied) | V | 1N AC 230 |
---|---|---|
Frequency | Hz | 50 |
Rated load | kW | 5.5 |
Fuse rating | A | 1 × 25 |
Supply lead cross-section | mm² | 3 × 2.5 |
Length of supply lead | mm | 2000 |
Supply lead without plug (supplied) |
Electrical connections must comply with national regulations.
Connection using multi-pole wall sockets in compliance with IEC/EN 60309 and IEC/EN 60947 is recommended in order to simplify electrical tests. If machines are hard-wired, a multi-pole mains switch must be provided on-site. Switches with a contact gap of more than 3 mm can be used. These include switches, fuses, and contactors (IEC/EN 60947). A wall socket or mains isolator must be easily accessible after installation.
Reinstallation of the supply point, changes to the equipment, or checks on the protective conductor, including determination of correct fuse rating, should only be performed by a properly trained electrician.
Machine data
| Unit width| mm| 700
---|---|---|---
Machine depth| mm| 827
Unit height| mm| 1020
Casing width| mm| 792
Casing depth| mm| 790
Minimum width of delivery access to the installation site| mm| 720
Minimum rear wall gap (measured to front of the machine)| mm| 1200
Wall gap (to the front of the machine)
The minimum gap ensures sufficient space for maintenance and servicing.| mm|
1000
Net weight| kg| 148
Dynamic floor load, max.| N| 2750
Static floor load, max.| N| 1960
Dynamic load, max.| N| 790
Drum frequency, max.| Hz| 18
Average heat dissipation(dependent on ambient room temperature and program
selected)| W| not yet available
Sound pressure (re 20 MPA),workplace-related (at a distance of 1 m and height
of 1.6 m)| dB (A)| <70
Installation should only be carried out by authorized fitters in accordance
with valid regulations! Observe installation instructions when installing the
machine! All rights reserved! Measurements in mm.
Technisches Datenblatt/Technical datasheet: PW 5105 EL AV/LP
Datum/Date: 3517
| Installation plan Waschmaschine/Washer PW 5105 EL AV/LP|
Date| 01.12.2010
---|---|---|---
Page| 6
Name| DEBORD
Read User Manual Online (PDF format)