SUPERVAC V16-BD Super Vac Ventilation Fans User Guide
- June 5, 2024
- SUPERVAC
Table of Contents
- Breakage or Damage During Shipment
- General Description and Specifications
- Product Safety Precautions
- Before Operating Ventilator
- Airflow VS Setback
- Operation
- Charging the Battery Packs
- Charger Operation:
- Maintenance and Repair
- Warranty
- Contact Information
- Best Practices for Battery Life
- Parts List
- Exploded View
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
READ THIS FIRST
VENTILATOR USER GUIDE
MODEL V16-BW
USER GUIDE
This manual covers the description, cautions, operation, and maintenance of
the Super Vac V16-BL.
Please take the time to read this manual before operating the ventilator.
Save this guide for future reference.
Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces. Then write us and we will send you the original bill of lading. Get a claim blank from the express or truck company. Fill the claim form out. Attach the claim blank to the original bill of lading together with a copy of our invoice. Attach a memo on which you show the value of the damaged goods. Mail or hand these papers to your local transportation agent. They will process your claim with reasonable promptness.
Please note, we cannot and will not enter claims for damages. If we filed a claim here, it would be sent to your local freight agent for verification and investigation. This time can be saved by your filing the claim directly. Every consignee is on the ground floor and in contact with the local agent who inspects the damaged goods, and thus, each claim can be given individual attention.
Since our goods are packed to comply with the regulations of all railroad, truck, and express companies, we cannot allow a deduction from any invoice because of any damage, however, be sure to file your claim promptly. Our goods are sold F.O.B. factory. We take a receipt from the transportation company certifying that the goods were delivered to them in good order, and our responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and in no case will the customer be out any expense if they follow the above instructions.
Be sure to keep all damaged goods subject to examination of the truck or express company inspector, who may call on you sometime later. These damaged goods, of course, will belong to them, and they will inform you what to do with them. If you dispose of these damaged goods, your claim may not be paid.
General Description and Specifications
Super Vac ventilators are specifically designed to provide a convenient and portable source of air. Super Vac positive pressure ventilators are tested to AMCA Standard 240-15, for use in extreme conditions.
Model if | RPM | Motor | HxWxD | Weight |
---|---|---|---|---|
V16-BL | 2400 | 1 HP Variable Speed DC | 22.75″ x 23″ x 12″ | 45 lbs |
Specifications are subject to change without notification. Refer to the model decal affixed to a ventilator to determine actual specifications.
This ventilator is designed for high-powered air movement. Each blade is dynamically balanced for high efficiency and long life.
Product Safety Precautions
- Do not use the ventilator for purposes other than it’s intended use.
- Wear eye and ear protection when operating the ventilator.
- Never operate a ventilator while fatigued.
- Do not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
- Do not wear loose clothing that could become entangled in the operating ventilator.
- Never permit anyone to operate a ventilator without proper instruction.
- Do not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact the factory for replacements.
- Do not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator, and immediately stop the motor? Be certain all mechanical motion has stopped. Do not use any power voltage other than the indicated voltage.
- Never handle energized power cords with wet hands.
- Do not place or operate the ventilator on unsteady tables, slanted surfaces, or other unstable surfaces. Never use this ventilator in any explosive environment.
- Never let extension cords or plug connections lay in the water. Locate the ventilator so that it cannot fall into water inadvertently.
- Never store or carry the battery pack so that metal objects can contact exposed battery terminals. Transporting batteries can possibly
cause fires if the battery terminals contact loose nails, screws, keys, hand tools, and the like.
Before Operating Ventilator
- This ventilator has been designed to work best with either the Milwaukee M18 REDLITHIUM High Output XC8.0Ah or HD12.0 batteries.
- This ventilator will work with any M18 battery from the Milwaukee brand.
- A complete inspection of the ventilator should be made prior to operation.
- Check all threaded fasteners for proper tightness.
- Check ventilator inlet and outlet guards for obstructions. Check and remove from the immediate surrounding area any objects that could be drawn into the ventilator intake.
- Replace damaged or missing guards before operating the ventilator.
- If using shore or mains power:
- Never use power cords with frayed, cut, or brittle insulation.
- Inspect power cord plug for proper connections to the ground fault interrupter circuit.
Airflow VS Setback
The Air Movement and Control Association International Inc. (AMCA) is a not-
for-profit international association of the world’s leading manufacturers of
air system equipment. Super Vac ventilators have been tested through this
third-party organization for over 30 years in order to provide our customers
confidence that our airflow values are correctly measured and advertised. In
order to view all AMCA Certified.
Products according to ANSI/AMCA Standard 240, follow this link.
http://www.amca.org/certified-
listed/type_company.php?pid=13&pn=Positve%20Pressure%20Ventilator.
Operation
- Use caution not to direct toxic fumes into confined spaces with the ventilator.
- Insert a Milwaukee M18 battery until it clicks. Only a single battery is necessary for operation.
- Battery removal will get easier with more remove/replace cycles. The Battery Adapter & M18 Battery interface is required by Milwaukee.
- The fan will need to be reset (turned off & on) if a new battery is inserted.
- If the fan is not reset, then the fan will not recognize the new battery and run until the previous battery is empty.
- If using shore (mains) power, use an extension cord to connect to 110 – 240V AC.
- Press and hold the power button until the blue backlight indicates powering up.
- When the fan is on, it will need to run at the minimum speed allowed by Milwaukee. (This feature is to protect the batteries from small parasitic draws)
- Turn speed control clockwise until the desired speed is reached.
- The power button will indicate the approximate power left. (It is normal for colors to flicker back and forth if 2 batteries are being used)
- Green: 50 – 100%
- Yellow: 20 – 50%
- Red: 0 – 20% (Low Battery Warning: Front Facing LED will also flash if turned on)
- To turn off, press and hold the power button until blue backlight shows.
(2) x9 Ah
(2) x12 Ah
- Runtimes are dependent on air density. temperature and battery condition. Test data showed taken at 5000ft elevation, 25% RH, 70°F with new batteries.
- Air density is primarily affected by elevation, humidity, and temperature.
- At temperatures below freezing expect battery life to decrease.
Charging the Battery Packs
Remove both DeWalt FlexVolt batteries from the fan.
Insert in DeWalt Charger. Use only DeWalt brand battery chargers.
Using DeWalt AC Fast Charger, batteries will recharge in 60-120 minutes,
depending on Amp-Hour rating.
Other DeWalt chargers, including units that work with vehicle DC power, may
take longer to fully charge the batteries.
Charger Operation:
Charge indicators
Maintenance and Repair
Maintenance should only be performed by experienced and trained personnel. If you have any questions please contact Super Vac before attempting any maintenance at www.supervac.com or 1-800-525-5224.
Be sure the ventilator is disconnected from the power source and both batteries have been removed before performing any maintenance or repair. The motor is of heavy-duty ball-bearing construction. The unit is completely sealed and requires no lubrication for the life of the motor.
The ventilator blade should be specially checked for build-up of material or dirt which may cause an imbalance. Excessive imbalance can lead to accelerated wear on motor bearings and vibration. Remove front ventilator guard. Clean blade and inside the housing with mild detergent and water. Do not use abrasives, sharp instruments or caustic solvents that may scratch or damage the fan blade.
CAUTION:
- Never store or charge the battery pack below 40°F (4°C) or above 105°F (41°C).
- Never use/charge chargers or batteries in explosive atmospheres.
- Never attempt to open the battery pack. If cracked or damaged, return it to a service center for recycling.
- Do not splash or immerse charger in water or other liquids.
Warranty
Milwaukee products carry a separate 3-year limited warranty for the compatible battery packs, chargers, and ODM battery adapter. For more information contact them at www.milwaukeetool.com or 1-800-729-3878.
Super Vacuum Manufacturing Company warrants that the equipment is free from defects in materials and workmanship when used and operated for a period of five years, excluding the motor which has a 3-year warranty. The responsibility of Super Vacuum Manufacturing The company under this limited warranty is limited to the repair and replacement of any parts which are found defective and which are returned to Super Vacuum Manufacturing Company at 3842 Redman Dr, Fort Collins, CO 80524 with transportation charges prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to SUPER VACUUM MANUFACTURING COMPANY, the original purchaser shall make a claim in writing to SUPER VACUUM MANUFACTURING COMPANY at the above address indicating the model number and type of defect. No parts or equipment will be received by SUPER VACUUM MANUFACTURING COMPANY for repair or replacement under this warranty without specific written authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of any type or cause are not covered by this warranty. All equipment manufactured by us is pre-run and tested before leaving our plant and is shipped in good working order and condition. We, therefore, extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase:
- This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernible when the equipment is returned to us for inspection.
- On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY, their warranty is to the extent that the manufacturer of such component warrants them to SUPER VACUUM MANUFACTURING COMPANY, if at all. Look in your local business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.
- If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
- Any service is other than our Authorized Service voids this warranty.
- This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTABILITY or FITNESS for a particular purpose.
Contact Information
For parts or service information, contact:
Super Vacuum Manufacturing Company, Inc.
3842 Redman Dr.
Fort Collins, CO 80524
Phone: 800-525-5224
970-297-7100
Fax: 970-297-7099
Email : info@supervac.com
Internet: www.supervac.com
Best Practices for Battery Life
-
IS IT BETTER FOR DeWALT® BATTERIES TO BE COMPLETELY DISCHARGED BEFORE CHARGING? No. Just the opposite. You should stop using a battery as soon as you feel a substantial decrease in power from the tool. Completely running down a battery may damage it. Do not tape the trigger to run down the battery.
-
WHAT IS MEMORY, AND DO DeWALT BATTERIES HAVE IT? Memory is one of many conditions which cause a loss of run-time. Memory is created from repetitive light use in the exact same application (i.e. Cordless Phones, Video Cameras, Electric Shavers, etc.) Our products rarely see light use or the exact same loads, due to variability from the user, the accessory size, as well as the material. The same variability which causes different run-times prevents our cells from developing memory. Power tools are considered high-drain applications. Memory typically develops in lower-drain rate applications, such as cordless phones, laptops, etc., because the rate at which the battery is draining is continuously the same. Power tools draw higher currents and have sporadic drain rates minimizing the opportunity for the battery to develop a memory.
-
DOES IT HURT DeWALT BATTERIES TO LEAVE THEM IN THE CHARGER? No. The DeWALT chargers have a maintenance mode that allows batteries to remain in the charger, maintaining a fully charged pack until the user is ready to work. If DeWALT NiCad batteries are stored outside of the charger, they will discharge naturally, 15-20% the first 24 hours, 7-10% the next day, and about 1% every day thereafter. NiCad batteries lose the bulk of the capacity when outside of the charger in the first 3 days. In fact, it is better for the battery to leave it in the charger to be sure it goes through Equalization and Maintenance Modes. One of the benefits of DeWALT XRP™ Lithium-Ion batteries is that they have limited self-discharge. Storing DeWALT Lithium Ion batteries outside of the charger will not result in loss of charge. Learn more about brushless tools technology.
-
WHAT CAN I DO TO IMPROVE THE RUN-TIME OF MY BATTERY? If no permanent damage has been done to your battery, you may be able to improve its run-time. The correct procedure for charging your batteries is as follows:
• Discharge the battery under normal use. Remove the battery, once you feel a loss of power from the tool. Do not tape the trigger ON.
• Let the battery sit out of the charger for a least 2 hours until the battery is at room temperature.
• Place the battery in the charger overnight to allow for a full charge on each individual cell (A minimum of 8 hours at room temperature).
• If there is no difference in run-time, there is either permanent damage or the battery has reached the end of its usable life. In either case, the battery should be replaced. -
DOES THE OUTSIDE TEMPERATURE AFFECT BATTERIES? HOW? Yes. If the batteries are too hot (105°F or higher) or too cold (below 40°F), the batteries will not take a full charge. Attempting to charge batteries outside the 40°F-105°F range can result in a permanent loss of run-time. When batteries are being charged and discharged, a chemical reaction is taking place, and if it is too hot or cold the chemical reaction is disturbed causing a loss of run-time.
-
CAN THE DeWALT CHARGER BE USED WITH A GENERATOR? Yes. All DeWALT chargers, excluding the DW9106, have been designed to handle the variations in voltage and current delivered by generators.
-
SHOULD ANY SPECIAL PRECAUTIONS BE TAKEN WHEN TRANSPORTING OR TRAVELING WITH BATTERIES? Transporting batteries can possibly cause fires if the battery terminals inadvertently come in contact with conductive materials such as keys, coins, hand tools, and the like. The U.S. Department of Transportation Hazardous Material Regulations (HMR) actually prohibits transporting batteries in commerce or on airplanes (i.e. packed in suitcases and carry-on luggage) UNLESS they are properly protected from short circuits. So anytime you transport individual batteries, make sure that the battery terminals are protected and well insulated from materials that could contact them and cause a short circuit. For more information consult the U.S. DOT website.
-
WHAT SHOULD BE DONE WITH BATTERIES ONCE THEY HAVE GONE BAD? RECYCLE THEM. DeWALT is an active participant with RBRC (Rechargeable Battery Recycling Corporation), the organization which is the international leader in the collection, transportation and recycling of NiCad cells. Old batteries should be disposed of at DeWALT Service Centers
Source: https://www.dewalt.com/dewalt-dna/featured-articles/best-practices- for-battery-life
Parts List
ITEM | QTY | PART NUMBER | DESCRIPTION |
---|---|---|---|
4 | 4 | STD HARDWARE-FHMS-127 | SCREW,FHPMS,1/4-20 UNC x 3/8 in,SS |
5 | 1 | 065-00920 | SHORE PLUG, V1X-BX |
6 | 1 | 065-00923 | POTENTIOMETER, V1X-BX |
7 | 1 | 005-10267 | KNOB, POTENTIOMETER, V1X-BX |
8 | 1 | 005-13562 | SWITCH, MOMENTARY, RGB, V1X-BX |
9 | 4 | 024-13473 | FEET RUBBER CONE SHAPE VBM-4002 |
10 | 1 | 021-10514 | CONTROLLER, HG, 18V / 36V DC MOTOR |
11 | 4 | 032-10123 | NUT, 4-40, ZINC |
12 | 4 | 4-40_Nut_Steel | |
13 | 2 | 4-40_Nut_Plastic | |
14 | 4 | 032-10122 | SCREW,FHPMS,4-40 UNC x 3/4 in,SS |
15 | 2 | 032-10121 | SCREW,FHPMS,4-40 UNC x 5/16 in,SS |
16 | 1 | 005-10269 | BUSHING, ROTATION, V1X-BX |
17 | 1 | 019-20278 | COVER, CONTROLLER BOX, V1X-BX (EURO) |
18 | 6 | 033-10874 | nutsert, TSN RIBBED, 10-24 (OPTIONAL) |
19 | 20 | 034-10963 | SCREW,PHP,10-24 UNCx0.5 |
20 | 1 | STD HARDWARE-FHMS-81 | SCREW,FHPMS,10-24 UNC x 3/8 in,SS |
21 | 1 | 019-20105 | SHROUD, WELDMENT, V16-BX |
22 | 1 | 005-10270 | WASHER, RUBBER, ROTATION, V1X-BX |
23 | 1 | 032-10789 | NUT,NYLON, 5/16-18 UNC,SS |
24 | 1 | 032-10110 | SCREW,FHPMS,5/16-18 UNC x 7/8 in,SS |
27 | 1 | 019-20400 | FRAME SPLIT BATTERY, WLDMNT V16-BX |
28 | 1 | 019-20431 | MOUNT, SIDE, PS, WLDMNT V1X-BX |
29 | 1 | 019-20430 | COVER, SIDE, POWER SUPPLY, V1X-BX |
30 | 1 | 019-20411 | PLATE, TOP LEFT, V16-BX |
31 | 1 | 019-20421 | PLATE, TOP RIGHT, V16-BX |
32 | 1 | 005-15355 | POWER SUPPLY, 750W, 24V, V1X-BX |
33 | 1 | 012-15392 | STREAMSHAPER GUARD FOR 16″ PPV FAN |
ITEM | QTY | PART NUMBER | DESCRIPTION |
--- | --- | --- | --- |
34 | 1 | 003-15330 | BLADE, PLASTIC, 30DEG, V16-BX |
35 | 1 | 021-10524 | COVER, MOTOR, V1X-BX |
36 | 1 | 021-10523 | MOTOR,1 HP TEA0,48VDC, V1X-BX |
37 | 1 | 003-15320 | BUSHING, BLADE, V1X-BX |
38 | 2 | 032-10754 | WASHER,LOCK,SPRING,REGULAR, 1/4″, SS |
39 | 2 | 032-10743 | SCREW,HH,1/4-20×3/4,SS |
40 | 4 | 032-10118 | SCREW,PPH,M3 X 0.5 x 8 mm |
41 | 1 | 065-12852 | STRAIN RELIEF,DOMED,SCR .24-.47,1/2 NPT,BLACK |
42 | 4 | 032-10119 | SCREW,HH,M5x0.8×12,SS |
43 | 4 | STD HARDWARE-28 | WASHER,LOCK,SPRING,REGULAR, #10, SS |
44 | 3 | STD HARDWARE-SHCSM71 | SCREW,SHCS,SHCS M6x1x10 |
45 | 1 | 032-10096 | SCREW,SHCS,SHCS M4x0.7×6 |
46 | 1 | 021-10523 | KEYSTOCK, MOTOR,1 HP TEA0,48VDC, V1X-BX |
47 | 2 | STD HARDWARE-FHMS-83 | SCREW,FHPMS,10-24 UNC x 1/2 in,SS |
51 | 2 | 005-15346 | BATTERY, DEWALT, 9AH, V1X-BD (MORE OPTIONS |
52 | 2 | 005-15344 | HOLDER, BATTERY, DEWALT, V1X-BD |
53 | 12 | 032-10099 | NUT,MS,HEX1,6-32UNC,SS |
54 | 8 | 032-10100 | SCREW,FHPMS,6-32 UNC x 7/8 in,SS |
55 | 4 | 005-15345 | SPACER, BATTERY, DEWALT, V1X-BD |
56 | 4 | 032-10097 | SCREW,PHP,6-32 UNCx0.5 |
57 | 4 | 005-14081 | CONNECTOR, ELEC, BATTERY, DEWALT, V1X-BD |
58 | 4 | 065-12511 | TERMINAL,RING,10,10-12 |
59 | 1 | V16-BD_Top_Right | |
60 | 1 | V16-BD_Top_Left | |
61 | 1 | 025-16019 | DECAL, SIDE, V18, V1X-BX |
62 | 1 | 025-16020 | DECAL, SHROUD, CENTER, V1X-BX |
63 | 1 | 025-16030 | DECAL, SHROUD, CHEVRON, V16-BX |
Exploded View
Revised 3-2022
V16-BD PPV User Guide
References
- AMCA certification
- DEWALT® Power Tools Official Site | Guaranteed Tough®
- Super Vac Ventilation Fans | Firefighter Ventilation & Industrial Ventilation Fans
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>