INSTRUCTION MANUAL
SERIES: SHE-B-250S
Read these instructions completely and carefully.
ATTENTIONS
Read the instruction carefully before installation,non-observance of this
instruction may cause damage to the fixture or hurt to the human body. The
installation must be carried out by a qualified electrician in accordance with
local or national codes.
Cut off the power supply before installation and maintenance!
Keep this instruction manual handy for future use.
Use only in an indoor, dry location. Clean the product with a dry cloth.
The luminaire shall be mounted out of arm’s reach. The recommended
installation height shall be at least 2,5 meters (above the ground).”
Specifications:
Model No.| Rated Input| Rated current| Delay Time|
ta| L x W x H
---|---|---|---|---|---
SHE-B-250S
|
100-240VAC
|
Max.1A
| 8s(test location), 30s,1min,3min,5min,10min|
-20-50°C
|
83x35x19mm
Types of load
Range voltage
| Incandescent lamp/
HV-halogen lamp
| Electronic ballast| Inductance ballast| Electronic transformer|
LED driver
---|---|---|---|---|---
AC 100V,50/60HZ
|
250VA
|
80VA
|
60VA
|
250VA
|
80VA
AC 240V,50/60HZ
|
250VA
|
150VA
|
100VA
|
250VA
|
150VA
Sensor
(Optional)
| Dimensions in mm(inch)| Hole opening
diameter(D)
| DayLight Detection| Light Sensitivity*
---|---|---|---|---
Sensor 1: T/SLF5.876.045
| ****
| ****
20
| Yes| 80-160 lux
Sensor 2: T/SLF5.876.019
| No| ****
No
Note: *When the sensor detects ambient light illumination >160lux, the
sensor controller shuts off the auto-detect mode.
When the sensor detects ambient light illumination <80lux, the sensor
controller starts the auto-detect mode.
How to Match 1:
Wiring Diagram:
How to Match 2:
Time delay setting
Power on, Set the delay time with a screwdriver.
The delay time can be set to 8s (“test” location), the
30s,1min.,3min.,5min.,10min.
Wiring Diagram:
Detection area
The detection range for the suspended installation:
- This part should be parallel to the floor
- Sensitivity: Highest
- Fix position: 1-2m in height
Function
- Switch on / off fast (<2S) twice, the sensor controller goes into keeping the light on mode.(The lamp load flicks twice once power on)
- Power on again, wait for about 30 seconds, lamp load turns off, and the sensor controller goes into auto-detect mode.
PIR Sensor :
Note: *When the sensor detects ambient light illumination >160lux, the sensor controller shuts off the auto-detect mode. When the sensor detects ambient light illumination <80lux, the sensor controller starts the auto- detect mode.
On/off: