TESTEC TT-SX 9001 30 MHz Active Differential Probes User Manual
- June 5, 2024
- TESTEC
Table of Contents
- TESTEC TT-SX 9001 30 MHz Active Differential Probes
- Warranty
- Compliance Information
- Terms & Symbols
- Safety Information
- Introduction
- Key Features and Description
- Setting Up and Using the Probe
- Specifications & Characteristics
- Performance Plots
- Cleaning
- China RoHS 2
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TESTEC TT-SX 9001 30 MHz Active Differential Probes
Notices
Copyright © 2021 Testec Elektronik GmbH. All rights reserved. Unauthorized
duplication of this documentation material is strictly prohibited. Users are
permitted to duplicate and distribute this documentation for internal
educational purposes only. Testec Elektronik GmbH is governed by German and
international copyright laws.
Warranty
LIMITED ONE-YEAR WARRANTY
Testec Elektronik GmbH warrants these products to be free from defective
material or workmanship for a period of 1 year from the date of original
purchase. Under this warranty, Testec is limited to repairing this product
when returned to the factory, shipping charges prepaid, within the warranty
period. Units returned to Testec Elektronik GmbH that have been subject to
abuse, misuse, damage, or accident, or have been connected, installed, or
adjusted contrary to the instructions furnished by Testec, or that have been
repaired by unauthorized persons, will not be covered by this warranty. Testec
reserves the right to discontinue models, change specifications, price, or
design of this device at any time without notice and without incurring any
obligation whatsoever. The purchaser agrees to assume all liabilities for any
damages and/or bodily injury which may result from the use or misuse of this
device by the purchaser, his employees, or agents. THIS WARRANTY IS IN LIEU OF
ALL OTHER REPRESENTATIONS OR WARRANTIES EXPRESSED OR IMPLIED AND NO AGENT OR
REPRESENTATIVE OF TESTEC ELEKTRONIK GMBH IS AUTHORIZED TO ASSUME ANY OTHER
OBLIGATION IN CONNECTION WITH THE SALE AND PURCHASE OF THIS DEVICE.
Compliance Information
EC Declaration of Conformity – EMC
Compliance was demonstrated to the following specifications listed in the
Official Journal of the European Communities: EMC Directive 2014/30/EU. EN
61326-1:2013. Electrical equipment for measurement, control and laboratory
use- EMC requirements Part 1: General requirements.
Safety
EC Declaration of Conformity – Low Voltage
Compliance was demonstrated to the following specification as listed in the
Official Journal of the European Communities: Low Voltage Directive:
2014/35/EU. EN 61010-1:2010/AMD:2016. Safety requirements for electrical
equipment for measurement, control and laboratory use – Part 031: General
requirements EN 61010-031:2015 Ed 2.0. Safety requirements for electrical
equipment for measurement, control and laboratory use – Part 031: Safety
requirements for hand- held probe assemblies for electrical measurement and
test.
U.S. and Canadian Recognized Agency Certification
The probe has been certified by TUV Rheinland Taiwan Ltd. (TUV) to conform to
the following safety standard and bears the cTUVus mark. IEC 61010-031:2015
Ed. 2.0. Safety requirements for electrical equipment for measurement, control
and laboratory use – Part 031: Safety requirements for hand- held probe
assemblies for electrical measurement and test.
Environmental
Restriction of Hazardous Substances (RoHS 2)
The product and its accessories conform to the Directive 2011/65/EU (RoHS 2)
on the restriction of the use of certain hazardous substances in electrical
and electronic equipment, inclusive of any modification and addendum to said
Directive.EN ISO 63000:2018 Technical documentation for the assessment of
electrical and electronic products with respect to the restriction of
hazardous substances. China RoHS 2 refers to the Ministry of Industry and
Information Technology Order No. 32, effective July 1, 2015. See “Hazardous
Substances Disclosure Table” on page 23.
Product End-of-Life Handling
The equipment may contain substances that could be harmful to the environment
or human health if improperly handled at the product’s end of life. To avoid
release of such substances into the environment and to reduce the use of
natural resources, we encourage you to recycle this product to an appropriate
system that will ensure that most of the materials are reused or recycled
appropriately. This product is subject to Directive 2012/19/EU of the European
Parliament and the Council of the European Union on waste electrical and
electronic equipment (WEEE), and in jurisdictions adopting that Directive, is
marked as being put on the market after August 13, 2005, and should not be
disposed of as unsorted municipal waste. Please utilize your local WEEE
collection facilities in the disposition of this product.
Terms & Symbols
Terms
A caution statement calls attention to an operating procedure or practice, which, if not followed correctly, could result in damage to or destruction of parts or the entire product.
WARNING
A warning statement calls attention to an operating procedure, or practice,
which, if not followed correctly, could result in injury or death to
personnel.
NOTE
A note statement calls attention to an operating procedure, practice, or
condition, which, should be noted before proceeding.
Symbols
- CAUTION – Statements or instructions that must be consulted in order to find out the nature of the potential hazard and any actions which must be taken.
- WARNING – HIGH VOLTAGE – the possibility of electric shock.
- Earth (ground) TERMINAL – Refer to the instructions accompanying this symbol in this manual.
- (CE) Mark is the European Union’s (EU) mandatory conformity marking for regulating the goods sold within the European Economic Area (EEA).
Safety Information
Safety Notices
These test probes have been designed and tested in accordance with accepted
industry and has been supplied is a safe condition. Before applying power,
verify that the correct safety precautions are taken (see the following
warnings). In addition, note the external markings on the instrument that are
described under “Symbols” on page 7. Throughout this manual and specifically
in this section, there are warnings, cautions, and notes that you must follow
to ensure safe operation and to maintain the probe in a safe condition..
-
WARNING
To avoid personal injury and to prevent fire or damage to the probe and the products connected to it, review and comply with the following safety Warning and Cautions. -
WARNING
Do not use your probe in a manner not specified by the manufacturer. Be aware, that if used in a manner not specified by the manufacturer, the protection provided by the probe assembly may be impaired. -
WARNING
Observe Maximum Working Voltages. To avoid injury, do not use the probes above 1000 Vrms in a CAT III environment between each input lead and earth or between the two input leads. Do not operate the TT-SX 9002 probe above 1000 Vrms mains isolated (200x attenuation) between the two input leads and above 1000 Vrms mains isolated (both 20x and 200x attenuation) between each input lead and earth. -
WARNING
Do not attempt internal service or adjustment. Do not install substitute parts or perform unauthorized modifications to the probe. Service should be carried out by Testec authorized service personnel. For any service needs, contact Testec Elektronik GmbH. -
WARNING
Avoid Exposed Circuit. To avoid injury, remove jewelry such as rings, watches, and other metallic objects. Do not touch exposed connections and components when power is present. -
WARNING
For Indoor Use Only. To avoid electric shock, injury, or fire hazard, do not operate this probe in wet or damp conditions or in an explosive atmosphere. -
WARNING
Periodically inspect your probe and probe wires to check for any damage. Do Not Operate with Visible or Suspected Failures. If you suspect there is damage, have it inspected by Testec authorized service personnel. -
WARNING
-
When it is likely that the ground protection is impaired, you must make the instrument inoperative and secure it against any unintended operation.
-
CAUTION
The probe and its cables are sensitive parts and therefore, you should be careful not to damage them though excessive bending or pulling. Avoid any mechanical shocks to the probe to guarantee accurate performance and protection.
IEC Measurement Category & Pollution Degree Definitions
Measurement Category (CAT) – classification of testing and measuring circuits
according to the types of mains circuits to which they are intended to be
connected.
- Measurement Category other than II, III, or IV: circuits that are not directly connected to the mains supply.
- Measurement Category II (CAT II): test and measure circuits connected directly to utilization points (socket outlets and similar prints) of the low-voltage mains installation.
- Measurement Category III (CAT III): test and measure circuits connected to the distribution part of a building’s low-voltage mains installation.
- Measurement Category IV (CAT IV): test and measure circuits connected at the source of the building’s low-voltage mains installation.
- Mains Isolated: is for measurements performed on circuits not directly connected to a mains supply.
Pollution – addition of foreign matter, solid, liquid, or gaseous (ionized gases) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 (P2) – only non-conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is expected.
Introduction
Overview
The Testec TT-SX 900x Series High-Voltage Differential probes allow
conventional earth-grounded oscilloscopes to be used for floating signal
measurements – up to 700 V differential or common mode voltage (TT-SX 9001)
and up to 1400 V differential or common mode voltage (TT-SX 9002). Each model
offers user selectable attenuation setting of 10x & 100x (TT-SX 9001) and 20x
& 200x (TT-SX 9002), making both probes highly versatile and usable for a
broad range of applications including power supply measurements and motor
controls. Both probes are compatible with any oscilloscope with a 1 MΩ BNC
female input and feature up to 30 MHz of bandwidth. The probes can be powered
by any oscilloscope USB port, internal batteries (4 AA batteries, not included
in the scope of delivery), or mains power adapter.
Key Features and Description
Features | Description |
---|
Attenuation Selection Button & LED Indicators
| Press the Attenuation selection button to switch between the two ranges. LED indicator will light green for attenuation selected.
Power Button
| Press to turn unit on.
Press and hold for 5 seconds to turn unit off.
Power and Overload indicator LED
| LED will turn green when the unit is on. LED will turn red when the unit is in voltage overload condition.
(Dimming of LED may indicate low batteries.)
4 mm Sheathed Banana Plug Connectors| Connects the probe to the DUT using probe hook pair provided with the probe.
Insulated BNC Male Output Connector
| The probe’s output connect is full insulated and connects directly to an oscilloscope’s BNC female input channel connector.
USB-C Input Power Port (on side of probe)
| Use USB-C Power Port to connect with USB cable when powering from mains adapter or oscilloscope’s USB port.
Supplied Accessories
Accessories | Part Number | Quantity |
---|
TT-SX GR 1
Probe Hook, Pair (black & red)
| ****
| ****
15650
| ****
1
TT-SX USB
USB Power Cord (1 m) (USB-A to USB-C)
| |
15651
| ****
1
Setting Up and Using the Probe
WARNING
Before connecting the probe for your measurement, read all the warnings in
this section and all of the warnings in the section “Safety Information” on
page 8.
Setting Up
- To use this probe, first insert the four AA batteries into the probe…
- OR, connect the USB power cord to the probe (see Figure 1 for the location of the input jack on the probe) and a USB port on the oscilloscope or to the Power Adapter plugged into a mains circuit.
Using
Connect the Insulated BNC male output connector to an input channel of the
oscilloscope.
WARNING
The Probe Must be Grounded. Before making connections to the input leads of
the probe, ensure that the output BNC connector is attached to the BNC input
channel of the oscilloscope AND the oscilloscope is properly grounded.
- Select the desired attenuation ratio, 10x or 100x (TT-SX 9001); 20x or 200x (TT-SX 9002), via the Attenuation selection button.
- Turn off the high voltage source.
- Press the probe hooks on its matching color 4 mm sheathed banana plug input lead.
- Connect the probe hooks to the circuit under test.
- After confirming that the probe operator is not touching the device under test, turn on the high-volt- age source.
- Measure the voltage under test and observe the waveform on the oscilloscope.
- Turn off high voltage source.
- Disconnect the probe inputs from the high-voltage source.
Specifications & Characteristics
The probe and oscilloscope should be warmed up for at least 20 minutes before any testing and the environmental conditions should not exceed the probe’s specified limits.
NOTE
All entries included in the following tables are characteristics unless
otherwise stated.
Electrical Specifications
Typical data, as well as nominal and measured values, are not warranted by
Testec.
| TT-SX 9001| TT-SX 9002
---|---|---
Part Number| 15601| 15602
Bandwidth (-3 dB)| 30 MHz| 30 MHz
Gain Accuracy| ±2%| ±2%
Attenuation Ratio| 10x / 100x| 20x / 200x
Rise Time| 14 ns| 14 ns
Absolute Maximum Rated Input Voltage
(each side to ground)
| 1000 V CAT III| 1000 V CAT III
Maximum Differential Input Voltage (DC + Peak AC)| ±70 V at 10x
±700 V at 100x
| ±140 V at 20x
±1400 V at 200x
Maximum Common Mode Input Voltage (DC + Peak AC)| ±70 V at 10x
±700 V at 100x
| ±140 V at 20x
±1400 V at 200x
Input Impedance| 5 MΩ, 2 pF
(each side to ground)
| 5 MΩ, 2 pF
(each side to ground)
Output Voltage| ±7 V
(driving 1 MΩ load)
| ±7 V
(driving 1 MΩ load)
| TT-SX 9001| TT-SX 9002
---|---|---
Offset (typical)| ±20 mV| ±20 mV
Noise (typical)| 0.7 mVrms| 0.7 mVrms
CMRR (typical)
| 50 Hz: -72 dB
20 kHz: -66 dB
200 kHz: -56 dB
| 50 Hz: -72 dB
20 kHz: -66 dB
200 kHz: -56 dB
Power Requirements| 4 x AA batteries or USB-C cable| 4 x AA batteries or USB-C
cable
Power Source| Input:100-240 V AC, 0.35
A Output: 5 V DC, 1 A
| Input:100-240 V AC,
0.35 A Output: 5 V DC, 1 A
Mechanical Specifications
Characteristic
Input Leads Length (each)| 55 cm ±3 cm
BNC Cable Length| 95 cm ±3 cm
Dimension (L x W x H)| 220 mm, 68 mm, 28 mm (with protective
Weight| 488 g (1.08 lb) (with batteries and protective
USB Type C Cable Length| 100 cm ±3 cm
Environmental Specifications
Characteristic
Operating Temperature| -10°C to 40°C (14°F to 104°F)
Storage Temperature| -30°C to 70°C (-22°F to 158°F)
Humidity| ≤ 80% RH @ 25°C to 35°C (77°F to 95°F)
Altitude| Operating: 2000 m
Non-operating: 15000 m
Pollution Degree| 2
Performance Plots
Figure 1 Rise Time
10x attenuation, 10%-90%
Figure 2 Rise Time
100x attenuation, 10%-90%
Figure 3 Rise Time
20x attenuation, 10%-90%
Figure 4 Rise Time
200x attenuation, 10%-90%
Figure 5 Typical Voltage Derating
Typical derating plog of the absolute maximum input voltage in common mode
Cleaning
Clean only the exterior probe body and cables. Use a soft cotton cloth light moistened with a mild solution of detergent and water. Do not allow any portion of the probe to be submerged at any time.
WARNING
Dry the probe thoroughly before attempting to make voltage measurements.
CAUTION
Do not subject the probe to solvents or solvent fumes as these can cause
deterioration of the probe body and cables.
China RoHS 2
Hazardous Substances Disclosure Table
China RoHS 2 refers to the Ministry of Industry and Information Technology
Order No. 32, effective July 1, 2015, titled Management Methods for the
Restriction of the Use of Hazardous Substances in Electrical and Electronic
Products. To comply with China RoHS 2, we determined this product’s
Environmental Protection Use Period (EPUP) to be 25 years in accordance with
the Marking for the Restricted Use of Hazardous Substances in Electronic and
Electrical Products, SJT 11364.
Part Name
| Hazardous Substance
---|---
Lead (Pb)
| Mercury (Hg)
| Cadmium (Cd)
| Hexavalent Chromium (Cr (VI))
| Polybrominated biphenyls (PBB)
| Polybrominated diphenyl ethers (PBDE)
Printed Circuit Board Assemblies| x| o| o| o| o| o
Electrical Components
| x| o| o| o| o| o
Metal Components
| x| o| o| o| o| o
Plastic Components
| o| o| o| o| o| o
This table is made per guidance of SJ/T 11364.
O: Indicates that this hazardous substance contained in all of the homogeneous materials for the part is below the limit requirement in GB/T 26572.
O:
X: Indicates that this hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in GB/T 26572.
X:
Testec Elektronik GmbH Voltastr. 8-10
63303 Dreieich / Germany Phone: +49 (0) 69- 94 333 5-0 Fax: +49 (0) 69 – 94
333 5- 55
E-Mail: info@testec.de
Web: http://www.testec.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>