PIR Adjustment
To access the adjustment screws flip down the black cover over the PIR sensor. Take great care when adjusting the sensor screws not to over tighten as they can be easily broken.
- The unit must be installed in a vertical position and fitted 1.8-2.5m above the ground.
- The PIR sensor can be adjusted, allowing the detection distance to be altered to suit the location. The detection angle is set at 110º. The duration that lamp stays on can also be altered from 5 seconds – 5 minutes. The LUX rang is 10-2000 lux. Use a small screwdriver to adjust the “TIME” and “SENS” screws. When adjusting the sensitivity (detection distance) in daylight it will be necessary to cover the sensor to simulate nighttime.
The PIR sensor has a manual override function which can be operated by taking the following steps:
- When first switched on, the PIR sensor “warms up” for approx 1 minute and then goes into AUTO mode.
- In AUTO mode, switch the power OFF and ON twice within 3 seconds, the PIR sensor will switch to MANUAL mode. In MANUAL mode, the light will remain ON permanently, without the PIR function.
- To return to AUTO mode, switch the power OFF and ON twice within 3 seconds.
- In either mode, if the power is switched OFF for more than 6 seconds, the PIR sensor will go through the ‘warm up’ process again when you turn it on next time.
Care and Safety
For your safety, always switch off the power supply before changing
lightbulbs, adjusting spotlight heads or cleaning. Do not use solvents or
abrasive cleaners as these could damage the finish. For 75430 and 75431, in
normal circumstances, stainless steel is very resistant to corrosion. It does
however require maintenance to preserve the high-quality appearance. Wash the
product with warm soapy water, removing all surface deposits. Rinse with clear
water and with a soft cloth, and wipe dry. In some cases, surface corrosion
may arise after installation. This is normally caused by tiny iron particles
left behind after the brushing process when finishing. Wash and dry as
detailed above. Then with a soft cloth soaked with protective oil, wipe all
over. However, if the product is subject to extreme environmental conditions
such as marine locations, industrial pollution and acid rain these maintenance
procedures should be carried out around four times a year. For severe
corrosion, non-abrasive cream cleaners or proprietary stainless steel cleaners
should be used to remove the corrosion. Wash and dry as detailed above. Then
with a soft cloth soaked with protective oil, wipe all over.
Do not clean the units with a pressure washer.
This LEDs are protected by the glass shade. The shaded part must be replaced immediately should it become cracked or damaged. This fitting must not be used without the glass shade in place.
Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed. Please read these instructions
carefully before commencing any work. This unit must be fitted by a competent
and qualified electrician. Install in accordance with the IEE Wiring
regulations and current Building Regulations. Check the pack and make sure you
have all the parts listed. To prevent electrocution switch off at the mains
supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge. If you are in any
doubt, please consult a qualified electrician. This light should be connected
to a circuit with a 30mA RCD fitted. If replacing an existing fitting, make a
careful note of the connections. This product is not suitable for location in
or near a marine environment. Always use the correct type and wattage bulb.
Never exceed the wattage stated. When changing a bulb, always switch off at
the mains and allow the old bulb to cool down before handling. Dispose of used
bulbs carefully and responsibly. Waste electrical products should not be
disposed of with household waste. Please recycle where facilities exist. Check
with your local authority or retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between the junction box and each light fitting. Avoid
locating any cables in positions that would cause a hazard. Position cables
and outdoor rated junction boxes (not supplied) away from areas where they may
be at risk of being cut, trapped or damaged. We recommend that you use the
H05RN-F specification cable (not supplied) which is an outdoor grade, rubber
sheathed cable. The main supply cable must have a minimum cross-section area
of 1.0mm2. Cables must be protected using a suitable conduit or plastic
trunking.
Technical data
- Supply 220-240 V~, 50 Hz
- Voltage:
- Bulb 75431 / 75435 / 75442————1 x Max. 7W LED GU10
- Type: 75430 / 75433 / 75440 / 94793—2 x Max. 7W LED GU10
- Conformity with all relevant UKCA Directive requirements.
- Conformity with all relevant EC Directive requirements.
- This is a Class 1 product and must be earthed.
- Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
- This product is rated at IP44.
Installation
Existing fittings must be completely removed before the installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires. Note that the switch is turned off before installation. Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
- Remove mounting box (A) from the product by removing dome nuts (C) and washers (D). Pull terminal block off of retaining pegs. Carefully pierce a small hole in the rubber gasket in the centre of the mounting box to allow the cable to pass through.
- Thread the cable through the hole, ensuring the drain hole is at the base of the mounting box.
- Fix the mounting box to the wall using the screws and plugs supplied (B). Ensure the wall is capable of holding the weight of the product. Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used for brick or cavity walls.
- Seal the screw fixings to maintain the IP rating of the fitting.
- Wire as detailed Wiring diagram.
- Fit the product back on to the mounting box and refit washers (D) and dome nuts (C), tighten dome nuts to secure.
- Fit the bulbs.
- Replace fuse or circuit breaker and switch on. Your light is now ready for use.
Wiring
Having correctly identified the wiring from your existing light fitting, pull
the wire through the hole and connect to the connection block inside the
product in the following way:
Check that…
- You have correctly identified the wires
- The connections are tight
- No loose strands have been left out of the connection block
Fitting/replacing bulbs (Max. 7W LED GU10)
When changing a bulb, always switch off at the mains and allow the bulb to
cool before handling. Dispose of used bulbs carefully. Do not exceed the
wattage stated or use a different shape bulb from that indicated on the
fitting.
Clockwise to engage pins. Finally, refit the lamp holder covers. Screw on
tightly to maintain IP protection. To access the bulb, unscrew the lamp holder
covers. Turn the bulb one-quarter turn anticlockwise and remove. Push the new
bulb gently into the lamp holder and twist a quarter turn