Miele PDR 918 Plan Commercial Dryer Installation Guide

June 5, 2024
Miele

Miele PDR 918 Plan Commercial Dryer

Miele PDR 918 Plan Commercial Dryer

Installation notes

Installation requirements

The tumble dryer must only be installed and commissioned by Miele Customer Service Department or an authorised dealer.

  • The tumble dryer must be installed in accordance with all relevant regulations and standards.
  • The dryer must only be operated in a room that has sufficient ventilation and which is frost-free.

Electrical connection

The electrical connection must be established by a qualified electrician.

  • The electrical connection may only be made to an electrical system provided in accordance with all appropriate local and national legislation, regulations and guidelines. Please also observe the regulations set out by your insurance provider and energy supplier, accident prevention regulations, as well as recognised codes of practice.
  • Reliable and safe operation of this tumble dryer is only ensured if it has been connected to the mains electricity supply.

The required supply voltage, power rating and fuse rating can be found on the data plate on the tumble dryer. Ensure that the supply voltage matches the voltage quoted on the data plate before establishing the electrical connection to the tumble dryer.

Connection to a supply voltage other than the one quoted on the data plate can damage the tumble dryer if the voltage is too high.

  • If more than one voltage is specified on the data plate, the tumble dryer can be converted for connection to the relevant input voltage. This conversion must be performed by the Miele Customer Service Department or by an authorised dealer. During the conversion, the wiring instructions given on the wiring diagram must be followed.

The tumble dryer can either be hard-wired or connected using a plug-and-socket connection in accordance with IEC 60309-1. For a hard-wired connection, an all-pole isolation device must be available at the installation site.

An isolation device is a switch which ensures a contact opening of more than 3 mm. These include circuit breakers, fuses and contactors (IEC/EN 60947).

If the mains supply cannot be permanently disconnected, the isolation device (including plug and socket) must be safeguarded against being switched on either unintentionally or without authorisation.

Tip: We recommend connecting the tumble dryer to the power supply via a plug and socket so that it is easier to conduct electrical safety checks (e.g. during maintenance or repair work).

  • The tumble dryer must not be connected to devices such as timers which would switch it off automatically.

If local regulations require that a residual current device (RCD) is installed, a type B re-sidual current device (sensitive to universal current) must be used.

Gas connection

The gas connection must only be carried out by a registered installation technician in ac-cordance with the applicable national regulations (see installation instructions).

The use of a gas socket is not permitted at the specified heater rating as the flow rate is too low.

The gas heating is configured at the factory in line with the gas specifications on the sticker on the rear of the appliance.

If the gas family is changed, a conversion kit must be requested from the Miele Cus-tomer Service Department (please specify the appliance type, serial number, gas family, gas group, gas connection pressure and country of installation). Follow the installation in-structions. This conversion may only be carried out by a registered specialist.

Air intake/exhaust air

The tumble dryer may only be operated when the ducting has been connected properly and the room is sufficiently ventilated.

  • Accessory parts may only be fitted when expressly approved by Miele. If other parts are used, warranty, performance and product liability claims will be invalidated.

PDR 918/518, gas heated

Dimensions

Miele PDR 918 Plan Commercial Dryer-1

Dimensions quoted in millimetres

Installation

Miele PDR 918 Plan Commercial Dryer-2

Measurements in millimeters

  • EL Electrical connection
  • G Gas connection
  • AL Exhaust duct
  • ZL Air intake
  • XCI XCI Box/Connector Box (optional)

Installation (standard/UG)

Miele PDR 918 Plan Commercial Dryer-3

Dimensions quoted in millimetres

  • B Drill hole/anchor point
  • UG Box plinth

Set up (Concrete platform)

Miele PDR 918 Plan Commercial Dryer-4

Measurements in millimeters

  • B Drill hole/anchor point
  • BS Concrete plinth

Technical data

Voltage variants/electrical data

Standard connection

  • Supply voltage                                                                  1N AC 230 V
  • Frequency                                                                        50 Hz
  • Power rating                                                                     0.6 kW
  • Fuse rating (on site)                                                          10 A
  • Minimum cross-section for connection cable                    3×1.5 mm²
  • Cable gland                                                                        M20

Gas connection

  • Nominal heat rating 18 kW

  • Machine-side connection according to ISO 7-1    ½”
    To connect the gas appliance, a corrugated metal hose line made of stainless steel according to DIN 3384 must be used. The shut-off device must be provided on-site. Due to an insufficient flow rate, the use of a gas socket is not permissible with the specified heating output.

  • Connection thread for natural gas, on-site (internal thread) ½”

  • Connection thread for liquid gas, on-site (internal thread) ½”

  • Alternative on-site connection with high-precision steel pipe according to DIN 2391/DIN2393, with smooth pipe end      DN 12

  • Min. connection length                      40 mm

Connection pressure according to DIN EN 437. Connection to gas supply must comply with national regulations.

Waste air/gas

  • Max. nominal air flow in vented mode (PDR 9xx only)              680 m³/h
  • Max. nominal air flow (PDR 5xx only)                                        680 m³/h
  • Max. permissible pressure loss                                                    290 Pa
  • Connection on machine side (ext. diameter)                               150 mm
  • Connection pipe provided on site (int. diameter)                        150 mm
  • Max. temperature                                                                        80 °C

This tumble dryer is a gas-burning machine without a flow-operated safety device with fan downstream of heat exchanger (technical design: B22). Waste gas pipework must be pressure-tight. Waste gas connections should be performed in accordance with national and local regulations and may require approval.

As relative humidity inside the vent ducting can be as high as 100%, suitable measures must be taken to prevent a backflow of condensate into the machine.

Air intake

Standard connection: air intake from installation site

Recommended free air intake cross-section into the room: 531 cm²
(equivalent to 3 times the exhaust air cross-section of a machine).
There must be sufficient air intake to the installation site to match the air outlet volume.
Alternative connection: air intake connection directly from outdoors
Connection sleeve on machine side (internal diameter)              161 mm
Connection pipe provided on site (external diameter)                160 mm

Technical data

Machine data|
---|---
Machine width, total| 906 mm
Machine height, total| 1400 mm
Machine depth, total| 1035 mm
Niche width| 1250 mm
Recommended wall spacing (up to the front edge of the machine)| 1500 mm
Minimum wall spacing (up to the back edge of the lid)| 500 mm
Packaging width| 1090 mm
Packaging height| 1526 mm
Packaging depth| 1125 mm
Maximum gross volume| 1871.3 l
Maximum gross weight| 193.3 kg
Maximum net weight| 179.5 kg
Max. floor load in operation| 2026 N
Diameter of exhaust duct| 150 mm
Drum diameter| 850 mm
Diameter of drum opening| 520 mm
Drum depth| 613 mm
Drum volume| 325 l
Diameter of door opening| 520 mm
Maximum door opening angle| 180°
Emission sound pressure level| 50 dB(A) re 20 µPa
Sound power level| 61
Average heat dissipation rate into the room| 4.5 MJ/h
Permissible ambient temperature range| 2–40 °C
Fixing options|
Fixing without plinth|
Quantity| Screw size
Tensioning strips 2|
Wood screws DIN 571 (Ø × length) 2| 6×40 mm
Plugs (Ø × length) 2| 10×50 mm
Fixing the appliance in place is absolutely essential.

Fastenings for floating screed must be supplied by the customer on site.

|
Fixing to concrete plinth|
Quantity| Screw size
Tensioning strips 2|
Wood screws DIN 571 (Ø × length) 2| 6×40 mm
Plugs (Ø × length) 2| 10×50 mm
If the tumble dryer is being fixed to a concrete plinth on site, fixing in place is absolutely essential. Fastenings for floating screed must be supplied by the customer on site.|

Options/Accessories

Concrete base (on site)

  • Minimum width 900 mm
  • Recommended height 100 mm
  • Minimum height 50 mm
  • Minimum depth 1100 mm

The quality of the concrete and its strength must be assessed according to the machine load. The on-site concrete plinth must be fixed adequately to the floor.

Miele & Cie. KG
Carl-Miele-Straße 29
33332 Gütersloh
Germany
Telefon: 05241 89-0
Telefax: 05241 89-2090
Internet: www.miele.com/professional

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals