IMPORTANT INFORMATION

Please read these instructions thoroughly before use. Failure to follow instructions may result in equipment damage or failure, losses, injury or death.

DANGER
To avoid possible electric shock:

  • If the power cord has been damaged, DO NOT operate. The MagFlo Pump should be replaced.
  • Close supervision is necessary when the unit is used by or near children.

WARNING

To reduce the risk of electric shock:

  • Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit Interrupter, and never remove the ground pin from the plug.
  • Provide a “drip loop” for the power cord. A drip loop is a downward- facing loop in the power cord, falling below the level of the electric receptacle and plug, which prevents water from traveling along the cord in the direction of the receptacle.
  • ALWAYS unplug the MagFlo Pump from power source when it is not in use.
  • ALWAYS unplug the MagFlo Pump from power source before installing, removing or servicing the MagFlo Pump components.
  • If an extension cord is necessary, a cord 14 gauge up to 100 ft. must be used. A cord may overheat if the cord is rated for less amperes or watts than the unit rating.
  • DO NOT immerse the MagFlo Pump plug in water or attempt to use a wet plug.
  • The MagFlo Pump is NOT suitable for use in swimming pools, swimming ponds, or other situations where bodily contact is made with the water.

Important – This unit is equipped with a permanent magnet. The magnetic field may affect the function of pacemakers.

CAUTION

To reduce the risk of equipment damage or failure:

  • ONLY use the MagFlo Pump in fresh water applications.
  • DO NOT place MagFlo Pump near flammable or other dangerous materials or objects.
  • ALWAYS unplug the unit if there is no water running through it to prevent overheating.
  • DO NOT run the pump dry.
  • DO NOT operate during freezing conditions. Drain MagFlo Pump and store in a protected location.

IMPORTANT
The Pond Guy is not responsible for equipment damage or failure, losses, injury or death resulting from failure to follow safety precautions, or from misuse or abuse of equipment.

Package Contents MAGFLO PUMP

the Pond guy MagFlo Series MagFlo 2160 GPH
Pump With Fountain fig 2

  1. 1 – MagFlo Pump
  2. 4 – Rubber Feet
  3. 1 – Diverter Assembly
  4. 1 – Fountain Extension Tube
  5. 2 – Female Tubing Adapters
  6. 4 – Outlet Male Tubing Adapters
  7. 1 – Volcano Spray Pattern
  8. 1 – Water Bell Spray Pattern
  9. 1 – Wide Water Bell Spray Pattern Deflector Disc

The Wide Water Bell Spray Pattern Deflector Disc is an optional disc for the Water Bell Spray Pattern (H).
Utilize when a wider pattern is desired.

For Best Results

  • MagFlo Pump should be placed on a flat surface away from sludge or algae mats.
  • DO NOT run the pump dry. To prevent overheating, unplug pump if there is no water running through it.
  • Keep MagFlo Pump pre-filter free of debris.
  • DO NOT operate during freezing conditions. Drain the MagFlo Pump and store in a protected area.

Determine Installation Method

  1. The MagFlo’s versatile nature allows you to configure your pump set up in multiple ways. Select the method below that best suits your application.
    Fountain Only
    Attach diverter assembly (C) to pump outlet of MagFlo pump (A).
    Attach fountain extension tube (D) to outlet on diverter assembly (C).
    Attach desired fountain spray pattern (G or H) to fountain extension tube (D).
    Continue to Step 2.
    Fountain & Waterfall/Feature
    Complete “Fountain Only” setup above.
    Unscrew and remove the diverter cap on the diverter assembly (C).  Attach female tubing adapter (E) to side outlet of diverter assembly (C).
    Connect and secure pond tubing to tubing adapter (E) with a hose clamp (not included).
    Connect pond tubing to your waterfall or water feature.
    Continue to Step 2.
    Waterfall/Feature Only
    Attach outlet male tubing adapter (F) to pump outlet of MagFlo pump (A).
    Connect and secure pond tubing to tubing adapter (F) with a hose clamp (not included).
    Connect pond tubing to your waterfall or water feature.
    Continue to Step 2.
    Optional In-Line Setup
    You may use MagFlo pumps in-line (out of the water) to power a waterfall/feature only, but the pump must be placed below the water level. MagFlo pumps have a flooded suction intake and will not suction lift.
    Remove pump intake screen, pre-filter sponge, and impeller screen.
    Connect one outlet male tubing adapter (F) to pump intake and one to pump discharge of MagFlo Pump (A). Connect and secure your pond tubing with a hose clamp (not included).
    Connect pond tubing to your waterfall or water feature.
    Continue to Step 3.

  2. Submerge Pump
    Submerge the MagFlo pump in a flat area in your pond. For ideal water circulation, the pump should be at the opposite end of the pond from where the water will discharge. If the fountain feature will be used, be sure the spray nozzle is at least a few inches above the water’s surface.

  3. Plug in Pump
    Plug the power cord into a standard 120-volt GFCI protected outlet.

  4. Adjust Water Flow
    Adjust water flow using the diverter valve flow control located on the diverter assembly (C), if applicable for your installation.

  5. Adjust Fountain Spray
    For the water bell spray pattern (H), it may be necessary to unscrew or tighten the deflector disc on the top of the nozzle for proper flow.

WARNING

Before performing any maintenance, always unplug the MagFlo Pump from the power source.
Perform maintenance any time there is a reduction in water flow or before storing for the winter.

CLEANING THE PUMP
Tools Required:

  • Damp Cloth or Small Brush
  • Descaler such as Airmax® D-Scale™
  1. Unplug and Remove
    Unplug the pump and detach from pond tubing. Remove fountain assembly, if applicable. Move pump to a dry workspace.

  2. Remove Pre-Filter
    Pull firmly to remove the pump pre-filter from the pump motor.

  3. Wash Pre-Filter Sponge & Impeller Screen
    Remove pump pre-filter sponge and impeller screen. Wash thoroughly with water.

  4. Remove Impeller Cover & Impeller
    Remove the impeller cover by turning counter-clockwise and then pulling to separate. Grasp by white impeller and lift out of chamber.
    (Warning: Pump is magnetically driven. You may experience a magnetic pull when removing and re-installing impeller. MagFlo 2160 has a strong magnetic pull.)

  5. Clean Impeller & Fountain
    Clean impeller and impeller chamber with water. Remove and disassemble fountain connections and tubing adapters. Wash thoroughly with water. A small brush or descaler may be helpful. If using a descaler, be sure to rinse all parts with clean water before reassembly.

  6. Reassemble Pump
    Reassemble impeller, impeller cover, impeller screen, pre-filter sponge, and pump pre-filter.
    (Note: Lower the impeller carefully into the chamber, allowing the impeller to gently drop into the chamber. Too much force can damage the pump.)

TROUBLESHOOTING

Pump does not turn on

  • Check that the power cord is connected.
  • Check to see if the GFCI or main circuit breaker is tripped.
  • Check to see if GFCI is faulty.
  • Check power cord for damage.

Pump turns on and then shuts off

  • Verify pump is completely submerged for proper cooling.
  • Check for debris clogging the pump intake.
  • If using an extension cord, verify that it is of the proper rating for the pump’s electrical requirements.

Reduced water flow

  • Check for debris clogging the pump pre-filter.
  • Perform maintenance cleaning of the pump.
  • Verify that water level is sufficient and pump is completely submerged.
  • Check plumbing for clogs.

REPLACEMENT PARTS

  • MAGFLO PUMP MODEL
    MagFlo 2160

  • REPLACEMENT IMPELLER

    120947

  • REPLACEMENT FILTER SPONGE

    120955

  • REPLACEMENT FOUNTAIN KIT

    120963

TECHNICAL SPECS

  • MODEL
    MagFlo 2160

  • VOLTAGE
    120V / 60 Hz

  • WATTAGE
    226 Watts

  • CORD
    20’

  • GPH @ 3’ HEAD
    1790 GPH

  • MAX HEAD
    16.5”

  • DISCHARGE
    1”

  • INLET
    1”

  • FITTING
    ¾”, 1” & 1¼”

Note : Diverter discharge accepts 1/2” & 3/4” fittings.

PRODUCT WARRANTY
MagFlo Pumps carry a 5-year warranty. The Pond Guy will repair or replace any unit found to be defective. This limited warranty is extended exclusively to the original purchaser and begins from the date of original purchase receipt. Abuse or misuse of this product or power cord alterations void all warranty. Impeller and filter sponge are wear items and are not covered by this warranty. Please call for a RMA number prior to returning product by calling our Customer Care Department at 866-766-3435. Failure to request an RMA number may result in delay or dismissal of your warranty claim.

THANK YOU FOR CHOOSING
The Pond Guy® Inc.
We Know Ponds™
15425 Chets Way
Armada, MI 48005
866-POND-HELP (766-3435)
thepondguy.com

View other great products on-line at www.thepondguy.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals