Device Description and Intended Use
This device is intended to measure human body temperature in children and adults. It has a compact size and digital display and can be used in a professional or household environment.
Parts and Assembly
Symbol Definitions
The following symbols are associated with your thermometer.
General Warnings
A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately, could lead to patient injury, illness, or death.
WARNING : This instrument is designed for oral, rectal, or axillary use
only.
WARNING : High prolonged fever requires medical attention, especially for
young children. Please contact your physician.
WARNING : Keep out of reach of unsupervised children. Components may be
harmful if swallowed.
WARNING : Stop using the thermometer if it operates erratically or if the
display malfunctions.
WARNING : Oral readings are usually 0.5°F to 1.0°F degree lower than
rectal readings; axillary readings are generally 0.5°F to 1.0°F lower than
oral readings.
WARNING : Avoid taking temperature for 30 minutes after physical
exercise, bathing, dining, or drinking hot or cold beverages.
WARNING : Allow the thermometer to warm naturally to room temperature
before using. Performance may be affected if operated or stored outside stated
temperature and humidity ranges or if the patient’s temperature is below the
ambient (room) temperature.
WARNING : After using, clean the thermometer and place it into the case.
Clean the unit by wiping it with a dry cloth and disinfect the probe with
isopropyl (rubbing) alcohol. See cleaning instructions for additional details.
CAUTION : Keep thermometer away from direct sunlight, extreme
temperatures, or dust.
CAUTION : Do not boil, bite, bend, drop, or disassemble the thermometer.
CAUTION : Do not open the unit except to replace the battery.
CAUTION : Do not use this device close to strong electromagnetic fields,
such as mobile telephones.
CAUTION : Do not autoclave. Please note the cleaning procedures described
in this manual.
CAUTION : Dispose of batteries in accordance with locally applicable
regulations, not with domestic waste.
CAUTION : IP22: Protected against solid foreign objects of 12.5mm
diameter and greater. Protected against vertically falling water drops when
the device is tilted up to 15°.
How to Use
- Disinfect the probe with isopropyl (rubbing) alcohol before using.
- Press and release the multifunction button. The display will read confirming the unit is functioning properly. The last measured temperature will be displayed for approximately 2 seconds. Next the thermometer will read – – – °F, (or – – -C°).
- We recommend using probe covers with all digital stick thermometers. If using, place cover over tip of unit.
- Place the probe in the appropriate position for your measurement site (see Ensuring Accurate Temperature Measurement below).
- The °F or °C symbol will flash when the unit is ready to measure temperature. Please note that the “ ” indicates a low battery. See instructions for replacing battery before measuring temperature. Do not expect an accurate temperature reading if this low battery indicator is present. An “ERR” message in the window indicates your unit is not functioning properly.
- Depending on the measurement site, the unit will complete measurement in approximately 30-40 (oral), 25-35 (rectal), or 90 (axillary) seconds. The display will flash and the unit will beep signaling completion.
- Read and record the temperature and time for reference. The reading will automatically be stored in the memory.
- The unit will automatically turn off in about 8 minutes. To prolong battery life, press the multifunction button to turn off the device manually.
Switching Temperature Modes
From the OFF position, the Celsius or Fahrenheit mode can be switched by pressing and holding the multifunction button for at least 5 seconds. After 3 seconds in one scale the °F or °C will flash, indicating ready to measure.
Ensuring Accurate Temperature Measurement
We recommend using probe covers with all digital stick thermometers (Figure 1).
Oral Use: Place the probe well under the patient’s tongue (Figure 2). Keep mouth closed while thermometer is reading.
Instruct children not to bite down on the probe. The peak temperature should
be reached in as little as 30 seconds.
Opening the mouth or improper placement of the probe tip could result in a
longer time for a reading. (30 second response time achieved in water bath
test)
Rectal Use : Lubricate the probe cover with a water-soluble jelly for easier insertion; do not use petroleum jelly, as it may cause an inaccurate reading. Gently insert the tip of the probe no more than 1/2 inch into the rectum.
STOP if you meet any resistance. The sensing unit is on the very tip of
the probe and there is no need to insert the probe deep into the rectum.
Dispose of the used probe cover and wash the thermometer as recommended.
The peak temperature should be reached in approximately 25-35 seconds.
Axillary Use: Wipe armpit with a dry towel. Place the probe in the patient’s armpit (Figure 3) and keep the patient’s arm pressed firmly against the body. In order to achieve a better axillary reading, a minimum measuring time of 90 seconds or longer is recommended, depending on placement of the probe and closure of the arm against the body.
Battery Replacement
- When the symbol “ ” appears, the battery needs to be replaced.
- Remove battery compartment lid (Figure 4).
- Use a pointed object such as a toothpick to pry loose the old battery. Avoid using any sharp metal object.
- Place new 1.55V coin-type battery (LR41 or equivalent) in the chamber with the positive (+) side facing up or towards the display of the unit.
- Replace the battery compartment lid.
Cleaning and Disinfecting
Do not use corrosive detergent to clean the unit.
Clean and disinfect the thermometer before and after each use.
Cleaning Process
- Wipe probe with a cloth dipped in a disinfectant solution such as 70% isopropyl (rubbing) alcohol or soap and water.
- Rinse off disinfectant residue.
Care and Storage
- Do NOT drop or crush; this device is not shock proof.
- Do NOT dismantle or modify device other than replacing the battery.
- Do NOT store the device in an extreme environment with direct sunlight or high temperatures.
- Store the unit in the protective case while not in use.
Specifications
LIMITED WARRANTY
This thermometer is guaranteed for a period of 24 months from date of purchase. This warranty does not cover batteries, or damage resulting from improper handling or use. Specific legal rights stipulated in your state may guide this warranty. If you have a legitimate claim under this warranty, send item(s) postage paid to Service Center, Attn: Repair Dept., 6850 Southbelt Dr., Caledonia, MI 49316. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem, your return address and $2.00 to cover shipping and handling.
Service Center
6850 Southbelt Dr.
Caledonia, MI 49316
Inspected in the U.S.A.
Made in China
Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use.
Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.
Type BF applied part
Printed in China
IB p/n 93-410HOP-00 rev 6 (4/25/2020)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>