SystemQ ACC062 Zap Press To Exit Buttons User Guide
- June 5, 2024
- SystemQ
Table of Contents
Press To Exit Buttons
ACC060-063, ACC100-103, ACC150-153 –
Quick Start Guide
Press To Exit Buttons
These classic green and red buttons are made of anodized aluminum for a
quality feel and look. The ACC063 features an illuminated button so you can
see it in low light and the ACC062 is a simple, discreet “Press to Exit”
button in a modern, minimalist design.
This guide also covers the easy read “Press to Exit” buttons, great for public
areas. The faceplate models have standard screw hole centers to fit standard
UK back boxes. If you are not fitting these into a flush mount back box we
recommend purchasing one of our surface mount boxes.
User Information
- There are no user-serviceable parts, opening or attempting to repair the product will void the warranty.
- Do not install or use the device if the wires connected are damaged or have been subjected to water ingress.
- Shut off all power to the access control system before wiring this device.
- Maintain a clean and safe environment at all times.
Definition
NO (Normally Open) – This is a contact that remains open (as default)
until activated, during the “active” state the contact provides a closed
circuit and starts conducting.
NC (Normally Closed) – This is the opposite of a NO contact. The contact
will remain closed (as default) until activated, during the “active” state the
circuit breaks and stops current flow.
Setup Example
“Press to Exit” buttons are used in access control systems to provide a
momentary contact signal to the access controller to open a magnetic
lock. This example shows a “Fail-safe” scenario. When the “Press to
Exit” button is pressed the access control power supply then releases power
from the lock, and if power is lost then the lock also releases.
Wire in NO or NC depending on the access controller used and also on the
required state of the lock during a “Failsafe” or “Fail-secure” scenario.
Connections – (ACC060-062, ACC100-103, ACC150-153)
For operation with a door access control panel and lock, the “Push to Exit”
button is wired with NC or NO.
Connections – (ACC063)
For operation with a door access control panel and lock, the “Push to Exit”
button is wired with NC or NO.
The ACC063 also has a built-in blue LED which requires 12V DC (not supplied
with the product).
Troubleshooting
If the “Push to Exit” is not activating the lock then there is likely a
shorted wire, open circuit, or some other failed device in the circuit.
To identify where the fault is, each wired connection in the circuit needs to
be tested, starting from the push button progress through, including the
keypad, the access controller, power supply, and the magnetic lock.
If the fault is with the access control button then check the connection wires
for continuity and for trapped wires. Check for water ingress on the wired
connections. Check the polarity in the power connections and ensure the NO or
NC connections are connected to the proper terminals.
Specification
| ACC060/1 /2| ACC063| ACC100/1 /2/3| ACC150/1 /2/3
---|---|---|---|---
Construction| Stainless Steel| Stainless Steel| Front – Stainless Steel
/Front
Button – Plastic
| – Stainless
Steel / Box & Button – Polycarb
Terminals| NO/NC/Common| NO/NC/Common/
DC/ GND +12V
| NO/NC/Common| NO/NC/Common
Rating| 0.5-1A 12V DC| 0.5-1A 12V DC| 0.5-1A 12V DC| 0.5-1A 12V DC
LED Colour| N/A| Blue LED| N/A| N/A
IP Rating| IP65 Waterproof| IP65 Waterproof| Internal Use Only| Internal
Use Only
Dimensions| 86 x 86 x 42mm| 86 x 86 x 42mm| 86 x 86 x 30mm| 86 x 86 x
30mm
All specifications are approximate. System Q Ltd reserves the right to change product specifications or features without notice. Whilst every effort is made to ensure that these instructions are complete and accurate, System Q Ltd cannot be held responsible for any losses, no matter how they arise, from errors or omissions in these instructions, or the performance or non- performance of the equipment refered to.
This symbol indicates that equipment must not be mixed with general household waste. For treatment, recovery, and recycling please return to your local designated WEE/CG0783SS collection point as defined by your local council.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>