estelle ESSPAFCSTMA 3-In-1 Spa Facial Steamer Humidifier User Guide
- June 5, 2024
- ESTELLE
Table of Contents
User Guide 3-IN-1 SPA
FACIAL STEAMER
HUMIDIFIER
(200ML)
ESSPAFCSTMA
SAFETY & WARNINGS
Read all instructions before use. Retain this user guide for future reference.
Read the following safety advice carefully:
-
Only use with a power supply rated for 220-240V~, 50-60Hz.
-
To avoid the risk of scalding, keep your body and face approximately 25cm from the outlet of the steamer at all times.
-
Do not immerse the steamer, power cord, or plug into water.
-
Do not put essential oils into the water tank – the boiling point is different. Failure to follow this instruction may lead to an explosion or fire and will damage the steamer.
-
Do not put any cleansers or chemical substance in the water tank.
-
Before adding water, ensure the device is turned off and unplugged.
-
Do not use the power cord too close to the steamer.
-
To avoid accidents and prevent the danger of scalding, ensure to use this device only as directed within this user guide, and to use only with care.
-
There may be residual water in the device’s tank when you open the package. That is the residual water from the device testing. It will not lead to many health problems.
-
The device must not be used by:
o People during pregnancy or while menstruating, as it may cause skin problems due to hormone imbalance.
o People who have allergies, skin diseases, dermatitis, skin allergies, or severe sunburn.
o People with skin problems, like eczema or swelling.
o People who are recovering after surgery. -
Do not touch any metal parts of the power plug when the power supply is turned on.
-
Do not pull or insert the plug with wet hands, otherwise, it may cause electric shock or may lead to a short circuit.
-
Do not allow children to use this device as it may cause burns or electric shock.
-
Put this device on a flat surface while using it, do not hold it in your hand.
-
During use or within 10 minutes after use, do not tilt, shake, or move the device. Otherwise, the hot water may leak, or a lot of steam may come out from the steam outlet.
-
After using this device, let the water completely cool down, then pour out the remaining water. Ensure to hold the device while pouring out the water.
-
Ensure to clean the water droplets on the steam outlet. Otherwise, hot water might spill out when the power supply is turned on for the next use.
OVERVIEW
- Steamer head
- Steamer body
- Mode selector
- Removable water tank
- Opening for water tank
- Power cord
- Beaker
GETTING STARTED
Before First Use:
When new, this device will have some plastic smell. To reduce the smell, it is
recommended to run the device for about 5-8 minutes (or until the plastic
smell fades) prior to first use.
Use only on a flat, level surface.
- Place the device on a flat, level, and solid surfaces, such as a desk, table or bench.
- Do not hold the appliance in your hands during use.
Removing the water supply tank
- Pull up on the water tank to remove it from the device.
- Open the water supply cap by turning it.
- Fill the water tank with distilled or purified only and close the water supply cap.
- Slide the water tank back into the opening on the device.
- Wipe away any water on the surface of the water supply tank.
Note: Ensure the power is switched off when adding water.
Powering on
- Connect the plug to a power outlet.
- Rotate the Mode Selector switch to turn on the appliance and set it to your intended use (Warm Towel, Facial Steamer or Humidifier).
Refer to the following pages for each mode’s usage instructions.
OPERATION
Using as a Steamer
- Connect the plug to a power outlet.
- Rotate the Mode Selector switch to ‘Facial Steamer’.
- The LED indicator around the selector switch will turn blue. After approximately 1 minute, the steam will be released.
- Direct the steam to your face. Keep your face at least 25 cm (10”) away from the spout (refer to Figure 1).
- When using the appliance for the first time, use your hand to feel the steam temperature at a 25 cm distance before placing your face into position.
- To ensure that the steam covers your entire face, direct the steam to the top of your chin.
Note:
When done, turn the Mode Selector switch back to the ‘Off’ position.
Do not leave running, even when the water is empty.
Using as a Towel Warmer
Note:
Turn off the power before removing the head, and ensure the device is cooled
down.
- Remove the steamer head by rotating it counter-clockwise, directing the arrow on the head to the “unlocking” position (refer to Figure 2).
- When in position, lift the head to remove it.
- Take a small, 100% cotton face towel and soak it with distilled or purified water.
Wring the towel to squeeze out the excess water until it is not dripping, then neatly fold the towel and place it into the steamer body.
- Replace the steamer head, rotating back to the locking position (refer to Figure 3).
- Connect the plug to a power outlet and rotate the Mode Selector switch to ‘Warm To we l ’.
- After two minutes of use, the towel will be warm and ready to use. Turn the Mode Selector to ‘off’.
- Ensuring no steam is rising, use forceps to pick the towel up and withdraw from the device. The towel will be very hot, and we recommend shaking the towel several times before touching it.
- When you have checked that it is at a comfortable temperature, you may use it on your face.
Using as a Humidifier
- This device can be used in dressing rooms, bedrooms or other small enclosed rooms as an air humidifier.
- Fill the water tank with water and place it in the device.
- Connect the plug to a power outlet and rotate the Mode Selector switch to ‘Humidifier’.
- The full water tank will deliver hot steam for 40 minutes.
Note:
When done, turn the Mode Selector switch back to the ‘Off’ position.
Do not leave running, even when the water is empty.
Fruit sauna function
- Prepare fruit or flowers by thinly slicing/preparing to fit into the beaker.
- Remove the steamer head (following the same steps as the Towel Warmer instructions).
- Gently place the beaker inside the unit (refer to Figure 5)
- Replace the steam head (ensure it is locked into position) and set the Mode Selector to “Facial Steamer”
CLEANING & CARE
Clean inside the main unit once a week to prevent water scale deposits,
mineral build-up or bad odor while using.
We recommend you follow the below procedure for cleaning:
- Make sure the steamer is turned off and unplugged.
- Remove the water tank and the steamer head.
- Prepare a 1:1 ratio of vinegar-to-water solution (1 cup) and pour it into the towel chamber. Let it soak for about 30 minutes. Then shake the device a little and pour the solution out.
- Rinse the towel chamber with pure distilled mineral-free water.
- If any residual odor remains, you may need to repeat this a few times.
- Replace the water tank and steamer head, ensuring the steamer head is locked into position.
SPECIFICATIONS
Rated Voltage | 220-240V~ |
---|---|
Rated Power | 600W |
Rated Frequency | 50-60Hz |
Max. Water Volume | 200ML |
Working Time | 18-40min |
TROUBLESHOOTING
Problem | Possible Cause | Solution |
---|---|---|
The device fails to heat up | Mode Selector was not turned on / in the proper | |
position | Turn Mode Selector to the desired position | |
The device is not plugged in | the power cord to an electrical outlet | |
Household Circuit Breaker has tripped or blown a fuse | Reset the Circuit |
Breaker or replace the fuse
The device heats up, but fails to produce steam| Mineral build-up in the
device build-up| Follow the Cleaning & Care instructions to clean the steamer
and remove mineral
The water tank is too low or completely empty| Refill water tank (refer to
Getting Started page)
The device works loudly and the steam smells bad| Mineral build-up in the
device| Follow the Cleaning & Care instructions to clean the steamer and
remove mineral build-up
Need more information?
We hope that this user guide has given you the assistance needed for a simple
set-up.
For the most up-to-date guide for your product, as well as any additional
assistance you may require, head online to
help.kogan.com.