ROVARY RV2000P CO2 Monitor Instruction Manual

June 5, 2024
ROVARY

****

ROVARY RV2000P CO2 Monitor

ROVARY-RV2000P-CO2-Monitor-PRODUCT

Air quality

CO2 value displayed in PPM (Parts Per Million)
ROVARY-RV2000P-CO2-Monitor-FIG1

Getting started

Thank you for purchasing our RV2000P CO2 monitor! This product is used to monitor the CO2 concentration, the RH (humidity) and the temperature. It allows you to ensure the air quality indoors.

Packing list

  • Rovary CO2- Meter
  • USB cable for power supply
  • User Manual
  • Adapter

Features at a glance

  • Large Screen & Rechargeable
  • Touch button operation
  • 15° Bevelled design, easy to read NDIR sensor with long service life Audible alarm
  • Graph with variable time – zoom levels CO2/RH/Temperature monitor
  • Auto calibration and manual calibration Max/Min value display in specified time

Overview

Drawing sketch and parts list

ROVARY-RV2000P-CO2-Monitor-FIG2

| Description| | Description
---|---|---|---
| Front panel| | Good level
| Home screen| | Low level
|  Button| | USB port
|  Button| | Hole for rope
|  Button| | Hole for screws
|  Button| | On/Off Button
| Power indicator| | Label
| High level| | Hole for sensors

When you take the device out of the box for the first time, connect it to the USB cable provided.Operating instructionsROVARY-RV2000P-CO2-Monitor-
FIG3

  1.  To turn on the CO2 meter, press the pin as shown in the photo. The pin should remain pressed.
  2.  When the meter is successfully connected, the power indicator and the 3 LEDs will blink one after the other, one by one.
  3.  The main display will show a countdown from 10, the meter is ready to use. No initial setup or calibration is required.
  4.  The Rovary RV2000P meter is rechargeable and can also be used without a cable.

General operation and settings

ROVARY-RV2000P-CO2-Monitor-
FIG4

LCD display

ROVARY-RV2000P-CO2-Monitor-FIG6

**** Name **** Name
**** CO2/RH/TEMP graph Plant mode
**** Max. value of the graph Human mode
**** Minimum value of the chart Audible alarm on/off
**** RH value CO2 measurement
**** Temperature measurement °C / °F **** Time per division – indicates

the time span of the graph
****| Main menu

Trend chart display

The graph below shows the past measurements for one of the three parameters (CO2/RH/TEMP) There are 4 modes that can be toggled using key: CO2, TEMP, RH and Cycle (switches automatically through CO2/TEMP/RH).

ROVARY-RV2000P-CO2-Monitor-FIG7

Below is a table with the available zoom levels for all parameters CO2/RH/Temp and the duration of each division for the corresponding zoom levels:

Zoom Level (Time range) Time per department
1M(minute) 5sec/div
1H(hour) 5m/div
1D(day) 2h/div
1W(week) 0.5d/div

Max/Min

There are two numeric indicators in the upper right-hand corner of the display: MAX and MIN. When the zoom level is changed, the MAX and MIN value will be displayed on the graph of the selected parameter (CO2, RH and TEMP).

Main menu functions

ROVARY-RV2000P-CO2-Monitor-
FIG8

To select the function, press the when it is underlined by the flashing bar. Note that after 1 minute, if nothing is pressed, the main menu will disappear and the device will return to the normal state.

ROVARY-RV2000P-CO2-Monitor-FIG9 ROVARY-RV2000P-
CO2-Monitor-FIG10 ROVARY-RV2000P-CO2-Monitor-
FIG11 ROVARY-RV2000P-CO2-Monitor-FIG12

Switching on/off

Turn down the switch to activate the monitor, wait 3 minutes for it to warm up. Flip the switch again to turn the device off.

ROVARY-RV2000P-CO2-Monitor-FIG13

Power source

Connect the USB power supply Connect the USB cable when the device is is set to ON.

Battery

Battery indicator

  • Flat battery: red light lights up continuously (charge the device within 20 minutes to prevent damage to the battery).
  • Charging: Red light blinks.
  • Fully charged: green light is on continuously.

Battery charging

  • Connect the USB cable when the device is switched ON.
  • Charging time: 2.5 hours (Charges for an additional 30 minutes after the light switches from red to green).
  • Working time: 8-10 hours.

Specifications

Typical test conditions: Ambient temperature: 23 ± 3°C, RH=50%~70%, Altitude= 0~10 meters

Measurement Specifications
Operating temperature 32º F – 122º F (0º – 50ºC)
Storage temperature -4 F – 140º F (-20º C – 60º C)
Operation & storage RV 0-95% (non-condensing)

CO2 measurement
Measuring range| (0-5000)ppm
Display resolution| 1 ppm (0-1000); 5ppm (1000-2000); 10ppm) (>2000)

Accuracy

| (0~3000)ppm 50ppm +-5% of measurement (take maximum)
(>3000)ppm: +-7% of the measurement
Repeatability| 20ppm at 400ppm
Temp. compensation| ±0.1% of the measurement per °C
Response time| <2 min for 63% or <4.6 min for 90% of step changes
Warm-up time| <20 seconds
Measurement| Specifications
---|---
Operating temperature| 32º F – 122º F (0º – 50ºC)
Storage temperature| -4 F – 140º F (-20º C – 60º C)
Operation & storage RV| 0-95% (non-condensing)
CO2 measurement
Measuring range| (0-5000)ppm
Display resolution| 1 ppm (0-1000); 5ppm (1000-2000); 10ppm) (>2000)

Accuracy

| (0~3000)ppm 50ppm +-5% of measurement (take maximum)
(>3000)ppm: +-7% of the measurement
Repeatability| 20ppm at 400ppm
Temp. compensation| ±0.1% of the measurement per °C
Response time| <2 min for 63% or <4.6 min for 90% of step changes
Warm-up time| <20 seconds

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals