IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

  • Use this appliance only for its intended purpose as described in this Owner’s Manual.
  • This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
  • Turn the unit OFF and unplug your air conditioner before cleaning.
  • For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
  • If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
  • Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
  • Replace immediately all electric service cords that have become frayed or otherwise damaged.
  • A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

WARNING Risk Fire or Explosion. This unit contains flammable refrigerant. Additional safety precautions must be followed.

  • Do not use means to accelerate the defrosting process Do not drill holes in the unit. or to clean, other than those recommended by the
  • Maintenance, cleaning, and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants. manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
  • GE Appliances does not support any servicing of the air conditioner.
  • Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.
  • Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
  • Keep ventilation openings clear of obstruction.
  • When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing.

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING USE OF EXTENSION CORDS RISK OF FIRE. Could cause serious injury or death.

HOW TO cONNECT ELECTRICITY

  • Do not, under any circumstances, cut or remove the third Have the wall outlet and circuit checked by a qualified (ground) prong from the power cord. For personal safety, electrician to make sure the outlet is properly grounded. this appliance must be properly grounded.
  • DO NOT use an adapter plug with this appliance. Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
  • The air conditioner should always be plugged into its
  • The power ocord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility own individual electrical outlet which has a voltage rating of electric shock hazard from this appliance.
  • Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use or the requirements.
  • air conditioner and contact a qualified service technician. that matches the rating plate.
  • This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
  • See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

Controls

GE-APPLIANCE-AHEL06BB-Room-Air-
Conditioner-1

Features and appearance will vary.

This section explains how to operate this air conditioner.

IMPORTANT:
When you turn off the air conditioner, either at the control panel or with the remote control, wait at least 3 minutes before turning it back on. This prevents the compressor from overloading. This 3 minute delay also applies when switching from cool mode to fan and back.

NOTE: There is a built in 3 minute delay. You may notice the compressor might not start right away. This was designated to protect the unit.
Do not operate your air conditioner in the Cool Mode when the outside temperature is below 61° F (16° C). This inside evaporator coil will freeze up, and the air conditioner will not operate properly.
NOTE: When the air conditioner is first plugged in, the LED display will show “88” for 3 seconds. After the air conditioner is turned on for the first time, the display will show the temperature 72° F and the fan will automatically set the Quiet speed and the Mode indicator will show ENERGY SAVE.
NOTE: Each time this ENERGY STAR qualified air conditioner is turned on, it will operate in energy save mode per the EPA requirements. You can select any other mode to satisfy your needs.

MODE
  1. Press MODE until you see the indicator light come on next to the desired setting.
  2. Choose Fan, Cool, Energy Save, or Dehum.
    • Fan – Only the fan runs. Press SPEED to select High, Med or Quiet fan speed. The display shows the current room temperature. NOTE: in fan mode, the temperature cannot be set.
    • Energy Save – In this this mode the fan runs only when cooling is needed. The fan will run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the temperature in the room is above the set temperature. The compressor then turns back on.
    • Cool – Cools the room. Press SPEED to select High, Med, Quiet or Auto Cool fan speed. Press the TEMP/TIME + or – arrow button to adjust the temperature. The fan will run continuously in cool mode.
    • Dehum – Aids in removing humidity from the room. Dehum mode cannot be used to cool room.
      NOTE: In Dehum mode, when the set temperature is close to ambient temperature, the compressor may stop and the fan will run in Quiet speed only.
SPEED
  1. Press SPEED until you see the indicator light come on next to the desired setting.
  2. Choose High, Med, Quiet, or Auto Cool
    • HIGH – For maximum cooling.
    • MED – For normal cooling.
    • QUIET – For minimum cooling and noise.
    • AUTO COOL – Adjusts the fan speed automatically to provide ideal cooling based on the room temperature.
TIMER OFF

To set the air conditioner to turn off between 1 hour and 24 hours (the air conditioner must be ON to set).

  1. Press TIMER button until Timer Off indicator light illuminates. The display will show the remaining hours before the air conditioner will turn off.
  2. Press the TEMP/TIME + or – button to change the delay time from 1 hour to 24 hours.
  3. Timer Off indicator light will remain on. The display will show the remaining time to Timer Off.
TIMER ON

To set the air conditioner to turn on between 1 hour and 24 hours.

  1. Press TIMER button until Timer On indicator light illuminates. The display will show the remaining hours before the air conditioner will turn on.
  2. Press the TEMP/TIME + or – button to change the delay time from 1 hour to 24 hours.
  3. Timer On indicator light will remain on. The display will show the remaining time to Timer On.
**To clear TIMER Program:

**

NOTE: Air conditioner can be either on or off. Press TIMER until Timer indicator light turns off.

To view or change the remaining time (in hours):

TIMER OFF

  1. Press the TEMP/TIME + or – button to increase or decrease the time.
  2. The display will show the remaining time to Timer OFF.

TIMER ON –

  1. The display will show the remaining time.
  2. Press the TEMP/TIME + or – button to increase or decrease the time.
  3. The display will show the remaining time to Timer ON.

NOTE: In TIMER and SLEEP mode, temperature cannot be adjusted.

SLEEP
  1. Press the TIMER button to choose Sleep mode. The indicator light will turn on.
  2. The temperature will increase by 2° F one hour after the mode is chosen. The temperature then increases another 2° F after one hour. The unit will hold this temperature for six hours then stop.
  3. To turn off Sleep mode, press the TIMER button until the indicator light is off.
TEMP/TIME
  1. Press the TEMP/TIME + button to raise the temperature. Each time you press the TEMP/TIME + button, the temperature will go up by 1° F until it reaches 86° F (30° C).
  2. Press the TEMP/TIME – button to lower the temperature. Each time you press the TEMP/TIME – button, the temperature will go down by 1° F until it reaches 61° F (16° C).
FILTER RESET

This feature automatically notifies you that the air filter must be cleaned. The indicator light will come on after 240 hours of operation. Clean the air filter (refer to Care and Cleaning section), place it back in the front panel, and press the Filter Reset button. The light will turn off.

Using the Remote Control

Remote Control may differ in appearance from the image show.

NOTE: Please remove the back of the controller and insert two AAA batteries. Replace batteries after 6 months of use or when remote control starts to lose power.
NOTE: DO NOT mix old and new batteries.

POWER

Press the POWER button to turn on the air conditioner. When you first press the power button, the air conditioner will operate in Energy Save mode, Quiet fan speed and temperature of 72°F. You can select any other mode to satisfy your needs .

SPEED

High – Press HIGH button to choose high fan speed. Med – Press MED button to choose medium fan speed.
Quiet – Press QUIET button to choose quiet fan speed.
Auto Cool – Press AUTO button to choose auto cool fan speed.

MODE

Fan – Press the FAN button to activate fan mode. Cool – Press the COOL button to activate cool mode. Energy Save – Press the ENERGY SAVE button to activate fan mode.
Dehum – Press the DEHUM button to activate dehum mode.

TIMER

To set the air conditioner to turn off after a set amount of time between 1 hour and 24 hours (unit must be ON):

  1. Press TIMER ON/OFF button on the remote control to select the time off function.
  2. Press the TIMER + or TIMER – arrow button to change the delay time from 1 hour to 24 hours. Timer OFF indicator light on the air conditioner panel will illuminate.
  3. The buzzer beeps twice after 5 seconds, then Timer OFF countdown will initiate.

To clear TIMER Program:
NOTE: Air conditioner can be either on or off.
Press TIMER ON/OFF button until Timer indicator light turns off.

TEMP UP/TEMP DOWN
  • Press the TEMP + button to raise the temperature. Each time you press the TEMP + button, the temperature will go up 1° F until it reaches 86°F (30°C).
  • Press the TEMP – button to lower the temperature. Each time you press the TTEMP – button, the temperature will go down 1° F until it reaches 61°F (16°C).
SLEEP
  1. Press SLEEP button on the remote control to choose Sleep mode. This display will show (08) and the indicator light will turn on.
  2. The temperature will increase by 2° F one hour after the mode is chosen. The temperature then increases another 2° F after one hour. The until will hold this temperature for six hours then stop.
  3. To turn off Sleep mode, press the SLEEP button until the indicator light is off.
FAHRENHEIT/CELSIUS

Press the F/C button to choose between Fahrenheit and Celsius.

LOCK

Press the LOCK button on the remote control to disable button functionality. Press the LOCK button again to activate the remote control functionality.

LIGHT

When you press the LIGHT button, the display on the unit will turn off, but the unit is still operating normally. When you press the LIGHT button again or press any button on the remote control, the display will be illuminated again.

RESET

Press the RESET button to reset the unit to factory settings.

Air Direction

COOL MIN:
To reduce cooling capacity, point air directional louvers up.

COOL MAX:
To maximize cooling capacity, point air directional louvers down.

Changing the Air Direction
4-Way Air Flow: The air directional louvers let you control the direction of the airflow. The airflow can be directed up-down and left to right.GE-
APPLIANCE-AHEL06BB-Room-Air-Conditioner-5

Care and Cleaning

Cleaning the Air Filter
The air filter is removable for easy cleaning. A clean air filter helps remove dust, lint and particles from the air for optimal cooling operating efficiency. The Filter Reset light will turn on to notify you that the air filter must be cleaned. The light goes on after the air conditioner has been operating for 240 hours.

  1.  Turn off the air conditioner and unplug the power supply cord from the outlet.
  2. Remove the air filter by opening the front panel and removing the air filter. Some models may have a filter that slides out instead and does not require opening of the front panel.GE-APPLIANCE-AHEL06BB-Room-Air-Conditioner-6
  3. Place the air filter back in the air conditioner.
  4. Close the front panel.
  5. Plug the power supply cord into the outlet, turn on the air conditioner and press the filter reset button to turn off the indicator light.

NOTE: Do not operate the air conditioner without the filter in place.

Cleaning the Front Panel

  1. Turn off the air conditioner and unplug the power supply cord from the outlet.
  2. Clean the front panel with a soft cloth. Do not use chemical cleaners, especially spray cleaners, sharp instruments, or flammable fluids. These products can damage the surface of your air conditioner.
  3. Air-dry the front panel completely.
  4. Plug the power supply cord in the outlet and turn on the air conditioner.

Installation Instructions

Questions? Visit our Website at: GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Completion time – Approximately 1 hour
  • We recommend that two people install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
UNPACKING THE AIR CONDITIONER

WARNING

EXCESSIVE WEIGHT HAZARD – When moving or lifting the air conditioner, use two or more people. Wear gloves when handling the air conditioner to protect against possible sharp edges and metal fins.

Remove Packaging Materials

  • Remove packaging materials. Save the carton and the foam packaging for storing the unit when not in use.
    NOTE: There is NO internal packing material inside the air conditioner to remove – DO NOT open the cabinet.

  • Handle the air conditioner gently.

  • Keep the air conditioner upright and level. Do not set the air conditioner on its side, front, back or upside down.

  • The air conditioner must be standing upright for 2 hours prior to installation and operation.

ELECTRICAL REQUIREMENTS

These models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

CAUTION

  • Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
  • Do not change the plug on the power cord of this air conditioner.
  • Aluminum house wiring may present special problems—consult a qualified electrician.
  • Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TESTss button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

TOOLS YOU WILL NEEDGE-APPLIANCE-AHEL06BB-Room-Air-
Conditioner-7

Installation Instructions

GE-APPLIANCE-AHEL06BB-Room-Air-
Conditioner-8

WINDOW REQUIREMENTS
  • These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
  • The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window. See the window opening dimensions.
  • All supporting parts must be secured to firm wood, masonry or metal.
  • The electrical outlet must be within reach of the power cord.
  • Follow the dimensions in the table and illustration for your model.
STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.

WOOD PIECES
WIDTH: 2
LENGTH: Long enough to fit inside the window frame.
Attach securely with nails or screws provided by the installer.GE-APPLIANCE-
AHEL06BB-Room-Air-Conditioner-10

PREPARE THE AIR CONDITIONER

A. Install the top mounting rail with 4 Type A screwsGE-APPLIANCE-AHEL06BB-
Room-Air-Conditioner-11
B. Slide the side curtain panels into the side panel rails.
C. For model AHD06, cut and apply a weather strip to side of the curtain frame (one each side).
D. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.

INSTALL THE AIR CONDITIONER IN THE WINDOW

A. Measure the width of the window opening and mark the center line on the inside window sill.GE-APPLIANCE-AHEL06BB-Room-Air-
Conditioner-15

For model AHD06:GE-APPLIANCE-AHEL06BB-Room-Air-
Conditioner-16

Place the unit in the window. Lower the window sash to hold unit in place.

B. Set the air conditioner in the window so that is centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
Make sure that the air conditioner is level or tilting slightly to the outside.

C. Install the side bracket into the unit and into the window sill using two 1” wood screws provided. Repeat on other side.

D. Extend the curtain panels until they fill the window.
Mark the location of the holes in each corner of  side panels in place.

INSTALL WINDOW LOCKING BRACKET AND FOAM TOP WINDOW GASKET

A. To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the window locking bracket to the window side jamb with one Type B screw.

B. Cut the foam top window gasket to the window width.

C. Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.

D. For additional energy savings, on AHD06 only, measure and cut the adhesive backed foam sheets, and apply over the side curtains and frames to seal air leakage.GE-APPLIANCE-AHEL06BB-Room-Air-Conditioner-24

Troubleshooting Tips… Before you call for service

Save time and money! Review the charts on the following pages first and you may not need to call for service.GE-APPLIANCE-AHEL06BB-Room-Air-
Conditioner-26

Normal Operating Sounds

  • YOu may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and of.
  • Water will collect in the base pan duringhigh humidity or on rainy days. The water may overfiow and drip from the outdoor sideof the unit.
  • The fan may run even when the compressor does not.
  • Water droplets being thrown against the outside coils can make a pinging noise. This helps cool the condenser.GE-APPLIANCE-AHEL06BB-Room-Air-Conditioner-25
  • You can reduce this noise by removing the subbase water plug.

To ensure maximum efficiency it is recommended to check to ensure the rubber drain plug is properly inserted. This plug may be removed during operation to minimize water in the back of the unit; however, removing it will lower the efficiency of your unit.
NOTE: Do not drill hole in the base pan.

GE Appliances Air Conditioner Limited Warranty

Staple your receipt here.
Proof of the original purchase date is needed to make a warranty claim.

For The Period Of: One Year From the date of the original purchase

Will Replace:
Replacement, repair, or refund of the original retail price for any product which fails due to a defect in materials or workmanship. If the unit is exchanged, the replacement unit is warranted for the remainder of your product’s original one-year warranty period. GE Appliances will, at its sole discretion, replace the product with a product of the same or comparable functionality and quality or refund the original retail price.

  • Properly pack your unit. We recommend using the original carton and packing materials.
  • Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect.
  • Return the product to the retail location where it was purchased.
  • In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
  • Locate your original sales receipt and make a note of Please retum all requested materials (postage pre-paid) your model and serial number.

In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:

  • Call 800.GE.CARES (800.432.2737) (in the UnitedStates) to initiate the product replacement process.
  • You will be asked to provide your name, address, date of purchase, model and serial number.
  • You should receive your replacement product or refund within 7 to 10 business days after your package is received.
  • GE Appliances will arrange for a carton to be sent to your home to recover the product.

What Will Not Cover:

  • Customer instruction. This owner’s manual prosvides Replacement of house fuses or resetting of circuit information regarding operating instructions and user controls.
  • Failure due to corrosion on models not corrosion-protected.
  • Improper installation. If you have an installation problem, or if the air conditioner is of improper capacity, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance
  • Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
  • Incidental or consequential damage caused by possible defects with this air conditioner.

Consumer Support

GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support GEAppliances.com

Register Your Appliance
Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material. In the US: GEAppliances.com/register

Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day.
In the US: GEApplianceparts.com or by phone at 877.959.8688 during normal business hours. Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Contact Us
If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the details including your phone number, or write to:
In the US: General Manager, Customer Relations | GE Appliances, Appliance Park | Louisville, KY 40225 GEAppliances.com/contact

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals