Amantii SYM-50 Symmetry 50 1 4 Inch linear Built In Electric Fireplace Black Instructions
- June 5, 2024
- Amantii
Table of Contents
Amantii SYM-50 Symmetry 50 1 4 Inch linear Built In Electric Fireplace
Black
OUTDOOR INSTALLATIONS
Select electric fireplaces are suitable for outdoor areas protected from
direct water impingement. The fireplace shall not be installed in a standalone
structure, even if the following requirements are met. In addition to
maintaining the listed mantel and combustible clearances, a rain protection
overhang factor of ½ shall be constructed to the front and each side of the
installed fireplace. See the illustrations below. When installed, the
fireplace shall be installed on the exterior of a main structure/building. All
wiring connections to line power shall be by local building code requirements.
The overhang(A) must extend at least 1/2 the roof-line height. Height is measured from the base of the fireplace. For example: if the roof-line(B) is 8 feet above the base of the fireplace, the overhang(A) must be at least 4 feet.
Illustrations
Below are visual representations of the installation guidelines for an outdoor electric fireplace:
- Diagram showing the overhang (A) about the roof-line (B) with the note “least 4 feet” indicating the minimum required overhang if the roof-line is 8 feet above the base of the fireplace.
- The three-dimensional perspective of a fireplace shows the required overhang.
- Side view of a fireplace with an overhang indicating clearances.
Specifications
Requirement | Detail |
---|---|
Location | Outdoor areas protected from direct water impingement |
Structure | Fireplace not to be installed as standalone; must be part of main |
structure/building
Overhang Factor| 1/2 the height of the roof-line above the base of the
fireplace
Wiring| By local building code requirements
OUTDOOR INSTALLATIONS
Select electric fireplaces are suitable for outdoor areas protected from direct water impingement. The fireplace shall not be installed in a standalone structure, even if the following requirements are met. In addition to maintaining the listed mantel and combustible clearances, a rain protection overhang factor of½ shall be constructed to the front and each side of the installed fireplace. See the illustrations below. When installed, the fireplace shall be installed on the exterior of a main structure/building. All wiring connections to line power shall be by local building code requirements.
- The overhang(A) must extend at least 1/2 the roof-line height. Height is measured from the base of the fireplace.
- For example: if the roof-line(B) is 8 feet above the base of the fireplace, the overhang(A) must be at 4 feet
INFORMATION
FAQ
- Can the electric fireplace be installed in a standalone structure?
- No, it must be installed on the exterior of a main structure/building.
- What is the required overhang for the fireplace?
- The overhang must extend at least 1/2 the roof-line height above the base of the fireplace.
- How is the overhang measurement determined?
- It is based on the height of the roof line above the base of the fireplace. For example, if the roof line is 8 feet high, the overhang must be at least 4 feet.