OUTDOOR INSTALLATIONS
Select electric fireplaces are suitable for outdoor areas protected from direct water impingement. The fireplace shall not be installed in a standalone structure, even if the following requirements are met. In addition to maintaining the listed mantel and combustible clearances, a rain protection overhang factor of ½ shall be constructed to the front and each side of the installed fireplace. See the illustrations below. When installed, the fireplace shall be installed on the exterior of a main structure/building. All wiring connections to line power shall be by local building code requirements.

The overhang(A) must extend at least 1/2 the roof-line height. Height is measured from the base of the fireplace. For example: if the roof-line(B) is 8 feet above the base of the fireplace, the overhang(A) must be at least 4 feet.

Illustrations

Below are visual representations of the installation guidelines for an outdoor electric fireplace:

  • Diagram showing the overhang (A) about the roof-line (B) with the note “least 4 feet” indicating the minimum required overhang if the roof-line is 8 feet above the base of the fireplace.
  • The three-dimensional perspective of a fireplace shows the required overhang.
  • Side view of a fireplace with an overhang indicating clearances.

Specifications

Requirement Detail
Location Outdoor areas protected from direct water impingement
Structure Fireplace not to be installed as standalone; must be part of main

structure/building
Overhang Factor| 1/2 the height of the roof-line above the base of the fireplace
Wiring| By local building code requirements

OUTDOOR INSTALLATIONS

Select electric fireplaces are suitable for outdoor areas protected from direct water impingement. The fireplace shall not be installed in a standalone structure, even if the following requirements are met. In addition to maintaining the listed mantel and combustible clearances, a rain protection overhang factor of½ shall be constructed to the front and each side of the installed fireplace. See the illustrations below. When installed, the fireplace shall be installed on the exterior of a main structure/building. All wiring connections to line power shall be by local building code requirements.

  • The overhang(A) must extend at least 1/2 the roof-line height. Height is measured from the base of the fireplace.
  • For example: if the roof-line(B) is 8 feet above the base of the fireplace, the overhang(A) must be at 4 feet

INFORMATION

Amantii-SYM-50-Symmetry-50-1-4-Inch-linear-Built-In-Electric-Fireplace-
Black-FIG-1FAQ

  • Can the electric fireplace be installed in a standalone structure?
    • No, it must be installed on the exterior of a main structure/building.
  • What is the required overhang for the fireplace?
    • The overhang must extend at least 1/2 the roof-line height above the base of the fireplace.
  • How is the overhang measurement determined?
    • It is based on the height of the roof line above the base of the fireplace. For example, if the roof line is 8 feet high, the overhang must be at least 4 feet.