OUTDOOR INSTALLATIONS
Select electric fireplaces are suitable for outdoor areas protected from
direct water impingement. The fireplace shall not be installed in a standalone
structure, even if the following requirements are met. In addition to
maintaining the listed mantel and combustible clearances, a rain protection
overhang factor of½ shall be constructed to the front and to each side of the
installed fireplace. See illustrations below. When installed, the fireplace
shall be installed on the exterior of a main structure/building. All wiring
connections to line power shall be in accordance with local building code
requirements. The overhang(A) must extend at least 1/2 the roof-line height.
Height is measured from the base of the fireplace.
For example: if the roof-line(B) is 8″ above the base of the fireplace, the
overhang(A) must be at 4″