Kesnos wishes that our products and services can bring convenience to your work and life. We highly recommend that you keep the manual for reference if you encounter unexpected events using the unit. Please read the manual carefully to ensure the proper use of the dehumidifier. Our company’s dehumidifiers are widely used in home or work areas.
The dehumidifier Kesnos operates quickly and efficiently to reduce the room’s humidity and bring you a healthy and comfortable life.

To Access Customer Support Faster
If there is any problem with the product, please contact Kesnos Customer Service at support@kesnos.com with your purchase Order ID to help us address the problem faster.

BEFORE FIRST USE:
To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in.

KESNOS PD160A Dehumidifier for Home and Basement - figure
1

Statement
The graphics and functions provided in this manual may not be the same as the actual product. Please always refer to the actual product.
The model of the machine on the manual is for reference only.
Please operate the machine based on the actual product.
The right to interpret the relevant terms belongs to the company.

PRECAUTION FOR USE

Important
For safety purposes, you should read the instructions carefully before using the appliance for the first time. Save the instructions for future reference.
The appliance is designed for domestic use and may only be installed and operated in accordance with these instructions for use.

  • Unplug the power supply cord before cleaning or storage.

  • Do not immerse the unit in water, or place it close to water.

  • Do not put the unit close to heat-generating devices or near flammable and dangerous materials.

  • Never put your fingers or any stick-form objects into the air inlet or outlet grille.

  • Discard water collected in the tank as instructed.

  • Install drain piping in a downward direction to make sure that condensed water can be drained continuously.

  • Place and operate the unit on a stable and level floor.

  • Do not spray or splash water directly onto the unit.

  • Do not spray any pesticide or flammable liquid onto the unit.

  • Do not place any heavy objects or let children and pets sit on the unit.

  • Do not operate dehumidifiers in a small and confined space.

  • The damaged power cord must be replaced by a licensed technician.

  • Keep the clothes at least 40 cm from the air outlet to prevent water from dripping to the unit.

  • Machine power supply wiring must be conducted according to national wiring rules.

  • The power wire needs to be connected with the external grounding line.

  • The fixed wiring which is connected with the machine must be equipped with at least
    0.118inches contact opening distance of the all-pole disconnect device.

  • This product is not intended for use in the following crowd. (including children under 8 years old). The people who got physical slump, mental sensitivity, mental illness,  mental retardation and lack the knowledge on using this product unless with the supervision of a person who can guide and teach them to use the machine.

  • Fuse model specifications:3.15A.

  • This dehumidifier is designed to operate in a working environment between 41 °F (5°C) and 95°F (35°C).

  • When using the machine with the objects around need to maintain a distance of at least 7.9inch(20cm), As the picture below:

PARTS DESCRIPTION

Front

Rear

KESNOS PD160A Dehumidifier for Home and Basement - figure
4

CONTROL INTERFACE

Control panel

KESNOS PD160A Dehumidifier for Home and Basement - figure
5

Power Button
Press one time is turned on, press again is shutdown. the figures and lights will quench when the machine shutdown.

Humidity Button
Each click, 5RH% increase by degrees, can be set range: 30 RH% – 80 RH%, can be recycled set; Press 2 seconds, can adjust settings value continuous.

Lock Button
Press the button and hold for 2 seconds and the control panel will be locked.

Timer Button
Each click, 1h increase by degrees, can be set range: 1-24h, can be recycled set; Press 2 seconds, and can adjust settings value.

Speed Button
Set the high, low wind speed.

OPERATION INSTRUCTION

Setting
Humidity Setting

In the power-on state, press the “set key” can set the humidity value, each click, 5RH% increase by degrees, range of 30 RH% – 80RH%, can be cycle setting, press two seconds, can adjust setting value continuous, automatically exit once stop press button few seconds. When setting 30 RH%, is a continuous dehumidification state.
humidity digital flashes when setting.

Timing Setting
In the Power state, is timer-power-on, and in the power-on state, is timing power off.
Press the “timing” key, can set timing time, setting range: 1-24h, can be recyclable setting.set “00” to be invalid. Press 2 seconds, can adjust the settings value continuous;
When timing setting, timing lights flash The timing lights are bright, and the nixie tube display humidity when the timing is effective; effective digital display humidity, but press the “timing” button one time, can display the timing time, after 5 seconds then automatically return back display humidity, back to the current humidity value.

The Wind Speed Setting
In the power-on state, press the “SPEED” key, can select “high wind” or” low wind” , and default “high wind “speed. In the Corresponding state, “high wind” or “low wind” lights, are constant bright.

Lock setting
When the unit is turned on, press “LOCK” and hold on for 2 seconds, the control panel will be locked together with the other buttons. To unlock the control panel, press and hold the “LOCK” button again for 2 seconds.

Water Overfill Protection
When the bucket is full of water, the machine will turn off automatically.
The indicator light will flash. After you empty the water from the bucket the indicator light will off. The machine will restart to work. (machine start and stop interval 3 minutes delay).

Defrost Function
When running under lower ambient temperature, the system will automatically determine if there is frost, if have, frost will automatically defrost.
Defrost action: fan (high wind speed) work, compressor stop.
The defrost display: during defrosting, the “defrost” indicator flashes, otherwise off.

Action Description
Power on: compressor start after the fan work for a few seconds.
The shutdown: compressor stop, after a few seconds fan stop, anion stop.
(Other failure or humidity reached the required, if need shutdown, fans stop need dozens of seconds).
Have 3 minutes delay protection function, which means in the power-on state, shutdown three minutes then start again.

Display Status Description

  • Delay power-on state, “ ” light flashes; “ .” lights lit when the machine is running;
  • When the machine stops as the current humidity reaches the set humidity, it’s a wet-controlled state, “humidity” and “running” light are flashing.
  • Press the “Lighting” key, when turning on this button, the control panel light will on, use the light-up function the light will be on, otherwise off;
  • Press the “SPEED” key, high wind lamp High light when is “high wind speed”, low wind lamp low light When ” low wind speed”;
  • Timing lamp lights Timing effective, otherwise off;
  • Defrost lights” ” flashing when in the defrost state, otherwise off;
  • Water full lamp flashing when in the water full state, otherwise off.

Error & Protection Code

Number Error Code Name of the Fault Note
1 El Humidity sensor error
2 E2 Defrost temperature sensor error
3 E4 Temperature sensor error
4 E7 The bucket is full, empty the bucket

Attention
When the machine signals the alarm, it will flash or display the alarm, in case there is multiple errors on the unit, it will show the error in a turn display behavior.

  1. If the display reads “E1”, “E2”, or “E4” error codes, please turn off and unplug the unit, and check for any obstructions. Plug it in again and restart the dehumidifier.
  2. When one of the above malfunctions occurs, the buzzer will alarm for a few seconds. Press any key during the alarm to release the alarm sound.
    If the malfunction is still present, please don’t hesitate to contact Kesnos Customer Service email: support@kesnos.com for help.

Note:
Before starting the machine, please ensure that the air outlet has been opened, otherwise, the machine will overheat. Do not pull out the power cord directly to stop the machine.

Empty the Tank or Bucket
There are two ways to remove collected water.
Use the Bucket
When the water tank is already full, the Full Tank Alert indicator will light up, the dehumidifier will automatically shut down until the tank has been emptied and placed back in the unit.
Empty the Water TankKESNOS PD160A Dehumidifier for Home and Basement -
figure 6

Continuous Drainage
When you are not using water tank drainage, you can select continuous drainage. KESNOS PD160A Dehumidifier for Home and Basement - figure
7

  1. When selecting the water tank drainage, please insert the “Plug” on the continuous drain port to prevent water leakage.
  2. When select continuously drainage, please insert the”Plug” on the water tank drain port to prevent water leakage.
    NOTE
    -Make sure the connection is tight and there is no leaking.
    -Lead the water hose to the floor drain or a suitable drainage facility, the drainage facility should be lower than the drain outlet of the dehumidifier.
    -Be sure to run the water hose sloping downward to let the water flow out smoothly.
    -When the continuous drain feature is not being used, remove the drain hose from the outlet.

CLEANING AND MAINTENANCE

WARNING
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.
A- Cleaning the dehumidifier body
Please use only a soft and a bit wet textile or cloth to clean it.
B- Cleaning filter

  1. Pull out the filter.
  2. Clean the filter: Use a vacuum cleaner to gently remove the dust from the surface of the filter. If the filter is very dirty, wipe it with warm water and a mild detergent and dry it completely.
    Slowly insert the filter back into the fuselage.
    KESNOS PD160A Dehumidifier for Home and Basement - figure
8

C-Dehumidifier storage
When you want to store the dehumidifier because you don’t use it for a long time. Please pay attention to the following steps:

  1. Empty the water in the water tank.
  2. Roll up the power cord and tie it up.
  3. Clean the filter.
  4. Place the machine in a cool and dry environment.

TROUBLESHOOTING

Check the information below for troubleshooting steps that will save you time to resolve issues that may happen with the unit. The list includes the most common issues. Listed below are not the result of a defective unit, crafts, or materials in the unit. If all troubleshooting steps have been exhausted and the issue is still occurring, feel free to get in touch with  Kesnos Customer Service to get further assistance.

Problem

| Cause|

Solution

---|---|---
The dehumidifier does not work

| The power cord is unplugged.| Make sure that the unit’s plug is inserted properly into the power outlet.
Is the tank full indicator blinking? (The tank is full or in the wrong position.)| Empty the water in the water tank and then reposition the tank.
Is the room temperature above 95°F (35°C)or below 41°F (5°C).| This product does not apply to an overly hot or cold environment, the machine will automatically protect, it is a normal phenomenon.
Is the room temperature between 41°F(5°C) and 68°F(20°C)?| When running under lower ambient temperature, the machine will automatically defrost, it is a normal phenomenon. Wait until the defrost process finish, it will restart dehumidifying again.
The dehumidifier is in the defrosting process.| It is normal for the compressor ceases while defrosting process. Walt until the defrost process finish, it will restart dehumidifying again.
Does the room humidity is lower than or reached the preset humidity level?
(The room humidity has reached the preset humidity level, the dehumidifier enters Into Standby Mode and the LCD and indicators will flash.)| Please set the humidity to 5% decrease by degrees edit than the room humidity set the humidity to 30%.
There is prevent frequent start function in the machine. Does the machine stop working Just now?| Please wait for more than 3 minutes.
Room humidity is low.| The dehumidifier is designed to work in the humidity range of 30%-80%. Above or below the work humidity range, it will not work.
The dehumidifier does not dry the air as it should| The air filter is dirty.| Clean the air filter.
Is the air inlet or air outlet obstructed?| Remove the obstruction from the air inlet or outlet.
The dehumidifier size is too small for the application.|  Increase the number of dehumidifiers. Or change a higher capacity dehumidifier.
Poor air circulation.| Please leave about 7.9inch(20cm) around the product.
Did not allow enough time to remove the moisture.| Allow enough time to remove the moisture.
When first installed, allow at least 3-4 days to maintain the desired RH.
The room has not been sealed properly.| Check that all doors, windows, and other openings are securely closed.
The air filter is clogged.| Wash the filter.
Room temperature is too low, or below 41°F (5°C) (The machine will not work and or poor dehumidify efficiency in low temperature).| Please wait until the temperature rises above 5°C or higher.
Dehumidifier operates continuously| Check if the dehumidifier is in the CONTINUOUS MODE.| Don’t set the humidity too low. Typically, 40-50% are good settings to use.
---|---|---
The room humidity is too high.| Change humidity settings. Or change a higher capacity dehumidifier.
Doors and windows are open.| Ensure that all doors, windows, and other openings are closed.
Overflow of water on the floor| The hose to connector or hose connection may be loose.| Connect the hose with the drain outlet tightly.
The water bucket has not been installed properly.| Re-install the water bucket properly.
The water tank’s float has been stunk.| Move the float and let it can be swung freely.
The magnet on the float comes off.| Put the magnet in the right position.

Warning:
If the dehumidifier is still not working properly as expected and the troubleshooting steps or solutions above may not resolve the issue. Please unplug the power and shut down  the dehumidifier then contact Kesnos customer service support@kesnos.com

SAFETY NOTE

KESNOS PD160A Dehumidifier for Home and Basement - figure
9

SPECIFICATION

MODEL PD160A
POWER SOURCE 120V ~ 60Hz
RATED POWER(95°F,90%RH) 230W
RATED CURRENT(95°F,90%RH) 2.0A
MOISTURE REMOVAL(65°F,60%RH) 9.0 Pints/Day(4.25L/Day)
MOISTURE REMOVAL(80 °F,60%RH) 14 Pints/Day(6.6L/Day)
MOISTURE REMOVAL(86 °F,80%RH) 25 Pints/Day(12L/Day)
MOISTURE REMOVAL(95 °F,90%RH) 34 Pints/Day(16L/Day)
INPUT POWER(65°F,60%RH) 128W
INPUT CURRENT(65°F,60%RH) 1.2A
IEF( 65 °F,60%RH) 1.30 liters/kWh
MOTOR FLA 0.19A
MOTOR COMPRESSOR RLA:2.SA LRA:10.0A
REFRIGERANT R134a/5.llozs(145g)
MAXLMUM ALLOWABLEPRESSURE 363PSIG(2.SMPa)
HIGH PRESSURE 232PSIG(l.6MPa)
LOW PRESSURE 90PSIG(0.62MPa)
DIMENSIONS 12.28.320.9 inch
NET WEIGHT 26.SLB

WARNING:
This product can expose you to chemicals including Styrene and its compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to: www.P65Warnings.ca.gov

WARRANTY AND CONTACT US

Warranty
Kesnos offers a 12-month warranty to all of our products, newly purchased and unused, from Kesnos or through an authorized reseller, together with the original proof of purchase when a defect occurred, wholly or substantially, or as a result of faulty manufacturing, parts or workmanship during the Warranty Period. The warranty does not apply  if the damage is caused by other factors, including without limitation:
(a) Normal wear and tear;
(b) Abuse, mishandling, accident, or failure to follow operating instructions;
(c) Exposure to liquid or infiltration of foreign particles;
(d) Servicing or modification of the product other than by Kesnos.
These are our general terms for the warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms. If you experience an issue with a Kesnos product, please contact us at support@kesnos.com, we will do our best to resolve it for you.

Extend Your Warranty by 1 Year
Register your product at www.kesnos.com to extend your 1-year warranty by an additional year.

  • Please fill out all required fields and include your order ID, Date of Purchase if applicable.

Customer Support
If you have any questions or concerns about your product, please feel free to contact our expert support team. Kesnos customer service is here to help!

Kesnos Office
13211, Spring Street Baldwin Park, CA, US
Email: support@kesnos.com
Live Chat: www.kesnos.com

Support Hours
24 Hours available
*Please have your order number before contacting customer support.

For FAQ$ and more information, please
visit: www.kesnos.comKESNOS PD900AC 90L Commercial
Dehumidifier for Space up to 8 000 Sq - qr codehttps://kesnos.com/
We would love to see our product being used and how it makes your day!! Your support means the world, Please tag us if you share a snap on your social media.
www.kesnos.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals