Sony ICD-UX570 Digital Voice Recorder-User Instructions

June 5, 2024
Sony

Sony

Sony ICD-UX570 Digital Voice Recorder

Sony ICD-UX570 Digital Voice Recorder

Specifications

  • DIMENSIONS : ‎43 x 4.31 x 6.13 inches
  • WEIGHT : 1.76 ounces
  • CAPACITY (USER AVAILABLE CAPACITY 12)

4 GB (approx. 3.20 GB = 3,435,973,837 Byte)

MAXIMUM RECORDING TIME 34 (BUILT-IN MEMORY)

The maximum recording time of all the folders is as follows.

LPCM 44.1 kHz/16 bit (STEREO) 5 hours 20 minutes
MP3 192 kbps (STEREO) 39 hours 45 minutes
MP3 128 kbps (STEREO) 59 hours
MP3 48 kbps (MONO) 159 hours

*BATTERY LIFE (A BUILT-IN RECHARGEABLE LITHIUM-ION BATTERY) 5**

| |

Recording mode

|

Recording

| Recording (while monitoring)| Playback with the built-in speaker| Playback with the headphones
---|---|---|---|---
LPCM 44.1 kHz/16 bit (STEREO)| 20 hours| 12 hours| 5 hours| 34 hours
MP3 192 kbps (STEREO)| 22 hours| 13 hours| 5 hours| 47 hours
MP3 128 kbps (STEREO)| 22 hours| 13 hours| 5 hours| 47 hours
MP3 48 kbps (MONO)| 22 hours| 13 hours| 5 hours| 47 hours
Music file (MP3 128 kbps)| –| –| 5 hours| 47 hours

The battery life spans provided here are all approximate periods of time.

Recording mode

|

Recording

| Recording (while monitoring)| Playback with the built-in speaker| Playback with the headphones
---|---|---|---|---
LPCM 44.1 kHz/16 bit (STEREO)| 20 hours| 12 hours| 5 hours| 34 hours
MP3 192 kbps (STEREO)| 22 hours| 13 hours| 5 hours| 47 hours
MP3 128 kbps (STEREO)| 22 hours| 13 hours| 5 hours| 47 hours
MP3 48 kbps (MONO)| 22 hours| 13 hours| 5 hours| 47 hours
Music file (MP3 128 kbps)| –| –| 5 hours| 47 hours

TEMPERATURE/HUMIDITY

Operating temperature 41 °F – 95 °F (5°C – 35°C)
Operating humidity 25% – 75%
Storage temperature 14 °F – 113 °F (-10°C – +45°C)
Storage humidity 25% – 75%

COMPATIBLE MEMORY CARDS

  • microSDHC cards from 4 GB to 32 GB
  • microSDHC cards of 64 GB or more
  • *1 A small amount of the built-in memory is used for file management and therefore not available for user storage.
  • *2 When the built-in memory is formatted with the IC recorder.
  • *3 The maximum recordable time in this topic is provided for your reference only.
  • *4 Default settings for the recording scenes.
  • *5 Measured values acquired under our measurement conditions. These values may decrease depending on the usage conditions.
  • BRAND: Sony

Refer to the Help Guide

This is the Operating Instructions, which provides you with instructions on the basic operations of the IC recorder. The Help Guide is an online manual.
Refer to the Help Guide when you would like to know further details, operations and possible solutions when a problem occurs.
https://rd1.sony.net/help/icd/u57/h_uc/

Sony ICD-UX570 Digital Voice Recorder \(1\)

Check the supplied items

  • IC Recorder (1)
  • Operating Instructions (this sheet)
  • Warranty card (1)
  • Application Software, Sound Organizer 2 (Installer file stored in the built-in memory so that you can install it to your computer.)

Parts and Controls

Sony ICD-UX570 Digital Voice Recorder \(2\)

  1. Built-in microphones
  2. Operation indicator
  3. Display window
  4. REC/PAUSE (record/pause) button
  5. STOP button
  6. T-MARK (track mark) button
  7. BACK/ HOME button
  8. OPTION button
  9. (play/enter) button*1
  10. Control button (DPC (Digital Pitch Control), A-B (repeat A-B), (review/fast backward), (cue/fast forward))
  11. 3 EASY SEARCH(SEC) button
  12. 10 EASY SEARCH(SEC) button
  13. USB connector cover (You can find the USB connector retracted behind the cover.)
  14. Strap hole (No strap is supplied with your IC recorder.)
  15. POWER•HOLD switch*2
  16. VOL –/+*1 (volume –/+) button
  17. USB slide lever
  18. JUMP (time jump) button
  19. (microphone) jack*1
  20. (headphones) jack
  21. microSD card slot (The card slot is located under the cover.)
  22. Slot cover
  23. Built-in speaker
  • *1 The  (play/enter) button, VOL + (volume +) button, and (microphone) jack have a tactile dot. Use the tactile dot as a reference when operating the IC recorder.
  • *2 Sliding the POWER•HOLD switch to “POWER” and holding it for 8 seconds or longer restarts your IC recorder. For detailed instructions, refer to the Help Guide.

Let’s try out your new IC recorder

Charge

Sony ICD-UX570 Digital Voice Recorder \(3\)

  1. Charge the IC recorder. Slide the USB slide lever in the direction of the arrow, and insert the USB connector into the USB port of a running computer. When the battery is fully charged, the battery indicator changes from the charging animation to “full”
  2. Disconnect the IC recorder. Make sure that the message “Accessing” is no longer on the display window. Then refer to the Help Guide to remove the IC recorder safely

Power on

Sony ICD-UX570 Digital Voice Recorder \(4\)

  • Slide and hold the POWER•HOLD switch in the direction of “POWER” until the window display appears.
  • To turn the power off, slide the POWER•HOLD switch to “POWER” and hold it until “Power Off” appears on the display window.
  • To prevent unintentional operations (HOLD)
  • Slide the POWER•HOLD switch in the direction of “HOLD.”
  • To release the IC recorder from the HOLD status, slide the POWER HOLD switch towards the center.

Initial settings

Sony ICD-UX570 Digital Voice Recorder \(6\)

When you power on your IC recorder for the first time, the “Configure Initial Settings” screen appears on the display window. You can then select the display language, set the clock, and turn on/off the beep sound.

  1. Press Play to start the initial settings.

  2. Select the display language.
    You can select from the following languages: English*, Español (Spanish), Français (French) Default setting

  3. Set the current year, month, day, hour, and minute. To go back to the previous clock setting item, press BACK/HOME.Sony ICD-UX570 Digital Voice Recorder \(8\)

  4. Select “Next.”

  5. Select “ON” or “OFF” to turn on or off the beep sound.

When the initial settings finish, the completion message and then the HOME menu screen appears.

Notes

  • If you take 30 seconds or longer before proceeding to the next step, the display window will turn off. To turn on the display window for continuing the initial settings, press BACK/HOME.
  • You can change any of the initial settings at any time later. For detailed instructions, refer to the Help Guide.

The display window turns off automatically

The “Screen Off Timer” setting on your IC recorder is set to  “30 Sec” by default to save battery power. If you leave the IC recorder untouched for 30 seconds, the display window will turn off, but you can still perform any button operations. To turn the display window back on, press BACK/HOME.  You can keep the display window from turning off or change the default setting to another timer interval. Press and hold BACK/ HOME and select “ Settings” – “Common Settings” – “Screen Off Timer,” and then select “No Auto Screen Off,” “15 Sec,” “30 Sec,” “1 Min,” “3 Min,” or “5 Min.”

Record

Sony ICD-UX570 Digital Voice Recorder \(12\)

  • Before you start recording, make sure that the HOLD status is released.
  • You can select a recording scene for each situation by selecting “Scene Select” in the OPTION menu.
  1. Select “Record” from the HOME menu. The recording standby screen appears.

  2. Select storage and a folder to save the recorded file. To save the recorded file on the microSD card, you need to change the file storage destination folder. Select “Recording Folder” – “SD Card” from the OPTIONS menu, and then start recording.Sony ICD-UX570 Digital Voice Recorder \(13\)

  3. Turn the IC recorder so that its built-in microphones point in the direction of the target sound source.

  4. Press REC/PAUSE. “REC” appears on the display window to indicate that recording has started, and the operation indicator lights in red.
    Note
    If you press and hold REC/PAUSE, the IC recorder will pause. It will not start recording.
    The recording level guide is displayed while recording. The section between + and + is the optimal input level for recording. Please adjust the orientation of the built-in microphones, the distance from the sound source, the microphones’ sensitivity setting, or the “Scene Select” setting so that the recording level fits within the optimal range, as illustrated.

  5. Press STOP to stop recording. “Saving…” and then recording standby screen appear on the display window.

Listen

Sony ICD-UX570 Digital Voice Recorder \(14\)

  1. Select “Recorded Files” from the HOME menu.
  2. Select “Latest Recording,” “Search by REC Date,” “Search by REC Scene,” or “Folders.”
  3. Select your desired file.Sony ICD-UX570 Digital Voice Recorder \(15\)

Playback starts and the operation indicator lights in green.

  1. Press VOL + or VOL – to adjust the volume.
  2. Press STOP to stop playback. Right after you stopped recording, you can press to play the file you have just recorded.

To add a track mark

You can add a track mark at a point at which you want to divide a file later or locate during playback. You can add a maximum of 98 track marks to each file. You can also add track marks during recording.

Locating the desired playback point quickly (Time Jump, Easy Search)

  • Using the time jump function allows you to move to any of the 10 points throughout the total duration of a file. You can use this function with in the time jump mode.
  • Using the easy search function allows you to forward or reverse a fixed number of seconds (10 seconds for forwarding, 3 seconds for reversing) during playback.

Delete

Sony ICD-UX570 Digital Voice Recorder \(16\)

Note

Once a file is deleted, you cannot restore it.

  1. Select the file you want to delete from the list of recorded files or play back the file you want to delete.
  2. Select “Delete File” from the OPTION menu. “Delete?” appears and the selected file starts playing for your confirmation.
  3. Select “Yes.” “Please Wait” appears and stays until the selected file is deleted.Sony ICD-UX570 Digital Voice Recorder \(18\)

Using the HOME menu

You can use the HOME menu for a variety of operations, including locating and playing a recorded file and changing the settings of your IC recorder.Sony
ICD-UX570 Digital Voice Recorder \(19\)

  1. Press and hold BACK/HOME. The HOME menu screen appears.
  2. The HOME menu items are aligned in the following sequence.Sony ICD-UX570 Digital Voice Recorder \(21\)
  3. Select your desired function from the following:Sony ICD-UX570 Digital Voice Recorder \(22\)

Using the OPTION menu

You can use the OPTION menu to perform a variety of functions, including changing the settings of your IC recorder. The available items differ depending on the situationSony ICD-UX570 Digital Voice Recorder
\(23\)

  1. Select your desired function from the HOME menu, and then press OPTION.
  2. Select the menu item for which you want to change the setting.
  3. Select your desired setting option.

Copying files from your IC recorder to a computer

You can copy the files and folders from your IC recorder to a computer to store them.

  1. Follow the instructions in “Charge” to connect your IC recorder to a computer.
  2. Drag and drop the files or folders you want to copy from “IC RECORDER” or “MEMORY CARD” to the local disk on the computer.Sony ICD-UX570 Digital Voice Recorder \(25\)
  3. To copy a file or folder (Drag and drop) Disconnect your IC recorder from the computer.

Installing Sound Organizer 2

Install Sound Organizer on your computer. Sound Organizer allows you to exchange files between your IC recorder and your computer. Songs imported from music CDs and other media, MP3 and other audio files imported to a computer can also be played and transferred to the IC recorder.

Notes

  • Sound Organizer is compatible with Windows computers only. It is not compatible with Mac.
  • This IC recorder is compatible with Sound Organizer 2 only.
  • If you format the built-in memory, all data stored there will be deleted. (The Sound Organizer software installer will also be deleted.)
  • When installing Sound Organizer, log in to an account with administrator privileges.
  • The installation procedure varies depending on the Windows version. The following procedure uses Windows 10 as an example.
  1. Follow the instructions in “Charge” to connect your IC recorder to a computer.
  2. Make sure the IC recorder is successfully detected by the computer. “Connecting” appears and stays on the IC recorder’s display window while the IC recorder is connected to the computer.
  3. Right-click at the bottom left corner of the desktop, and then click [File Explorer] on the menu.
  4. Double-click [IC RECORDER] – [FOR WINDOWS].
  5. Double-click [SoundOrganizer_V2002] (or [SoundOrganizer_V2002. exe]). Follow the computer’s on-screen instructions.
  6. When the [Welcome to Sound Organizer 2 Installer] window appears, click [Next].
  7. Make sure that you accept the terms of the license agreement, select [I accept the terms in the license agreement], and then click [Next].
  8. When the [Setup Type] window appears, select [Standard] or [Custom], and then click [Next]. Follow the instructions on the screen and set the installation settings when you select [Custom].
  9. When the [Ready to Install the Program] window appears, click [Install]. The installation starts.
  10. When the [Sound Organizer 2 has been installed successfully.] window appears, check [Launch Sound Organizer 2 Now], and then click [Finish].

Note
You may need to restart your computer after installing Sound Organizer 2.

Precautions

On power

  • DC 3.7V: the built-in rechargeable lithium-ion battery DC 5.0V:  when charged using USB
  • Rated current consumption: 500mA

On handling

  • Do not leave the unit in a location near heat sources, or in a place subject to direct sunlight, excessive dust or mechanical shock.
  • Should any solid object or liquid fall into the unit, remove the battery and have the unit checked by qualified personnel before operating it any further.
  • When using your IC recorder, remember to follow the precautions below in order to avoid warping the cabinet or causing the IC recorder to malfunction.
    • Do not sit down with the IC recorder in your back pocket.
    • Do not put your IC recorder into a bag with the headphones/earphones cord wrapped around it and subject the bag to strong impact.
  • Be careful not to allow water to splash on the unit. The unit is not waterproof. In particular, be careful in the following situations.
  • When you have the unit in your pocket and go to the bathroom, etc. When you bend down, the unit may drop into the water and may get wet.

When you use the unit in an environment where the unit is exposed to rain, snow, or humidity.

In circumstances where you get sweaty. If you touch the unit with wet hands or if you put the unit in the pocket of sweaty clothes, the unit may get wet.

  • Listening with this unit at high volume may affect your hearing.
  • For traffic safety, do not use this unit while driving or cycling.
  • Do not use this unit at a place where the inability to hear surrounding sounds may present a danger.
  • You may feel pain in your ears if you use the headphones when the ambient air is very dry.

This is not because of a malfunction of the headphones, but because of static electricity accumulated in your body. You can reduce static electricity by wearing non-synthetic clothes that prevent the emergence of static electricity.

  • Do not place this product close to medical devices.

This product (including accessories) has magnet(s) which may interfere with pacemakers, programmable shunt valves for hydrocephalus treatment, or other medical devices. Do not place this product close to persons who use such medical devices. Consult your doctor before using this product if you use any such medical device.

On noise

  • Noise may be heard when the unit is placed near an AC power source, a fluorescent lamp or a mobile phone during recording or playback.
  • Noise may be recorded when an object, such as your finger, etc., rubs or scratches the unit during recording.

On maintenance

To clean the exterior, use a soft cloth slightly moistened in water. Then use a soft dry cloth to wipe the exterior. Do not use alcohol, benzine or thinner. If you have any questions or problems concerning your unit, please consult your nearest Sony dealer.

WARNING
Do not expose the batteries (battery pack or batteries installed) to excessive heat such as sunshine, fire or the like for a long time.

CAUTION
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

FOR UNITED STATES CUSTOMERS. NOT APPLICABLE IN CANADA, INCLUDING IN THE PROVINCE OF QUEBEC.

If you have any questions about this product:

Visit: https://www.sony.com/electronics/support

Contact: Sony Customer Information Service Center at 1-800-222-7669 Write: Sony Customer Information Service Center 12451 Gateway Blvd., Fort Myers, FL 33913

Supplier’s Declaration of Conformity

Trade Name: SONY

Model: ICD-UX570

Responsible Party: Sony Electronics Inc.

Address: 16535 Via Esprillo, San Diego, CA 92127 U.S.A.

Telephone Number: 858-942-2230

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC INFORMATION

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RECYCLING RECHARGEABLE BATTERIES
Rechargeable batteries are recyclable. You can help preserve our environment by returning your used rechargeable batteries to the collection and recycling location nearest you. For more information regarding recycling of rechargeable batteries, visit https://www.sony.com/electronics/eco /environmental-management

Caution: Do not handle damaged or leaking rechargeable batteries.

Notice for users

  • All rights reserved. This manual or the software described herein, in whole or in part, may not be reproduced, translated or reduced to any machine readable form without prior written approval from Sony Corporation.
  • What you record is for personal enjoyment and use only. Copyright laws prohibit other forms of use without the permission of the copyright holders.

Trademarks and licenses

  • Microsoft, Windows and Windows Media are registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
  • macOS is a trademark of Apple Inc., registered in the U.S. and other countries.
  • microSD, microSDHC and microSDXC logos are trademarks of SD-3C, LLC.
  • All other trademarks and registered trademarks are trademarks or registered trademarks of their respective holders. Furthermore, “™” and “®” are not mentioned in each in this manual.
  • MPEG Layer-3 audio coding technology and patents licensed from Fraunhofer IIS and Thomson.
  • This product is protected by certain intellectual property rights of Microsoft Corporation. Use or distribution of such technology outside of this product is prohibited without a license from Microsoft or an authorized Microsoft subsidiary.

Notes on the License
This IC recorder comes with software that are used based on licensing agreements with the owners of that software.
Based on requests by the owners of copyright of these software applications, we have an obligation to inform you of the following. Please read the following sections.
Licenses (in English) are recorded in the built-in memory of your IC recorder. Establish a Mass Storage connection between the IC recorder and a computer to read licenses in the “LICENSE” folder.

On GNU GPL/LGPL applied software

The software that is eligible for the following GNU General Public License (hereinafter referred to as “GPL”) or GNU Lesser General Public License (hereinafter referred to as “LGPL”) are included in the IC recorder. This informs you that you have a right to have access to, modify, and redistribute source code for these software programs under the conditions of the supplied GPL/LGPL.

Source code is provided on the web. Use the following URL to download it. http://www.sony.net/Products/Linux/
We would prefer you do not contact us about the contents of source code. Licenses (in English) are recorded in the built-in memory of your IC recorder. Establish a Mass Storage connection between the IC recorder and a computer to read licenses in the “LICENSE” folder.

FREQUENTLY ASKED QUESTIONS

Does the mic-in jack record in mono or stereo?
It can record both.

Does this recorder have external speaker for audio playback?
Yes, it features a built-in speaker.

Can I record at 192 kbps?
Yes, you can record at 192kbps

Can you silence the button noise?
Yes, you can.

Does this recorder have an easy-to-use or simple mode?
No, it doesn’t have a simple mode.

Do I need memory card ?
The device features an internal memory of 4 GB. If you require more, you can use a memory card.

Is it compatible with the Rode Videomic Go?
Yes, it is compatible with Rode Videomic Go.

https://www.sony.com/electronics/support/res/manuals/5006/733dc8893042024a01eabc32b2a0b81c/50069434M.pdf

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals