ELCOP RD350VAAU Rotary Controlled LED Dimmer 350 VA Installation Guide
- June 6, 2024
- ELCOP
Table of Contents
ELCOP RD350VAAU Rotary Controlled LED Dimmer 350 VA
Product Range
Product No.
|
Description
---|---
AU-RD350VA| Rotary Controlled LED Dimmer, 350 VA
Description
- Modular dimming mechanism.
- Two-wire phase control wall plate dimmer.
- Soft-start for lamp and driver life.
- Provide optimised dimming of LED based lamps and drivers.
- Compatibility with incandescent lamps, 240V halogen lamps, Low voltage halogen lamp with dimmable electronic transformer, etc.
- Wall or architrave mounting options.
- Wide range of plate styles and colour variants available.
- Suitable for new installations or retro-fit applications.
- Inbuilt Over-Current and Over-Temperature protection.
- Full short circuit protection.
- Immune to high frequency (ripple) signal injection on mains supply.
- Complies with Australian and International EMC Standards.
Electrical Specification
Parameter
|
Value
---|---
Nominal Operating Voltage|
220-240 V ac
Nominal Operating Frequency|
50 Hz
Maximum Load|
350 VA @1 Gang Derate for multi-gang applications
Minimum Load|
10 VA
Dimming Technique|
Trailing Edge Phase Control
Mounting Centres|
84mm Australian Pattern Plate
Safety Compliance|
AS/NZS 3100, AS/NZS 3133, IEC 60669-2-1
EMC Compliance| AS/NZS CISPR15, IEC 60669-2-1 (26.1, 26.2), IEC 61000-3-2 (Excepting when used in conjunction with Electronic loads)
Specifications Typical @ 240 V ac 25℃
Suitable for Indoor Use Only
No User Serviceable Parts Inside
Load Compatibility
Load Symbol
| Compatible Loads| AU-RD350VA
---|---|---
Maximum Load|
Minimum Load
| Dimmable LED Lighting|
150 W
|
10 W
| Incandescent Lighting 240 V Halogen Lamps|
350 W
|
10 W
| Low Voltage Halogen Lightingwith Electronic Transformers|
350 VA
|
10 VA
Wiring Diagram
One-Way Wiring Diagram
Two-way Wiring Diagram
NOTE:
- The LED dimmer series are designed for One-Way or Two-Way operation as above diagrams.
- Two or more dimmers cannot be connected in paralle or series to control the same load from two different locations.
- Dimmer Mechanism wiring is NOT polarity sensitive
It is illegal for persons other than an appropriately licensed electrical contractor or other persons authorised by legislation to work on the fixed wiring of any electrical installation. Penalties for conviction are severe!
Installation
To connect the required lighting loads, then follow the following steps:
Step 1
Leave the dimmer connected, but remove the dimming knob from the dimming shaft
Step 2
Turn the dimmer shaft anti-clockwise until the available installation level is
reached.
Step 3
Align the plane on the front face of the dimmer with the plane on the inside
of the dimmer knob
Step 4
Push the dimmer knob back onto the shaft such that the plane remain aligned
Warranty Statement
- This product is guaranteed against faulty workmanship and materials for a period of two years from the date of installation.
- This warranty is expressly subject to the product being installed, wired, tested,operated and used in accordance with the manufacturer’s instructions.