Specifications

  • Battery: LiFePO4 3214015Ah
  • Burst mode Quantity: 5P15S
  • Capacity: 3600Wh
  • Voltage: 48V
  • Current range: 55A Max, 140A Max
  • Voltage range: 38-53V
  • Temperature range: -20°C to 50°C
  • Cycles: 6000 cycles to 80%+ capacity
  • Display: LCD Screen
  • Lamp: LED
  • Connectivity: Wifi/Bluetooth
  • Key Features: Touch Screen, Main Power switch on/off, AC out on/off
  • Weight: 48kg
  • Dimensions (LxWxD): 58.8cm x 40cm x 42.4cm
  • Certification: Europe: IEC62619, IEC62477, CERED, IEC60730; North America: UL2743, UL1973, UL9540, UL9540A,FCC ID

Product Usage Instructions

Initial Setup

  • Ensure the product is placed on a stable surface and connected to a power source.

Powering On/Off

  • To power on the device, toggle the Main Power switch to the “on” position. To turn it off, switch it to the “off” position.

Display Usage

  • The LCD screen displays the battery level and usage status. Use the touch screen for navigation.

Connectivity

  • Connect to Wifi/Bluetooth for additional functionalities and remote monitoring.

Frequently Asked Questions (FAQ)

Q: What should I do if the product does not power on?

  • A: Ensure the Main Power switch is in the correct position and check the power source connection.

Q: How can I monitor the battery level?

  • A: The LCD screen provides real-time information on the battery level.

Version management

Versions Date Change Check Approver Change Content
V1.0 2024.1.22 Qinwei     Alpha Version
         
         
  • The copyright of this document belongs to RUNHOOD POWER INC. Violation of rights will be prosecuted.

Definition Of Product

Application scenarios

  • Application scenario 1: Used as an outdoor mobile energy storage power source. Supports input methods such as AC charging, photovoltaic charging, and vehicle charging. Supports DC output such as USB, DC12V, DC24V, and AC output. Can be moved and stacked for use.
  • Application scenario 2: As a backup application for UPS households. Home power grid connected to RUNHOOD system application: It serves as a UPS for the home power grid, with two sets of hosts and battery packs.
  • Application scenario 3: Home energy storage grid-connected application. The RUNHOOD battery in the home photovoltaic energy storage system can replace (or be newly installed) the battery part of the energy storage system:

System block diagram

RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-
FIG-1

F3600 Residential ESS & Portable Power Station

Composed of battery pack, inverter, DC interface, parallel interface, etc.

Product Appearance

RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-
FIG-2

  • Note: The type of AC socket varies in each country and region, and the actual product shall prevail.

Principle block diagram

RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-
FIG-3

Specification parameters

F3600

Battery| Cell| LiFePO4(32140,15Ah)
Burst mode| 5P15S
Quantity electricity| 3600Wh(48V,75Ah)
Current Range| 55A Max 140A Max
Voltage range| 38-53V
Temperature range| 2℃~50℃-28℃~50℃
Cycles| 6000 cycles to 80%+ capacity
LCD Screen| LCD| Support(Touch Screen)
Lamp| LED| Support
Wifi/Bluetooth|  | Support
Key| Key1| Main Power switch on/off
Key2| AC out on/off
 | Key3| DC out on/off
---|---|---
Key4| USB-A/C out on/off
DC| Input Ports| 12–150V 25A Max, 2400W Max,
Car Charger, 12/24V 8.5A Max
Output Ports| USB-A 12W Max 2
USB-B 28W Max
2
USB-C 100W Max * 2
Anderson 12/24V 30A Max
Car Charger 12V 10A
AC| Input Ports| F3600-US

110V~120Vac,60Hz,15A Max, 1800W Max

F3600-JP

100Vac,50/60Hz,15A Max, 1500W Max

F3600-EU、F3600-UK、F3600-AU

230Vac,50Hz,10A Max, 2300W Max

Output Ports| F3600-US

120VAC, 60Hz, 3600W (7200W Surge), 20A

Max 4, 30A Max 1

EV INPUT| AC| 3400W Max
BACK -UP

OUTPUT

| AC| 3600W Max
Extra Battery

Port(*2)

|  | Power and Communications
External communication|  | RJ45 *3

Com1: Debug port Com2: Debug port Com3: Reserve

Grounding

point

|  | Earthing mark
Dip switch|  | Address coding & terminal resistance
Weight|  | 48kg
Dimensions

(LxWxD)

|  | 58.8cm40cm42.4cm
Certification|  | Europe IEC62619、IEC62477、CE(RED)、IEC60730

North America UL2743、UL1973、UL9540、UL9540A、FCC ID

Function description

  1. LCD display screen
    • Display the product’s battery level and usage status prompts.RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-FIG-4RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-FIG-5RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-FIG-6RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-FIG-7 RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-FIG-8 RUNHOOD-F3600-US-Residential-ESS-and-Portable-Power-Station-FIG-9
  2. AC output switch (hold down to turn on or off) AC output indicator light
    • The AC power button controls the AC power output of F3600. To enable AC power, click the AC power button. When the AC power supply of F3600 is enabled, the AC indicator light will light up.
    • When Overload occurs or the battery level is 0%, the AC output and AC indicator lights will turn off. When the battery level returns to above 2%, the AC output can return to normal.
  3. AC output socket
    • Power devices such as laptops, televisions, mini refrigerators, vacuum cleaners, etc. through communication sockets.
    • Supports the use of 3600W electrical appliances for power reduction (does not support all excess appliances, needs to be tested and confirmed to be usable to avoid affecting your work and life).
  4. LED lights
    • The use of LED lights adopts a flip type. Flip up and turn on the light. The light intensity can be adjusted through the touch screen.
  5. Main power button
    • Press and hold the power button to turn on or off B3600. Power on: short press for 1.5 seconds. Power off: long press for 3 seconds. Forced power off long press for 10 seconds.
    • When F3600 is turned on, the power indicator light shows a breathing state and the display screen lights up; After F3600 is idle for more than 2 minutes, the backlight of the F3600 screen will be turned off, but the host is still running;
    • After F3600 is idle for more than 5 minutes, the F3600 host will automatically shut down.
  6. DC charging input port
    • Specification XT60EW-M can be charged to the power supply through the dedicated connection cable of RUNHOOD’s built-in car charging port and can be charged to the power supply through a photovoltaic panel.
    • The copyright of this document belongs to RUNHOOD POWER INC. Violation of rights will be prosecuted.
    • Supports input of 12V/24V maximum 8.5A in-car power supply (make sure to start the car when using it to avoid battery depletion and inability to start).
    • Supports solar panel series parallel input, voltage range: 15-150Vdc, current: 25A Max, power: 2400W Max, supports MPPT.
  7. DC output switch key (vehicle charging output port, 2 Anderson output ports) and DC output port indicator light
    • Press and hold the DC switch to turn on or off the F3600 DC power output, while lighting up the indicator light for the DC output.
    • This button controls the DC output of the F3600 car charging port and two Anderson DC outputs.
    • When there is an overload alarm prompt on the DC side output, pressing this button can clear the alarm prompt.
  8. Car charging output port
    • The car charging port supports a maximum current output of 10A and can be used for general on-board appliances.
  9. Anderson output port
    • Provide power to various high-power DC power devices, such as car-mounted DC refrigerators.
    • At the same time, it can also charge 12V lead-acid batteries for cars or 24V lead-acid batteries for trucks (must be operated under the guidance of professionals).
  10. USB output switch (USB-A output port and USB-C output port) and USB output port indicator light
    • The copyright of this document belongs to RUNHOOD POWER INC. Violation of rights will be prosecuted.
    • Press and hold the USB switch to turn on or off the USB output of F3600, while also lighting up the USB output indicator light. This button controls the USB-A and USB-C outputs of F3600.
    • When there is an overload alarm prompt on the USB output, pressing this button can clear the alarm prompt.
  11. USB-A output port
    • Charge various devices, such as iPhones, tablets, GoPro, speakers, or any other device that charges through the USB-A port.
  12. Fast-charging 100W USB-C output port
    • Output: USB-C can charge devices including MacBook Pro, Android phones, and any other USB-C port.
  13. Ventilation and heat dissipation holes
    • The heat dissipation hole can prevent F3600 from overheating.
  14. Buzzer output
    • The system comes with a buzzer for reminders when turning on and off.
  15. Parallel interface
    • The parallel interface is divided into an upper connection port (Port-1) and a lower connection port (Port-2).
    • The specific interface information is shown in the table below.

Description of the upper port (Port-1) Pins

Serial Content Describe
1 P+ Power +
2 P- Power –
--- --- ---
Serial Content Describe
--- --- ---
1 CAN0_H CAN0_H
2 CAN0_L CAN0_L
3 M_TX Uplink sending signa
4 M_RX Uplink receive signal
5 GND Ground wire
6 M_DET Uplink judgment signal
7 SYN_ON System start signal
8 GND Ground wire

Description of the Lower Port (Port-2) Pins

Serial Content Describe
1 P+ Power +
2 P- Power –
Serial Content Describe
--- --- ---
1 CAN0_H CAN0_H
2 CAN0_L CAN0_L
3 S_RX Downlink receive signal
4 S_TX Downlink sending signa
5 S_DET Downlink judgment signal
6 SYN_ON System start signal
7 GND Ground wire
8 GND Ground wire

Communication Interface

  • The RJ45 interface includes three interfaces: the communication port for the extended inverter (COM1), the debugging port (COM2), and the wet-dry port (COM3). The specific information is shown in the table below.

RJ45-1(COM1) Debugging port pin description

Serial Content Describe
1 NC /
2 NC /
3 NC /
4 CAN1_H CAN1_H
5 CAN1_L CAN1_L
6 NC /
7 RS485_A RS485 Signal
8 RS485_B RS485 Signal

RJ45-2(COM2) Debugging port pin description

Serial Content Describe
1 CAN0_H CAN0_H
2 CAN0_L CAN0_L
3 GND Ground wire
4 RS485_B1 RS485_B1
5 RS485_A1 RS485_A1
6 ACT Wake up
7 GND Ground wire
8 RESET Reset

RJ45-3(COM3) Description of dry and wet port pins

Serial Content Describe
1 NO1 Output signals 1
2 COM1 Output signals 1(COM)
3 NO2 Output signals 2
--- --- ---
4 COM2 Output signals 2(COM)
5 DIN+ Output signals 1+
6 DIN1 Output signals 1
7 DIN+ Output signals 2+
8 DIN2 Output signals 2

DIP switch

  • 6-digit DIP switch, 1-4 is the address DIP switch, 5 is reserved, and 6 is the communication terminal resistor 120 Ω access switch.
  • The effective address of the address dial switch is 1-8, and 9-15 is temporarily an invalid address.
  • When multiple battery packs are working in parallel, it is necessary to encode the addresses of each main control module.
  • The encoding method and instructions are shown in the table below.

Schematic diagram of dial switch

coding site Add.
1 2
ON OFF
OFF ON
ON ON
OFF OFF
ON OFF
OFF ON
ON ON
OFF OFF

Appendix

Disclaimer

The length of all external cables shall not exceed 3m.

FCC Caution

Labeling requirements

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.

Changes or modification warning.

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Information to the user

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RF warning for Mobile devices:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RUNHOOD User Manuals

Related Manuals