RUNHOOD F3600-US Residential ESS and Portable Power Station Instruction Manual
- June 1, 2024
- RUNHOOD
Table of Contents
RUNHOOD F3600-US Residential ESS and Portable Power Station
Specifications
- Battery: LiFePO4 3214015Ah
- Burst mode Quantity: 5P15S
- Capacity: 3600Wh
- Voltage: 48V
- Current range: 55A Max, 140A Max
- Voltage range: 38-53V
- Temperature range: -20°C to 50°C
- Cycles: 6000 cycles to 80%+ capacity
- Display: LCD Screen
- Lamp: LED
- Connectivity: Wifi/Bluetooth
- Key Features: Touch Screen, Main Power switch on/off, AC out on/off
- Weight: 48kg
- Dimensions (LxWxD): 58.8cm x 40cm x 42.4cm
- Certification: Europe: IEC62619, IEC62477, CERED, IEC60730; North America: UL2743, UL1973, UL9540, UL9540A,FCC ID
Product Usage Instructions
Initial Setup
- Ensure the product is placed on a stable surface and connected to a power source.
Powering On/Off
- To power on the device, toggle the Main Power switch to the “on” position. To turn it off, switch it to the “off” position.
Display Usage
- The LCD screen displays the battery level and usage status. Use the touch screen for navigation.
Connectivity
- Connect to Wifi/Bluetooth for additional functionalities and remote monitoring.
Frequently Asked Questions (FAQ)
Q: What should I do if the product does not power on?
- A: Ensure the Main Power switch is in the correct position and check the power source connection.
Q: How can I monitor the battery level?
- A: The LCD screen provides real-time information on the battery level.
Version management
Versions | Date | Change | Check | Approver | Change Content |
---|---|---|---|---|---|
V1.0 | 2024.1.22 | Qinwei | Alpha Version | ||
- The copyright of this document belongs to RUNHOOD POWER INC. Violation of rights will be prosecuted.
Definition Of Product
Application scenarios
- Application scenario 1: Used as an outdoor mobile energy storage power source. Supports input methods such as AC charging, photovoltaic charging, and vehicle charging. Supports DC output such as USB, DC12V, DC24V, and AC output. Can be moved and stacked for use.
- Application scenario 2: As a backup application for UPS households. Home power grid connected to RUNHOOD system application: It serves as a UPS for the home power grid, with two sets of hosts and battery packs.
- Application scenario 3: Home energy storage grid-connected application. The RUNHOOD battery in the home photovoltaic energy storage system can replace (or be newly installed) the battery part of the energy storage system:
System block diagram
F3600 Residential ESS & Portable Power Station
Composed of battery pack, inverter, DC interface, parallel interface, etc.
Product Appearance
- Note: The type of AC socket varies in each country and region, and the actual product shall prevail.
Principle block diagram
Specification parameters
F3600
Battery| Cell| LiFePO4(32140,15Ah)
Burst mode| 5P15S
Quantity electricity| 3600Wh(48V,75Ah)
Current Range| 55A Max 140A Max
Voltage range| 38-53V
Temperature range| 2℃~50℃-28℃~50℃
Cycles| 6000 cycles to 80%+ capacity
LCD Screen| LCD| Support(Touch Screen)
Lamp| LED| Support
Wifi/Bluetooth| | Support
Key| Key1| Main Power switch on/off
Key2| AC out on/off
| Key3| DC out on/off
---|---|---
Key4| USB-A/C out on/off
DC| Input Ports| 12–150V 25A Max, 2400W Max,
Car Charger, 12/24V 8.5A Max
Output Ports| USB-A 12W Max 2
USB-B 28W Max 2
USB-C 100W Max * 2
Anderson 12/24V 30A Max
Car Charger 12V 10A
AC| Input Ports| F3600-US
110V~120Vac,60Hz,15A Max, 1800W Max
F3600-JP
100Vac,50/60Hz,15A Max, 1500W Max
F3600-EU、F3600-UK、F3600-AU
230Vac,50Hz,10A Max, 2300W Max
Output Ports| F3600-US
120VAC, 60Hz, 3600W (7200W Surge), 20A
Max 4, 30A Max 1
EV INPUT| AC| 3400W Max
BACK -UP
OUTPUT
| AC| 3600W Max
Extra Battery
Port(*2)
| | Power and Communications
External communication| | RJ45 *3
Com1: Debug port Com2: Debug port Com3: Reserve
Grounding
point
| | Earthing mark
Dip switch| | Address coding & terminal resistance
Weight| | 48kg
Dimensions
(LxWxD)
| | 58.8cm40cm42.4cm
Certification| | Europe IEC62619、IEC62477、CE(RED)、IEC60730
North America UL2743、UL1973、UL9540、UL9540A、FCC ID
Function description
- LCD display screen
- Display the product’s battery level and usage status prompts.
- AC output switch (hold down to turn on or off) AC output indicator light
- The AC power button controls the AC power output of F3600. To enable AC power, click the AC power button. When the AC power supply of F3600 is enabled, the AC indicator light will light up.
- When Overload occurs or the battery level is 0%, the AC output and AC indicator lights will turn off. When the battery level returns to above 2%, the AC output can return to normal.
- AC output socket
- Power devices such as laptops, televisions, mini refrigerators, vacuum cleaners, etc. through communication sockets.
- Supports the use of 3600W electrical appliances for power reduction (does not support all excess appliances, needs to be tested and confirmed to be usable to avoid affecting your work and life).
- LED lights
- The use of LED lights adopts a flip type. Flip up and turn on the light. The light intensity can be adjusted through the touch screen.
- Main power button
- Press and hold the power button to turn on or off B3600. Power on: short press for 1.5 seconds. Power off: long press for 3 seconds. Forced power off long press for 10 seconds.
- When F3600 is turned on, the power indicator light shows a breathing state and the display screen lights up; After F3600 is idle for more than 2 minutes, the backlight of the F3600 screen will be turned off, but the host is still running;
- After F3600 is idle for more than 5 minutes, the F3600 host will automatically shut down.
- DC charging input port
- Specification XT60EW-M can be charged to the power supply through the dedicated connection cable of RUNHOOD’s built-in car charging port and can be charged to the power supply through a photovoltaic panel.
- The copyright of this document belongs to RUNHOOD POWER INC. Violation of rights will be prosecuted.
- Supports input of 12V/24V maximum 8.5A in-car power supply (make sure to start the car when using it to avoid battery depletion and inability to start).
- Supports solar panel series parallel input, voltage range: 15-150Vdc, current: 25A Max, power: 2400W Max, supports MPPT.
- DC output switch key (vehicle charging output port, 2 Anderson output ports) and DC output port indicator light
- Press and hold the DC switch to turn on or off the F3600 DC power output, while lighting up the indicator light for the DC output.
- This button controls the DC output of the F3600 car charging port and two Anderson DC outputs.
- When there is an overload alarm prompt on the DC side output, pressing this button can clear the alarm prompt.
- Car charging output port
- The car charging port supports a maximum current output of 10A and can be used for general on-board appliances.
- Anderson output port
- Provide power to various high-power DC power devices, such as car-mounted DC refrigerators.
- At the same time, it can also charge 12V lead-acid batteries for cars or 24V lead-acid batteries for trucks (must be operated under the guidance of professionals).
- USB output switch (USB-A output port and USB-C output port) and USB output port indicator light
- The copyright of this document belongs to RUNHOOD POWER INC. Violation of rights will be prosecuted.
- Press and hold the USB switch to turn on or off the USB output of F3600, while also lighting up the USB output indicator light. This button controls the USB-A and USB-C outputs of F3600.
- When there is an overload alarm prompt on the USB output, pressing this button can clear the alarm prompt.
- USB-A output port
- Charge various devices, such as iPhones, tablets, GoPro, speakers, or any other device that charges through the USB-A port.
- Fast-charging 100W USB-C output port
- Output: USB-C can charge devices including MacBook Pro, Android phones, and any other USB-C port.
- Ventilation and heat dissipation holes
- The heat dissipation hole can prevent F3600 from overheating.
- Buzzer output
- The system comes with a buzzer for reminders when turning on and off.
- Parallel interface
- The parallel interface is divided into an upper connection port (Port-1) and a lower connection port (Port-2).
- The specific interface information is shown in the table below.
Description of the upper port (Port-1) Pins
Serial | Content | Describe |
---|---|---|
1 | P+ | Power + |
2 | P- | Power – |
--- | --- | --- |
Serial | Content | Describe |
--- | --- | --- |
1 | CAN0_H | CAN0_H |
2 | CAN0_L | CAN0_L |
3 | M_TX | Uplink sending signa |
4 | M_RX | Uplink receive signal |
5 | GND | Ground wire |
6 | M_DET | Uplink judgment signal |
7 | SYN_ON | System start signal |
8 | GND | Ground wire |
Description of the Lower Port (Port-2) Pins
Serial | Content | Describe |
---|---|---|
1 | P+ | Power + |
2 | P- | Power – |
Serial | Content | Describe |
--- | --- | --- |
1 | CAN0_H | CAN0_H |
2 | CAN0_L | CAN0_L |
3 | S_RX | Downlink receive signal |
4 | S_TX | Downlink sending signa |
5 | S_DET | Downlink judgment signal |
6 | SYN_ON | System start signal |
7 | GND | Ground wire |
8 | GND | Ground wire |
Communication Interface
- The RJ45 interface includes three interfaces: the communication port for the extended inverter (COM1), the debugging port (COM2), and the wet-dry port (COM3). The specific information is shown in the table below.
RJ45-1(COM1) Debugging port pin description
Serial | Content | Describe |
---|---|---|
1 | NC | / |
2 | NC | / |
3 | NC | / |
4 | CAN1_H | CAN1_H |
5 | CAN1_L | CAN1_L |
6 | NC | / |
7 | RS485_A | RS485 Signal |
8 | RS485_B | RS485 Signal |
RJ45-2(COM2) Debugging port pin description
Serial | Content | Describe |
---|---|---|
1 | CAN0_H | CAN0_H |
2 | CAN0_L | CAN0_L |
3 | GND | Ground wire |
4 | RS485_B1 | RS485_B1 |
5 | RS485_A1 | RS485_A1 |
6 | ACT | Wake up |
7 | GND | Ground wire |
8 | RESET | Reset |
RJ45-3(COM3) Description of dry and wet port pins
Serial | Content | Describe |
---|---|---|
1 | NO1 | Output signals 1 |
2 | COM1 | Output signals 1(COM) |
3 | NO2 | Output signals 2 |
--- | --- | --- |
4 | COM2 | Output signals 2(COM) |
5 | DIN+ | Output signals 1+ |
6 | DIN1 | Output signals 1 |
7 | DIN+ | Output signals 2+ |
8 | DIN2 | Output signals 2 |
DIP switch
- 6-digit DIP switch, 1-4 is the address DIP switch, 5 is reserved, and 6 is the communication terminal resistor 120 Ω access switch.
- The effective address of the address dial switch is 1-8, and 9-15 is temporarily an invalid address.
- When multiple battery packs are working in parallel, it is necessary to encode the addresses of each main control module.
- The encoding method and instructions are shown in the table below.
Schematic diagram of dial switch
coding site | Add. |
---|---|
1 | 2 |
ON | OFF |
OFF | ON |
ON | ON |
OFF | OFF |
ON | OFF |
OFF | ON |
ON | ON |
OFF | OFF |
Appendix
Disclaimer
The length of all external cables shall not exceed 3m.
FCC Caution
Labeling requirements
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference,
- this device must accept any interference received, including interference that may cause undesired operation.
Changes or modification warning.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Information to the user
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, according to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a The copyright of this document belongs to RUNHOOD POWER INC.
violation of rights will be prosecuted residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not
installed and used under the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF warning for Mobile devices:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.