GOODWE HK1000 Smart Meter Homekit Installation Guide

June 5, 2024
GOODWE

Quick Installation Guide
Smart Meter
(HK1000/HK3000)
V1.0-2022-01-25

Product Introduction

Note:
CT1 – and CT1 + only for HK3000.

Installation

Packing List

installation and Cable Connection

Wiring System

HK1000

  • Recommended cable connected to the voltage input terminal: 1mm² (17AWG).
  • Do not remove the short circuit wire between L1 and L2.
  • CT direction: House (K)–>Grid (L).

HK3000

  • Recommended cable connected to the voltage input terminal: 1mm² (17AWG).
  • CT direction: House (K)–>Grid (L).

Commissioning

Power ON
Step 1 Connect the HomeKit cables.
Step 2 Power on the inverter and make sure that the inverter is working normally. Then the HomeKit is powered on.

Indicators

Indicator Status Description
Steady on Power on
Off Power off
Steady on Purchasing from the utility grid.
Blinking Selling to the utility grid. Or the communication between HomeKit

and the inverter is normal.
Off| No communication between HomeKit and the inverter.
| Single Blink| Communication between HomeKit and the inverter is normal.
Double Blink| HomeKit is trying to connect to the router.
quadruple Blink| HomeKit is trying to connect to the server.
Steady on| HomeKit has been connected to the server successfully.
Off| Parameters for connecting HomeKit to the router or the server have not been set.

Reset Button

Press Time Description
1-3s Reset the HomeKit communication module.
5s-10s Reset HomeKit configurations.
>15s Initialize HomeKit and clear the historical energy data.

Technical Parameters

Model HK1000 HK3000
Application Household Loads Monitoring+ARCB
Voltage Rated voltage 110V/230V I
Voltage Range 100V-240V
Frequency 50Hz/60Hz
Current Input Rated Current CT in: 120A/40mA

200A/66.7mA
Current Range| 0.48A-120A| 0.48A-120A/200A
Self-Consumption| <5W
Data Detection| Active Power/Reactive Power/Power Factor/Frequency
Energy Calculation| Active/Reactive Power Energy
Precision| Voltage/Current| Class I
Active Power| Class I
Reactive Power| Class II
Communication| 100M Ethernet
WiFi or LAN
Interface| 3 LED (Power, Energy Consumption, Communication),
USB port, Reset button
Mechanical| Size (Lmm x Wmm
x Flmm)| 36 x 85 x 66.5| –
Weight| 440g| –
Protection Class| IP20 (For indoor use)
Installation
Method| Mounting rack
Operating Temperature| -25 – +60° C
Operating Humidity| <95%, No condensation
Altitude| <2000m

EU Declaration of Conformity

The module sold in the European market meets the following directives and requirements:

  • Electromagnetic compatibility Directive 2014/30/EU (EMC)
  • Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
  • Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
  • Waste Electrical and Electronic Equipment 2012/19/EU
  • Registration, Evaluation, Authorization, and Restriction of Chemicals (EC) No 1907/2006 (REACH)
    You can download the EU Declaration of Conformity at https://en.goodwe.com.

For more detailed instructions, scan the QR codes below.

|
---|---
https://en.goodwe.com/Public/Uploads/sersups/
HomeKit%20Quick%20Configuration.pdf
| https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual
/GW_HK3000_User%20Manual- EN.pdf

|
https://en.goodwe.com/Public/Uploads/sersups/
User’s%20Guide%20of%20SolarGo%20App.pdf
| https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_SEMS%20Portal-User %20Manual-EN.pdf

https://en.goodwe.com/

GoodWe Technologies Co., Ltd.
No. 90 Zijin Rd., New District, Suzhou, 215011, China
www.goodwe.com
service@goodwe.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>