Neomounts Plasma M2250 Floor Stand Instruction Manual

June 5, 2024
Neomounts

Neomounts Logo PLASMA-M2250BLACK/SILVER
PLASMA-W2250BLACK/SILVER
PLASMA-M2500(T)BLACK/SILVER
PLASMA-W2500BLACK/SILVER
Instruction Manual
WWW.NEOMOUNTS.COM
Neomounts Plasma M2250 Floor Stand - Fig

PLASMA-M2250BLACK/SILVER

PARTS

STEP 1
Connect the trolley (E) to the column (D)Neomounts Plasma M2250 Floor
Stand - Fig 2 STEP 2
Attach upper bar (A) with slotted holes facing upwards and towards the screen.
Attach lower bar (B) with slotted holes facing floor and towards the screenNeomounts Plasma M2250 Floor Stand - Fig 3 STEP 3
Attach the “lift&lock”-brackets (C) to the display (I/J), before attaching them to the mount, and secure the bracket with the “lift&lock” systemNeomounts Plasma M2250 Floor Stand - Fig 4 STEP 4
Connect the 5-pole plug of the control unit (L) with the column. Connect the power cable (K) with column and socket![Neomounts Plasma M2250 Floor Stand

PLASMA-M2500BLACK/SILVER

PARTS

STEP 1
Connect the trolley (D) to the column (C) STEP 2
Assemble and install the frame (A) to the column (C)Neomounts Plasma
M2500 Floor Stand - Fig 8 STEP 3
Attach the “lift&lock”-brackets (B) to the display (H/I), before attaching them to the mount, and secure the bracket with the “lift&lock” systemNeomounts Plasma M2500 Floor Stand - Fig 9 STEP 4
Connect the 5-pole plug of the control unit (K) with the column. Connect the power cable (J) with column and socket STEP 5
For moving the unit up or down just press and keep pressing the buttons on the control unit (K)Neomounts Plasma M2500 Floor Stand - Fig
11

PLASMA-M2500TBLACK/SILVER

PARTS

STEP 1
Connect the trolley (D) to the column (C)

STEP 2
Install the frame (A) to the column (C)
STEP 3
Attach the vertical brackets (B) to the display (G/H), before attaching them to the mount and secure the bracket (F)Neomounts Plasma M2500T Floor
Stand - Fig 15 STEP 4
Connect the 5-pole plug of the control unit (J) with the column. Connect the power cable (I) with column and socketNeomounts Plasma M2500T Floor
Stand - Fig 16 STEP 5
For moving the unit just press and keep pressing the buttons on the control unit (J)

PLASMA-W2250BLACK/SILVER

PARTS

Neomounts Plasma W2250 Floor Stand - Fig 21 STEP 1
Connect the column (D) to the wallNeomounts Plasma W2250 Floor Stand -
Fig 22 STEP 2
Attach upper bar (A) with slotted holes facing upwards and towards the screen.
Attach lower bar (B) with slotted holes facing fl oor and towards the screenNeomounts Plasma W2250 Floor Stand - Fig 23

STEP 3
Attach the “lift&lock”-brackets (C) to the display (K/L), before attaching them to the mount and secure the bracket with the “lift&lock” system
STEP 4
Connect the 5-pole plug of the control unit (N) with the column. Connect the power cable (M) with column and socket![Neomounts Plasma W2250 Floor Stand

PLASMA-W2500BLACK/SILVER

PARTS

Neomounts Plasma M2500 Floor Stand - Fig 6 STEP 1
Connect the column (C) to the wall
Neomounts Plasma W2250 Floor Stand - Fig 19 STEP 2
Assemble and install the frame (A) to the column (C)Neomounts Plasma
W2250 Floor Stand - Fig 20 STEP 3
Attach the “lift&lock”-brackets (B) to the display (L/M), before attaching them to the mount, and secure the bracket with the “lift&lock” system STEP 4
Connect the 5-pole plug of the control unit (O) with the column. Connect the power cable (N) with column and socket![Neomounts Plasma W2250 Floor Stand

IMPORTANT HAZARD & SAFETY NOTES

Please carefully read the below hazard and safety notes before using the height adjustment unit.
This contributes to making the unit work failure-free and avoids accidents.
Electrical safety
Connect the unit to a free accessible 110 – 230 V / 50 Hz grounded power outlet only. Make sure, the unit can be immediately separated from the power outlet.
Only use the unit in dry rooms, and protect the unit from water and other liquids. Only wipe the unit with a dry cloth.
Do not open the lift unit. RISK OF ELECTRIC SHOCK. There are no serviceable parts inside.
In case of disfunction unplug the unit from the power outlet and call an authorized technical service person.
Do not overrun the line cord or damage it in any other way.
Replace damaged line cords immediately with a new one of the same type.
The socket connections of the unit and the wall socket must be easily accessible.
The device is not dripping or splash water protected.
Do not place objects filled with liquids on or spray the device.
General tips for mechanical safety
Do not improperly load the unit. Do not mount other than original parts (whiteboard, wings, interactive board, interactive monitor, projector) in conjunction with original mounting parts. Do not hang on the unit.
VERY HEAVY UNIT.
Severe risk of injury when a unit falls over due to improper usage. Only use original mounting parts provided with the system. Max load of lift unit is 150 kg/ 330 lbs. Do not exceed.
Assure installation of the unit by authorized service personnel only.
Before moving the unit up or down assure at least a safety distance of 20 cm/ 7.9 from any part of the unit to any other fitment in order to avoid shear traps or squeezing points.
In case of an accident please release the operating panel. The movement of the unit will stop immediately.
Special tips for moveable and free-standing units
Only operate the unit on a plane and on stable floors. Move unit on plane floors only.
Risk of tilting when overrunning floor evennesses, door sills, and similar.
VERY HEAVY UNIT.
Severe risk of injury when a unit falls over. Lock brakes of front wheels when the operating unit.
Special tips for wall mounted units
Use appropriate wall mounting material only. Choose dowels and screws according to the wall type and material. Using improper mounting material may result in tilting of the unit and a severe risk of injury.
Wall mounting must be done by experienced personnel only.
Instructions for disposal
Do not dispose of consumer waste.
CAUTION

  1. To ensure safety, please read this manual carefully before installation and follow the instructions. Store this manual in a secure place for future reference.

  2. The manufacturer shall not be legally responsible for any equipment damage or personal injury caused by incorrect installation or operation other than that covered in this manual.

  3. The mount is designed for easy installation and removal. The manufacturer shall not be liable for damage to equipment or personal injuries arising out of human factors or acts of nature, such as earthquakes or typhoons.

  4. It is recommended that the mount be installed by qualified personnel only.

  5. At least two persons are needed to install or remove the product to avoid the hazard of falling objects.

  6. Please carefully inspect the area where the mount is to be installed: – Avoid places that are subject to high temperatures, humidity, or contact with water.
    – Do not install the product near air conditioning vents or areas with excess dust and fumes.
    – Only install on vertical walls and avoid slanted surfaces.
    – Do not install in places subject to any shock or vibration.
    – Do not install in places subject to direct exposure to bright light, as it may cause eye fatigue when viewing the display panel.

  7. Maintain sufficient space around the display to ensure adequate ventilation.

  8. To ensure a safe installation, first check the structure of the wall, ceiling, or floor and select a secure mounting location.

  9. The wall, ceiling, or floor should be strong enough to sustain a weight of at least four times the display and mount combined. The mounting location must be able to withstand an earthquake or another strong shock.

  10. Do not modify any accessories or use broken parts. Contact your dealer with any questions.

  11. Tighten all screws (do not exert excessive force to avoid breaking the screw or damaging its thread).

  12. Drill holes and bolts will be left in the wall, ceiling, or floor once the display and bracket are removed. Stains may occur after extended use.

  13. Since the manufacturer has no way to control the wall, ceiling, or floor type and installation of the mount, the warranty of the product shall only cover the body of the mount. The warranty period of the product is 5 years.

  14. Please consult the English language manual for any dispute on conditions.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals