Installation instructions
Dear Customer
Congratulations on purchasing your new STEINEL sensor light and thank you for
the confidence you have shown in us. You have chosen a high-quality product
that has been manufactured, tested and packed with the greatest care.Please
familiarise yourself with these instructions before attempting to install the
sensor light because prolonged reliable and trouble-free operation will only
be ensured if it is fitted properly.
We hope your new STEINEL sensor light will bring you lasting pleasure.
Safety warnings
- Disconnect the mains power supply before attempting any work on the unit!
- During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first and use a voltage tester to make sure the wiring is off circuit.
- Installing the sensor light involves work on the mains voltage supply. This work must therefore be carried out professionally in accordance with applicable national wiring regulations and electrical operating conditions. (DE – VDE 0100, AT – ÖVE/ÖNORM E 8001-1, CH – SEV 1000)
Principle
The integrated infrared sensor is equipped with two 120° pyro sensors which detect the invisible heat emitted by moving objects (people, animals etc.).The heat detected is converted electronically into a signal that switches the light on automatically. Heat is not detected through obstacles, such as walls or panes of glass. Heat radiation of this type will, there-fore, not trigger the sensor. The two pyro sensors have an angle of coverage of 240° with an angle of aperture of 180°.Important: The most reliable way of detecting motion is to install the sensor light with the sensor aimed across the direction in which a person would walk and by ensuring that no obstacles (such as trees and walls, for example) obstruct the line of sensor vision.
Installation/wall mounting
The site of installation should be at least 50 cm away from another light
because heat radiated from it may activate the system. To achieve the
specified max. reach of 12 m, the light should be installed at a height of
approx. 2 m.
Connecting the mains supply lead (see illustration) The mains lead consists of
a 2-3 phase cable.
-
L = phase conductor (usually black or brown)
-
N = neutral conductor (usually blue)
-
PE = protective earth conductor (green/yellow)
If you are in any doubt, you must identify the cables using a voltage tester; now disconnect the power supply again. Connect phase (L), neutral (N) and protective earth (PE) to the terminals. -
Note on Fig. : For connection, the light arm must be clamped in the retaining bracket so as not to exert tension on the internal conductors.
-
Note on Fig. : The lampholder turns, permitting precision adjustment.
-
Note: A mains switch for switching the unit ON and OFF may of course be installed in the power supply lead. A mains switch is required for the manual override function (see Manual override function)
-
Note: for technical reasons, the LED lamp may flicker slightly to moderately at certain dimming levels. If this occurs, alter the dimming level slightly.
Technical specifications
Dimensions (H x W x D): 426 x Ø 102 x 177 mm
Power supply: 220-240 V/50 Hz
Power consumption (Pon): 9.2 W / E27
Luminous flux: 927 lm
Efficiency: 101 lm/W
Standby light: 0.9 W
Colour temperature: 3000 K (warm white)
Colour rendering index: Ra = 82
Average rated life expectancy: L70B50 at 25° C: > 20,000 hours.
Colour consistency SDCM: starting value: 3
Luminous intensity distribution:
150° 180° 150°
120° 120°
90° 90°
20
40
60° 60 60°
80
100
C0 /C180 30° 0° 30° C90 /C270
cd / 1000 lm
Angle of coverage: 240° with 180° angle of aperture
Detection reach: Max. 12 m
Twilight setting: 2-2000 lux
Time setting: 5 sec. – 15 min.
Manual override: Selectable (4 hrs.) / provided
switch is connected in mains power supply lead
IP rating: IP44
Protection class: I
Ambient temperature: – 20°C to + 40°C
Contains an energy efficiency class F light source
- For LED lamp provided with the light
Functions
The SensorLight can be put into service after mounting the sensor unit and connecting the light to the mains power supply.
- Switch-off delay (time setting) (factory setting: 5 sec.)
- Light ON duration can be infinitely varied from 5 sec. to 15 min.
- Control dial set to 1 = shortest time (5 sec.)
- Control dial set to 6 = longest time (15 min.)
- It is recommended to select the shortest time (setting 1) for adjusting the detection zone.
- Twilight setting (response threshold) (factory setting: daylight operation 2000 lux)
- The sensor’s response threshold can be infinitely varied from 2–2000 lux.
- Control dial set to 1 = daylight operation approx. 2000 lux.
- Control dial set to 6 = twilight operation approx.
- 2 lux.To adjust the detection zone in daylight, the control dial must be set to number 1 (daylight operation).
Manual override function
If a mains switch is installed in the mains supply lead, the light is capable
of the following functions in addition to the simple ON/OFF function:
Sensor operation
- Switch light ON (when light is OFF): Switch 1 x OFF and ON. Light stays on for the period selected.
- Switch light OFF (when light is ON): Switch 1 x OFF and ON. The light goes out or switches over to sensor mode.
Manual override
- Switch ON manual override: Switch ON and OFF twice. The light will stay ON for 4 hours (red LED lights up behind the lens). Then it returns automatically to sensor mode (red LED off).
- Deactivate manual override: Switch ON and OFF once. Light goes out or changes over to sensor mode.
Important:
The switch should be actuated in rapid succession (in the 0.5 – 1 sec. range).
Soft light start
The sensor light features a soft light start function. This means that when turned on, the light is not switched directly to maximum output but gradually builds up brightness to 100 % within the space of a second. Brightness is also gradually reduced when the light is switched OFF.
Reach setting/adjustment
At an assumed installation height of 2 m, the sensor has a maximum reach of 12
m. The detection zone can be optimised to suit needs. The shrouds provided are
used for blanking off any number of lens segments or to shorten reach as
required. This prevents the light from being activated unintentionally, e.g.
by cars, passers-by etc. and allows you to target danger spots. The shrouds
can be divided or cut with a pair of scissors along the vertical and
horizontal grooves. After removing the decorative ring, the shrouds can be
clipped on at the top of the sensor lens. The decorative ring must now be
pushed back on to hold the shrouds firmly in place.
Precision targeting can be achieved by turning the sensor housing through ±
80°
Operation/Maintenance
The sensor light is suitable for switching light on automatically. Weather conditions may affect the way the sensor light works. Strong gusts of wind, snow, rain or hail may cause the light to come on whenit is not wanted because the sensor is unable to distinguish suddAen changes of temperature from sources of heat. The detector lens may be cleaned with a damp cloth if it gets dirty (do not use cleaning agents).
Disposal
Electrical and electronic equipment, accessories and packaging must be
recycled in an environmentally compatible manner. Do not dispose of electrical
and electronic equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Electrical and Electronic
Equipment and its implementation in national law, electrical and electronic
equipment no longer suitable for use must be collect-ed separately and
recycled in an environmentally compatible manner.
Troubleshooting
Malfunction | Cause | Remedy |
---|---|---|
SensorLight without power | n Fuse faulty, not switched on, break in wiring |
n Short circuit
| n Fit new fuse, turn mains switch on; check wiring with
voltage tester
n Check connections
SensorLight will not switch ON| n Twilight control set to night-time mode during daytime operation
n LED lamp faulty n Mains switch OFF n Fuse faulty
n Detection zone not properly targeted
n Internal electrical fuse has been activated
(LED ON all the rime)
| n Re-adjust (control ®)
n Change n Switch on
n Fit new fuse, check connection
if necessary
n Re-adjust
n Switch OFF SensorLight or check/change lamp and switch back ON again after 5 sec
SensorLight will not switch OFF| n Continuous movement in the detection zone|
n Check detection zone and re-adjust if necessary
SensorLight switches on when it should not| n Wind is moving trees and bushes
in the detection zone
n Cars in the street are being detected
n Sudden temperature changes due to weather (wind, rain,
snow) or air expelled from fans, open windows
| n Change detection zone
n Change detection zone
n Change detection zone, change site of installation
SensorLight reach has changed| n Change in ambient temperatures| n Use shrouds
to adjust detection zone accurately
LED ON/flashes all the time although manual override is not selected| n
Internal fuse activated| n Switch OFF SensorLight or check/change lamp and
switch back ON again after 5 sec
LED lamp flickers| n For technical reasons, at various dimming levels| n Alter
dimming level
Manufacturer’s warranty
This STEINEL product has been manufactured with great care, tested for proper
operation and safety in accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-antees that it is in perfect
condition and proper work-ing order. The warranty period is 36 months,
starting on the date of sale to the consumer. We will remedy defects caused by
material flaws or manufacturing faults. The warranty will be met by repair or
replace-ment at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance.
Further consequential damage to other objects shall be excluded. The warranty
will only be honoured if the product is sent to the appropriate Service Centre
fully assembled and well packed with a brief description of the fault, receipt
or invoice (date of purchase and dealer’s stamp).
Repair Service:
Please ask your nearest service centre how to pro-ceed for repairing faults
not covered by the warranty or occurring after the warranty expires.