Tetel | Cikkszam | IFS megnevezes EN | Db |
---|---|---|---|
1 | ACM0734 | Spa Pump 3 HP – One Speed 60 Hz | 1 |
2 | ACM0956 | Control box IN.Yt-8 (4 kW) USA | 1 |
3 | ACM0951 | Circulation pump 60Hz 1100W (WBE150) | 1 |
4 | ACM0938 | UV+Ozone Spa Sanitizer-Aqua nova | 1 |
5 | ACM0955 | Countercurrent system 2400W 50Hz (WP300) | 3 |
6 | ABE0413 | Counterflow housing | 1 |
7 | ABE0409 | Suction 2″ with nut | 3 |
8 | AJ00214 | Jet 2″ – transparent 1 Hole transparent V3 Wellis | 6 |
9 | AJ00217 | Jet 3″ – transparent 1 Hole Rotation transparent V3 Wellis | 18 |
10 | ACM0875 | Grille for speaker 3″ (2 way) | 2 |
11 | AKU1896 | On-off tap grip Wellis V2 | 1 |
12 | AKU 1832 | Filter House – Skimmer Cover round | 2 |
13 | AKU 1842 | Skimmer house with Wellis logo | 2 |
14 | AKU 1895 | Air regulator grip Wellis V2 | 2 |
15 | AKU 1830 | Filter house for floating 50 sqffilters | 2 |
16 | AKU 1893 | On-Off tap house 33 transparent V2 | 1 |
17 | AKU 1892 | Air Regulator – house led lighted V2 | 2 |
18 | AKU2101 | Fountain laminar V2 | 6 |
19 | AE00594 | Self adjustment ring for suctions | 12 |
20 | ABE0409 | Suction 2″ with nut | 12 |
21 | AE00620 | Silicon gasket for suction 2″ | 12 |
22 | AKU2157 | Adapter for swim theater V2 | |
23 | AJ00254 | Jet house with sealing 3″ | 18 |
24 | AJ00257 | Sealing for Jet Housing 3″ | 18 |
25 | AJ00260 | Nut for Jet Housing 3″ | 18 |
26 | AJ00253 | Jet house 2″ with sealing V4 1/3 | 6 |
27 | AJ00169 | Jet – 20 SB – Ozone 90° | 1 |
28 | AKU2218 | Led housing with seal | 18 |
29 | AKU2219 | Nut for ledhouse | 18 |
30 | ACM0912 | Control Panel – IN.K1000 V2 | 1 |
31 | AJ00259 | Nozzle housing nut self-aligning 2″ V4 2/3 | 6 |
32 | AJ00256 | Washer for washer housing 2 “V4 3/3 | 6 |
Installation instruction
Residual-Current Device (RCD) having a rated operating residual-current not
exceeding 30 mA is must
The stated dimensions are for reference only. The actual dimension may be
different from the specified
L: Drain diameter: 50 mm
E: 3 m cable is required for the electrical connection through the spa
skirt.
Attention
The hot tube will be installed only if the electrical contractor makes
declaration of the installation of Residual-Current Device and proper fuses
Initial installation
The installation or making any repair are allowed only for properly skilled
person.
Disconnecting device has to be installed when the spa is directly connected to
the electricity networks.
-
Site preparation
a. Indoor / Basement installation
If you place your spa indoors, be aware of some special requirements: Water may accumulate around the spa, so the flooring material must have a proper runoff to avoid accumulation of water. When building a new room for the spa, constructing a floor drain is required, or damages may occur due to overflow, overfilling, or technical failure. Our company does not take responsibility for any damage in absence of floor drainage. Humidity will naturally increase in the room where the spa is located and the evaporated water condenses. For this reason ensure that the area has proper ventilation. We recommend installing a dehumidifier in the room.
b. Outdoor and patio installation
A solid horizontal foundation is necessary for installation of the spa. We advise using a reinforced concrete foundation at least 10-15cm thick. Ensure that your deck or foundation will support your spa. You must know the maximal load capacity of the foundation. Consult a qualified building contractor or structural engineer. To find out
the weight of your spa, its contents and occupants please refer to the spa specification chart. This weight must not exceed the structure’s rated capacity per square meter, otherwise serious structural damages could result. If you install the spa outdoors, we recommend a reinforced horizontal concrete pad at least 10-15cm thick.
Install floor drains around your spa to lead water away even in heavy rain. When constructing the water drain it is advised to form a 10-15cm deep sloping ditch around the spa which directs water to the drain. Water from the drain must be directed
to the canal or a drainage with enough capacity.
Warning: Do not expose the spa to direct sunlight (not even empty) without proper coverage. The insulated spa cover preserves the water temperature and provides protection from sunlight and rain. When exposed to sunshine for a longer period it
may damage the surface of the spa and the spa equipment. Acrylic rapidly absorbs heat from sun rays, thus reaches a very high surface temperature which may damage the spa. In case of sealed design, if the spa was placed between glass structures, prevent the sun rays from reaching the spa directly through the glass as the temperature may get too high.
c. In-Ground / Sunken Spa
In case of sinking the spa into the ground you must make sufficient space for walking around the spa. For completion of maintenance works a minimum of 60cm wide inspection pit must be built around the spa.
The inspection pit’s bottom must be under the bearing punt of the spa so that water can flow into the pit in case of water leakage. A floor drain or sump pump should be used at the bottom of the pit to ensure continual water drainage.
In case of sinking the spa only the portion below the spa’s acrylic edge can be sunk. The air of the inspection pit steams up. To prevent unpleasant odors proper ventilation must be provided (e.g. installing ventilators). The costs of pulling the spa out of the ground are borne by the user. If the aforementioned conditions are not present, setting up the spa may fail. -
Electrical connection
All the above stated electrical preparation must be ensured by the costumer. Every product has own connection drawing.
Use only copper wires. Change the fuses always with the same type. The device has to be connected to the equipotential grid.
You must
install a 30mA Residual-current device (RCD)
Product family: SwimLine
| Sheet name: Danube -2019 VFIow| Projection | Wellis
Magyar Orszag Zrt.
---|---|---|---
File name: FJ WU00030 ENG Danube-2019 W-Flow_ úszómedence
flow rate liter/min: 4480| Dimension SPA: 2350x4530x1470 mm| El. nds: 240 V –
62A – 60Hz
1 person ∼75 kg
Water disp.: 75 kg| Weight of the SPA: kg| | Control box: GECKO IN.YT-8 +
In.K1000 – 4KW
Rim height: 150 mm| Approved by: Losteiner Sandor| Pr. No:
P-00182
Fe. No:| Number: WU00030| D
Minimum water: 5913 liter| Created: 2020. 05. 15.| Drawer: losteiner. sandor –
2020. 05. 14.
14:51 37| A3| M 1:50