Wellis WU00030 Danube W-Flow Owner’s Manual

June 9, 2024
Wellis

Wellis logo WU00030 Danube W-Flow
Owner’s Manual

WU00030 Danube W-Flow

Wellis WU00030 Danube W Flow - Figure 1

Tetel Cikkszam IFS megnevezes EN Db
1 ACM0734 Spa Pump 3 HP – One Speed 60 Hz 1
2 ACM0956 Control box IN.Yt-8 (4 kW) USA 1
3 ACM0951 Circulation pump 60Hz 1100W (WBE150) 1
4 ACM0938 UV+Ozone Spa Sanitizer-Aqua nova 1
5 ACM0955 Countercurrent system 2400W 50Hz (WP300) 3
6 ABE0413 Counterflow housing 1
7 ABE0409 Suction 2″ with nut 3
8 AJ00214 Jet 2″ – transparent 1 Hole transparent V3 Wellis 6
9 AJ00217 Jet 3″ – transparent 1 Hole Rotation transparent V3 Wellis 18
10 ACM0875 Grille for speaker 3″ (2 way) 2
11 AKU1896 On-off tap grip Wellis V2 1
12 AKU 1832 Filter House – Skimmer Cover round 2
13 AKU 1842 Skimmer house with Wellis logo 2
14 AKU 1895 Air regulator grip Wellis V2 2
15 AKU 1830 Filter house for floating 50 sqffilters 2
16 AKU 1893 On-Off tap house 33 transparent V2 1
17 AKU 1892 Air Regulator – house led lighted V2 2
18 AKU2101 Fountain laminar V2 6
19 AE00594 Self adjustment ring for suctions 12
20 ABE0409 Suction 2″ with nut 12
21 AE00620 Silicon gasket for suction 2″ 12
22 AKU2157 Adapter for swim theater V2
23 AJ00254 Jet house with sealing 3″ 18
24 AJ00257 Sealing for Jet Housing 3″ 18
25 AJ00260 Nut for Jet Housing 3″ 18
26 AJ00253 Jet house 2″ with sealing V4 1/3 6
27 AJ00169 Jet – 20 SB – Ozone 90° 1
28 AKU2218 Led housing with seal 18
29 AKU2219 Nut for ledhouse 18
30 ACM0912 Control Panel – IN.K1000 V2 1
31 AJ00259 Nozzle housing nut self-aligning 2″ V4 2/3 6
32 AJ00256 Washer for washer housing 2 “V4 3/3 6

Installation instruction

Residual-Current Device (RCD) having a rated operating residual-current not exceeding 30 mA is must
The stated dimensions are for reference only. The actual dimension may be different from the specified
L: Drain diameter: 50 mm
E: 3 m cable is required for the electrical connection through the spa skirt.
Attention
The hot tube will be installed only if the electrical contractor makes declaration of the installation of Residual-Current Device and proper fuses
Initial installation
The installation or making any repair are allowed only for properly skilled person.
Disconnecting device has to be installed when the spa is directly connected to the electricity networks.

  1. Site preparation
    a. Indoor / Basement installation
    If you place your spa indoors, be aware of some special requirements: Water may accumulate around the spa, so the flooring material must have a proper runoff to avoid accumulation of water. When building a new room for the spa, constructing a floor drain is required, or damages may occur due to overflow, overfilling, or technical failure. Our company does not take responsibility for any damage in absence of floor drainage. Humidity will naturally increase in the room where the spa is located and the evaporated water condenses. For this reason ensure that the area has proper ventilation. We recommend installing a dehumidifier in the room.
    b. Outdoor and patio installation
    Wellis WU00030 Danube W Flow - Figure 2
    A solid horizontal foundation is necessary for installation of the spa. We advise using a reinforced concrete foundation at least 10-15cm thick. Ensure that your deck or foundation will support your spa. You must know the maximal load capacity of the foundation. Consult a qualified building contractor or structural engineer. To find out
    the weight of your spa, its contents and occupants please refer to the spa specification chart. This weight must not exceed the structure’s rated capacity per square meter, otherwise serious structural damages could result. If you install the spa outdoors, we recommend a reinforced horizontal concrete pad at least 10-15cm thick.
    Install floor drains around your spa to lead water away even in heavy rain. When constructing the water drain it is advised to form a 10-15cm deep sloping ditch around the spa which directs water to the drain. Water from the drain must be directed
    to the canal or a drainage with enough capacity.
    Warning: Do not expose the spa to direct sunlight (not even empty) without proper coverage. The insulated spa cover preserves the water temperature and provides protection from sunlight and rain. When exposed to sunshine for a longer period it
    may damage the surface of the spa and the spa equipment. Acrylic rapidly absorbs heat from sun rays, thus reaches a very high surface temperature which may damage the spa. In case of sealed design, if the spa was placed between glass structures, prevent the sun rays from reaching the spa directly through the glass as the temperature may get too high.
    c. In-Ground / Sunken Spa
    In case of sinking the spa into the ground you must make sufficient space for walking around the spa. For completion of maintenance works a minimum of 60cm wide inspection pit must be built around the spa.
    The inspection pit’s bottom must be under the bearing punt of the spa so that water can flow into the pit in case of water leakage. A floor drain or sump pump should be used at the bottom of the pit to ensure continual water drainage.
    In case of sinking the spa only the portion below the spa’s acrylic edge can be sunk. The air of the inspection pit steams up. To prevent unpleasant odors proper ventilation must be provided (e.g. installing ventilators). The costs of pulling the spa out of the ground are borne by the user. If the aforementioned conditions are not present, setting up the spa may fail.

  2. Electrical connection
    All the above stated electrical preparation must be ensured by the costumer. Every product has own connection drawing.
    Use only copper wires. Change the fuses always with the same type. The device has to be connected to the equipotential grid.

Wellis WU00030 Danube W Flow - Figure 3You must install a 30mA Residual-current device (RCD)
Product family: SwimLine

| Sheet name: Danube -2019 VFIow| Projection | Wellis
logoWellis Magyar Orszag Zrt.
---|---|---|---
File name: FJ WU00030 ENG Danube-2019 W-Flow_ úszómedence
flow rate liter/min: 4480| Dimension SPA: 2350x4530x1470 mm| El. nds: 240 V – 62A – 60Hz
1 person ∼75 kg
Water disp.: 75 kg| Weight of the SPA: kg| | Control box: GECKO IN.YT-8 + In.K1000 – 4KW
Rim height: 150 mm| Approved by: Losteiner Sandor| Pr. No:
P-00182
Fe. No:| Number: WU00030| D
Minimum water: 5913 liter| Created: 2020. 05. 15.| Drawer: losteiner. sandor – 2020. 05. 14.
14:51 37| A3| M 1:50

Wellis logo