ZALMAN ARX Series High Efficiency Switching Power Supply User Manual
- June 5, 2024
- ZALMAN
Table of Contents
ARX Series High-Efficiency Switching Power Supply
User Manual
To ensure safe and easy installation, Please read the following precautions.
www.ZALMAN.com
Warnings and Safety Precautions
Warning
Neglecting the following may cause serious injury or death.
- Opening the product’s cover while the power cord is plugged into an outlet may cause electrocution or critical damage to the product.
- Handling the power cord with wet hands may cause electrocution.
- Inserting fingers or metallic objects into the cooling fan may cause injury or electrocution.
Caution
Neglecting the following may cause minor injuries, degrade product
conditions or cause malfunction.
- Operating the product in an extremely cold or hot environment can degrade product performance and lifespan.
- Exposure to liquids may cause malfunction.
- Operation in a humid or non-ventilated environment may reduce product lifespan.
- Plugging the primary power connector P1 into the motherboard while the product is connected to the AC power source may cause damage to the motherboard.
- Make sure that the connectors are connected to their designated locations, and that the connectors are not oriented in the wrong direction when connecting the DC output connectors.
- Please use gloves to prevent injuries during installation.
- Product designs and specifications may be revised without prior notification to improve quality and performance.
Disclaimer) Zalman Tech Co., Ltd. is not responsible for any damages due to external causes, including but not limited to, improper use, problems with electrical power, accident, neglect, alteration, repair, improper installation, or improper testing.
Components
Specifications
ZM750-ARX Electrical & Physical Specifications
AC Input Range| Voltage| I 100-240VAC ±10%| Vout| Output Load Rating| Combined
Power
---|---|---|---|---|---
Frequency| 50Hz – 60Hz ±3| Iman| ‘max| ‘peak
AC Input Current| 100VAC| 10-5A
_| +3.3V| 0.1A| 25A| | 120W| 750W
240VAC| +5V| 0.2A| 22A|
PFC Type| Active PFC| +12V| 0.2A| 62A| | 744W
Power Factor Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current Limit
(@ Cold Start at 25°C)| 100VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
240VAC| Ambient Temperature
Efficiency| Max 94% @ 230VAC, Typical load| Operation| 0 – +40°C
DC Output Voltage
Regulation| Vout| Regulation Range| At
Full
Load| Storage| -20 – +70°C
+3.3VDC| ±5%| +3.14 – +3.47V| Ambient Humidity
+5VDC| ±5%| +4.75 – +5.25V| Operation| 5% – 95% RH
+12VDC| ±5%| +11.4 – +12.6V| Storage| 5% – 95% RH
-12VDC| ±10%| -10.8 – -13.0V| Dimensions| 180(D) x 150(W) x 86(H)mm
+5VSB| ±5%| +4.75 – +5.25V| Weight| 2.9kg
DC Output Ripple
& Noise| Vout| Standard Range| At
Full
Load| Protection Functions
+3.3VDC| 50mV| Over-Current Protection (OCP)
+5VDC| 50mV| Over-Voltage Protection (OVP)
+12VDC| 120mV| Under-Voltage Protection (UVP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+5VSB| 50mV| Over-Power Protection (OPP)
| Over-Temperature Protection (OTP)
ZM850-ARX Electrical & Physical Specifications
AC Input Range| Voltage| I 100-240VAC ±10%| Vout| Output Load Rating| Combined
Power
---|---|---|---|---|---
Frequency| 50Hz – 60Hz ±3| Imin| ‘max| ‘peak
AC Input Current| 100VAC| 11-5.5A| +3.3V| 0.1A| 25A| | 120W| 850W
240VAC| +5V| 0.2A| 22A|
PFC Type| Active PFC| +12V| 0.2A| 70A| | 840W
Power Factor Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current Limit
(@ Cold Start at 25°C)| 100VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
240VAC| Ambient Temperature
Efficiency| Max 94% @ 230VAC, Typical load| Operation| 0 – +40°C
DC Output Voltage
Regulation| Vout| Regulation Range| At
Full
Load| Storage| -20 – +70°C
+3.3VDC| ±5%| +3.14 – +3.47V| Ambient Humidity
+5VDC| ±5%| +4.75 – +5.25V| Operation| 5% – 95% RH
+12VDC| ±5%| +11.4 – +12.6V| Storage| 5% – 95% RH
-12VDC| ±10%| -10.8 – -13.0V| Dimensions| 180(D) x 150(W) x 86(H)mm
+5VSB| ±5%| _ +4.75 – +5.25V| Weight| 2.95kg
DC Output Ripple
& Noise| Vout| Standard Range| At
Full
Load| Protection Functions
+3.3VDC| 50mV| Over-Current Protection (OCP)
+5VDC| 50mV| Over-Voltage Protection (OVP)
+12VDC| 120mV| Under-Voltage Protection (UVP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+5VSB| 50mV| Over-Power Protection (OPP)
| Over-Temperature Protection (OTP)
ZM1000-ARX Electrical & Physical Specifications
AC Input Range| Voltage| I 100-240VAC ±10%| Vout| Output Load Rating| Combined
Power
---|---|---|---|---|---
Frequency| 50Hz – 60Hz ±3| 1mm| ‘max| ‘peak
AC Input Current| 100VAC| 12-6A
_| +3.3V| 0.1A| 25A| | 120W| 1000W
240VAC| +5V| 0.2A| 22A|
PFC Type| Active PFC| +12V| 0.2A| 83A| | 996W
Power Factor Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current Limit
(@ Cold Start at 25°C)| 100VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
240VAC| Ambient Temperature
Efficiency| Max 94% @ 230VAC, Typical load| Operation| 0 – +40’C
DC Output Voltage
Regulation| Vout| Regulation Range| At
Full
Load| Storage| -20 – +70`C
+3.3VDC| ±5%| +3.14 – +3.47V| Ambient Humidity
+5VDC| ±5%| +4.75 – +5.25V| Operation| 5% – 95% RH
+12VDC| ±5%| +11.4 – +12.6V| Storage| 5% – 95% RH
-12VDC| ±10%| -10.8 – -13.0V| Dimensions| 180(D) x 150(W) x 86(H)mm
+5VSB| ±5%| +4.75 – +5.25V| Weight| 3.05kg
DC Output Ripple
& Noise| Vout| Standard Range| At
Full
Load| Protection Functions
+3.3VDC| 50mV| Over-Current Protection (OCP)
+5VDC| 50mV| Over-Voltage Protection (OVP)
+12VDC| 120mV| Under-Voltage Protection (UVP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+5VSB| 50mV| Over-Power Protection (OPP)
| Over-Temperature Protection (OTP)
ZM1200-ARX Electrical & Physical Specifications
AC Input Range| Voltage| I 115-240VAC ±10%| Vout| Output Load Rating| Combined
Power
---|---|---|---|---|---
Frequency| 50Hz – 60Hz ±3| Imin| I
x| (peak
AC Input Current| 115VAC| 12.6-6A(EU) /
12-6A(North America)| +3.3V| 0.1A| 25A| | 120W| 1200W
240VAC| +5V| 0.2A| 22A|
PFC Type| Active PFC| +12V| 0.2A| 100A| | 1200W
Power Factor Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current Limit
(@ Cold Start at 25°C)| 115VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
240VAC| Ambient Temperature
Efficiency| Max 94% @ 230VAC, Typical load| The operation I 0 – +40°C
DC Output Voltage
Regulation| Vout| Regulation Range| At
Full
Load| Storage I -20 — +70°C
+3.3VDC| ±5%| +3.14 – +3.47V| Ambient Humidity
+5VDC| ±5%| +4.75 – +5.25V| Operation| 5% — 95% RH
+12VDC| ±5%| +11.4 – +12.6V| Storage| 5% – 95% RH
-12VDC| ±10%| -10.8 – -13.0V| Dimensions| 180(D) x 150(W) x 86(H)mm
+5VSB| ±5%| +4.75 – +5.25V| Weight| 3.1kg
DC Output Ripple
& Noise| Vout| Standard Range| At
Full
Load| Protection Functions
+3.3VDC| 50mV| Over-Current Protection (OCP)
+5VDC| 50mV| Over-Voltage Protection (OVP)
+12VDC| 120mV| Under-Voltage Protection (UVP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+5VSB| 50mV| Over-Power Protection (OPP)
| Over-Temperature Protection (OTP)
ARX-Series Cable & Connector Specifications
Connector
Model| Main Board
(20+4Pin)| ATX12V
(4+4Pin)| EPS12V
(8Pin)| PEI-Ex
(6+2Pin)| SANTA
(SPin)| Peripheral
(4Pin)| FDD
**(4Pin)**
---|---|---|---|---|---|---|---
ZM750-ARX| 1| 1| 1| 4| 12| 6| 1
600mm| 700mm| 650mm| 550mmx 4
ZM850-ARX| 1| 1| 1| 6| 12| 8| 1
600mm| 700mm| 650mm| 550mm x
ZM1000-ARX| 1| 1| 1| 6| 12| 8| 1
600mm| 700mm| 650mm| 550mm x
ZM1200-ARX| 1| 1| 1| I 8| 16| 8| 1
600mm| 700mm| 650mm| 550mm x 4
(550mm +150mm) x 2
Certifications
Warranty Information
Zalman Tech products come with the following limited warranties:
-
One Year Warranty
CPU coolers (All CNPS series, Reserator 3 Max series, LQ3xx series), computer cases, keyboards, mice, laptop coolers, case fans, hardware enclosures (including VE series),
audio devices, and all other accessories not specified below. -
Three Years Warranty
HQ series AIO CPU coolers -
Seven Years Warranty
EBT series Power Supply Units, ARX series Power Supply Units
Zalman USA has the right to change the availability of a limited warranty at its own discretion and any changes will not be retroactive. -
The limited warranty does not cover…
1. Non-Zalman brand products and accessories.
2. Problems resulting from external causes such as accidents, abuse, misuse, and/or problems with electrical power.
3. Any service not authorized by Zalman USA.
4. Usage that is not in accordance with product instructions.
5. Failure to follow the product instructions and/or failure to perform preventive maintenance.
6. Problems caused by using accessories, parts, and/or components not supplied by Zalman.
7. Products with missing, altered Service Tags and/or serial numbers. -
For the United States and Canada
Technical support and warranty-related inquiries: support.usa@zalmanusa.com Toll-free customer service: 1-888-925-6266 -
For all other regions
Send e-mail to techsupport@zalman.co.kr
For detailed warranty information, please visit www.zalman.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>