pumpables 210618 SuperGenie Hospital Grade Breast Pump User Guide

June 5, 2024
pumpables

pumpable 210618 SuperGenie Hospital Grade Breast Pump

pumpables 210618 SuperGenie Hospital Grade Breast Pump
PRODUCT

Welcome to Pumpables
Congratulations on becoming the owner of a Pumpables breast pump! We are so happy to welcome you to the Pumpables family.

If you’re in a hurry
If you’ve used a breast pump before, or you’re in a hurry then feel free to go straight to the Getting started’ section within this manual. This contains basic information on prepping your pump and accessories for use and operating the pump.

If you’re new to breast pumps or ready to learn more
We really encourage you to check out the full manual to get lots more information. We’ve included information on suggested pump routines, replacing parts and lots more to give you a good grounding in using your breast pump.

Check for updates
We release new features, make improvements and update manuals all the time! To make sure you have the latest version, go to pumpable.co/manuals

Getting help
Working out using a breast pump and breastfeeding while you care for a newborn is hard work and you don’t need to do it alone.
You are very welcome as part of the Pumpables community. If you need help, please get in touch.
Email
[email protected] fb.com/pumpables
Need help or have a question? Send us an email and we will get right back.

Facebook chat
Find us on Facebook and send us a message. Easiest method for busy mamas!

Community
Fitting room pumpable.co/sitting room pumpable.co/community Get support, tips and feed- back from other mamas in Pumpables Community on Facebook.

Fitting room
Get a second opinion on your shield fit & positioning from the Pumpables team.

Issues with your pump
If you suspect a fault or something isn’t right, email our customer service at [email protected] or fill out the claim form at pumpable.co/warranty. We prioritize warranty support and we will get back to you straight away

What’s in the bOx

pumpables 210618 SuperGenie Hospital Grade Breast Pump
FIG 1

We’ll guide you through getting to know your SuperGenie later in this manual, but for now, here’s a list of everything that’s included with your pump.

  • We’re always releasing updates. Go to pumpables.co/manuals for the latest version of the manual.
  • This full manual also tells you all the tips and trick for your Liquid Kit.

Intended use & safety

SuperGenie Double Electric Breast Pump with Liquid Pumping System is a hospital grade breast pump to help lactating women express and collect milk.

  • The SuperGenie is a closed system breast pump. Your milk collection kit should not be shared between users.
  • Clean and sanitize all parts that come in contact with your breast and breastmilk prior to first use. Wash all parts that come in contact vwith your breast and breast milk after every use.
  • Inspect all appropriate pump components before each use If tube becomes mouldy, discontinue use and replace tube. If breast milk backup occurs, clean the tube before your next pumping session.
  • DO NOT use antibacterial or abrasive cleaners/detergents when cleaning breast pump or breast pump parts. Never put breast pump motor in water or sterilizer, as permanent damage can be caused to the device.
  • DO NOT attempt to remove the breast shield from your breast while pumping. Turn the breast pump off and break the seal between your breast and breast shield with your finger, then remove the breast shield from your breast.
  • If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the breast and the breast shield with your finger and remove breast shield from your breast.
  • Plastic bottles and component parts become brittle when frozen and may break when dropped. lake appropriate care in handling bottles and components.
  • The power adapter is a part of the breast pump. Please always check the power adapter before use and if damage is found, discontinue use. Make sure the voitage of the power adapter is compatible with the power source. Plug the power adapter into the breast pump first, then into the power Source.
  • Do not use outdoors or operate where aerosol products are being used, or where oxygen is being administered
  • Do not use while bathing, or place device where it can be submerged in water. lf the device falls into water, do not reach for it and immediately disconnect from electrical outiet.
  • Do not leave device unattended when plugged into an electrical outlet. Do not position the breast pump such that it is difficult to disconnect the adapter plug from the main power supply.
  • Close supervision is necessary when used near children or people with disabilities.
  • Do not use attachments not recommended by the manufacturer.
  • Keep cord away from heated surface. Never drop or insert objects into any openin9 tubes.
  • Use product only for its intended use.

Get to know yOur SuperGenie

pumpables 210618 SuperGenie Hospital Grade
Breast Pump FIG 4

Meet your new SuperGenie breast pump, the most advanced desktop breast pump available today. The SuperGenie provides hospital grade performance with integrated smart features.

Get to know your Liquid Kit

Getting to know the parts of your Liquid Kit will help you get the most out of them. It can be confusing the first time you assemble the kit, so let us know if you need help.pumpables 210618 SuperGenie Hospital Grade Breast Pump FIG
5

Getting started
Sterilizing your accessories before first usepumpables 210618 SuperGenie
Hospital Grade Breast Pump FIG 6

Sterilize everything on left. You can sterilise the bottle stand an shield cover if you like but iť’s not necessary. Never sterilise or immerse tubing or seal cap You can use any sterilising method that you prefer. Here are
instructions for sterilising using the boiling method:pumpables 210618
SuperGenie Hospital Grade Breast Pump FIG 7

  1. Choose a bia not
    Make sure the pot you choose is large so accessories don’t ‘bump’ into each other.
    Parts can warp if they bump into each other during sterilising.pumpables
210618 SuperGenie Hospital Grade Breast Pump FIG 8

  2. Place in accessories

  3. Bring to boil, then boil for b minutespumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 10

  4. Air dry on a clean surtace

**Charging your pump

pumpables 210618 SuperGenie Hospital Grade Breast
Pump FIG 11**

  • YOu can start using your pump rignt  out of the box. Once it’s time to recharge, charging time is 4 hours.
  • You Can use the pump while charging awaypumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 12
  • When assembling the adaptor, make sure it clicks into place
  • Plug into pumppumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 13
  • Lighting icon will blink during charging
  • Lighting icon will stop blinking when
    fully charged

Assembling your Liquid Kit

pumpables 210618 SuperGenie Hospital Grade
Breast Pump FIG 14

  • Slide the Liquid insert inside the shield assembly and ensure it is attached firmly Make sure the valve is secure.
  • Ensure insert is flush with shield. Place seal diaphragm on the shield assembly. Iip
    • use your finger to ensure the edge is flush. This is important so the kit is airtight
  • Attach your seal cap & then use your tubing to connect your accessory kit to the pump motor. Don’t forget to cover the unused air port if you’ re single pumping!

Connecting the app

Download the SuperGenie app to control your SuperGenie, track sessions and save programs.

The SuperGenie pump app can be downloaded through the App Store or Google Play. Once you have downloaded the app, please follow the instructions to connect your SuperGenie and get set up. You’ll need to enable location access so that the app can use a lower energy bluetooth setting. If you need help, just let us know.

Understanding the Controlspumpables 210618 SuperGenie Hospital Grade
Breast Pump FIG 19

Start SuperGenie
Press power button () for 2 seconds to turn on SuperGenie

  • Bluetooth pairing
  • SuperGenie is connected
  • Switch between modes
  • Change between letdown and expression mode by pressing mode buttonpumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 20

Letdown mode

  • Vacuum strength: 1-5
  • Cycle speed: 72-104

Expression mode

  • Vacuum strength: 1-16
  • Cycle speed: 40-70

Stop and resume
Press the power button () shortly to pause/start pumping againpumpables
210618 SuperGenie Hospital Grade Breast Pump FIG 21

The mode icon blinks when pumping stops

Adjust settings
Adjust settings with the vacuum and cycle buttonpumpables 210618 SuperGenie
Hospital Grade Breast Pump FIG 22

Turn off SuperGenie
The press the power button for 2 seconds to turn off SuperGeniepumpables
210618 SuperGenie Hospital Grade Breast Pump FIG 23

Create your own program

pumpables 210618 SuperGenie Hospital Grade
Breast Pump FIG 24

  1. Press the record / OK button
  2. When “Record Icon” appears blinking, adjust the vacuum and cyclepumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 26
  3. Finish recording by pressing record / OK button
  4. Select the program to save by pressing the program buttonpumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 26
  5. Confirm Save by pressing the record / OK button
  6. The saved program is displayed on the screen. You cannot erase programs. To overwrite a program, select P1 or P2 again after recording a new program.

Start your programpumpables 210618 SuperGenie Hospital Grade Breast Pump
FIG 27

  1. Press program button
  2. Choose program by pressing the program buttonpumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 28
  3. Select program by pressing record / OK button
  4. Program starts

Getting started with settings
Every woman is different, so trying out the different settings is really worth it – but here is a program to get you started:

On the pumppumpables 210618 SuperGenie Hospital Grade Breast Pump FIG
29

  1. Attach the Liquid kit to your breast
  2. Turn the pump onpumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 30
  3. Put the pump in letdown mode
  4. Increase cycle speed to 104pumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 31
  5. Increase vacuum to level two and adjust to comfort level
  6. Once milk flow starts or after two minutes, switch to expression modepumpables 210618 SuperGenie Hospital Grade Breast Pump FIG 32
  7. Set cycle speed to 70
    4. Set vacuum level to 6 and adjust to comfort level

Once the milk flow slows down, try going back to letdown mode, and repeating this program.
Have you downloaded the Pumpables app yet? You can control your SuperGenie Gen2 from your phone, create programs, track milk output, change default settings, update your pump, and more!

Replacing parts

Some parts of your kit need replacing regularly, depending on how often you pump. This is important! Worn out parts are the most Common reason for a decrease in output. Here’s an overvieW of what to replace when:pumpables
210618 SuperGenie Hospital Grade Breast Pump FIG 33

Technical specifications

pumpables 210618 SuperGenie Hospital Grade
Breast Pump FIG 35

Warranty
This product is warranted by Pumpables to be free from defects in material and manufacturing for a period of two years from the date of purchase. This warranty does not cover damage caused by accident, misuse, abuse, improper
maintenance, unauthorized modification, or connection to an improper power supply. I he warranty does not cover wear and tear caused by the regular use of this product. Issues or defects should be reported to Pumpables as soon as possible after discovery. Pumpables reserves the right to investigate the issue or defect before taking any remedy. In the event of defect, at Pumpables’ option, Pumpables will replace the product free of charge or arrange repair. All efforts will be made to reduce inconvenience to the user. Where possible, arrangements will be made for the return of faulty / defective products to Pumpables to improve quality control and aid product improvement. If you need assistance with correct usage, care or warraty when using this product, please contact us at [email protected]