pumpables 210618 SuperGenie Hospital Grade Breast Pump User Guide
- June 5, 2024
- pumpables
Table of Contents
- pumpable 210618 SuperGenie Hospital Grade Breast Pump
- What’s in the bOx
- Intended use & safety
- Get to know yOur SuperGenie
- Get to know your Liquid Kit
- **Charging your pump
- Assembling your Liquid Kit
- Connecting the app
- Create your own program
- Replacing parts
- Technical specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
pumpable 210618 SuperGenie Hospital Grade Breast Pump
Welcome to Pumpables
Congratulations on becoming the owner of a Pumpables breast pump! We are so
happy to welcome you to the Pumpables family.
If you’re in a hurry
If you’ve used a breast pump before, or you’re in a hurry then feel free to go
straight to the Getting started’ section within this manual. This contains
basic information on prepping your pump and accessories for use and operating
the pump.
If you’re new to breast pumps or ready to learn more
We really encourage you to check out the full manual to get lots more
information. We’ve included information on suggested pump routines, replacing
parts and lots more to give you a good grounding in using your breast pump.
Check for updates
We release new features, make improvements and update manuals all the time! To
make sure you have the latest version, go to pumpable.co/manuals
Getting help
Working out using a breast pump and breastfeeding while you care for a newborn
is hard work and you don’t need to do it alone.
You are very welcome as part of the Pumpables community. If you need help,
please get in touch.
Email
[email protected] fb.com/pumpables
Need help or have a question? Send us an email and we will get right back.
Facebook chat
Find us on Facebook and send us a message. Easiest method for busy mamas!
Community
Fitting room pumpable.co/sitting room pumpable.co/community Get support, tips
and feed- back from other mamas in Pumpables Community on Facebook.
Fitting room
Get a second opinion on your shield fit & positioning from the Pumpables team.
Issues with your pump
If you suspect a fault or something isn’t right, email our customer service at
[email protected] or fill out the claim form at
pumpable.co/warranty. We prioritize warranty
support and we will get back to you straight away
What’s in the bOx
We’ll guide you through getting to know your SuperGenie later in this manual, but for now, here’s a list of everything that’s included with your pump.
- We’re always releasing updates. Go to pumpables.co/manuals for the latest version of the manual.
- This full manual also tells you all the tips and trick for your Liquid Kit.
Intended use & safety
SuperGenie Double Electric Breast Pump with Liquid Pumping System is a hospital grade breast pump to help lactating women express and collect milk.
- The SuperGenie is a closed system breast pump. Your milk collection kit should not be shared between users.
- Clean and sanitize all parts that come in contact with your breast and breastmilk prior to first use. Wash all parts that come in contact vwith your breast and breast milk after every use.
- Inspect all appropriate pump components before each use If tube becomes mouldy, discontinue use and replace tube. If breast milk backup occurs, clean the tube before your next pumping session.
- DO NOT use antibacterial or abrasive cleaners/detergents when cleaning breast pump or breast pump parts. Never put breast pump motor in water or sterilizer, as permanent damage can be caused to the device.
- DO NOT attempt to remove the breast shield from your breast while pumping. Turn the breast pump off and break the seal between your breast and breast shield with your finger, then remove the breast shield from your breast.
- If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the breast and the breast shield with your finger and remove breast shield from your breast.
- Plastic bottles and component parts become brittle when frozen and may break when dropped. lake appropriate care in handling bottles and components.
- The power adapter is a part of the breast pump. Please always check the power adapter before use and if damage is found, discontinue use. Make sure the voitage of the power adapter is compatible with the power source. Plug the power adapter into the breast pump first, then into the power Source.
- Do not use outdoors or operate where aerosol products are being used, or where oxygen is being administered
- Do not use while bathing, or place device where it can be submerged in water. lf the device falls into water, do not reach for it and immediately disconnect from electrical outiet.
- Do not leave device unattended when plugged into an electrical outlet. Do not position the breast pump such that it is difficult to disconnect the adapter plug from the main power supply.
- Close supervision is necessary when used near children or people with disabilities.
- Do not use attachments not recommended by the manufacturer.
- Keep cord away from heated surface. Never drop or insert objects into any openin9 tubes.
- Use product only for its intended use.
Get to know yOur SuperGenie
Meet your new SuperGenie breast pump, the most advanced desktop breast pump available today. The SuperGenie provides hospital grade performance with integrated smart features.
Get to know your Liquid Kit
Getting to know the parts of your Liquid Kit will help you get the most out of
them. It can be confusing the first time you assemble the kit, so let us know
if you need help.
Getting started
Sterilizing your accessories before first use
Sterilize everything on left. You can sterilise the bottle stand an shield
cover if you like but iť’s not necessary. Never sterilise or immerse tubing or
seal cap You can use any sterilising method that you prefer. Here are
instructions for sterilising using the boiling method:
-
Choose a bia not
Make sure the pot you choose is large so accessories don’t ‘bump’ into each other.
Parts can warp if they bump into each other during sterilising. -
Place in accessories
-
Bring to boil, then boil for b minutes
-
Air dry on a clean surtace
**Charging your pump
**
- YOu can start using your pump rignt out of the box. Once it’s time to recharge, charging time is 4 hours.
- You Can use the pump while charging away
- When assembling the adaptor, make sure it clicks into place
- Plug into pump
- Lighting icon will blink during charging
- Lighting icon will stop blinking when
fully charged
Assembling your Liquid Kit
- Slide the Liquid insert inside the shield assembly and ensure it is attached firmly Make sure the valve is secure.
- Ensure insert is flush with shield. Place seal diaphragm on the shield assembly. Iip
- use your finger to ensure the edge is flush. This is important so the kit is airtight
- Attach your seal cap & then use your tubing to connect your accessory kit to the pump motor. Don’t forget to cover the unused air port if you’ re single pumping!
Connecting the app
Download the SuperGenie app to control your SuperGenie, track sessions and save programs.
The SuperGenie pump app can be downloaded through the App Store or Google Play. Once you have downloaded the app, please follow the instructions to connect your SuperGenie and get set up. You’ll need to enable location access so that the app can use a lower energy bluetooth setting. If you need help, just let us know.
Understanding the Controls
Start SuperGenie
Press power button () for 2 seconds to turn on SuperGenie
- Bluetooth pairing
- SuperGenie is connected
- Switch between modes
- Change between letdown and expression mode by pressing mode button
Letdown mode
- Vacuum strength: 1-5
- Cycle speed: 72-104
Expression mode
- Vacuum strength: 1-16
- Cycle speed: 40-70
Stop and resume
Press the power button () shortly to pause/start pumping again
The mode icon blinks when pumping stops
Adjust settings
Adjust settings with the vacuum and cycle button
Turn off SuperGenie
The press the power button for 2 seconds to turn off SuperGenie
Create your own program
- Press the record / OK button
- When “Record Icon” appears blinking, adjust the vacuum and cycle
- Finish recording by pressing record / OK button
- Select the program to save by pressing the program button
- Confirm Save by pressing the record / OK button
- The saved program is displayed on the screen. You cannot erase programs. To overwrite a program, select P1 or P2 again after recording a new program.
Start your program
- Press program button
- Choose program by pressing the program button
- Select program by pressing record / OK button
- Program starts
Getting started with settings
Every woman is different, so trying out the different settings is really
worth it – but here is a program to get you started:
On the pump
- Attach the Liquid kit to your breast
- Turn the pump on
- Put the pump in letdown mode
- Increase cycle speed to 104
- Increase vacuum to level two and adjust to comfort level
- Once milk flow starts or after two minutes, switch to expression mode
- Set cycle speed to 70
4. Set vacuum level to 6 and adjust to comfort level
Once the milk flow slows down, try going back to letdown mode, and repeating
this program.
Have you downloaded the Pumpables app yet? You can control your SuperGenie
Gen2 from your phone, create programs, track milk output, change default
settings, update your pump, and more!
Replacing parts
Some parts of your kit need replacing regularly, depending on how often you
pump. This is important! Worn out parts are the most Common reason for a
decrease in output. Here’s an overvieW of what to replace when:
Technical specifications
Warranty
This product is warranted by Pumpables to be free from defects in material and
manufacturing for a period of two years from the date of purchase. This
warranty does not cover damage caused by accident, misuse, abuse, improper
maintenance, unauthorized modification, or connection to an improper power
supply. I he warranty does not cover wear and tear caused by the regular use
of this product. Issues or defects should be reported to Pumpables as soon as
possible after discovery. Pumpables reserves the right to investigate the
issue or defect before taking any remedy. In the event of defect, at
Pumpables’ option, Pumpables will replace the product free of charge or
arrange repair. All efforts will be made to reduce inconvenience to the user.
Where possible, arrangements will be made for the return of faulty / defective
products to Pumpables to improve quality control and aid product improvement.
If you need assistance with correct usage, care or warraty when using this
product, please contact us at [email protected]
References
- Log into Facebook | Facebook
- Log into Facebook | Facebook
- Fitting Room – Pumpables
- Pumpables Manuals & Guides
- Warranty – Pumpables