milwaukee M18 HSAL LED Stand Light Charger Instruction Manual

June 3, 2024
Milwaukee

milwaukee M18 HSAL LED Stand Light Charger

milwaukee M18 HSAL LED Stand Light Charger

Operating description and Functional description

milwaukee M18 HSAL LED Stand Light Charger 1

Remove the battery pack before starting any work on the machine.

milwaukee M18 HSAL LED Stand Light Charger 2

CHARGING DETAILS

  • Continuous red: Charging
  • Continuous green: Charging is complete
  • Flashing red: Battery is too hot/cold
  • Flashing red/green: Damaged or faulty battery packmilwaukee M18 HSAL LED Stand Light Charger 3

milwaukee M18 HSAL LED Stand Light Charger 4 milwaukee M18 HSAL LED Stand Light Charger 5 milwaukee M18 HSAL LED Stand Light Charger 6

If the light is plugged into a AC outlet, the light runs in AC mode. Currently the battery will be charged.

milwaukee M18 HSAL LED Stand Light Charger 7

TECHNICAL DATA

  • Lightning time with one fully charged battery (5.0 Ah)
  • High Level …………………………………………………………………………………………………….. 2,25 h
  • Med Level ……………………………………………………………………………………………………… 4,25 h
  • Low Level ………………………………………………………………………………………………………  8 h
  • Luminous flux
  • High Level …………………………………………………………………………………………………….. 3000 lm
  • Med Level ………………………………………………………………………………………………………  1700 lm
  • Low Level ………………………………………………………………………………………………………  900 lm
  • Colour rendering index (CRI)……………………………………………………………………………….. 80
  • Colour temperature……………………………………………………………………………………………..  4000 K
  • Battery voltage……………………………………………………………………………………………………  18 V
  • AC input …………………………………………………………………………………………………………….  100-240 V
  • Charger rated power input ……………………………………………………………………………………  110 W
  • Charger output……………………………………………………………………………………………………  18 V
  • Quick charge current …………………………………………………………………………………………..  3 A
  • Battery charging time with 5.0 Ah ………………………………………………………………………….  80 min
  • Battery charging time with 6.0 Ah ………………………………………………………………………….  100 min
  • Battery charging time with 9.0 Ah ………………………………………………………………………….  160 min
  • Weight without battery …………………………………………………………………………………………  9,2 kg
  • Weight according EPTA-Procedure 01/2014 (2.0 Ah) ………………………………………………  9,5 kg
  • Weight according EPTA-Procedure 01/2014 (5.0 Ah) ………………………………………………  9,9 kg
  • Weight according EPTA-Procedure 01/2014 (9.0 Ah) ………………………………………………  10,3 kg
  • Protection class ………………………………………………………………………………………………….  IP34

WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.

BATTERY LAMP SAFETY INSTRUCTIONS

Warning : Do not direct the light beam at persons or animals and do not stare into the light beam yourself (not even from a distance). Staring into the light beam may result in serious injury or vision loss.
Caution – this product is provided with cooling openings in the bottom enclosure. Only install this luminaire on a surface that will not allow accumulation of water into the housing. Keep the product away from puddles,etc.

CHARGER SAFETY INSTRUCTIONS
Do not store the battery pack together with metal objects (short circuit risk).

Battery Cat. No. DC Volts Capacity Cell No.
M18B 18 ≤ 1.5 Ah 5
M18BX 18 ≤ 3.0 Ah 2 x 5
M18B2 18 ≤ 2.0 Ah 5
M18B4 18 ≤ 4.0 Ah 2 x 5
M18B5 18 ≤ 5.0 Ah 2 x 5
M18B6 18 ≤ 6.0 Ah 2 x 5
M18B9 18 ≤ 9.0 Ah 3 x 5

Do not try to charge non-rechargeable batteries with this charger. No metal parts must be allowed to enter the battery section of the charger (short circuit risk).
Never break open battery packs and chargers and store only in dry rooms. Keep dry at all times. Do not touch the tool with conducting objects. Never charge a damaged battery pack. Replace by a new one. Before use check machine, cable, and plug for any damages or material fatigue. Repairs should only be carried out by authorised Service Agents. This appliance is not intended to be used or cleaned by persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given instructions concerning the safe use of the appliance by a person legally responsible for their safety. They should be supervised whilst using the appliance. Children shall not use, clean or play with this appliance, which when not in use should be secured out of their reach.
Warning! To reduce the risk of fire, personal injury, and product damage due to a short circuit, never immerse your tool, battery pack or charger in fluid or allow fluid to flow inside them. Corrosive or conductive fluids, such as seawater, certain industrial chemicals, and bleach or bleach-containing products, etc., can cause a short circuit.

ADDITIONAL SAFETY INSTRUCTIONS

  • Remove the battery pack before starting any work on the appliance.
  • Do not dispose of used battery packs in the household refuse or by burning them. Milwaukee Distributors off er to retrieve old batteries to protect our environment.
  • Do not store the battery pack together with metal objects (short circuit risk).
  • Use only compatible Milwaukee chargers from the same battery platform for charging battery packs. Do not use battery packs from other systems.
  • Battery acid may leak from damaged batteries under extreme load or extreme temperatures. In case of contact with the battery, acid washes it off immediately with soap and water. In case of eye contact rinse thoroughly for at least 10 minutes and immediately seek medical attention.
  • Warning! To reduce the risk of fire, personal injury, and product damage due to a short circuit, never immerse your tool, battery pack or charger in fluid or allow fluid to flow inside them. Corrosive or conductive fluids, such as seawater, certain industrial chemicals, and bleach or bleach-containing products, etc., can cause a short circuit.

SPECIFIED CONDITIONS OF USE

The area light is intended to be used light independently use away from mains supply. Additionally, the charger can charge the specified Milwaukee battery packs. Do not use this product in any other way as stated for normal use.

CHARGING
After inserting the battery into the reception of the charger the battery will automatically be charged (red lamp is illuminated continuously) When a hot or cold battery pack is inserted into the charger (fl ashing red lamp), charging will begin automatically once the battery reaches the correct charging temperature (0°C…60°C). Charging time varies depending on the battery temperature, charge needed and the type of battery pack being charged. As soon as charging is completed, the charger switches over to ”trickle” charge to maintain the full capacity (green control lamp is illuminated continuously, red lamp off ) If both LEDs fl ash at the same time, either the battery has not been completely mounted or there is a fault in the battery or the charger. For safety reasons you must stop using the charger and battery immediately and have them inspected by a Milwaukee Customer Service Centre.

BATTERIES

Battery packs which have not been used for some time should be recharged before use. Temperatures in excess of 50°C (122°F) reduce the performance of the battery pack. Avoid extended exposure to heat or sunshine (risk of overheating). The contacts of chargers and battery packs must be kept clean. For an optimum life-time, the battery packs have to be fully charged, after used. To obtain the longest possible battery life remove the battery pack from the charger once it is fully charged. For battery pack storage longer than 30 days: Store the battery pack where the temperature is below 27°C and away from moisture Store the battery packs in a 30% – 50% charged condition Every six months of storage, charge the pack as normal.

TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods Legislation requirements. Transportation of those batteries has to be done in accordance with local, national and international provisions and regulations.

  • The user can transport the batteries by road without further requirements.
  • Commercial transport of Lithium-Ion batteries by third parties is subject to Dangerous Goods regulations. Transport preparation and transport are exclusively to be carried out by appropriately trained persons and the process has to be accompanied by corresponding experts. When transporting batteries:
  • Ensure that battery contact terminals are protected and insulated to prevent short circuit.
  • Ensure that battery pack is secured against movement within packaging.
  • Do not transport batteries that are cracked or leak. Check with forwarding company for further advice.

MAINTENANCE

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. Use only Milwaukee accessories and spare parts. Should components need to be replaced which have not been described, please contact one of our Milwaukee service agents (see our list of guarantee/service addresses). If needed, an exploded view of the tool can be ordered. Please state the machine type printed as well as the six-digit No. on the label and order the drawing at your local service agents or directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.

SYMBOLS

milwaukee M18 HSAL LED Stand Light Charger 8

Copyright 2020
Techtronic Industries GmbH
Max-Eyth-Str. 10
71364 Winnenden
Germany
+49 (0) 7195-12-0
www.milwaukeetool.eu

Techtronic Industries (UK) Ltd
Fieldhouse Lane
Marlow Bucks SL7 1HZ
UK

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>