Orbegozo TEM 8000 INFRARED THERMOMETHER Instruction Manual
- June 5, 2024
- Orbegozo
Table of Contents
INFRARED THERMOMETER- INSTRUCTION
MANUAL
TEM 8000
SYMBOLS IN THIS MANUAL AND PRODUCT
| Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
---|---
| Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury to the user or patient or damage to the
equipment or other property.
| Type B applied part
| Authorised representative in the European community
| Refer to instruction manual/booklet
| Manufacturer
**LOT**
| Lot number
| The marking of electrical and electronic devices according to Directive
2002/96/EC.
The device, accessories and packaging have to be disposed of waste correctly
at the end of the usage. Please follow Local Ordinances or Regulations for
disposal.
General Safety Instructions
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children must never play with the appliance. Cleaning and user maintenance must never be carried out by children without supervision. -
Children should be supervised to ensure that they do not play with the appliance.
-
Keep the appliance and the cable cord out of the reach of children less than 8 years old.
-
WARNING: In order to ensure your children‘s safety, please keep all packaging (plastic bags, boxes, polystyrene etc.) out of their reach.
-
If the supply cord is damaged it must be repaired by the Authorized Service Agent to avoid a hazard.
-
Never pull on the cord when unplugging.
-
Do not use the unit with a damaged cord or plug, or if it is not working properly.
-
Do not handle the appliance with wet hands.
-
Never immerse the appliance in water or any other liquid.
-
Make sure the appliance has been unplugged before cleaning.
-
This appliance must be installed following the national regulations for electrical installations.
-
This appliance is for household use only.
-
In case that you need a copy of the instruction manual, you can find it in our website: www.orbegozo.com
-
WARNING: In case of misuse, there is a risk of possible injury.
-Please make sure to remove the sweat and hair on the forehead before the measurement.
-Use this thermometer is not intended as a substitute for consultation with your physician.
-Please contact our distributor when there is a problem.
-Please don’t try to repair it by yourself.
-Please do not use the product in the humidity rangeabove 85%.
-Please keep the product away from electromagnetic range (for example radio, mobiles, and so on)
-The product may not be exposed to the sun, close to the fire, also immersed into water.
-Never impact or hard hit the product, don’t use it if it has been damaged.
-The measurement value can be influenced by the sweat on the forehead, hat or scarf. Make sure the measure distance is between 1cm to 3 cm.
FEATURES
Non ‒Contact and with high accuracy of measurement
Two kinds of measurement mode selection:body temperature and surface
temperature
The exchange between ℃ and ℉.
a). Input the battery
b). Waiting for 10 minutes for the first time or just insert the battery
c). In case when it’s not used for long time, it will detect the environment
temperature first so it will take one or two seconds more to switch on.
d). Focus on the forehead and keep 1-3cm distance then press the button to
start testing. It will display the testing data within one second. Be sure
there is no hair, sweat, cosmetics or hat to cover the forehead.
Providing the function of sound notification of high body temperature.
Capable of storing 32 sets for the latest measurement data.
Providing the function of saving the date and auto turn off.
Providing the function of auto-selection the range, LCD display resolution:0.1
℃(0.1℉). Backlight LCD digital display
The range of the normal temperature in different ages
Age | Temperature ºC | Temperature ºF |
---|---|---|
0-2 | 36.4-38.0 | 97.5-100.4 |
10-Mar | 36.1-37.8 | 97.0-100.0 |
Nov-65 | 35.9-37.6 | 96.6-99.7 |
>65 | 35.8-37.5 | 96.4-99.5 |
TEM 8000
-
Body temperature mode
-
Surface temperature mode
-
Result
-
Alarm signal
-
Temperature℃ /℉
-
Low battery warning
-
Storage
-
Checking saved data
-
Infrared probe
-
LCD screen
-
Mode
-
Down
-
Up
-
Backlight switch
-
Testing key
-
Battery cover
OPERATION
a). Input the battery
b). Waiting for 10 minutes for the first time or just insert the battery
c). In case when it’s not used for a long time, it will detect the environment
temperature first so it will
take one or two seconds more to switch on.
d). Focus on the forehead and keep 1-3cm distance then press the button to
start testing. It will display the testing data within one second. Be sure
there is no hair, sweat, cosmetics or hat to cover the forehead.
SETTING
a). Setting the format of the temperature F1
Keep pressing“ MODE” for 3 seconds till the screen display F1, the press“ ▼
”to choose ℃ and“ ▲ ”for ℉
b). Alarm temperature setting F2
Keep pressing“ MODE” for 3 seconds till the screen display F1 then press“
MODE” again to enter into
F2 then press“ ▲ ”for increasing alarm temperature 0.1℃ (0.1℉) and press“ ▼”
for decreasing 0.1℃ (0.1℉).
Attention: The default alarm temperature is 38.0℃ (100.4℉)
c). Buzzer ON/OFF F3
Press the “ MODE” button for 3 seconds till the screen display F1 then press“
MODE” twice to enter into F3 then press“▼”to close the buzzer (a sound icon
disappear) and press“ ▲” to open the buzzer ( a sound icon is displayed on the
LCD screen)
d). Out of setting
Keep pressing ” until it’s power off.
e). Measuring mode setting
Press“MODE”key to the human body and the surface mode conversion.Under the
MODE of body surface measurement rang is: 0.0~100.0℃(32.0℉-212.0℉)
This product is specialized for testing human being’s body temperature so the
displaying temperature range is 32.0℃-43.0℃(89.0℉-109.4℉)
Disposal of old electrical appliances.
The European directive 2002/96/EC on Waste Electrical and Electronic Equipment
(WEEE), requires that old household electrical appliances must not be disposed
of in the normal unsorted municipal waste stream. Old appliances must be
collected separately in order to optimize the recovery and recycling of the
materials they contain, and reduce the impact on human health and the
environment. The crossed out “wheeled bin” symbol on the product reminds you
of your obligation, that when you dispose of the appliance, it must be
separately collected. Consumers should contact their local authority or
retailer for information concerning the correct disposal of their old
appliance.
DECLARATION OF CONFORMITY: This device complies with the requirements of the
EMC directive 2014/30/EU
Shenzhen Calibeur Industries Co., Ltd No.11 Bldg.,
Shiguan Industrial Park, Gongming, Guangming District, Shenzhen.
China Te1:86-755-26010950 Fax:86-755-26736969
ALTHOME France Z.A.32390
MONTESTRUC/gers Te1:00335 62 62 23 23
Fax:00335 62 62 21 13
Sonifer, S.A.
sonifer@sonifer.es /
web: www.orbegozo.com
Made in PRC
Documents / Resources
|
Orbegozo TEM 8000 INFRARED
THERMOMETHER
[pdf] Instruction Manual
TEM 8000, INFRARED THERMOMETHER, TEM 8000 INFRARED THERMOMETHER
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>