Amica Joran VM 9001 Vacuum Cleaner Instruction Manual
- June 5, 2024
- Amica
Table of Contents
Joran VM 9001 Vacuum Cleaner
Instruction Manual Joran PET Turbo VM 9011
Joran VM 9001
Joran Turbo VM 9012
Joran PET VM 9002
Hand vacuum
Cordless vacuum cleaner
THANK YOU FOR PURCHASING AN AMICA APPLIANCE
DEAR CUSTOMER , Your Amica appliance is exceptionally easy to use and
extremely efficient. Before being packaged and leaving the manufacturer, the
appliance was thoroughly checked with regard to safety and functionality.
Before using the appliance, please carefully read these Operating
Instructions
The appliance is designed for household use only.
The manufacturer reserves the right to introduce changes, which do not affect
the operation of the appliance.
The pictures in this operating instructions are for illustration only.
DISPOSING/SCRAPPING OF USED EQUIPMENT
UNPACKING
During transportation, protective packaging was used to protect the appliance against any damage. After unpacking, please dispose of all elements of packaging in a way that will not cause damage to the environment. All materials used for packaging the appliance are environmentally friendly; they are 100% recyclable and are marked with the appropriate symbol. Important! Packaging materials (bags, polyethylene, polystyrene, etc.) should be kept away from children during unpacking.
DISPOSAL OF OLD APPLIANCE
In accordance with European Directive 2012/19/EU and local legislation regarding used electrical and electronic goods, this appliance is marked with the symbol of the crossed-out waste container. This marking indicates that the appliance must not be disposed of together with other household waste after it has been used. The user is obliged to hand it over to the waste collection center collecting used electrical and electronic goods. The collectors, including local collection points, shops, and local authority departments pro video recycling schemes. Proper handling of used electrical and electronic goods helps avoid environmental and health hazards resulting from the presence of dangerous components and the inappropriate storage and processing of such goods.
DISCARDING THE VACUUM AND BATTERY PACK
Before you discard this vacuum, dispose of the battery in an environmentally
safe manner. Do not discard batteries with your regular household trash.
To preserve natural resources, please recycle or dispose of expired
battery packs properly. This product contains a lithium-ion battery. It must
be disposed of properly. Local laws may prohibit the disposal of lithium-ion
batteries in ordinary trash. Consult your local waste authority for
information regarding available recycling and/or disposal options.
The properties of lithium-ion batteries depending on usage may slightly
deteriorate over time. It is possible to change the 25,2V / 230V battery by
service and purchase. Detailed information on our website:
https://czescizamienne.amica.pl/Product/Part
WARRANTY AND AFTER-SALES SERVICE
Warranty
Warranty service as stated on the warranty card. The manufacturer shall not be
held liable for any damage caused by improper use of the product.
Manufacturer’s Declaration
The manufacturer hereby declares that this product meets the requirements of
the following European directives:
- Low Voltage Directive 2014/35/EC
- Electromagnetic Compatibility (EMC) Directive 2014/30/EC
- ErP Directive 2009/125/EC
- Directive RoHS 2011/65/EC
And has thus been marked with the symbol and been issued with a declaration of compliance made available to market regulators.
SAFETY INSTRUCTIONS FOR USE
Important! To minimize the risk of fire, electric shock or injury :
- Carefully read this instruction before using the appliance.
- Children do not realize the dangers that can arise when using electrical appliances; therefore keep the appliance out of reach of children.
- Do not immerse the body of the appliance in water or other liquids. Immersing in water may cause an electric shock.
- Prevent unintentional starting. Ensure the switch is in the off-position before connecting to the battery pack, picking up, or carrying the appliance. Carrying the appliance with your finger on the switch or energizing appliance that has the switch on invites accidents.
- Do not use the appliance if it shows any signs of damage to the power cord, or if the appliance has been dropped on the floor.
- Do not touch the nozzle when the vacuum cleaner is on.
- Do not put any object into openings.
- Do not use with any openings blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
- Do not attempt to remove any parts of the housing.
- Do not use outdoors or on wet surfaces.
- Do not expose the appliance to rain or humidity, and do not use it outdoors. Do not operate the appliance with wet hands.
- Do not operate the vacuum cleaner or charger if it has been damaged in any way.
- Never place the appliance on hot surfaces.
- If the vacuum cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, call Customer Service.
- To avoid excessive heat and damage to the unit or battery, the vacuum cleaner will not operate while charging.
- Using attachments that were not supplied with the product may cause damage to the appliance.
- Use only the manufacturer’s recommended attachments.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- The surface on which the appliance is used shall be leveled, clean, and dry.
- Use appliances only with specifically designated battery packs.
- The use of any other battery packs may create a risk of injury and fire.
- Do not insert any objects into the openings in the vacuum cleaner. Do not use the vacuum cleaner when any opening is blocked, dispose of dust, lint, hair, and anything that may restrict airflow.
- Keep hair, loose clothing parts, fingers, and other body parts away from the openings and moving parts.
- Do not use the vacuum cleaner to collect flammable substances such as petrol and do not use it in places where similar substances may be present.
- Liquid ejected from the battery may cause irritation or burns.
- If the liquid gets on the skin, (1) seek medical attention, (2) wash quickly with soap and water, and (3) neutralize with a mild acid such as lemon juice or vinegar
- If the liquid gets into the eyes, flush them immediately with clean water for a minimum of 10 -Rev minutes.
- When the battery pack is not in use, keep it away from other metal objects, like paper clips, coins, keys, nails, screws, or other small metal objects, that can make a connection from one terminal to another.
- Shorting the battery terminals together may cause burns or a fire.
- The product is intended for use at a temperature of 4.5 ° C to 40 ° C.
- Do not collect any items that burn or smoke, such as cigarettes, matches or hot ashes.
- Do not use the vacuum cleaner without a dust container and filters.
- If the opening, which sucks air, hose, or telescopic tube is clogged, you should immediately switch the vacuum cleaner off. Before restarting the vacuum cleaner, first, remove the blocking item.
- Do not use the vacuum cleaner too close to heaters, radiators, cigarette butts, etc.
- Do not collect fine particles such as flour, gypsum, printer toners, etc., as this may clog filters and damage the vacuum cleaner.
- Overcharging, short-circuiting, reverse charging, mutilating or incinerating the cells and the batteries must be avoided.
- If a cell or a battery has leaked or vented, it should be replaced immediately using protective gloves.
- Reverse polarity installation of the cell or the battery in the end product must be avoided.
- Keep the lithium-ion battery in a cool, dry place.
- The lithium-ion battery will be charged by the manufacturer to the level of 40%. After purchase, it should be topped up to 100%. This is to extend the battery life.
DESCRIPTION OF THE APPLIANCE
Appliance components (Fig. 1, item …)
- Handle
- Power button
- Lower cover
- Nozzle
- Dust cup lever
- Dust container
- Filter cover
- Li-ion battery
- Charging port
- Detachable hand vacuum
- Release button for hand vacuum
- Tube
- Release button for floor nozzle
- Electro brush
- Backlight LED electro brush
Attachments (Fig. 2. item…)
(1) Tube | 1 |
---|---|
(2) Battery | 1 |
(3) Wall mount | 1 |
(4) Charger | 1 |
(5) Crevice tool | 1 |
(6) Suction for slots and books 2 in 1 | 1 |
(7) Suction for upholstery/sofa | 1 |
(8) Suction for hair / PET* | 1 |
(9) Roller | 1 |
(10) Electro Brush with LED backlight | 1 |
Working time of the vacuum cleaner Joran in different power modes – about 16
min / 40 min. Working time of the vacuum cleaner Joran PET Turbo in different
power modes – about 10 min / 20 min/eco 50 min.
Easy assembly
- Slide battery onto hand vacuum until firmly attached (Fig. 3, item 1).
- Slide wand onto hand vacuum until it clicks (Fig. 3, item 2).
- Push the tube into the motorized floor nozzle until it clicks (Fig. 3, item 3).
How to install wall mount
- Choose location near a power outlet. Locate point high enough on the wall to allow the wand and motorized floor nozzle to hang freely.
- Place mount against wall and use a pencil to mark drill holes.
- Drill holes (with 1/4″ bit) and insert drywall anchors. Insert screws through holes on the mount and tighten until firmly attached (Fig. 3, item 4).
How to charge battery and store accessories (Fig. 3, item 5).
- Place assembled vacuum cleaner on the wall mount.
- Plug charger into a power outlet and then into charger port on hand vac.
- Loop charger cord into clips on sides of wall mount.
- Snap tool(s) into tool storage areas.
Battery indicator lights show the level of charge (Fig. 3, item 5).
- Indicator lights stop blinking when fully charged.
- Charge the battery fully before using for the first time.
- This may take up to 4-6 hours.
Working time of the vacuum cleaner Joran in different power modes – about 16
min / 40 min. Working time of the vacuum cleaner Joran PET Turbo in different
power modes – about 10 min / 20 min/eco 50 min.
The operating time of the vacuum cleaner may vary depending on the brushes
used and the conditions of use.
CLEANING AND MAINTENANCE
Empty dust cup after every use
There are two ways to empty the dust cup:
- Hold cleaner over the wastebasket. Press the lever to release the bottom lid of the dust cup to empty debris (Fig. 4, item 1).
- Or, remove the dust cap from the hand vacuum by twisting to the
unlock’ position (Fig. 4, item 2). Once emptied, reattach the dust cup by lining up the arrow and
unlock’ position. Twist dust cup until arrow lines up with `locked’ position.
How to use hand vacuum and accessories
Moving parts! Always turn off the hand vacuum before attaching accessories.
The hand vacuum can be used with or without tools.
- To use without tools, press the release button and remove the wand. Collect debris directly with a hand vacuum nozzle (Fig. 4, item 1).
- To use tools with a wand, press the release button to remove the motorized floor nozzle. Slide tool onto end of wand until it clicks (Fig. 4, item 2).
- To use tools with hand vacuum only, press release button to remove the wand. Slide tool onto hand vacuum until it clicks (Fig. 4, item 3).
Suction for slots and books 2 in 1: Use a brush to vacuum blinds, vents, or
upholstered surfaces. Crevice tool: Cleans hard-to-reach areas such as
corners, baseboard edges, dryer vents, nooks in the car, and cobwebs on the
ceiling. Use felt portion to clean delicate surfaces. To switch between felt
and brush portions, press the thumb release and slide the brush up or down.
How to use hand vacuum and motorized floor nozzle Ideal for cleaning stairs.
(Fig. 5, item 1).
- Press the release button to remove the wand from the hand vacuum. Attach motorized floor nozzle directly to hand vacuum.
- Click the power button once to start.
Brushroll maintenance – clean frequently
- Place motorized floor nozzle upside down. Use scissors or knives to cut strings and threads.
Brushroll maintenance – (Fig. 5, item 2, 3).
- If debris cannot be removed easily, remove the retainer clip to access brushroll. Using a flathead screwdriver or coin, turn screw to the `unlock’ position.
- Remove retainer clip and lift out brush roll to clean and remove debris.
- To reassemble:
- Align one end of brush roll with floor nozzle gear.
- Press another end into the slot.
- Hook retainer clip under tab and press down.
- Insert screw and turn to `lock’ position.
Washable dust cup filter – clean frequently
- Twist the dust cup and remove.
- Twist filter screen and remove.
- Lift out foam filter and holder.
- Separate foam filters from fiber filters by pulling them apart.
- Rinse and dry THOROUGHLY
- Reassemble once completely dry
Washable post-motor filter (EPA10) clean every 6 months
- Twist filter cover and remove.
- Lift out post-motor filter.
- Shake to remove dust.
- Every 6 months, replace the filter or rinse and dry THOROUGHLY.
- Reposition filter and cover and twist to `lock.’
PROBLEM-SOLVING
Make sure the vacuum cleaner is off.
NOTICE Thermal cut-off
This vacuum cleaner has a special thermostat that protects the vacuum cleaner
when the battery overheats. If the vacuum suddenly shuts off, proceed as
follows: 1) Check the vacuum for a possible source of overheating such as a
full dust cup, blocked wand, or clogged filters. If these conditions are
found, fix them and wait at least 30 minutes before attempting to use the
vacuum. 2) After the 30-minute period, press the power button.
Problem| Solution
The motor will not start| Make sure the cleaner is fully powered.
Push the charger securely into an electrical outlet, try another outlet or
check the circuit breaker.
See detailed “thermal cut-off’ instructions above.
Charging indicator lights are not lit while charging| Make sure the charger is
securely inserted into an electrical outlet.
Make sure the charging plug is securely inserted into the hand vac.
Indicator lights stop blinking when fully charged.
Amica S.A. ul.Mickiewicza 52
64-510 Wronki tel. 67 25 46 100
fax 67 25 40 320
www.Amica.pl
IO-SDA-0224 (02.2022./1)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>