IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS

IMPORTANT NOTICE

This guide provides installation and operation instructions for this pump. Consult Pentair with any questions regarding this equipment.

Attention Installer: This guide contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment after installation or left on or near the pump.

Attention User: This manual contains important information that will help you in operating and maintaining this product. Please retain it for future reference.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury.

Danger: Warns about hazards that can cause death, serious personal injury, or major property damage if ignored.

Warning: Warns about hazards that may cause death, serious personal injury, or major property damage if ignored.

Caution: Warns about hazards that may or can cause minor personal injury or property damage if ignored.

NOTE Indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing or damaged.

When installing and using this electrical equipment, basic safety precautions should always be followed, include the following:

Warning: Do not permit children to use this product.

Warning: RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a ground-fault circuitinterrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI.

Warning: This unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service representative before using.

Caution: This pump is for use with permanent swimming pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.

General Warnings

  • Never open the inside of the drive motor enclosure. There is a capacitor bank that holds a 230 VAC charge even when there is no power to the unit.
  • The pump is not submersible.
  • The pump is capable of high flow rates; use caution when installing and programming to limit pumps performance potential with old or questionable equipment.
  • Code requirements for electrical connection differ from country to country, state to state, as well as local municipalities. Install equipment in accordance with the National Electrical Code and all applicable local codes and ordinances.
  • Before servicing the pump; switch OFF power to the pump by disconnecting the main circuit to the pump.
  • This appliance is not intended for use by persons (including children) of reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

Danger: FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S MANUAL BEFORE USING THIS PUMP. THESE WARNINGS AND THE OWNER’S MANUAL MUST BE LEFT WITH THE POOL OWNER.

Danger: SUCTION ENTRAPMENT HAZ ARD: STAY OFFTHE MAIN DRAIN AND AWAY FROM ALL SUCTION OUTLETS!
Danger icon

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE MAIN DRAIN AT THE BOTTOM OF THE BODY OF WATER. THIS SUCTION IS SO STRONG THAT IT CAN TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO A DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.

THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAPMENT, EVISCERATION AND/OR DEATH.

The suction at a drain or outlet can cause:

Limb Entrapment: When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.

Hair Entanglement: When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This hazard is present when the flow rating of the cover is too small for the pump or pumps. Body Entrapment: When a portion of the body is held against the drain cover trapping the swimmer underwater. This hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or pumps.

Evisceration/Disembowelment: When a person sits on an open pool (particularly a child wading pool) or spa outlet and suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover is missing, loose, cracked, or not properly secured.

Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly secured.

NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL CODES, STANDARDS AND GUIDELINES

Warning: TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD:

  • A properly installed and secured ANSI/ASME A112.19.8 approved anti-entrapment suction cover must be used for each drain.
  • Each suction cover must be installed at least three (3’) feet apart, as measured from the nearest point to nearest point.
  • Regularly inspect all covers for cracks, damage and advanced weathering.
  • If a cover becomes loose, cracked, damaged, broken or is missing, replace with an appropriate certified cover.
  • Replace drain covers as necessary. Drain covers deteriorate over time due to exposure to sunlight and weather.
  • Avoid getting hair, limbs or body in close proximity to any suction cover, pool drain or outlet.
  • Disable suction outlets or reconfigure into return inlets.

Warning: A clearly labeled emergency shut-off switch for the pump must be in an easily accessible, obvious place.

Make sure users know where it is and how to use it in case of emergency.

The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new requirements for owners and operators of commercial swimming pools and spas.

Commercial pools or spas constructed on or after December 19, 2008, shall utilize:

  • A multiple main drain system without isolation capability with suction outlet covers that meet ASME/ANSI A112.19.8a Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:

  • A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured Safety Vacuum Release systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems and/or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming pools, Spas and Hot Tubs or

  • A properly designed and tested suction-limiting vent system or

  • An automatic pump shut-off system.
    Commercial pools and spas constructed prior to December 19, 2008, with a single submerged suction outlet shall use a suction outlet cover that meets ASME/ANSI A112.19.8a and either:

  • A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or

  •  A properly designed and tested suction-limiting vent system, or

  • An automatic pump shut-off system, or

  • Disabled submerged outlets, or

  • Suction outlets shall be reconfigured into return inlets.

For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches, Timers and Automation Load Center)

Caution:

** Install all electrical controls at equipment pad, such as on/off switches, timers, and control systems, etc. to allow the operation (startup, shut-down, or servicing)
of any pump or filter so the user does not place any portion of his/her body over or near the pump strainer lid, filter lid or valve closures. This installation should allow the user enough space to stand clear of the filter and pump during system start-up, shut down or
servicing of the system filter.
Danger: HAZARDOUS PRESSURE: STAND CLEAR OF PUMP AND FILTER DURING START UP**

Circulation systems operate under high pressure. When any part of the circulating system (i.e. locking ring, pump, filter, valves, etc.) is serviced, air can enter the system and become pressurized.

Pressurized air can cause the pump housing cover, filter lid, and valves to violently separate which can result in severe personal injury or death. Filter tank lid and strainer cover must be properly secured to prevent violent separation. Stand clear of all circulation system equipment when turning on or starting up pump.

Before servicing equipment, make note of the filter pressure. Be sure that all controls are set to ensure the system cannot inadvertently start during service. Turn off all power to the pump. IMPORTANT: Place filter manual air relief valve in the open position and wait for all pressure in the system to be relieved.

Before starting the system, fully open the manual air relief valve and place all system valves in the “open” position to allow water to flow freely from the tank and back to the tank. Stand clear of all equipment and start the pump.

IMPORTANT: Do not close filter manual air relief valve until all pressure has been discharged from the valve and a steady stream of water appears. Observe filter pressure gauge and be sure it is not higher than the pre-service condition.

General Installation Information

  • All work must be performed by a qualified service professional, and must conform to all national, state, and local codes.
  • Install to provide drainage of compartment for electrical components.
  • These instructions contain information for a variety of pump models and therefore some instructions may not apply to a specific model. All models are intended for use in swimming pool applications. The pump will function correctly only if it is properly sized to the specific application and properly installed.

Warning: Pumps improperly sized or installed or used in applications other than for which the pump was intended can result in severe personal injury or death. These risks may include but not be limited to electric shock, fire, flooding, suction entrapment or severe injury or property damage caused by a structural failure of the pump or other system component.

Warning The pump can produce high levels of suction within the suction side of the plumbing system. These high levels of suction can pose a risk if a person comes within the close proximity of the suction openings. A person can be seriously injured by this high level of vacuum or may become trapped and drown. It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes for swimming pools.

Warnings and safety instructions for Pentair Aquatic Systems pumps and other related products are available at: http://www.pentairpool.com/pool-owner /safety-warnings/ or call 800-831-7133 for additional free copies of these instructions.

Please refer to http://[www.pentairpool.com](http://www.pentairpool.com )/pool-owner/ **safetywarnings/** for warning and safety instructions related to the this product.

SAVE THESE INSTRUCTIONS

Pump Overview

The perfect choice for all types of pools, the SuperFlo® High Performance Pump was specifically designed to be your best choice for a variety of inground pools. Thick walled body parts, a heavy duty 56 square flange motor, and highly engineered hydraulics make this rugged and tested design perfect for any pool, spa, water feature, or fountain.

All pumps from Pentair Aquatic Systems incorporate innovative hydraulic engineering that has been refined for over 40 years. Compact, rugged, and easy to maintain, the SuperFlo pump will deliver years of reliable service.
Pump Overview
Super Flo High Performance Pump

General Features

  • Extremely quiet operation
  • Unionized fittings (1.5” and 2”) for simple replacement
  • Cam and Ramp™ Lid for easy cleaning and maintenance
  • Heavy-duty, high service factor 56 square flange motor for long life
  • Integral volute and pot reduce hydraulic noise
  • See-through lid permits easy inspection of strainer basket
  • 115 volt or 230 volt models available
  • 1/2 HP to 2 1/2 HP configurations to accommodate a wide range of applications
  • Self-priming for quick, easy start-up

INSTALLATION

Only a qualified plumbing professional should install the SuperFlo® High Performance Pump. Refer to “Pump Warning And Safety Instructions” on pages ii- iii for additional installation and safety information.

Location

Be sure the pump location meets the following requirements.

Note: Do not install this pump within an outer enclosure or beneath the skirt of a hot tub or spa unless marked accordingly.

  1. Install the pump as close to the pool or spa as possible. To reduce friction loss and improve efficiency, use short, direct suction piping returns.

  2. Install a minimum of 5 feet (1.52 meters) from the inside wall of the pool and spa. Canadian installations require a minimum of 9.8 feet (3 meters) from pool water level.
    Pump Rear Clearance
    Pump Rear Clearance

  3. Install the pump a minimum of 3 feet (.9 meters) from the heater outlet.

  4. Do not install the pump more than 10 feet (3 meters) above the water level.

  5. Install the pump in a well ventilated location protected from excessive moisture (i.e., rain gutter downspouts, sprinklers, etc.)

  6. Install the pump with a rear clearance of at least 3 inches (76.2 mm) so that the motor can be removed easily for maintenance and repair.
    Recommended Piping
    Recommended Piping

Piping

  1. For improved pool plumbing, it is recommended to use a larger pipe size. When installing the inlet and outlet fittings (male adaptors), use thread sealant.
  2. Piping on the suction side of the pump should be the same or larger than the return line diameter.
  3. Plumbing on the suction side of the pump should be as short as possible.
  4. For most installations Pentair recommends installing
    • valve on both the pump suction and return lines so that the pump can be isolated during routine maintenance. However, we also recommend that
    • valve, elbow or tee installed in the suction line should be no closer to the front of the pump than five (5) times the suction line diameter.

Example: A 2 inch pipe requires a 10 inch (25.4 cm) straight run in front of the suction inlet of the pump. This will help the pump prime faster and lastlonger.

Note: DO NOT install 90° elbows directly into the pump inlet or outlet.

Fittings and Valves

  1. Do not install 90° elbows directly into pump inlet.
  2. Flooded suction systems should have gate valves installed on suction and discharge pipes for maintenance, however, the suction gate valve should be no closer than five times the suction pipe diameter as described in this section.
  3. Use a check valve in the discharge line when using this pump for any application where there is significant height to the plumbing after the pump.
  4. Be sure to install check valves when plumbing in parallel with another pump. This helps prevent reverse rotation of the impeller and motor.

Warning:

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pump must be installed by a licensed or certif ied electrician ora qualified service professional in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to users, installers, or others due to electrical shock, and may also cause damage to property.

Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to service people, pool users or others due to electric shock and/or property damage. Read all servicing instructions before working on the pump.

Electrical Wiring Installation

  1. Be sure all electrical breakers and switches are turned off before wiring motor.

  2. Be sure that the wiring voltage matches the motor  voltage (230 VAC or 115 VAC). If they do not match, the motor can overheat.

  3. Use the correct wire size and type specified by the current National Electrical Code. When in doubt use a heavier gauge (larger diameter) wire. Heavier gauge will allow the motor to run cooler and more efficient.

  4. Be sure all electrical connections are clean and tight.

  5. Cut wires to the appropriate length so they do not overlap or touch when connected to the terminal board.

  6. Permanently ground the motor using the green ground terminal located on the inside of the motor canopy or access plate, see image. Use the correct wire size and type specified by the current National Electrical Code. Be sure the ground wire is connected to an electrical service ground.

  7. Bond the motor to the pool structure in accordance with the current National Electrical Code. UL requires use of a solid copper bonding conductor not smaller than 8 AWG.
    Note: When pump is mounted permanently within 5 ft. (1.52 meters) of the inside walls of a swimming pool, you must use a No. 8 AWG or larger conductor to connect to bonding conductor lug. Pentair offers 2-Pole 20 Amp GFCI breakers (P/N PA220GF) which offer 6 milliamp personnel protection while meeting 2008 to current NEC Standards for Pool Pumps.

  8. Connect the wire from the accessible wire connector on the motor to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within 5 feet (1.52 meters) of the inside walls of the swimming pool, spa, or hot tub. For Canada, a 6 AWG or larger solid copper bonding conductor is required.

  9. The pump should be permanently connected to either a circuit breaker, 2-pole timer or 2-pole relay. If AC power is supplied by a GFCI circuit breaker, use a dedicated circuit breaker that has no other electrical loads.

  10. Connect the pump permanently to a circuit. Make sure no other lights or appliances are on the same circuit.

Note: When the pump is started and stopped by removing power with a relay or timer, a two-pole device should be used to apply and remove power to both POWER LINE TERMINALS.
Electrical Wiring Installation
Field Wiring Compartment

MAINTENANCE

Warning: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then open with extreme caution

Caution: o prevent damage to the pump and for proper operation of the system, clean pump strainer and skimmer baskets regularly.

Pump Strainer Basket

The pump straine r basket (or ‘strainer pot’, ‘hair and lintpot’), is located in front of the volute. Inside the chamber is the basket which must be kept clean of leaves and debris at all times. View basket through the ‘See Through Lid’ to inspect for leaves and debris.

Regardless of the length of time between filter cleaning, it is most important to visually inspect the basket at least once a week. A dirty basket will reduce the efficiency of the filter and heater and also put an abnormal stress on the pump motor which would result in a costly repair bill.

Cleaning the Pump Strainer Basket

  1. Turn off the pump at the circuit breaker.
  2. Relieve pressure in the system by allowing the water to cool.
  3. Gently tap the clamp in a counter-clockwise direction to remove the clamp and lid.
  4. Remove debris and rinse out the basket. Replace the basket if it is cracked.
  5. Put the basket back into the housing. Be sure to align the notch in the bottom of the basket with the rib in the bottom of the volute.
  6. Fill the pump pot and volute up to the inlet port with water.
  7. Clean the cover, O-ring, and sealing surface of the pump pot. Note: It is important to keep the lid O-ring clean and well lubricated.
  8. Reinstall the lid by placing the lid on the pot. Be sure the lid O-ring is properly placed. Seat the clamp and lid on the pump then turn clockwise until the handles are horizontal.
  9. Turn the power “ON” at the house circuit breaker. Reset the pool time clock to the correct time.
  10. Open the High Flow manual air relief valve on top of the filter.
  11. Stand clear of the filter. Start the pump.
  12. Bleed air from the filter until a steady stream of water comes out. Close the High Flow™ Manual Air Relief Valve.

Warning: THIS SYSTEM OPERATES UNDER HIGH
PRESSURE. When any part of the circulating system (e.g., Lock Ring, Pump, Filter, Valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the lid to separate which can result in serious injury, death, or property damage. To avoid this potential hazard, follow above instructions.

Winterizing

You are responsible for determining when freezing conditions may occur. If freezing conditions are expected, take the following steps to reduce the risk of freeze damage. Freeze damage is not covered under warranty.

To prevent freeze damage, follow the procedures below:

  1. Shut off electrical power for the pump at the circuit breaker.
  2. Drain the water out of the pump housing by removing the two thumb-twist drain plugs from the housing. Store the plugs in the pump basket.
  3. Cover the motor to protect it from severe rain, snow and ice.

Note: Do not wrap motor with plastic or other air tight materials during winter storage. The motor may be covered during a storm, winter storage, etc., but never when operating or expecting operation.

In mild climate areas, when temporary freezing conditions may occur, run your filtering equipment all night to prevent freezing.
Winterizing

Warning: Always disconnect power to the pump at the circuit breaker and disconnect the communication cable before servicing the pump. Failure to do so could result in death or serious injury to service people, users or others due to electric shock. Read all servicing instructions before working on the pump.

Warning: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to touch, then open with extreme caution.

Caution: Be sure not to scratch or mar the polished shaft seal faces; seal will leak if faces are damaged. The polished and lapped faces of the seal could be damaged if not handled with care.

Care of Electric Motor

Protect from heat

  1. Shade the motor from the sun.
  2. Any enclosure must be well ventilated to prevent overheating.
  3. Provide ample cross ventilation.

Protect against dirt

  1. Protect from any foreign matter or splashing water.
  2. Do not store (or spill) chemicals on or near the motor.
  3. Protect from any foreign matter or splashing water.
  4. Avoid sweeping or stirring up dust near the motor while it is operating.
  5. If a motor has been damaged by dirt it voids the motor warranty.
  6. Clean the lid and clamp, O-ring, and sealing surface of the pump pot.

Protect against moisture

  1. Protect from splashing or sprayed water.
  2. Protect from extreme weather.
  3. Protect from any foreign matter or splashing water.
  4. If a motor has become wet – let it dry before operating. Do not allow the pump to operate if it has been flooded.
  5. If a motor has been damaged by water it voids the motor warranty

Note: When replacing the motor, be certain that the motor support is correctly positioned to support the size of motor being installed.

Shaft Seal Replacement

The Shaft Seal consists primarily of two parts, a rotating member and a ceramic seal.
The pump requires little or no service other than reasonable care, however, a Shaft Seal may occasionally become damaged and must be replaced.

Note: The polished and lapped faces of the seal could be damaged if not handled with care.

Pump Disassembly

All moving pa rts are located in the rear sub-assembly of this pump.

Tools required:

  • 1/4 inch socket or open end wrench.
  • 9/16 inch open end wrench.
  • 1/2 inch or 7/16 inch open end wrench
  • Flat blade screwdriver.

To remove and repair the motor subassembly, follow the steps below:

  1. Turn off the pump circuit breaker at the main panel.
  2. Drain the pump by removing the drain plugs.
  3. Remove the 4 bolts that hold the main pump body (strainer pot/volute) to the rear sub-assembly.
  4. GENTLY pull the two pump halves apart, removing the rear sub-assembly.
  5. Remove the three hex head screws holding the diffuser in position.
  6. Hold the impeller securely in place and remove the impeller lock screw by using a flat blade screwdriver or wrench. The screw is a left-handed thread and loosens in a clockwise direction.
  7. Remove the shaft cap located at the back of the motor and hold the shaft secure with a 1/2 inch (Century® motors) or 7/16 inch (Franklin Electric® Motors) open-end wrench. On AO Smith® motors, remove the motor canopy, move the capacitor to one side and hold the shaft with a 7/16 inch openend wrench.
  8. To unscrew the impeller from the shaft, twist the impeller counter-clockwise.
  9. Remove the four bolts from the seal plate to the motor using a 9/16 inch wrench.
  10. Place the seal plate face down on a flat surface and tap out the ceramic seal.
  11. Clean the seal plate, seal housing, and the motor shaft.

Caution: DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level. If the water level falls below the suction port, the pump will draw air through the suction port, losing the prime and causing the pump to run dry, resulting in a damaged seal. Continued operation in this manner could cause a loss of pressure, resulting in damage to the pump case, impeller and seal and may cause property damage and personal injury.

Pump Reassembly

  1. When installing the replacement seal into the seal plate, use soapy water to wet the rubber boot before pressing it into the seal plate.
  2. Remount the seal plate to the motor.
  3. Before installing the rotating portion of the seal on the motor shaft, wet the motor shaft with soapy water and slide the seal onto the motor shaft. Ensure that the carbon face contacts the ceramic face of the stationary seat. Press the seal into the seal plate with your thumbs and wipe off the ceramic with a clean cloth.
  4. Grease the motor shaft thread and screw impeller onto the motor shaft.
  5. Screw in the impeller lock screw (counter-clockwise to tighten).
  6. Remount the diffuser onto the seal plate. Make sure the plastic pins and holding screw inserts are aligned.
  7. Grease the diffuser quad ring and seal plate O-ring prior to reassembly.
  8. Grease the bolt threads, assemble the motor subassembly to the strainer pot-pump  body by usingthe two through bolts for proper alignment. Do not tighten the through bolts until all 4 bolts are in place and finger tightened.
  9. Fill the pump with water.
  10. Reinstall the pump lid and plastic clamp; see the next section, ‘Restart Instructions’.
  11. Reprime the system.

Restart Instructions

If pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pot on pump. Make sure to re-open valves prior to operating.

Priming the Pump

The pump strainer pot must be filled with water before the pump is initially started.

Follow these steps to prime the pump:

  1. Remove the pump lid plastic clamp. Remove the pump lid.
  2. Fill the pump strainer pot with water.
  3. Reassemble the pump cover and plastic clamp onto the strainer pot. The pump is now ready to prime.
  4. Open the air release valve on the filter, and stand clear of the filter.
  5. Turn on the switch or time clock.
  6. When water comes out of the air release valve, close the valve. The system should now be free of air and recirculating water to and from the pool.
  7. For 2-speed pumps:
    • Pump should run on high-speed for priming.
    • The pump should not run longer than 8 minutes before priming is achieved.
      Motor Assembly
      Motor Assembly

TROUBLESHOOTING

Problem Possible Cause Corrective Action
Pump failure. Pump will not prime – Air leak, too much air.

Pump will not prime – Not enough water.

Pump stainer gasket is clogged. Pump strainer gasket is defective.

| Check suction piping and valve glands on any suction gate valves. Secure lid on pump strainer pot and be sure lid gasket is in place. Check water level to be sure skimmer is not drawing air.

Be sure the suction lines, pump, strainer, and pump volute are full of water. Be sure valve on suction line is working and open (some systems do not have valves). Check water level to make sure water is available through skimmer.

Clean pump strainer pot. Replace gasket.

Reduced capacity and/or head.| Air pockets or leaks in suction line.

Clogged impeller.

**** Pump strainer clogged.

| Check suction piping and valve glands on any suction gate valves. Secure lid on pump strainer pot and be sure lid gasket is in place. Check water level to be sure skimmer is not drawing air.

Turn off electrical power to the pump. Disassemble (see page 5, ‘Pump Disassembly’)

Clean debris from impeller. If debris cannot be removed, complete the following steps:

  1. Remove left hand thread anti-spin bolt and o-ring.
  2. Remove, clean, and reinstall impeller. Reassemble (see page 6, ‘Pump Reassembly’)

Clean suction trap.

REPLACEMENT PARTS

SuperFlo® High Performance Pump Parts List
Replacement Parts

SINGLE SPEED SUPERFLO MOTORS 12      355621     SCREW ¾-16 X 2¼ HEX HD, 4 req.

1| 355018S| ½ , ¾ HP — (Almond)| 13| 072184| WASHER 3/8 in. S/S, 4 req.
1| 355020S| 1 HP — (Almond)| 14| 355619| O-RING SEAL BRACKET
1| 355022S| 1½ HP — (Almond)| 15| 6020018| O-RING ADAPTER #2-226, 2 req.
1| 355024S| 2 HP — (Almond)| 16| 355030| SEAL DIFFUSER
1| 355026S| 2½ HP — (Almond)| 17| 355334| SCREW #8-32 HEX WASHER HD, 3 req.
DUAL SPEED SUPERFLO MOTORS

1     350088S    ¾ HP 115 VOLTAGE — (Almond)

| 18

18

| 355617

355617

| DIFFUSER – ½ HP DIFFUSER – ¾ HP
1| 355003S    1 HP — (Almond)| 18| 355617| DIFFUSER – 1 HP
1| 356630S    1½ HP — (Almond)| 18| 355618| DIFFUSER – 1½ HP
1| 071320S    2 HP — (Almond)| 18| 355618| DIFFUSER – 2 HP
ENERGY EFFICIENT SUPERFLO MOTORS 18      350170     DIFFUSER – 2½ HP
1| 355008S| ½ , ¾, 1 HP — (Almond)| 19| U30-74SS| HEX HEAD SCREW 3/8 – 16, 4 req.
1| 355010S| 1½ HP — (Almond)| 20| 355043| IMPELLER ½ HP
1| 355012S| 2 HP — (Almond)| 20| 355043| IMPELLER ¾ HP
1| 355014S| 2½ HP — (Almond)| 20| 355067| IMPELLER 1 HP
2| 356012| SEAL PLATE| 20| 355074| IMPELLER 1½ HP
3| 350094| BASE| 20| 355086| IMPELLER 2 HP
4| 350090| CLAMP, RAMP & CAM| 20| 355093| IMPELLER 2½ HP
5| 350091| LID| 20| 355067| IMPELLER 1 HP, 2-SPD
6| 357255| O-RING, LID #2-357| 20| 355074| IMPELLER 1½ HP, 2-SPD
7| 350089| VOLUTE| 20| 355086| IMPELLER 2 HP, 2-SPD
8| 350093| ADAPTER, 2 req.| 21| 355389| SCREW, IMPELLER LOCKING
9| 350092| NUT, 2 req.| 22| 354545S| SEAL SET
10| 192115| O-RING DRAIN PLUG, 2 req.| 23| 355667| BASKET, LARGE
11| 071131| DRAIN PLUG, 2 req.| 24| 350157| KIT UNION SUPERFLO (Items No. 8, 9, 15)

Pump Performance Curves
Pump Performance Curves

1620 HAWKINS AVE., SANFORD, NC 27330 • 919-566-8000
10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • 805-553-5000

WWW.PENTAIRPOOL.COM

All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Pentair Aquatic Systems®, SuperFlo®, Cam and Ramp™ and High Flow™ are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an
affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.

© 2016 Pentair Water Pool and Spa, Inc. All rights reserved. This document is subject to change without notice.
Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals