JH-heater JH-NR10-13A-B Wall Mounted Ceiling Radiant Heater Owner’s Manual

June 5, 2024
JH heater

**JH-heater JH-NR10-13A-B Wall Mounted Ceiling Radiant Heater Owner’s Manual

**

READ AND SAVE THESE INSTRUCTIONS

  • Read all instructions carefully before setting up and operating this unit.
  • This manual is designed to provide you with important information needed to setup, operate, maintain for your radiant heaters.
  • Failure to follow these instructions may damage and/or impair its operation and void the warranty.
    Icon

FOREWORD

Thank you for your trust and support in choosing the Radiant Heater, please read the instructions carefully before operating product.

RADIANT HEATER THEORY

Far-infrared radiant heater is produced by unique design and manufacturing technique.
Adopted special aluminum alloy radiation panel, surface of panel process with special coating, inside of panel embed with heating element, heating element generate and transfer heat to people and objects after power.
The heat is spread in the form of radiation, emitted from radiant panel surface, transferred to people, wall, floor, ceiling, furniture etc, like sunshine.
Radiant heating, will not lead to air convection, air is fresh and clean, to maintain indoor relative humidity and heat distribution, makes sense of natural, fresh, comfortable, like the warmth of sunshine bathing.

PERFORMANCE FEATURES

Comfortable:
No wind, light or odor will be caused during the running of this product, so the indoor air is clean without floating dust.

Energy-saving:
High heat generation efficiency and good heat radiation effect, controlling the temperature intelligently, and saves power and energy.

Reliable:
The indoor temperature can be adjusted freely, free of the limitation of heating season.

Physical therapy:
The heat radiant can change body microcirculation, cell organization under skin producing resonance, clearing the barrier of microcirculation, adjusting and balancing nervous system, promoting metabolism, increasing body physical power. It is very good for people’s health.

WORKING CONDITION

Ambient temperature: -30℃~ +30℃
Rated Voltage: 220-240V~
Rated frequency: 50Hz/60Hz
Relative humidity: less than 95%

INSTALLATION REQUIREMENTS

Qualified installer:

Electrical installation certificate shall be held by professional installation personnel, the installation process should meet the national electrical safety standards.

Installation conditions:

  1. Supply voltage fluctuation range should be within ± 10%, if do not meet, must be revised before installation.
  2. If there is a serious security risk in users’ electricity environment, the installation should be refused, until eliminate the security risks.
  3. Electricity lines should be equipped with earth leakage protection devices and master switch.
  4. Ground wire should be connected to the grounding device on the building, if not, please consult to professional installer, please do not put ground wire to gas pipe, water pipe, lightning rod or telephone grounding wire.

Electrical Parameters

Heater-Ⅲ

Model No. Power(W) Rated Current(A) Voltage(V) Cable length(mm)
JH-NR10-13A/B 1000 4.3 220-240 2000
JH-NR18-13A/B 1800 7.8 220-240 2000
JH-NR24-13A/B 2400 10.4 220-240 2000
JH-NR32-13A/B 3200 13.9 220-240 500
JH-NR40-13A 4000 5.8 380-415 500

Heater-Ⅳ

Model No. Power(W) Rated Current(A) Voltage(V) Cable length(mm)
JH-NR10-14A/B 1000 4.3 220-240 2000
JH-NR18-14A/B 1800 7.8 220-240 2000
JH-NR24-14A/B 2400 10.4 220-240 2000
JH-NR32-14A/B 3200 13.9 220-240 500
JH-NR40-14A 4000 5.8 380-415 500

Heater-Ⅴ

Model No. Power(W) Rated Current(A) Voltage(V) Cable length(mm)
JH-NR10-15A/B 1000 4.3 220-240 2000
JH-NR18-15A/B 1800 7.8 220-240 2000
JH-NR24-15A/B 2400 10.4 220-240 2000
JH-NR32-15A/B 3200 13.9 220-240 500
JH-NR40-15A 4000 5.8 380-415 500

INSTALLATION INSTRUCTION

Spare parts size drawing

INSTALLATION INSTRUCTION

Heater-Ⅲ
INSTALLATION INSTRUCTION

Model No. Dimension A Dimension B Dimension C
JH-NR10-13A/B 600mm 200mm 95mm
JH-NR18-13A/B 1000mm 700mm 95mm
JH-NR24-13A/B 1500mm 1200mm 95mm
JH-NR32-13A/B 2000mm 1700mm 95mm
JH-NR40-13A 2000mm 1700mm /

Heater-Ⅳ
INSTALLATION INSTRUCTION

Model No. Dimension A Dimension B Dimension C
JH-NR10-14A/B 600mm 200mm 95mm
JH-NR18-14A/B 1000mm 700mm 95mm
JH-NR24-14A/B 1500mm 1200mm 95mm
JH-NR32-14A/B 2000mm 1700mm 95mm
JH-NR40-14A 2000mm 1700mm /

Step1: Take out packing of both ends of heater.
INSTALLATION INSTRUCTION

Step2: Installation of adjusting bracket & sliding bracket.
INSTALLATION INSTRUCTION

Step3: Installation of sliding bracket & heater, as arrow points.
INSTALLATION INSTRUCTION

Step4: Fix adjusting bracket into the wall by expansion screws.

Step 5: Installation of two adjusting brackets; make sure lock brackets tight by butterfly hand screw.
INSTALLATION INSTRUCTION

INSTALLATION DIAGRAM

INSTALLATION DIAGRAM

MANUAL FOR REMOTE

Temperature controller parts (Heater-Ⅲ)

Temperature controller parts (Heater-Ⅳ)

LED

LED

remote
MANUAL FOR REMOTE

LED indicate manual

AS aboved pic shows: There are 4 indicate lights in the temperature controller parts, these 4 indicate lights are used to indicate machine’s running level. No.5 is far infrared receiver;
Attention: The No. 1 indicate light has two color state, red and green.

  1. After connected with electrical, but keep turn off heater. You will see all indicate lights not shines , like , please press (ON&OFF BUTTON ) to turn on heater. Please noted:
    Heater default setting runs in 100% power.

  2. Press (POWER BUTTON) to adjust heater running power.

  3. Press (CLOCK BUTTON) to control heater turn off on setting hours.

Power levels
No. 1 indicate light has two color state, red and green.
shines red: No.2 to No 4 lights shows in power setting;
shines green: No.2 to No.4 lights shows in clock setting (time setting).

Icon

INSPECTION ITEMS AFTER INSTALLATION

Items to be checked Situation caused by improperly installation
Is installation stable? The equipment may fall off or shake.
Is heat insulation adequate? Damage objects close to equipment.
Does power voltage same as voltage shown on product nameplate? Equipment

failure.
Does wire connection correct?| Equipment failure.
Does electricity ground connected safely?| There is electricity leakage risk.
Does wiring conform to standard?| Equipment failure or circuit damage.

ATTENTION

Due to thermal expansion and contraction, the heater would make noise when turning on or off.
It’s a normal phenomenon, and won’t make bad affection.

INSPECTION ITEMS FOR COMMISSIONING

  1. Cannot turn on power before finishing all installation works.
  2. All wires connection are correct and firm.
  3. All scattered objects must be removed from radiant heater body.
  4. Connect with power to observe radiant heater working status.

SAFETY PRECAUTIONS

  1. Do not use the same socket together with other appliances, in case of current overload. Make sure the plug and socket good contact.
  2. Please pull plugs out when power off. Be care, do not pull wires by hands.
  3. Please stop power immediately once heaters failure or wires are broken. Users can not repair heaters by themselves. Pls contact authorized servicer for maintenance if heaters failure.
  4. Radiant heater can not be placed directly below the power outlet.
  5. Radiant heater surface temperature is high, must be installed higher than 2.2 meters above ground.
  6. Radiant heater surface can not be covered and can not hang objects on equipment.
  7. The distance between back of radiant heater and roof should be larger than 150mm, can not place objects within 1000mm distance in front of radiant heater, the side should be kept at least 200mm away from the surrounding space.
  8. Must cut off power and wait till equipment surface cool before cleaning, flushed by water is prohibited.
  9. Users can not repair the radiant heater, if equipment failure and need maintenance, please contact authorized servicer.
  10. Do not install and use radiant heaters on areas occur with flammable, explosive, easy to shock.
  11. Please do not insert any metal or foreign objects to inside of radiant heater, to avoid accident or personal injury.
  12. Radiant heater panel surface with high temperature, the surface temperature can reach to 250℃ ~ 380℃, touch is forbidden, beware of scalding accident.
  13. Do not splash water into radiant heater to avoid accidents.

PACKING LIST

No. Name QTY
1 Heater 1 pc
2 Adjusting bracket 4 pc
3 Sliding bracket 2 pc
4 Fastener 1 set
5 Owner manual 1 copy
6 Certification 1 pc

SPECIFICATIONS

Model No. Dimension(mm) Package size(mm) Net weight(kg) Gross weight(kg)
JH-NR10-13A 60018967 695250145 3.7 4.8
JH-NR18-13A 100018967 1095250145 6.2 7.4
JH-NR24-13A 150018967 1595250145 8.8 10.6
JH-NR32-13A 200018967 2095250145 11.4 13.4
JH-NR40-13A 200018967 2095250145 11.4 13.4
JH-NR10-13B 69518967 790250145 4.3 5.4
JH-NR18-13B 109518967 1190250145 6.8 8
JH-NR24-13B 159518967 1690250145 9.4 11.2
JH-NR32-13B 209518967 2190250145 12.2 14.2
Model No. Dimension(mm) Package size(mm) Net weight(kg) Gross weight(kg)
--- --- --- --- ---
JH-NR10-14A 60021570 695275140 3.6 4.8
JH-NR18-14A 100021570 1095275140 6.1 7.5
JH-NR24-14A 150021570 1595275140 8.8 10.8
JH-NR32-14A 200021570 2095275140 11.6 13.8
JH-NR40-14A 200021570 2095275140 11.6 13.8
JH-NR10-14B 69521570 790275140 4.3 5.5
JH-NR18-14B 109521570 1190275140 6.8 8.2
JH-NR24-14B 159521570 1690275140 9.5 11.5
JH-NR32-14B 209521570 2190275140 12.3 14.5
Model No. Dimension(mm) Package size(mm) Net weight(kg) Gross weight(kg)
--- --- --- --- ---
JH-NR10-15A 60018967 695250145 3.7 4.8
JH-NR18-15A 100018967 1095250145 6.2 7.4
JH-NR24-15A 150018967 1595250145 8.8 10.6
JH-NR32-15A 200018967 2095250145 11.4 13.4
JH-NR40-15A 200018967 2095250145 11.4 13.4
JH-NR10-15B 69518967 790250145 4.3 5.4
JH-NR18-15B 109518967 1190250145 6.8 8
JH-NR24-15B 159518967 1690250145 9.4 11.2
JH-NR32-15B 209518967 2190250145 12.2 14.2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals