FLUKE PTi120 Pocket Thermal Imager User Guide
- June 5, 2024
- FLUKE
Table of Contents
FLUKE PTi120 Pocket Thermal Imager
LIMITED WARRANTY AND LIMITATION OF LIABILITY
-
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller and does not apply to fuses, disposable batteries, or to any product which, in Fluke’s opinion, has been misused, altered, neglected, contaminated, or damaged by an accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error-free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if the product is purchased through a Fluke authorized sales outlet or the Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when a product purchased in one country is submitted for repair in another country. -
Fluke’s warranty obligation is limited, at Fluke’s option, to refund the purchase price, free of charge repair, or replacement of a defective product that is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to the Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid, and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). -
This Warranty Is Buyer’s Sole And Exclusive Remedy And Is In Lieu Of All Other Warranties, Express Or Implied, Including But Not Limited To Any Implied Warranty Of Merchantability Or Fitness For A Particular Purpose. Fluke Shall Not Be Liable For Any Special, Indirect, Incidental, Or Consequential Damages Or Losses, Including Loss Of Data, Arising From Any Cause Or Theory.
-
Since some countries or states do not allow the limitation of the term of an implied warranty or the exclusion or limitation of incidental or consequential damages, the limitations, and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Introduction
Limitelimited Wd Warrantyarranty And Limited Limitation Of Liabilitytion Of Liabilitythe Fluke Pti120 (The Product Or Imager) Is A Handheld, Infrared Imaging Camera For Use In Many Applications. These Applications Include Equipment Troubleshooting, Preventive And Predictive Maintenance, Building Diagnostics, And Research And Development. The Product Shows Thermal Images On A High-visibility, Industrial-quality Lcd Touch Screen. The Product Saves Images To Internal Memory Which Can Be Transferred To A Pc Through A Direct Usb Connection To The Pc Or By Wireless Transfer To A Pc Or Mobile Device. The Product Includes Fluke Connect Desktop Software. Fluke Connect Is A High- performance, Professional Software Suite For Quality Analysis And Reporting.
Contact Fluke
- Fluke Corporation operates worldwide. For local contact information, go to our website: www.fluke.com To register your product, view, print, or download the latest manual or manual supplement, go to our website. Fluke Corporation
- P.O. Box 9090
- Everett, WA 98206-9090
- +1-425-446-5500
- fluke-info@fluke.com
Safety Information
General Safety Information is in the printed Safety Information document that ships with the Product and at www.fluke.com. More specific safety information is listed where applicable.
Product Familiarization
Table 1 lists the features of the Product.
IR-Fusion ä Technology | Image annotations |
---|---|
Visible | Asset Identification |
Fullscreen IR Autoblendä | Fluke Connect desktop software |
Controls and Connections
Table 2 shows the controls and connections of the Product.
Item | Description | Item | Description |
---|---|---|---|
LCD touch screen (display) | G | Hand strap | |
Image capture button | H | LED torch/flashlight | |
Fluke Connect indicator | I | Infrared camera lens | |
D | Power button | J | Visual light camera lens |
E | USB port | K | USB cable |
F | Connector cover |
Touch Screen (Display)
The touch screen is the user interface of the Product. The touch screen has a backlight for work in dimly lit spaces. Table 3 shows the default information on the screen of the Product. Table 3. Display
Item | Description | Item | Description |
---|---|---|---|
Center point marker | H | Status bar | |
Center point temperature | I | Background temperature | |
Scale | J | Emissivity value | |
D | Temperature range upper value | K | Time |
E
| Range bar
The range of colors in the palette mapped to a certain range of temperatures
| ****
L
| ****
Date
F| Center point color in relation to the palette| M| Battery status
G| Temperature range lower value
Basic Operation
Turn On and Off the Product
- Before you use the Product for the first time, charge the battery for a minimum of 1.5 hours. See Charge Batteries. To turn on or turn off the Product, push and hold O for 2 seconds. To keep the Product on and turn the display off, push O for seconds.
- There is no visible way to tell if only the display is off or if the Product is off. To maximize the life of the battery, use the LCD Time Out and Power Off features. See Table 9 for more information about how to set these features.
- All thermal imagers need sufficient warm-up time for accurate temperature measurements and best image quality. Warm-up time can vary by model and environmental conditions. Although most imagers are fully warmed up in 3 minutes to 5 minutes, wait a minimum of 10 minutes if the most accurate temperature measurement is important to your application. When you move an imager between environments with large differences in ambient temperature, allow for additional adjustment time.
Capture Image
To capture an image
- In the Device Settings menu, set the Distance to the target.
- Focus on a target.
- Push and release the Image Capture button or double tap on the display to capture and freeze the image.
- The image is in the memory buffer for you to save or to add an asset ID tag or note to the image. To add an asset ID tag to the image, see Asset Identification (Asset ID). To add a note to an image, see Notes. Note
- Asset ID tags and notes can be saved with images captured in .is2 file format only. To select the .is2 file format, see Device Settings Menu.
Save Images to PC
To save images to a PC with the USB cord:
- Turn on the Product.
- Connect one end of the USB cord to the USB port on the Product and the other end to a USB port on a PC.
- The PC recognizes the Product as an external memory storage device.
- On the PC:
- Save the images to a directory.
- Eject the Product from the PC.
- Remove the USB cable from the PC and the Product.
Menu Controls
- To use the menus to change and view settings:
- Tap the display to open the main menu.
- Tap an icon on the main menu to open a submenu. See Table 5.
- The background of the selected icon changes to yellow.
- Tap a menu control to set and change options. See Table 4.
- To close a submenu and return to live camera mode, tap the submenu icon again. Table 4 lists the menu controls.
Main Menu
Table 5 lists the secondary menus available in the Main Menu.
Item | Secondary Menu | Option | Function |
---|---|---|---|
I | Memory | Select to review, edit, and delete captured |
images. See Memory Menu (Memory Gallery).
| A| Image| IR- Fusion| Set the IR-Fusion level. See Image
Menu.
| P| Palette|
D| M| Display|
Display Menu.
E
| ****
L
| ****
Light
| Torch| Use the toggle switch to turn on or off the torch (flashlight).
Backlight| Use the slider bar to set the brightness level of the
display.
F| S| Settings|
Image Menu
- The IR-Fusion slider bar sets the Product to take images from full visible light mode to full IR-Fusion mode. Use a blend between visible light mode and IR-Fusion to view an object with some temperature overlays.
- To adjust the IR-Fusion level
- Tap A.
- Use the slider bar to set the IR-Fusion level.
- Alternatively, you can adjust the IR-Fusion level in camera mode. Touch the display and slide left to right to increase the level of IR-Fusion. Slide from right to left to decrease the IR-Fusion level.
Level/Span
Level and Span are values within the total range of temperature. The level is the temperature level to view within the total range of temperatures. Span is the span of temperatures to view within the total range of temperatures. With Level/Span set to Auto, the Imager sets Level/Span based on the total temperature range. With Level/Span set to Manual, you can move the thermal span up or down within the total temperature range. Table 6 shows Level and Span in Manual edit mode. Table 6. Level and Span Settings.
To access manual Level/Span mode
- From the menu: Select S > IR Settings> Level/Span > Manual> Edit Level / Span.
- From the screen: tap Auto or tap the scale.
- To adjust Level/Span mode:
- Move the top and bottom of the span box to adjust the range.
- Slide the box to adjust the level.
To automatically rescale: In Manual mode tap Manual. The camera will automatically adjust the scale and return to Manual mode.
Palette Menu
The standard palettes offer an equal, linear presentation of colors that allow for the best presentation of detail. The palettes are Grayscale, Ironbow, High Contrast, Amber, Hot Iron, and Blue-Red. To change the palette of an image
- Tap P.
- Tap on a palette thumbnail.
- A checkmark shows on the selected palette. The color and temperature range bar on the display changes according to the selected palette.
Display Menu
Use the Display menu to set which features to show on the display. To show the Fluke logo on the display, see Device Settings Menu. Table 7 lists the options in the Display menu.
Option | Description |
---|---|
Spot Temp (Min/Max) | Turn on or off the maximum and minimum temperature |
indicators on the display. The Spot Temperatures are floating HI and LO
temperature indicators that move on the display as the temperature
measurements of the image fluctuate.
Center Point| Turn on or off the Center point marker and Center point
temperature.
Scale| Turn on or off the Scale.
Status Bar| Turn on or off the Status bar
Settings Menu
Table 8 lists the options in the Settings menu.
Option Menu | Description |
---|
D Scan Asset ID
Scan QR Code or Barcode
| Assign images to an asset.
Scan a QR code or barcode attached to an asset or manually enter an asset identification. See Asset Identification (Asset ID).
E IR Settings| Set the infrared settings. See IR Settings
Menu.
C Device Settings| Set user preferences and view information about
the Product. See
Device Settings Menu.
Device Settings Menu
Table 9 lists the options in the Device Settings menu.
Option Menu | Option | Description |
---|
File Format
| ****
IS2
| Saves images as a .is2 file.
Choose the .is2 file format when image modification and maximum resolution is needed.
The .is2 file format consolidates the infrared image, radiometric temperature data, visible image, notes, and tags into a single file. To customize or separate the visible and infrared images, use Fluke Connect desktop software.
Use to assign an asset ID tag or to flag an asset image.
JPEG
| Saves images as a .jpg file.
Choose the .jpg file format for images with the smallest file size, where modification is not needed, and image quality and resolution are not as important.
Units|
Distance
|
Units| Sets the units to use to measure distance. This option is not
available in all countries.
Change Filename
| Filename Prefix| Changes the default filename that starts with IR_ to
a different 3-character prefix.
Reset Filename Numbers| Resets the file number to 00001.
Auto Off
| LCD Time Out| Sets the time before the display automatically turns
off.
Power Off| Sets the time before the Product automatically turns off.
Date|
Time|
Fluke Logo| NA| Shows or hides the Fluke logo on the display.
Option Menu| Option| Description
---|---|---
Language|
Decimal Separator|
Reset to Factory Defaults| NA| Erases user-set preferences and restores
the factory default settings.
Certificates| NA| Shows information about the wireless certificates of
the Product.
Licenses| NA| Shows information about the Open Source Software Licenses
used to develop the Product.
Version| NA| Shows information about the version of the Product.
IR Settings Menu
Table 10 lists the options available in the IR Settings menu.
Option | Description |
---|
Level / Span
| Select the level and span mode:
Auto – Automatically adjusts Level/Span.
Manual – Manually adjust Level/Span with slider. Select Edit Level / Span.
Emissivity| Select an emissivity value from a list of common materials. Use the scroll bar to see all of the options. See Emissivity Adjustment.
Background
| Changes the background temperature to compensate for reflected background temperature.
Very hot objects or very cold objects can affect the apparent temperature and measurement accuracy of the target, especially when surface emissivity is low. Adjust the reflected background temperature to improve the accuracy of the measurement.
Transmissivity| Changes the values used to calculate the temperature based on the transmission percentage of the infrared-transparent window (IR window). See Transmissivity.
Emissivity Adjustment
All objects radiate infrared energy. The actual surface temperature and emissivity of the target affects the quantity of energy radiated. The Imager senses the infrared energy from the surface of the target and uses the data to calculate an estimated temperature value. Many common materials such as wood, water, skin, cloth, and painted surfaces, including metal, radiate energy well and have a high emissivity factor of ≥90 % (or 0.90). The Imager measures temperatures accurately on targets with high emissivity. Shiny surfaces or unpainted metals do not radiate energy well and have a low emissivity factor of 0.60. For the Imager to calculate a more accurate estimate of the actual temperature of targets with a low emissivity, adjust the emissivity setting.
Warning
To prevent personal injury, see emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. Set emissivity as a direct value or from a list of emissivity values for some common materials. If the emissivity value is <0.60, a caution shows on the display. Surfaces with an emissivity of <0.60 make it difficult to determine reliable and consistent actual temperatures. The lower the emissivity is the greater the potential of error is when the Imager calculates the temperature measurement because more of the energy reaching the camera is specified as background temperature. This is also true even when adjustments to the emissivity and reflected background adjustments are performed properly.
Transmissivity
When you do infrared inspections through IR windows, not all of the infrared
energy emitted from the target is transmitted through the optical material in
the window. If you know the transmission percentage of the window, adjust the
transmission percentage in the Imager or in Fluke Connect desktop software to
improve the accuracy of the measurement.
When you do not do infrared inspections through an IR window, set
Transmissivity to 100 % to disable the correction percentage.
Memory Menu (Memory Gallery)
When the memory is 90 % full, a yellow message bar shows at the top of the display. When the memory is full, the message bar changes to red. To capture more images when the internal memory is full, save the images to an external memory device and delete the images from the Product. Images are saved to the internal memory storage. Use the Memory menu to view, edit, or delete images. Images are organized by the date they were captured with the newest images at the top. When additional information has been saved with an .is2 file, an icon shows with the preview file. The icons are:
View Image
To open an image in fullscreen mode
- Tap I.
- If needed, touch the display and slide up or down to view all the images.
- Tap on a thumbnail or preview image to view the image fullscreen.
- A toolbar briefly opens on the top of the display. Tap on the image to open or close the toolbar.
- Notes are stored with the image so you do not need to collate multiple files later. To add, edit, and delete notes, use the keyboard that opens on the display.
- Notes with Single Image
To add, edit, or delete a note:
- Open an image in fullscreen mode.
- Tap N. If needed, tap first.
- If no notes are saved with the image, a keyboard opens on the display.
- Use the keyboard to enter a message.
- Tap Save.
- If a note is saved with the image, a list of notes opens on the display.
- To add another note to the image, tap , use the keyboard to add the new note, and tap Save.
- To edit a note, tap on a note, use the keyboard to edit it, and tap Save. If needed, scroll down to see all the notes.
- To delete a note, tap on a note, tap Delete, and tap Delete again.
Add a Note to Multiple Images
To add a note to multiple images at the same time
- Select I > > Add a Note to Multiple Images.
- The display returns to the memory gallery.
- Tap an image to select it. Tap an image again to clear the selection.
- The border and filename text color change to yellow.
- Repeat for each additional image.
- Tap Add Note.
- A keyboard opens on the display.
- Use the keyboard to enter a message.
- Tap Save.
Delete Images
To delete images, do the corresponding procedure below for the desired action.
- To delete only one image:
- Open an image in fullscreen mode.
- Tap T. If needed, tap first.
- Tap Delete.
Delete Multiple Images
To delete multiple images at the same time
- Select I > > Delete Multiple Images.
- The display returns to the memory gallery.
- Tap an image to select it. Tap an image again to clear the selection.
- The border and filename text color change to yellow.
- Repeat for each additional image.
- Tap Delete Images.
- Tap Delete.
- Delete All Images
- To delete all of the images at the same time:
- Select I > > Delete All Images.
- Tap Delete.
Asset ID
Use the memory gallery toolbar to add or remove an asset ID from an image that is saved in memory. See Asset Identification (Asset ID). To add an asset ID to an image:
- Open an image in fullscreen mode.
- Tap D.
- Assign an asset ID. See Asset Identification (Asset ID).
- To remove an asset ID from an image:
- Open an image in fullscreen mode.
- Tap the asset ID that looks on the display.
- Tap Remove.
The display returns to the image in fullscreen mode, and the asset ID does not show on the display.
Asset Identification (Asset ID)
Use Asset ID to save and organize images by asset like a motor or electrical panel. Use a barcode, QR code, or other unique identification like a tag to attach to images. When in camera mode, the asset ID shows on the display and looks like . Asset IDs need to be unique to each asset. Assign Asset ID Tag with a QR Code or Barcode To save images to an asset with a QR code or barcode:
-
Select S > Scan Asset ID.
-
Focus a QR code or barcode in the white box on the display.
-
When the Product detects a barcode has been scanned, tap Use Barcode or Use QR Code. If the Product cannot detect a barcode or QR code, manually enter a unique asset ID. See Assign Asset ID Tag Manually.
-
The display returns to camera mode, and the barcode or QR code number shows on the display.
-
Capture an image.
-
Assign Asset ID Tag Manually
-
To manually enter a unique asset ID:
-
Select S > Scan Asset ID.
-
Tap Manual Entry.
-
A keyboard opens on the display.
-
Enter a unique asset identification.
-
Tap Save.
-
The display returns to camera mode, and the asset ID shows on the display.
-
Exit an Asset ID Tag
-
To exit out of an asset ID and save images without an asset ID:
-
Tap the asset ID that looks like on the display.
-
Tap Exit Asset ID xxxxx (where xxxxx is the name of the asset ID).
-
The display returns to camera mode, and the asset ID does not show on the display.
Assign a Different Asset ID Tag -
To exit out of an asset ID and save images with a different asset ID:
-
Tap the asset ID that looks like on the display.
-
Tap D Scan New Asset ID.
-
Assign a new asset ID. See Asset Identification (Asset ID).
-
Fluke Connect Desktop Software Fluke Connect desktop software for a PC is available to use with the Product and contains features to analyze images, organize data and information, and make professional reports.
-
Use Fluke Connect software to:
-
Review notes, asset IDs, and flags.
-
Export IR and visible images.
-
Edit .is2 image files.
-
Update the firmware with new features.
-
Download Fluke Connect Software Go to https://www.fluke.com/en-us/support/software-downloads/software-for-fluke-infrared-cameras.
-
On the website, follow the instructions to download the software to the PC.
-
On the PC, follow the instructions to install Fluke Connect software. (Administrator privileges are required for the installation.)
-
Restart the PC when installation is complete.
-
Update Firmware
-
On the PC, open Fluke Connect software.
-
Connect one end of the USB cable to your PC and the other end of the USB cable into the
-
Product.
-
Windows automatically installs the device driver for use with the Product. Fluke Connect software recognizes the connection with the Product.
-
On the PC:
-
Select Yes if prompted to download a firmware update file onto the PC.
-
Select the Product from the list on the left.
-
Select Yes if prompted to download a firmware update to the Product.
-
On the Product, tap Ok.
-
To complete the firmware update, the Product turns off.
-
To use the new firmware, turn on the Product.
Maintenance -
The Product requires minimum maintenance.
-
Clean the Case
-
Clean the case with a damp cloth and a weak soap solution. Do not use abrasives, isopropyl alcohol, or solvents to clean the case.
-
Lens Care
-
To prevent damage to the infrared lens:
-
Carefully clean the infrared lens. The lens has a delicate anti-reflective coating.
-
Do not clean the lens too vigorously because this can damage the anti-reflective coating.
-
To clean the lens
-
Use a pressurized can of air or a dry nitrogen-ion gun, if available, to blow off the particulates from the lens surface.
-
Soak a lint-free cloth in a commercial lens cleaning liquid that contains alcohol, ethyl alcohol, or isopropyl alcohol.
-
Squeeze the cloth to remove excess liquid.
-
Wipe the lens surface in one circular motion and discard the cloth.
-
If needed, repeat with a new lint-free cloth.
-
Battery Care
-
Caution
-
To prevent damage, do not expose Product to heat sources or high-temperature environments such as an unattended vehicle in the sun.
-
To get the best performance from the lithium-ion battery:
-
Do not charge the Product for more than 24 hours as reduced battery life may result.
-
Charge the Product for at least 1.5 hours every six months for maximum battery life. Without use, the battery will self-discharge in approximately six months.
-
Charge Batteries
-
To prevent damage to the Product:
-
Always operate in the specified temperature range.
-
Do not attempt to charge the batteries in extreme cold environments.
-
Do not use a USB charger that supplies >5 V (±5%).
Do not incinerate the product.
Make sure that the Product is near room temperature before you charge the battery. See the charging temperature specification. Do not charge in hot or cold areas. When you charge in extreme temperatures, battery capacity may be decreased. Before you use the Product for the first time, charge the battery for at least 1.5 hours. The battery status shows on the five-segment charge indicator.
- Connect one end of the USB cord to the USB port on the Product and the other end to a USB port on a PC.
- Charge until the charge indicator, bz, on the display does not flash.
- Disconnect the USB cable when the battery is fully charged.
- Radio Frequency Data See Table 9 for instructions on how to access digital copies of the Certificate IDs on the Product.
- To view the Radio Frequency Data Class B Instruction Sheet, visit http://us.fluke.com/usen/support/manuals
Specifications
Complete specifications are at www.fluke.com. See the PTi120 Product Specifications.
References
- Fluke 1AC II Non-Contact Voltage Tester | Fluke
- Fluke Corporation: Fluke Electronics, Calibration and Networks
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>