HydroTab ASM-01049 3DHC Controller User Manual

June 10, 2024
HydroTab

HydroTab ASM-01049 3DHC Controller

Disclaimer
The interceptor units are also steering equip-ment and it is the sole responsibility of the nav-igator-operator to ensure that, at any point, any problem that will alter the boat’s course, rising from malfunction of interceptors, should be dealt immediately by the operator. At no circumstanc- es, fault of our interceptor equipment leading to any kind of accident, creates liability for the manufacturer.

Trademark Notice
Hydrotab is a registered trademark of Olympic Engineering Ltd, Greece. All other trademarks, trade names or company names referenced here-in are used for identification only and are proper-ty of their respective owners.

Patent Notice
The Hydrotab products are protected by patents and industrial design patents, patents pending or design patents pending.

Declaration of conformity
This product conforms to the following Electromagnetic Compatibility (EMC) regulations and standards for use in marine environments. CE EN 60945

Technical information and Documentation
The technical information provided in this doc-ument was accurate and correct at the corre-sponding production time of the Hydrotab inter-ceptors. Our operating principal for improving the manufactured product, may lead to changes regarding its specifications without prior notice. Liability will not be accepted for any inaccuracy considering the product and the user manual.

Fair use statement
This manual can be printed or copied for your own use only. Copies should not be provided to third parties and manual should not be commer-cialized.

Product Disposal
Waste removal of this product must be according to the Waste Electrical and Electronic Equipment (WEEE) Directive.

Product Registration
Please register your product online in order the warranty to be valid.

Controller and Air Unit Installation

3DHC Controller Installation

  1. Use 66mm holesaw to create a hole in the desired position.
  2. Remove the cap.
  3. Mount the panel with the corresponding screws.
  4. Place the cap ntil it is firmly closed.

Air Unit Installation

  1. Place the unit in the desired position at the inner of the boat and make the marks that will be used to drill the holes for the mounting scews.
  2. Open the 4 holes (Figure 2), and mount the AIR Unit by tightening firmly the screws.
    NOTE: Please be noted, that the AIR Unit it is recom-mended to be mounted on a flat surface, according to Figure

Installation Schematic overview – Single Air Unit (ASM-01051) with One 3DHC ControllerHydroTab-ASM-01049-3DHC-Controller-fig-8

Installation Schematic overview – Single Air Unit (ASM-01051) with Two 3DHC ControllerHydroTab-ASM-01049-3DHC-Controller-fig-9

Installation Schematic overview – Double Speed Air Unit (ASM-01086) with One 3DHC ControllerHydroTab-ASM-01049-3DHC-Controller-
fig-10

Installation Schematic overview – Double Speed Air Unit (ASM-01086 )with Two 3DHC Controller

THE 3DHC ControllerHydroTab-ASM-01049-3DHC-Controller-
fig-12

Malfunction indication

 |
---|---
BLINKING LED| MALFUNCTION
1st green on the left| Left interceptor does not teturn
1st green on the left| Right interceptor does not teturn
2nd green on the left| Left interceptor does not extend
2nd green on the left|

The 3DHC controller operation
Interceptors operate when voltage comes from the ignition. When there is no voltage from the ignition, system does not work.

System Reset – Retracting
The system resets and interceptors retract automatically:

  • On engine start
  • On engine stop
  • On simultaneously pressing the UP+ DOWN buttons for 1 second.

Note: During reset process controller LEDs are flashing.
Night and day mode : The indication brightness changes by pressing simultaneously the buttons LEFT + RIGHT for 1 second.

Memory

Setting the desired trim angle
You may save the desired trim angle for the cruising speed. Just manually adjust the position and then press simultane-ously any diagonal press buttons for about 3 econds. This po-sition of trim tabs is stored in 3DHC memory and the power-on led is flashing to confirm the setting. switch of the boat.

Whenever the user presses instantaneously two diagonal press buttons, the trim tabs get the preset position.
The saved position is stored even after switching off the main switch of the boat.

Maintenance

Check connectors for corrosion or liquid pollution. Check in regular intervals the condition of the sacrifice anodes. Below 50% in volume, anodes must be replaced. When the boat is out of the water (end of season):

  • a. extend the blades
  • b. spread the decalcifying liquid with a brush
  • c. let it for 15-20 min
  • d. wash out with clean water
  • e. r etract the blades

Every two years remove the cover and clean the inside of the units, using water pressure. Every three years check the springs condition.

THE 3DHC Controller Functions

EMERGENCY RETRACTING
Press the A + C buttons simultaneously for 1 second.

NIGHT AND DAY MODE
The indication brightness changes by pressing simulta-neously the B + D buttons for 1 second.

NTERCEPTOR POSITION MEMORY

  • Press B + C buttons simultaneously until the red led E blinks, to save the interceptor position in the memory.
  • Next time you press B + C simultaneously for 1 second, the interceptors will be extended automatically in the previous memorized position.
  • If you save a new position in memory, automatically the previous position is cancelled.

3DHC Controller Adaption

The controllers included in packaging, are pre-adjusted.

The instructions of this page must be executed only by authorised technicians and only in case of:

  • Controller replacement with a new one after failure
  • Installation of a secondary controller that does not included in the initial set (Flybridge)

To open the 3DHC Controller

  • Remove the screw.
  • Find the switch and adjust as shown

Electrical Diagram

SYMBOL PART No DESCRITION
C1 PNE-00017 VALVE COIL
C2 PNE-00017 VALVE COIL
C3 PNE-00017 VALVE COIL
C4 PNE-00017 VALVE COIL
R43   RELAY 12 OR 24V
F2   FUSE 3A

ATTENTION: To avoid voltage drop use the right cable size.

AIR UNIT POWER CABLE SIZE

DISTANCE FROM BATTERY| CABLE SIZE
up to 2.5m| 2 x 2.5mm
up to 4m| 2 x 4mm
up to 6m| 2 x 6mm
up to 10m| 2 x 10mm

WARNING: Advise the fusing table and ensure that you apply

Pneumatic Diagram

HydroTab-ASM-01049-3DHC-Controller-fig-19

SYMBOL PART No DESCRITION NOTES
C1 PNE-00017 COIL STARBOARD RETRACT
C2 PNE-00017 COIL STARBOARD EXTEND
C3 PNE-00017 COIL PORT RETRACT
C4 PNE-00017 COIL PORT EXTEND

Contact

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HydroTab User Manuals

Related Manuals