- Physical Dimensions
- Key Electrical Safety
- Electrical Information
- Installation Safety
- Protection from Injury During Installation
- System Planning and Specification
- Controlling Smart PXL Dots with ENTTEC OCTOs
- Attaching Smart PXL Dots & Accessories to a Surface or Structure
- Cleaning
- Part Codes & Ordering Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Smart PXL 40 Dot High-Resolution Smart 40mm RGB Pixel Dots
Installation Guide
ENTTEC Smart PXL 40 Dot High-Resolution Smart 40mm RGB Pixel DotsRobust and
reliable, ENTTEC’s high-resolution, individually addressable SMART PXL Dots
are designed and made in Australia from marine-grade aluminum to withstand the
harshest of environments.
Easy to install and configure into any conceivable shape, SMART PXL Dots
create spectacular, crisp lighting effects while adding a stylish design
element to your venue or installation choice between default options and
custom lengths.
Engineered to take any architectural, commercial, or entertainment project to
the next level, the SMART PXL range has been created by lighting professionals
for lighting professionals.
FEATURES
- Auto-addressing to ensure fast commissioning
- 16-bit control for ultra-smooth dimming or option for 8-bit control (only with ENTTEC pixel controllers).
- 125mm default pixel pitch (customizable; min/max length: 125mm/2000mm).
- Default string – 20 dots with premium IP-rated connectors at each end.
- This product requires an external DC power supply and data source for operation.
Physical Dimensions
Note: Lenses are non-removable & recommended in the absence of protective
measures against external impact in installation.
Smart PXL 40 Dot – No Lens (73010) Smart PXL 40 Dot – Dome Lens
(73011) Smart PXL 40 Dot – Flat Clear Lens (73012) Connector
All ENTTEC Smart PXL Dot accessories are built using the same cabling and
connectors as the Smart PXL Dots themselves and feature industrial-grade heat
shrink to provide additional durability to each connector.
Smart PXL – 2m Male Cable – 24v (73017)
Used as a convenient method to connect your Smart PXL Dot’s output to a
connection block or other device without the need to terminate an Amphenol AT
series connector on site. Smart PXL – 2m Female Cable – 24v (73018)
Used as a convenient method to connect your Smart PXL Dot strings to a
connection block or other device without the need to terminate an Amphenol AT
series connector on site. Smart PXL – Power Injector – 24v (73019)
Used as a convenient method to increase the number of Smart PXL Dots per chain
by up to 76 (at 125mm pitch) by combatting voltage drop and injecting up to
10A of power. The power injector accessory features reverse polarity and
transient voltage protection. Smart PXL – 2m Extension – 24v (73020)
Used as a convenient method to extend the distance between each Smart PXL Dot
string. (Never exceed the cable lengths defined within this guide. Smart PXL
– Termination End Cap (73015)
The Smart PXL Termination End Cap should be attached at the end of a chain of
Smart PXL DOTs to protect the final female Amphenol AT series connector from
short-circuiting and corrosion in wet conditions. This can be secured to a
surface using an m5 screw or bolt. Cable Core Identification Chart – 24v
Each Smart PXL string is comprised of 3 cores, the pinout is as follows:
Cable color / AWG size | Function | Pin on Amphenol Connector |
---|---|---|
Black / 16AWG | 0V | 1 |
Black / 20AWG | Data | 2 |
Black + White stripe / 16AWG | 24V DC + | 4 |
Each accessory is comprised of 3 cores, the pinout is as follows:
Cable color | Function | Pin on Amphenol Connector |
---|---|---|
Black | 0V | 1 |
White | Data | 2 |
Red | 24V DC + | 4 |
ENTTEC recommends the use of cable ferrules when connecting non-tinned cable. Check and respect all directions and warnings given within this installation guide before specifying, installing, and operating a Smart PXL Dot system. If you are unsure or still have any questions about how to install or operate this product safely, please contact your ENTTEC supplier or speak with ENTTEC directly.
Key Electrical Safety
- This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
- This device can be damaged by excess voltage. The installation of an overvoltage protection device on the electrical system may reduce the risk of damage.
- Provide a means of locking out AC mains power to the installation to be shut down and made impossible to reapply accidentally.
- The use of an adequate RCBO along the main power inlet for your installation is recommended.
- Before applying power to the installation, check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices and factor in overhead.
- Isolate the installation from power immediately if Smart PXL Dots, accessories power cables, or connectors is in any way damaged, defective, shows signs of overheating, or are wet (if not an IP65 component).
- Do not exceed the maximum numbers of Smart PXL Dots and accessories that can be connected and the maximum cable lengths specified in this guide and other product documentation.
- To reduce the risk of fire or electrical faults do not exceed the ratings and limitations defined in the product datasheet or this guide.
- Do not hot swap Smart Pixel strings or accessories.
- Shut down power to the installation during cleaning in addition to when the system is not in use.
Electrical Information
- This device operates on DC power and excludes an earth connection.
Installation Safety
- Do not bend the Smart PXL 40 cable into a curve of less than a 30 mm radius.
- Do not over-stretch cabling sections of your Smart PXL 40 Dots.
- Do not operate the Smart PXL Dots if the ambient temperature exceeds 50° C (122° F).
- The Smart PXL Dots are convection cooled, ensuring sufficient airflow can reach each dot to allow heat to be dissipated.
- Do not cover or enclose Smart PXL Dots without a suitable and proven method of dissipating heat.
- To contribute to an optimum operating temperature, where possible keep this device out of direct sunlight.
- Do not modify the Smart PXL Dots system in any way.
- Follow all steps in the installation guidelines section of this document.
Protection from Injury During Installation
- Always use suitable personal protective equipment when installing ENTTEC products.
- When installing the Smart PXL Dots above ground level, ensure that the installation hardware and supporting structure can hold at least 10 times the weight of all the devices they support.
- In an overhead installation or where the Smart PXL Dots system may cause injury if it falls. Block access below the work area and work from a stable platform whenever installing, servicing, or moving the Smart PXL Dots system.
- Once installation is completed, check that all hardware and components are securely in place and fastened to supporting structures.
System Planning and Specification
Before planning or installing your system, ensure you are familiarized with
all key information within this guide and other relevant ENTTEC documentation.
If you are in any doubt about system safety, or you plan to install ENTTEC’s
Smart PXL Dots in a configuration that is not covered within this guide,
contact ENTTEC or your ENTTEC supplier for assistance.
ENTTEC’s Return to Base warranty for this product does not cover damage
caused by inappropriate use or application or modification to the product.
The first step of planning an installation is to determine the pixel pitch and
total quantity of Smart PXL 40 dots required. Use the product datasheet to
determine the light output and pixel pitch your installation requires before
beginning your system design.
Key Safety & Functional Limits
Given the versatility and flexibility of the Smart PXL 40 Dot system, it’s
imperative that the system layout stays within the limits defined within this
document. If two or more different limits apply to a configuration, you must
always follow the lowest.
The system design and installation must respect the key safety and functional
limits defined within this guide.
These limits are:
Power Draw | Current Throughput per string (10A max) |
---|---|
Voltage Drop | Control Channel Availability |
Voltage Drop
The longer the cable distance from the power source to each dot the more
voltage is dropped. Significant voltage drop can result in lower brightness
and in more extreme cases color shift.
This is an important consideration for Smart PXL installations with custom
pixel pitch and can inform the quantity of dots per string between power
injections.
If cable length can be reduced across your installation, this is recommended.
ENTTEC recommends a maximum voltage drop of 3v (12.5%) on a 24v Smart PXL 40
Dot string before power injection is required.
If you are concerned about voltage drop and the impact on your installation,
contact the ENTTEC team or your reseller.
Maximum Smart PXL 40 Dot Chain Length
Maximum chain length is determined by voltage drop, power consumption (10A max
throughput), and control channel availability.
By using ENTTEC’s Smart PXL Power Injector 24v accessory (SKU: 73019) to
inject power from additional PSUs, the impact of voltage drop and power
consumption can be removed leaving control channel availability as the only
limiting factor.
Below table of recommended maximum dots per chain at various pitch lengths
with the following assumptions:
- Maximum power output – all control channels at max value
- Constant pitch length
- Sufficient controlling channel (refer to respective controller datasheet to calculate control channel limit)
- 1 pair of Amphenol connectors every 10 dots
- 10A 240W power supply re-injection
Pixel Pitch (mm) | 125 | 200 | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 |
---|
Maximum dots per chain
| 81| 66| 49| 40| 36| 32| 29| 28| 26| 24| 23
Maximum dots per chain with 1 Smart PXL Power Injector (73019) used after
reaching chain limit.| 162| 132| 98| 80| 72| 64| 58| 56| 52| 48| 46
Maximum dots per chain with 2 Smart PXL Power Injector (73019) used after
reaching chain limit.| 243| 198| 147| 120| 108| 96| 87| 84| 78| 72| 69
Add more Power Injector accessories to extend the chain.
Max dot per chain between power injectors is constant.
Check controlling channel limit
Connection to a 24V DC PSU
In a Smart PXL 40 installation, one or more 24V DC external PSUs (Power Supply
Units) are required to provide power to each chain of Smart PXL Dots if your
control method doesn’t contain an integrated PSU.
Your power supply should be located as close as physically possible to the
beginning of the chain of Smart PXL Dots to minimize the effect of voltage
drop.
For optimum performance and to reduce the impact of voltage drop, ENTTEC
recommends the use of multiple smaller 24v power supplies at the beginning of
each run of Smart PXL Dots, instead of a low quantity of high-capacity power
supplies with longer connection cables.
ENTTEC recommends IP65 rated or higher power supplies compatible with your
installation environment.
The maximum number of Dots that you can safely connect to a PSU is dependent
on the selected PSU’s power rating.
The total power consumption of a single chain of Smart PXL Dots must not
exceed the PSU’s maximum power rating OR the 10A current throughput limit of
each Smart PXL Dot. To determine the total power consumption of a chain of
ENTTEC Smart PXL 40 Dots, add together the power consumption for all
individual Dots using the figure given below:
The total figure must not be above 240W per chain to ensure the 10A power
throughput limit of each Smart PXL 40 Dot isn’t passed.
ENTTEC offers various control system options to drive Smart PXL Dots each
designed for different use case scenarios.
Information for each control system type and appropriate wiring methods can be
found within the Control Methods section of this guide. Ensure all cabling
and control systems have been housed in accordance with the specifications
defined within each product’s datasheet and in line with local electrical
regulations.
Data Cable Length & Direction
Smart PXL Dots are controlled using ENTTEC’s proprietary S-PXL 8/16 protocol.
This protocol sequentially addresses each Smart PXL Dot automatically. This
reduces commissioning time by eliminating the need for individual addressing.
Each Smart PXL Dot contains its own data buffering and data, re-shaping
circuit. The maximum permissible distances distance between devices is as
follows:
Max. distance between S-PXL 8/16 data source | 3000mm |
---|---|
Max. distance between Smart PXL string interconnects | 3000mm |
Max. customizable distance between Smart PXL Dots (pitch) | 2000mm |
S-PXL data can flow through each dot in one direction. This direction is
indicated on each string through:
– Direction arrow graphics laser etched into the first and last Dot of each
string.
– A direction arrow on each Smart PXL Dot’s PCB (visible on non-frosted dome
variants).
– The male connector denotes the input end of the string if your Smart PXL
Dots come with pre-attached connectors in the default configuration.
|
- S-PXL signal is unbalanced and susceptible to electrical noise. For best practice keep all cable run lengths to a minimum.
- Avoid running data cabling close to mains power or devices that emit electromagnetic noise (i.e. air conditioning units).
- If data direction instructions are not followed, Smart PXL Dots will not operate.
---|---
Control Channels
Each Smart PXL Dot consumes the equivalent of 6 DMX channels of data.
The hard upper limit to the number of dots you can run from one data feed can
be calculated by dividing the maximum number of data channels per output of
the ENTTEC pixel controller by the DMX channel footprint of the Smart PXL Dot.
Each Smart PXL Dot takes up 6 output channels from your controller whether
running in an 8-Bit, 16-Bit or grouped configuration all Smart PXL Dots in a
chain will sequentially address one after another.
| 16-Bit Smart PXL 40 Dot DMX Channel Footprint
---|---
Channel Order| 1| 2| 3| 4| 5| 6
Attribute| Red| Red Fine| Green| Green Fine| Blue| Blue Fine
The quantity of Smart PXL Dots addressable per ENTTEC controller is as follows:
ENTTEC Controller| Dimming Resolution Control| Maximum
Dot Quantity per Device| DMX Universes
Per Output Port| Total DMX Channels
Per Output| Maximum
Dot Quantity per Output| Outputs per
Device
---|---|---|---|---|---|---
OCTO| 8-Bit / 16-Bit| 680| 4| 2048| 340| 2
Pixelator| 8-Bit / 16-Bit| 4,080| 2| 1024| 170| 24
Pixelator Mini / DIN
Pixelator Mini| 8-Bit / 16-Bit| 1,360| 2| 1024| 170| 8
Pixie Driver| 8-Bit| 170| 2| 1024| 170| 2
Identical Outputs
Always consider all limiting factors outlined in this guide before
finalizing your system design.
Smart PXL Dot Control Options
ENTTEC offers various products to control Smart PXL Dots, each designed for
different use case scenarios. Key specification information and application
diagrams for each system can be found in the following section.
Controlling Smart PXL Dots with ENTTEC OCTOs
The OCTO is a 4 DIN module-wide device capable of converting a combined total
of 8 universes of pixel data from ArtNet, sACN, or KiNet (4 universes per
output) with a wide operating voltage between 4-60V DC.
It contains an inbuilt network switch for simple device chaining, allowing up
to 100m between each device.
The OCTO’s inbuilt web interface allows configuration and real-time
temperature monitoring of the device alongside basic standalone effects
generation for times your installation doesn’t require control from a
centralized playback device.
ENTTEC Controller| SKU| Form Factor| Smart PXL
ControlResolution| Maximum Smart PXL Dots Controllable per Device|
OAP– ..te map Per Device| Maximum Smart PXL Dots Controllable per
Output | Total DMX Channels
Per Output| DMX Universes
Per Output port
---|---|---|---|---|---|---|---|---
OCTO| 71520| 4 module
DIN (IP-20)| 8-Bit/ 16-Bit| 680 (8Universes)| 2| 340 (4Universes)| 2048| 4
*The maximum quantity of Dots controllable from this device is based upon
channel count, make sure to refer to the system specification/datasheet to
ensure all system limitations are considered for your system design.
For more information on the products & accessories featured within this guide
visit enttec.com
OCTO System Application Diagram
Key OCTO Installation Guidelines:
- Ensure all safety guidelines within this installation guide and other product documentation are factored into the design.
- Locate the OCTO and PSU as close as possible to the first Smart PXL Dot in the chain to reduce the impact of voltage drop.
- To reduce the likelihood of voltage being induced on the control signal lines, where possible, run control cabling away from mains electricity or devices that produce high EMF, (i.e. air conditioning units).
- ENTTEC recommends the use of cable ferrules for all stranded cables connected to the OCTO’s screw terminals to ensure a reliable connection.
Note: If the power or data source to your controller drops out whilst the Smart PXL Dots remain powered, the last state will be held until either the data feed resumes or power to the Smart PXL Dots is disconnected and reconnected.
Controlling Smart PXL Dots with ENTTEC’s Pixelator System
ENTTEC’s Pixelator system has been designed with reliability and flexibility
at its heart. The system comprises two key elements. The Pixelator device is
used to perform protocol conversion, and PLink injectors are used locally to
convert the data from the Pixelator close to the beginning of each chain of
dots.
Pixelator devises
Each Pixelator device is configurable via web interface over a local network
and converts DMX over ethernet (Art-Net, sACN, or ESP) to ENTTEC’s proprietary
PLink protocol designed to send control data over long distances. Each Plink
output can send 2 universes of data up to 300m over CAT6 cable to ENTTEC’s
PLink injector modules.
ENTER Controller| SKU| Form Factor| Dimming Resolution
Control| Maximum Theoretical Dot
Quantity per Device| DMX Universes
Per Output Port| Total DMX
Channels Per
Output| Maximum Dot
Quantity per
Output| Outputs per
Device
---|---|---|---|---|---|---|---|---
Pixelator| 70060| 19″ Rack 1RU
(IP-20)| 8-Bit /16-Bit| 4,080 (48U)| 2| 1024| 170| 24
Pixelator Mini| 70066| 9.5″ Rack 1RU (IP-20)| 8-Bit /16-Bit| 1,360 (16U)|
2| 1024| 170| 8
DIN Pixelator Mini PX1- 8D| 71066| 8 Module DIN (IP-20)| 8-Bit /16-Bit| 1,360
(16U)| 2| 1024| 170| 8
Do not mix controller types within a PLink System. Different Pixelator
models use different processing power appropriate to the hardware design. If
your installation requires multiple Pixelators, standardize on one variant to
eliminate the risk of content tearing.
PLink Injection Modules
ENTTEC’s compact PLink power injection modules are available in both indoor
and outdoor variants. These surface-mount modules convert the PLink signal
from the Pixelator to the S-PXL8 / S-PXL16 protocols without configuration.
The two variants compatible with Smart PXL Dots are as follows:
ENTTEC Injection Module| SKU| IP Rating| Data Outputs per
Device
---|---|---|---
Plink Injector (12-24v)| 73544| IP-20| 1
IP66 Plink Injector (custom /made to order item –contact the ENTTEC sales
team)| 73924| IP-66| 1
For more information on the products & accessories featured within this guide visit enttec.com
Pixelator System Application Diagram
Key Pixelator System Installation Guidelines:
- Ensure all safety guidelines within this guide and other product documentation are factored into the design.
- Locate the PLink and PSU as close as possible to the first Smart PXL Dot in the chain to reduce the impact of voltage drop.
- To reduce the likelihood of voltage being induced on the control signal lines, where possible, run control cabling away from mains electricity or devices that produce high EMF, (i.e. air conditioning units).
- ENTTEC recommends the use of cable ferrules for all stranded cables connected to the PLink’s screw terminals to ensure a reliable connection.
Note: If the power or data source to your controller drops out whilst the
Smart PXL Dots remain powered, the last state will be held until either the
data feed resumes or power to the Smart PXL Dots is disconnected and
reconnected.
Installation Guidelines
Always work with a plan of the installation that respects all system
limitations as defined within this guide and adheres to the safety
information.
Keep Smart PXL Dots and their accessories in their protective packaging until
final installation.
Note the serial number of each Smart PXL Dot string and add it to a layout
plan of your installation for internal reference.
- Ensure data is flowing from your controller through the string of dots following the data direction marked on the first and last Smart PXL Dot in the chain.
- Do not cover Smart Pixel Dots with insulating material of any kind.
- When installing dots or accessories DO NOT exert any tension on the cabling whilst tightening.
- Installation of this product must be performed by qualified personnel. If ever unsure always consult a professional.
- Ensure that no part of the installation is or can be connected to power until all work is complete.
- Do not install Smart PXL Dots if the lens, metalwork, or cabling is damaged.
- Before connecting Smart PXL Dots to a power supply, verify that the operating voltage and frequency are compatible and the power supply is appropriately fused in.
- Do not crush or clamp Smart PXL Dot or accessory cabling during installation.
- Do not leave connections unprotected or disconnected in damp or wet environments. All exposed connectors should be fitted with a Termination Plug (SKU 73015) to give a watertight seal to protect against corrosion.
- Do not handle Smart PXL Dot strings in an energized state.
- Do not bend the Smart PXL Dot or accessory cabling to a radius smaller than 30mm.
- Do not ‘hot swap’ Smart PXL Dot strings or their accessories.
- Do not leave connectors or accessory cabling in a position where they could cause a short circuit.
- Isolate the installation from power immediately if Smart PXL Dots, accessories power cables, or connectors is in any way damaged, defective, shows signs of overheating, or are wet (if not an IP65 component).
- Do not sign off a system without ensuring all Smart PXL Dot and accessory cabling is appropriately restrained, secure, and not under tension from the way it has been installed.
Attaching Smart PXL Dots & Accessories to a Surface or Structure
The Smart PXL 40’s body features 2 * M4 holes with 49mm spacing designed for
use with bolts, machine screws, or self-tapping screws rated to support the
weight of the full Smart PXL Dot string.
Cable termination end caps (sku:73015) feature a single M5 hole for use with
pan head screws and bolts.
ENTTEC produces Smart PXL Dot cable accessories for increased convenience on
site. All accessories use the same cabling and connectors as the Smart PXL
Dot. Cabling should be restrained with cable clips every suited to the surface
you are mounting your Smart PXL installation to every 0.5m.
Accessories should be used in line with the system design considerations of
your selected controller and adhere to the system cable length limitations in
this guide.
Ordering information can be found at the end of this document. For custom
pixel pitch or accessory, or cable length contacts the ENTTEC sales team.
Catenary mounting
ENTTEC recommends UV-resistant, outdoor-use rated cable ties for 2 wire
catenary support of the SmartPXL dots via the mounting holes to eliminate any
rotational stress. Do not position cable ties directly over any cable over
mold or heat-shrink-covered connections. Positioning cable ties over these
components will prevent them from acting as strain relief for the system and
may void the warranty.
If the pitch cable is sagging and needs to be restrained for aesthetic
purposes, a cable tie can be used but should be positioned as far away from
the over-mold or heat-shrink parts as possible. Do not tighten the cable tie
tight to the catenary cable as this will prevent the system from flexing and
dampening strain on the cable. It can also cause the cable to rub against the
catenary wire and wear away the insulation.
|
- Ensure the surface you are attaching Smart PXL Dots and accessories to is either fully electrically insulated or electrically earthed and can support the weight of all items you attach.
- Only drill holes or tighten screws into a surface that does not have cabling, pipework, or other services directly behind.
- Never energize a Smart PXL Dot system until installation is complete and it is safe to do so.
---|---
|
- When mounting Smart PXL Dots and accessories, ensure the mounting method is suitably rated to support the weight of the full Smart PXL Dot string.
- Never drill a hole or tighten screws into a surface using a Smart PXL Dot or accessory as a guide. This can result in damage and compromise the strength of the product.
- If installing Smart PXL Dots outdoors, only use corrosion proof galvanized, or stainlesssteel fixings rated for the installation conditions.
- Never allow a string of dots to hang from a structure during installation, this can result in strain to cabling and damage to the Smart PXL Dots.
---|---
In the latest version Hold a Smart PXL Dot or a Smart PXL Dot template
(downloadable from the ENTTEC website), or your
Cable termination end cap up to the surface and accurately mark the hole
positioning with a pencil, ensuring that the spacing between each dot and
accessory will not exert any strain on the Smart PXL Dot cable.
Remove the Smart PXL Dots from the surface and protect them from debris or
swarf whilst drilling pilot holes. Note: When installing cable termination
end caps, DO NOT connect the Smart PXL cabling until the screw has been
fully tightened to protect it from any unnecessary strain.
Screws
If securing Smart PXL Dots or accessories using self-tapping screws, without
the dot in place, line each screw up with each pencil mark and begin to
tighten it whilst ensuring the entry point is perpendicular to the surface.
After creating an entry point for the screw to bite, remove it from the surface.
Position each Smart PXL Dot in-line with the entry points, then insert and
fully tighten the screws. DO NOT exert any tension on the cabling whilst
tightening.
Bolts
If securing Smart Pixel Dots using a bolt, ensure a locking nut is used that
cannot come undone due to vibration and is tightly secured. DO NOT exert
any tension on the cabling whilst tightening.
Servicing, Inspection & Maintenance
- Servicing, inspection & maintenance should only be carried out by qualified technicians familiar with all safety information within this document and the Smart PXL Dot system.
- Smart PXL Dots and accessories have no user-serviceable parts. If your installation has become damaged parts should be replaced.
- Power down the entire system and ensure a method is in place to stop the system from becoming energized during Servicing, Inspection & Maintenance.
Key areas to examine during inspection:
- Ensure all connectors are mated securely and show no sign of damage.
- Ensure all connectors show no sign of corrosion.
- Ensure all cabling has not obtained physical damage or been crushed.
- Ensure all Smart PXL Dots and accessories are secured to the surface and have been installed in accordance with the guidelines set out within the installation guide.
- Check for dust or dirt build-up on the Smart PXL System and schedule cleaning if necessary. – Dirt or dust buildup can limit the ability of the Smart PXL Dot system to dissipate heat and can lead to damage.
If deemed necessary for a Smart PXL Dot string or accessory to be replaced, it
should be removed in a reverse order to installation as defined in this guide.
The replacement string or accessory should be an appropriate size and be
installed in accordance with all steps within the installation guide.
To order replacement parts contact your reseller or ENTTEC directly, making
sure to quote the serial number laser etched into either the first or last
Smart PXL Dot in each string you intend to replace. This can be used to
determine the precise specification or any customization options that are
applicable
Cleaning
Dust and dirt build-up can limit the ability of the Smart PXL Dot system to
dissipate heat resulting in damage. It’s important that the Smart PXL Dot
system is cleaned in a schedule fit for the environment it is installed within
to ensure maximum product longevity.
Cleaning schedules will vary greatly depending on the operating environment of
your Smart PXL Dots. Generally, the more extreme the environment, the shorter
the interval between cleanings.
- Before cleaning, power down the system and ensure a method is in place to stop the system from becoming energized until cleaning is complete.
- Do not use abrasive, corrosive, or solvent-based cleaning products on a Smart PXL Dot system.
- Do not spray Smart PXL Dots or accessories with a high-pressure water jet.
To clean an ENTTEC Smart PXL 40 system, use low-pressure compressed air to
remove dust, dirt, and loose particles. If deemed necessary, wipe the Smart
PXL Dots with a damp microfiber cloth.
A selection of environmental factors that may increase demand for frequent
cleaning includes:
- Use of stage fog, smoke, or atmospheric devices.
- High airflow rates (i.e. in close proximity to air conditioning vents).
- High pollution levels or cigarette smoke.
- Airborne dust (from building work, the natural environment, or pyrotechnic effects).
If any of these factors are present, inspect all elements of the system soon after installation to see whether cleaning is necessary, then check again at frequent intervals. This procedure will allow you to determine a reliable cleaning schedule for your installation.
Part Codes & Ordering Information
Smart PXL Dots
Product | SKU |
---|---|
Smart PXL 40 Dot – No Lens | 73010 |
Smart PXL 40 Dot–Dome Lens | 73011 |
Smart PXL 40 Dot – Clear Flat Lens | 73012 |
Smart PXL Dot Accessories
Product | SKU |
---|---|
Smart PXL – Termination End Cap (pack of 5 | 73015 |
Smart PXL – 2m Male Cable – 24v | 73017 |
Smart PXL – 2m Female Cable – 24v | 73018 |
Smart PXL – Power Injector – 24v | 73019 |
Smart PXL – 2m Extension Cable – 24v | 73020 |
Please refer to the datasheet or contact the ENTTEC team to discuss the customization options available.
Due to constant innovation, information within this
document is subject to change.
Smart PXL 40 DOT
Visit the ENTTEC website for the latest version
enttce.com
ID: 5920463
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>