ENTTEC Pixie Driver Powerful Ethernet-To-Pixel Protocol Converter User Manual
- June 4, 2024
- ENTTEC
Table of Contents
- Features
- Safety
- Physical Dimensions
- Wiring Diagrams
- Revision History
- Functional features
- Hardware features
- LCD Menu
- Out of the Box
- Networking
- Web Interface
- Settings/ Firmware Update
- Servicing, Inspection & Maintenance
- Package Contents
- Ordering Information
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Pixie Driver Powerful Ethernet-To-Pixel Protocol Converter
User Manual
ENTTEC’S PIXELMATOR is the 24-port Ethernet pixel controller within the
PIXELATOR family. Using ENTTEC’S PLINK protocol each port provides data to
ENTTEC’s PLINK INJECTORS which can control up to 2 Universes each, making the
PIXELATOR powerful enough to control up to 24,576 channels (8,192 RGB pixels)
with perfect synchronization across all of its outputs.
The PIXELATOR supports a wide range of pixel protocols, which can be
controlled with sACN, Art Net, ESP, and Kling-Net through an intuitive web
browser, controlling LED pixels, dots, and digital strips have never been
easier.
Our PLINK protocol can transmit up to 1024 channels (2 Universes) over a 300m
distance using Cat5e/Cat6 cable to each ENTTEC PLINK INJECTOR. This allows for
control of up to 340 RGB or 256 RGBW pixel per output. This satellite system
provides great flexibility, and since all data conversion is processed on the
PIXELATOR, the P- Link injector is kept as compact as possible.
Depending on the application, choose between the indoor or outdoor IP PLINK
INJECTORs, ensuring that the voltage is compatible with the pixels and power
supply which are installed locally to the PLINK INJECTORS.
Features
- 24* RJ-45 ports (each providing 2 Universes of PLINK data output)
- 48 Universe Ethernet to PLINK data over Cat5e/Cat6 cable
- 1U Rack form factor
- Easy to setup & update through any web browser
- Supports sACN, Art-Net, ESP, and Kling-Net
- RJ45 Ethercon connector (10/100 Mbps)
- Static or Dynamic (DHCP) IP configuration (DHCP by default)
- Compatible with ENTTEC PLINK INJECTORs
- Pixel Grouping is configurable for each PLINK port. (1 to 340) for RGB and (1 to 256) for RGBW
- Each PLINK output can be assigned up to 2 Ethernet Universes.
- Pixel Ordering is configurable for each PLINK port. Drives 2 DMX universes of Pixel Tape/Dots.
- Each port outputs at 40 frames per second
- ArtSync support to ensure all outputs are in synchronization with each other.
- Clock module to sync multiple universes output and an in-built DMX Generator
- Dual-core CPU, with a clock speed 2GHz provides efficient and reliable output
- 1GB DDR3 RAM – allows the best utilization of the system.
Safety
Ensure you are familiarized with all key information within this guide and
other relevant ENTTEC documentation before specifying, installing, or
operating an ENTTEC device. If you are in any doubt about system safety, or
you plan to install an ENTTEC device in a configuration that is not covered
within this guide, contact ENTTEC or your ENTTEC supplier for assistance.
ENTTEC’s return to base warranty for this product does not cover damage caused
by inappropriate use, application, or modification to the product.
Electrical safety
- This device must be operated in accordance with applicable national and local electrical and construction codes.
- This device can be damaged by excess voltage outside the operating range defined within this product’s datasheet.
- To reduce the risk of fire or electrical faults do not exceed the ratings and limitations defined in the product datasheet or this guide.
- Ensure there are no opportunities for cables to short circuit and cabling cannot be snagged or pulled.
- Do not over-stretch the cabling to the device’s connectors and ensure that the cabling does not exert force on the PCB.
- Isolate your installation from power immediately if accessories power cables or connectors are in any way damaged, defective, shows signs of overheating or is wet.
- Remove power from this product during cleaning or when it is not in use.
- Do not connect this device to a dimmer pack or mains electricity.
- Do not connect any of this device’s V- or GND connectors to earth.
- Ensure your installation is protected from short circuits and overcurrent.
- Ensure all connections are complete and secure before providing power to the device.
System Planning and Specification
- To contribute to an optimal operating temperature, where possible keep this device out of direct sunlight.
- This unit has an IP20 rating and is not designed to be exposed to moisture or condensing humidity.
- Ensure this device is only operated within the specified ranges within the product datasheet.
Protection from Injury During Installation
- Always use suitable personal protective equipment when installing ENTTEC products.
- Once installation is completed, check that all hardware and components are securely in place and fastened to supporting structures if applicable.
Installation Safety Guidelines
- The device is convection cooled, ensuring it receives sufficient airflow so heat can be dissipated.
- Do not cover the device with insulating material of any kind.
- Do not operate the device if the ambient temperature exceeds that stated in the device specifications.
- Do not cover or enclose the device without a suitable and proven method of dissipating heat.
- Do not install the device in damp or wet environments.
- Do not modify the device hardware in any way.
- Do not use the device if you see any signs of damage.
- Do not handle the device in an energized state.
- Do not crush or clamp the device during installation.
- Do not sign off a system without ensuring all cabling to the device and accessories has been appropriately restrained, secured, and is not under tension.
Physical Dimensions
All dimensions are in millimeters unless specified otherwise.
Wiring Diagrams
Revision History
Rev C
A core software change.
Introduction of the new low-level base operating system for faster boot times
and security improvements.
Removal of RS232 features (RevB).
Rev B
Updated hardware introducing shared processing on the main and output card.
Increased processing power resulting in higher refresh rates.
Web Interface – Settings – RS232 String: This provided the ability to activate
different profiles using the following RS232 string template: P-00x. As an
example, if you wanted to trigger Profile ID 4, then the RS232 command would
be P-004.
- Baud Rate: 9600, Data: 8-bit, Parity: none, Stop: 1-bit, Flow Control: none.
- To test the connection, send character ‘V’. This should return the version info string.
Rev A-No Longer Supported.
Functional features
Profiles
The PIXELATOR has a set of default profiles that you can activate via the web interface or the LCD, to start you off. For example:
- Artnet24->Pixel24: This profile will take 24 Art-Net universes and convert them to 24 Pixel-Link streams on ports 1 to 24.
- Artnet48->Pixel24: This profile will take 48 Art-Net universes and convert them to 24 Pixel-Link streams on ports 1 to 24. (Each Port will be mapped to 2 Art-Net Universes consecutively)
Profiles can be edited or created within the web interface of the PIXELATOR.
With the use of an intuitive drag and drop system to add ‘modules’ to the
PIXELATOR’s Profile. Add and configure incoming ethernet streams (Art-Net,
ESP, Kinet, sACN) and assign them to different PLINK outputs.
The PIXELATOR can store multiple Profiles allowing different configurations to
be created. Changing from one profile to another can be done in a web browser
window, or with the touch of a few buttons on the front panel (LCD menu).
PLINK INJECTORS
From one of the PIXELATOR’S PLINK Data outputs, you can run up to 300m of Cat6
cable to a single PLINK INJECTOR. Since all data conversion is processed on
the PIXELATOR, the PLINK INJECTOR is kept as compact as possible. At the
PLINK
INJECTOR, you can wire up an external DC power supply. The PLINK has the
capability to handle 10amps through the device.
It is important that your power supply voltage matches the voltage of your
Pixels, as well as having a PLINK that is compatible with the voltage range:
- SKU 73546 is designed for Pixels with a 5-volt input.
- SKU 73544 is designed for Pixels with a 12-24 volt input.
Each PLINK INJECTOR can then be wired up to 3m (total cable length) away from
the first Pixel. The PLINK INJECTOR can drive up to 340 RGB individual pixels
(2 OMX universes) – The PLINK 2U module must be used in PIXELATOR Profile.
The PIXELATOR can control a range of SPI (Pixel) protocols, a full list can be
found on our website.
PLINK Data: The PIXELATOR converts Art-Net, sACN, ESP, and Ki Net into
our own PLINK data, which over Cat6 cable can run up to 300m to a PLINK
INJECTOR, where it is converted to the SPI (Pixel) protocol.
PLINK Data Pinout: PLINK Data is sent over a Cat6 cable using 3 pins of
an RJ45 connector. These pins are:
- Pin 1: Data+
- Pin 2: Data
- Pin 7: 0V
Hardware features
- 24* PLINKOutput(RJ-45)
- 1 LAN port (RJ45)
- 1 DB9 Connector (un-used)
- 2* USB Ports (un-used)
LCD Menu
The LCD Menu is navigated through the four-panel buttons on the front of the
unit.
The Menu button acts as the “Back” button, which takes you to the previous
Menu /screen.
The Enter button goes into the selected option on the screen and activates the
option.
The Top & Bottom buttons are used to navigate/scroll through the options on
any screen. The currently selected option is highlighted with a white
background on the screen.
Main Menu
Line1: Displays the System Name and currently Selected Profile.
Line2: Displays the network status of the PIXELATOR.
If a connection is made, the PIXELATOR’s IP address (DHCP or Static) will be
shown, this address can be used to access the web interface.
If no connection is made, a message would display as DHCP Failed or
disconnected.
Line3: Displays the number of packets currently passing through the
PIXELATOR. This number of packets per second can be used as an indicator of
the activity on your network.
Pressing any of the panel buttons/keys will activate the Selection Menu.
Selection Menu
- load profile
- Setup
- Status
- Lock Unit
- Restart
1-Load Profile: Lists all available profiles on the PIXELATOR, the list
can be scrolled using up & down keys.
The scrolling indicator is visible when the list allows scrolling. Pressing
Enter at the selected profile will activate the profile.
2-Setup: Setup screen allows changing the IP address of the unit via
“Change IP” or doing Factory Reset.
- Change IP
- Factory Reset
- Change IP: This screen further gives two options DHCP or Static IP. When Static IP is selected, the screen allows you to change the IP address using the top and bottom buttons to scroll the digits and the menu & enter buttons to select the segment. Once you are on the last segment of the IP address, pressing the Enter button will activate the IP address.
It will take a few seconds for the change to go through, please wait 30 seconds, before attempting to try again.
Change IP Address
IP: 192.168.001.003
- Factory Reset: Activating Factory Reset, leads to a simple prompt confirming your action. Once confirmed, the Factory Reset will take a few seconds to run. It will end up deleting all your user-created profiles, as well as any saved settings. Please use this only when needed, or as directed by the ENTTEC support team.
F-Reset in progress
please wait …
3-Status: Provides read-only information for both the system and the network. These require no user input and serve as a way of checking the performance of the unit.
1-System
2-Network
4-Lock Unit (revB only): Provides the option to lock your device by disabling the web interface to provide an additional level of security to your installation. By locking your device, the web server becomes inactive meaning that your configuration cannot be modified. Factory resetting a device will not unlock the device, this must be done using the LCD menu. ENTTEC strongly recommends you secure your network and do not connect your lighting control network to the internet without relevant precautions in place. If unsure consult a specialist within this field.
To lock and unlock your device follow these simple steps on the device LCD menu:
- Press Enter on the unit LCD menu
- Navigate to option 4-Lock Unit and press Enter
- Select Yes to lock or No to unlock.
- Wait 10 seconds for this to take effect.
5-Restart: You will be asked to confirm that you want to restart your PIXELATOR.
Once confirmed, the PIXELATOR will stop the output engine and restart the system. This process will take a couple of minutes. While rebooting the LCD screen will change between a couple of screens, the restart will be complete once the Main Menu is displayed
System Restarting
Please wait …
Out of the Box
As default, the PIXELATOR will have the Artnet48->Pixel24 Profile active, this
profile will take 48 Art-Net universes starting at universe 0 (0x00) and
convert them to 24 Pixel-Link streams on ports 1 to 24. (Each Port will be
mapped to 2 sequential Art-Net Universes).
The PIXELATOR will be set to a DHCP IP address as default. A DHCP server is
required to be required.
Networking
The PIXELATOR can either be configured to be a DHCP or a Static IP address.
DHCP: On power up and with DHCP enabled, if the PIXELATOR is on a network
with a device/router with a DHCP server, the PIXELATOR will request an IP
address from the server.
If the DHCP server is slow to respond, or your network does not have a DHCP
server, the PIXELATOR will fall back to the Static IP address. If a DHCP
address is provided, this can be used to communicate with the PIXELATOR.
Static IP: By default (out of the box) the Static IP address will be
unique based on the device’s Serial Number (See out of the box section for
details). If the PIXELATOR has DHCP disabled or if the PIXELATOR falls back
to the Static IP address after being unable to find a DHCP server, the Static
IP address given to the device will become the IP address to communicate with
the PIXELATOR. The fall-back address will change from the default once it is
modified in the web interface.
Web Interface
Configuring the PIXELATOR is done through a web interface that can be brought up on any modern web browser.
- A Chromium-based browser (i.e. Google Chrome) is recommended for accessing the PIXELATOR web interface.
- As the PIXELATOR is hosting a web server on the local network and does not feature an SSL Certificate (used to secure online content), the web browser will display the ‘Not secure’ warning, this is to be expected.
Identified IP address: If you are aware of the PIXELATOR IP address (either DHCP or Static), then the address can be typed directly into the web browser’s URL field. The PIXELATOR’s IP address can be located on the LCD’s Main Menu.
Unidentified IP address: If you are not aware of the PIXELATOR’s IP address (either DHCP or Static) the following discovery methods can be used on a local network to discover devices:
- An IP scanning software application (i.e. Angry IP Scanner) can be run on the local network to return a list of active devices on a local network.
- Devices can be discovered using Art Poll (i.e. OMX Workshop if set to use ArtNet).
- The device’s Default IP address will be printed on the physical label on the rear of the product.
- ENTTEC free NMU (Node Management Utility) software for Windows and macOS (support up to Mac OSX 10.11), which will Discover ENTTEC devices on the Local Area Network, displaying their IP addresses before opting to Configure the device, opening the Web Interface.
Note: The eDMX protocols, the controller, and the device used to configure the PIXELATOR must be on the same Local Area Network (LAN) and be within the same IP address range as the PIXELATOR. For example, if your PIXELATOR is on Static IP address 10.8.17.38, then your computer should be set to an IP on a similar subnet i.e. 10.8.17.20. It’s recommended that all device’s Subnet masks are the same across your network.
Home
The landing page for the PIXELATOR web interface is the Home tab. This tab is designed to give you a read only device overview.
This will display:
■ IP Address | ■ Active Profile |
---|---|
■ Subnet | ■ System Name |
■ Broadcast Address | ■ Packets per sec |
■ Hardware ID | ■ License Information |
■ ArtNet 3 Net | ■ System Version Number |
■ System status | ■ 10 version numbers |
Profiles
Within this window, you can create, manage, and activate Profiles within the PIXELATOR. Profiles allow you to configure that Data is sent to the 2¢ outputs, as well as allow you to change between profiles during the installation if required.
The PIXELATOR comes with some Read-Only profiles on the PIXELATOR as default, these will be displayed within the ‘Remarks’ column. These wilts reappear after a Factory Reset.
Use the radio button under the ‘Active’ column to select a Profile to use the functionality along the bottom of the page. Clicking on the Profile name will launch the profile in the profile editor window.
Profile Editor:
Create a new profile or edit an existing one using the profile editor. Profile
Editor opens on a new page in your web browser. Selecting a module on the left
and the right panel will provide help with that panel. Connect a module to
another using wire from one point to another.
The direction of the wire (arrow) is important, the arrow signifies output,
and reflects the flow of data. The same PLINK port#t cannot be re-used within
the same profile.
Profile Modules:
Each profile is made up of two or more connected Modules or Actions. The relationship between them forms the layout of the data flow within the profile. The following modules are available:
-
PLINK 1U: The PLINK 1U module represents one of the physical ports on the rear of this unit, and maps to 1 Universe. Within this Module you will need to select:
□ Protocol: select the led protocol that the pixel tape conforms to.
□ Ordering: RGB or RGBW mapping that the pixel tape conforms to. RGB modes use 3 DMX slots per LED pixel, and RGBW modes use 4 DMX slots.
□ Grouping: it allows one DMX pixel to drive multiple physical LED pixels
□ Start-Ch: DMX Start Channel for the 1st pixel can be changed as needed. -
PLINK 2U: The PLINK 2U module represents one of the physical ports on the rear of this unit, and maps to 2 Universe. Within this Module you will need to select:
□ Each PLINK 2U module has 2 input nodes that can be connected to two Ethernet streams. The top one (U1) is mapped to the First universe and the Bottom one (U2) is mapped to the Second universe relative to the pixel tape.
□ Protocol: select the led protocol that the pixel tape conforms to.
□ Ordering: RGB or RGBW mapping that the pixel tape conforms to. -
Art-Net Stream: “Send IP address”: is the destination address used when the stream is sending data only.
-
ESP Stream: ENTTEC Show protocol DMX over Ethernet stream (ESP).
-
Kinet Stream: For example, You can connect Kinet Stream to an Art-Net Stream to convert and output as Art-Net. (Ki net stream is supported as input only).
-
Streaming ACN: “IP address” is the destination address used when the stream is sending data only (default is disabled= 0.0.0.0)
-
Streaming ACN: “IP address” is the destination address used when the stream is sending data only (default is disabled= 0.0.0.0)
-
DMX Generator: Define your own custom DMX Channel values and assign the selected ones. The snapshot feature can be used to capture values from an input stream. All modifications can be done using the DMX Grid Page.
-
Clock: Allows you to synchronize ALL Pixel Link output only when the connected Input Stream is received.
The Clock module can be used to make sure the output is always synced to the “latest universe” especially if the source adds a delay to each universe.
□ Auto-repeat allows the user to repeat the output once every “number of seconds” regardless of Synced Stream
□ Default behavior [Auto-repeat = Never]: Will only refresh Pixe Link when Synced Stream is received
Settings/ Firmware Update
The PIXELATOR’s settings can be configured within the Settings tab.
Firmware Update: The latest firmware can be downloaded from our website.
Using the Choose File button, browse on your local drive for the downloaded
PIXELATOR firmware file, this will have a .bin extension. Next click on the
Update Firmware button to begin updating.
Note: Updating the firmware will cause the PIXELATOR’S normal operation
to stop.
After the firmware has updated the PIXELATOR will reboot to allow the changes
to take place. Please see the LCD screen on the front of the PIXELATOR to see
the IP address of the unit.
System Name: The name will be discoverable within Poll replies. This
needs to be saved for the change to take effect.
Hovering Help: Help screens can be Enabled/Disabled depending on if you
want to see the help pop-ups.
This needs to be saved for the changes to take effect.
Network Interface: Here you can change the Network settings to either
Enable/Disable DHCP, or to set a Static IP address including Net Mask and
optional Gateway. When DHCP is enabled, the DHCP server on the network is
expected to automatically provide the IP address to the PIXELATOR. If no DHCP
router/server is present or DHCP is disabled, the PIXELATOR will fall back to
the static IP address. Any changes will need to be saved to take effect and
the PIXELATOR will reboot. Please see the LCD screen on the front of the
PIXELATED to see the IP address of the unit.
Art-Net3 Address (Net): Whilst using Art-Net on the PIXELATOR, all universes
must be within the same Net range (for example universe range 0-255 or 256 to
511).
sACN CID: The PIXELATOR’s unique sACN Component Identifier (CID) is
displayed here and will be used in all sACN communication.
Backup and Restore
Full System Backup: This includes a full backup of the system, including
all settings, options, and profiles. This can be used to later restore the
PIXELATOR to previous settings. or can be used to migrate or duplicate from
one PIXELATOR to another.
Full System Restore : Using a previous backup file, you can restore a
PIXELATOR back to previous settings to migrate or duplicate from one PIXELATOR
to another. Ensure that the file name matches the formatting displayed on the
web interface. Warning: This will replace any settings, options, and profiles
on the PIXELATOR.
Individual Profile Export: This will export a single profile from the PIXELATOR, which can be used as a backup or to migrate to another PIXELATOR. Use the drop-down to select the Profile before clicking ‘Export Profile’.
Individual Profile Import: This will import a single profile to the PIXELATOR. The profile should have been taken from another PIXELATOR. Use ‘Choose File’ to locate the profile on your local computer. Click ‘Import Profile’ to add the new profile to this PIXELATOR’s profile list.
Reset to Factory Defaults: Warning: This will reset all options,
settings, and profiles to their Factory Defaults.
After the reset is complete the PIXELATOR will reboot to allow the changes to
take place. Please see the LCD screen on the front of the PIXELATOR to see the
IP address of the unit.
Stream Auditor
The Stream Auditor will provide you with an overview of the PLINK outputs as
well as the inputs which are being used on the active profile. Here you can
see if the signal is being received and if those values are changing, as well
as the packet information.
Use the Peek button to monitor the values for each stream.
Servicing, Inspection & Maintenance
- The device has no user-serviceable parts. If your installation has become damaged, parts should be replaced.
- Power down the device and ensure a method is in place to stop the system from becoming energized during servicing, inspection & maintenance.
Key areas to examine during inspection:
- Ensure all connectors are mated securely and show no sign of damage or corrosion.
- Ensure all cabling has not obtained physical damage or been crushed.
- Check for dust or dirt buildup on the device and schedule cleaning if necessary.
- Dirt or dust buildup can limit the ability of a device to dissipate heat and can lead to damage.
The replacement device should be installed in accordance with all steps within
the installation guide.
To order replacement devices or accessories contact your reseller or message
ENTTEC directly.
Cleaning
Dust and dirt build-up can limit the ability of the device to dissipate heat
resulting in damage. It’s important that the device is cleaned in a schedule
fit for the environment it is installed within to ensure maximum product
longevity.
Cleaning schedules will vary greatly depending on the operating environment.
Generally, the more extreme the environment, the shorter the interval between
cleanings.
- Before cleaning, power down your system and ensure a method is in place to stop the system from becoming energized until cleaning is complete.
- Do not use abrasive, corrosive, or solvent-based cleaning products on a device.
- Do not spray devices or accessories. The device is an IP20 product.
To clean an ENTTEC device, use low-pressure compressed air to remove dust,
dirt, and loose particles.
If deemed necessary, wipe the device with a damp microfiber cloth.
A selection of environmental factors that may increase the need for frequent
cleaning include:
- Use of stage fog, smoke or atmospheric devices.
- High airflow rates (i.e., in close proximity to air conditioning vents).
- High pollution levels or cigarette smoke.
- Airborne dust (from building work, the natural environment, or pyrotechnic effects).
If any of these factors are present, inspect all elements of the system soon after installation to see whether cleaning is necessary, then check again at frequent intervals. This procedure will allow you to determine a reliable cleaning schedule for your installation.
Package Contents
- PIXAR
- Ethernet Cable
- IEC cable
Ordering Information
For further support and to browse ENTTEC’s range of products visit the ENTTEC website.
Item | Part No. |
---|---|
PIXElATOR | 70060 |
Plink 5v | 73546 |
Plink 12v-24v | 73544 |
enttec.com
MELBOURNE AUS/ LONDON UK/ RALEIGH-DURHAM USA
Read User Manual Online (PDF format)