coVita Micro Plus Baby Smokerlyzer User Guide
- June 3, 2024
- coVita
Table of Contents
Micro
Plus Baby Smokerlyzer “
User Guide
www.covita.net | 800.707.5751
Copyright 2022 coVita LLC
All Rights Reserved v062620
Micro Plus Baby Smokerlyzer
Helping People to Stop Smoking, One Breath at a Time™
Quick Start Guide v1
Sections
A. Welcome from the coVita Family
B. Contents
C. Monitor Layout
D. Tips & Maintenance
E. Infection Control
F. How to Perform A Breath Test
G. Key Features
Welcome from the coVita Family
Dear Valued coVita Client,
Thank you for being part of the coVita family where we are celebrating 30+
years of saving and improving lives with our Smokerlyzer® monitors.
We wanted to remind you of the following:
- coVita includes U.S.A. based complimentary life time telephone support and online training courses
- Access to coVita’s staff of Certified Tobacco Treatment Specialists (CTTS)
- coVita includes an industry leading 5 year warranty on the Micro+™ pro, baby, basic® Smokerlyzer family of monitors
Please review coVita’s new website & Education Destination at
www.covita.net/support/
Here you will find the following complimentary information:
- Online Training Course
- Quiz for Certification and Certificate of Completion
- Reference Guides
- Quick Start, Calibration, Use & Infection Control Guides
- CPT Codes for Reimbursement
- Logs for Groups & Individuals
- Interpretation Materials
- Hand Outs & Explanations of the CO Readings
- Instructional Videos
The coVita family values and appreciates our relationship.
Together we can make a difference in peoples’ lives everyday.
Sincerely,
– the coVita Family
Contents
- Micro+™baby CO Monitor
- D-Piece™ One-Way Valve to filter out viral particles & bacterial spores (replaced every 28 days)
- SteriBreath™ Mouthpiece (single use)
- USB Cable
- (3) AA Alkaline Batteries –USE ONLY ALKALINE
- Monitor Microfiber Sleeve – can be used to protect and clean your monitor screen
- Carrying bag for monitor & accessory storage
- Quick Start Guide
- Smokerlyzer ® CO conversion charts: MaternityCO Chart – COppm to %FCOHb & %COHb ®
- Smokerlyzer Poster
- Infection Control Guide
Note: Full Manual & COdata+ patient database software can be downloadedat www.covita.net
Monitor Layout
- LCD Display
- Power Button
- SteriTouch™- patented additive integrated into the monitor housing, engineered to kill 99.99% bacteria on contact
- D-Piece™ Valve Opening
- Exhaust Port – DO NOT COVER
- USB Connector
- Vent Hole – DO NOT COVER WITH LABELS ETC.
- Battery Compartment
- Battery compartment clip
- Reset Button**
- Programming Switch**
DO NOT USE UNLESS INSTRUCTED BY COVITA
Tips & Maintenance
- Change your D-piece™ valve every 28 days.
- Calibrate every 6 months to correct for sensor drift using 20 ppm coVita calibration gas.
- Don’t oversaturate the screen with liquid when wiping down your monitor. This can leak into the PCB board and can cause damage.
- Never store your monitor around cleansing products containing harsh chemicals, other cleaning agents or solvents.
- Never block the air/vent hole on the back of the monitor with labels.
Industry Leading Infection Control Technologies
The surface of your monitor has an added material known as SteriTouch ® , an
antimicrobial product, offers protection against a range of bacteria including
E.coli, MRSA, Salmonella and Legionella, as well as black mold growth, biofilm
and fungi 1 .
Statement from SteriTouch ® manufacturer states “Coronavirus COVID-19 is an
enveloped virus, so called because of its fatty outer membrane or ‘envelope’.
Several of the active substances we use have been successfully tested against
other enveloped viruses, such as Influenza, Avian flu and SARS. It would be
reasonable to imply that those same active substances would be effective
against COVID-19, but at this stage testing against COVID-19 is not
available.”
D-piece™ Valves
The D-piece™ contains a one-way valve and an integrated infection control
filter with the ability to filter out viral particles and bacterial spores.
The D-piece™ filters have been independently tested for prevention of cross
infection. We are happy to announce based on this data Bedfont concluded that
bacterial and viral pathogens including (COVID-19 / SARS-COV-2) will
effectively be removed by the D-piece™ filter at an efficiency rate of >99%
(bacteria) and >97% (viruses).
– Replace Monthly.
SteriBreath™ Eco Mouthpieces
The SteriBreath ™ Eco mouthpieces are for single-use ONLY. SteriBreath™ Eco
mouthpieces are entirely made from paper and are 100% recyclable and 100%
biodegradable.
The mouthpieces are individually wrapped for convenience, ease of handling
and greater infection control.
Wipes & Hand Sanitizers
NEVER STORE your monitor around cleansing products containing harsh chemicals
or other cleaning agents or solvents.
coVita offers alcohol-free cleansing wipes which are specifically engineered
for use on our monitors and accessories. Effective against 99.999% of Germs,
Spores, Bacteria, and Fungi. Tested against H5N1 Avian Flu and H1N1 Swine Flu.
Additionally, been tested by the supplier and found effective against
(COVID-19 / SARS-COV-2), as the product shows efficacy against feline
coronavirus, a surrogate coronavirus (for COVID-19 / SARS-COV-2).
Additionally, coVita offers a hand sanitizer which was designed to safely and
gently cleanse your hands. Because it’s engineered to be alcoholfree, its
gentle on your hands and it won’t interfere with your monitor’s sensor or
accessories. Kills 99.99% of germs,bacteria, & fungi without drying your
skin.
How to Perform a Breath Test
1. Turn on the monitor by pressing & releasing the button on top of the
monitor.| 2. Insert a D-piece™ & SteriBreath™Eco mouthpiece into the monitor.
Note:
Round opening of D-piece ™ faces you.
3. Press Female or Male Breath Test icon when ready to begin a test.| 4.
Instruct patient to take a deep breath and hold.
5. Patient should hold their breath during the 15 second countdown period.|
6. At the end of the countdown when you hear the third beep instruct the
patient to place mouth on the mouthpiece and exhale all of the air out of
their lungs.
| 7. The monitor has finished interpreting the sample
when the three icons appear at the bottom of screen. The readings will be
displayed in PPM, %COHb.
Note: If testing a pregnant woman press the fetus icon to see the fetal
conversation. To return the previous screen press the fetus. Press the home
icon to return to the main home screen.
Key Features & Tips
LOG. The monitor auto logs the last 150 readings with a time and date stamp. The log can be accessed by pressing the gear icon on the home screen and then pressing the log icon. Press the arrow toscroll through the pages of readings. Press the home icon to return home. On/Off. To turn off your monitor press and hold the power button for 3 seconds.Monitor will also power off after 2 minutes of inactivity to save power.