INOVAAIR AirClean E20 Plus Air Purifier User Manual
- June 5, 2024
- INOVAAIR
Table of Contents
- INOVAAIR AirClean E20 Plus Air Purifier
- Important safety instructions
- Introducing your InovaAir® AirClean system
- How your AirClean system works
- Positioning your AirClean system
- System operation
- Tips for getting the most out of your Air Purifier
- Accessing the filters
- When to replace the filters
- Replacing filters
- Ordering new filters
- System warranty
- Year warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INOVAAIR AirClean E20 Plus Air Purifier
Important safety instructions
Please read these instructions before operating the InovaAir® System and keep for future reference.
To reduce the risk of fire, electric shock, or injury
- Do not detach the motor-outlet module until the system has been switched off.
- Disconnect power, or unplug, before cleaning, performing any maintenance or replacing a filter.
- Use caution when moving the air purifier to avoid injury. We advise removing the filters prior to lifting or transporting the system.
- Do not operate unless all components are fully assembled, securely latched and in the upright position. Failure to do so may result in serious injury.
- Leave a distance of at least 150mm between the appliance and the nearest wall to allow for adequate air circulation.
- Always keep air intake and outlet of the unit unobstructed.
- Do not use near water or moisture or the immediate surroundings of a bath, shower, or swimming pool.
- o not immerse the air purifier in water or any other liquid.
- Do not let objects, or liquid, enter the product.
- Do not handle any part of the appliance or plug with wet hands.
- Clean only with a dry cloth.
- Do not install near any heat sources.
- Do not operate this appliance if it has a damaged cord or plug, is not working correctly, or has been dropped.
- Do not use this appliance if it has been damaged or submerged in water.
- The appliance is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- If the supply cord is damaged, it must be replaced with a new cord. Contact our support team for a replacement.
- Keep power cord away from heated surfaces.
- Refer all servicing to qualified InovaAir® service personal. Servicing is required when the product has been damaged in any way. Do not attempt to service this product yourself. Opening or removing covers may expose you to dangerous voltages or other hazards and may void warranty.
- Unplug the air purifier during lightning storms or when unused for long periods.
- Do not use this appliance as sole protection against harmful pollutants.
- Do not use outdoors.
- Keep the appliance away from flammable liquids, vapours, air fresheners and essential oils.
- Do not use in explosive or flammable environments.
- Use only on solid, horizontal, and stable surfaces.
Introducing your InovaAir® AirClean system
Inside the E20 Plus boxes, you will find the InovaAir® unit consisting:
- E20 System Case/Motor
- ilter Base Plate (detachable)
- Power Cable (located in base of box)
- E20/DE20 Pre-filter (pre-installed)
- E20 HEPA Filter (pre-installed)
- E20 6kg Activated Carbon Filter (supplied in a separate box)
The inner Activated Carbon filter will need to be installed prior to use (see page 10)
Please ensure the two latches at the base of the unit are engaged. BEFORE moving or lifting system, failure to do so may result in injury.
How your AirClean system works
- Air is drawn into the system through the sides of the unit.
- Air passes through the dust pre-filter.
- Air passes through the H13 HEPA filter which removes dust, allergens, and sub-micron fine particle matter.
- Chemicals and odors are removed from the air in the final stage by the Activated Carbon filter.
- The purified air is then returned to the room via the high air-flow diffuser.
Positioning your AirClean system
There are two main points to consider: where you spend your time and where the main pollutants are. The longer you keep your InovaAir® in a single room, the cleaner the air in that room will be. As with a heater or air conditioner, the InovaAir® purifier will only be effective if windows are closed during operation. Your InovaAir® Airclean works best when it has plenty of unrestricted airflow around it. It is also important to make sure the Air Purifier has easy access to a power outlet as long cords can be a tripping hazard and may result in damage to the unit should it be knocked over.
System operation
Speed Control
The system has a variable speed controller and uses an energy-efficient
European AC fan. Power consumption is relative to the selected
speed.
The higher the speed the more times per hour the air in your living space will be cleaned, so it is recommended to run the system at the highest speed you are comfortable with. Higher fan speeds will generate higher sound levels. Generally for sleeping, an ideal setting is position 1-2.
Please note, There can be a delay of up to 20 seconds before the fan is running at the speed you have selected.
Tips for getting the most out of your Air Purifier
Always operate the system with windows closed.
Air purifiers are not designed to filter the great outdoors, like an air
conditioner or heater leaving a window open will render the system
ineffective. Use of evaporative coolers will also reduce effectiveness.
Operate the system 24/7.
As dust, allergens, and chemicals are always present in the air, for maximum
effectiveness you should operate the system continuously. By switching the
system off you are only allowing these contaminants to build up in the interim
until it is switched back on. InovaAir systems are designed for optimal energy
efficiency – so don’t be concerned about power consumption as this will barely
be noticeable on an electricity bill.
Decide where you need clean air the most.
Typically for allergy and asthma sufferers, use while sleeping will be an
important part of how you use your air purifier. If you have a high-capacity
system with adequate coverage, it can be moved between living areas during the
day and the bedroom at night. Operation for 15-30mins on high speed will
dramatically reduce the bulk of airborne particulates when moving into a new
room.
Enclose the area where you are operating the system.
If you close a bedroom door the system will be much more effective as it will
only be filtering air in one room. If you move to larger areas, if possible,
close off surrounding areas to maintain clean air in that space. E7 and E8
models are designed primarily for bedroom use, while the high capacity E20
series is designed to cover large living areas and be moved to bedrooms for
nighttime use.
Operate at the highest speed you are comfortable with.
All InovaAir systems include variable speed controls and the speed should be
varied depending on the room size, the level of air pollutants present, and
the sensitivity of the individual. The higher the operating speed the more
effective the system will be, as the purifier will be filtering the air more
times every hour resulting in lower levels of particles and certain chemicals.
When operating smaller systems in larger areas, increase the operating speed
to enable the system to filter the air more effectively.
Activated carbon filters.
While they are highly efficient at removing chemicals and odors, if you have
high levels of any chemicals or odors they will absorb these from the air
quickly and the filter life will be reduced. If you want to prolong the life
of the activated carbon filter, you should turn the system off while cooking
or if there are any heavy transient odors.
Check your pre-filters regularly for dust build-up.
We recommend that you check your pre-filter after every three months of
operation to visually inspect the level of dust buildup. Pre-filters typically
last between 4 to 6 months based on average dust levels in a home environment.
If the levels of dust in your home are high due to external factors such as
living near the main road, you may need to change your filters more regularly.
Change of filter colour alone from white to grey does not indicate the filter
needs changing, rather a thick dust layer does. Do not vacuum or wash pre-
filters, they are made from very high-efficiency material which is not
designed for vacuuming or washing. These actions will damage the pre-filter
and reduce the life of the HEPA filter by allowing dirt to pass through.
Know when to change your main filters.
The HEPA filter will require replacement when the outside, the side
immediately visible underneath the pre-filter, changes color from white to
dark grey – this typically takes some years to occur as long as you have
maintained and changed your pre-filter on a regular basis. Activated carbon
filters, when saturated with chemicals or odors, will leave the air tainted
with an odour. If the air coming out of your purifier develops any sort of
noticeable odor, the carbon filter may require replacement.
When changing pre-filters.
It is best to remove the HEPA filter with the pre-filter intact and take it
outside so no dust is released in your environment when changing. If not
practical to do so you can simply place a large garbage bag over the entire
HEPA filter/pre-filter and remove the pre-filter inside the bag.
Accessing the filters
- Disconnect the power cord.
- Ensure system is sitting on a flat and even surface.
- Pull top of the latches (A) away from the main unit.
- Push the latches back towards the main unit (B)
- Ensure the latch clasps are clear of catches on the base (C).
- Lift casing clear of base to access filters.
Recommended filter replacement intervals
- FILTER NAME APPROXIMATE REPLACEMENT INTERVAL*
- Pre-Filter (Wrap-around) 3-6 months
- H13 HEPA Filter 3-5 years
- 6kg Activated Carbon Filter Maximum 3 years
- Based on 60% daily usage in environments with average particulate/chemical levels. Operating conditions will vary based on levels of dust, chemicals & odours present, and system proximity to major pollution sources each of which may lower any of the filter lifespans. InovaAir does not warranty consumable filter life.
When to replace the filters
-
The pre-filter is the initial stage of filtration, filtering large dust particles right down to ultra-fine sub-micron particles. It is made from a patented material used in respirators and face masks.
On average the pre-filter is designed to last up to 6 months of continuous use. Dust levels in the ambient air will affect how long the pre-filter will last. Pre-filters are white in colour and will turn grey fairly quickly within 1-2 weeks of use, this is nothing to be concerned about and simply means the filter is doing its job. We recommend checking the dust buildup on the pre- filter every 3 months of use. When the dust layer is approximately 2 mm thick the pre-filter should be replaced. -
The H13 HEPA filter is designed to last 3 to 5 years under normal use. As with other filters, the environment in which it is used will determine the filter life. The outside of the HEPA filter will change color and turn dark grey when it needs changing. Generally for the first two years of use the filter will remain white and then gradually get darker in the final months of its life. Please note, that the inside of the HEPA filter will always remain white so it is important to check the outside of the filter which is visible when the Pre-filter is being changed.
-
The E20 6kg activated carbon filter adsorbs chemicals, gases and odors from the air and, depending on the environment, will last up to 3 years. Carbon filters should be changed when they are saturated, this means the filter has entirely filled up with what it has filtered from the air during use. You can tell when a carbon filter needs changing because the air coming out of the air purifier will either be tainted with an odor of what it has absorbed during use, or the air will simply stop smelling clean or smell stale.
When changing pre-filters
It is best to remove the HEPA filter with the pre-filter intact and take it
outside so no dust is released into the environment when changing. If not
practical to do so, you can simply place a large garbage bag over the entire
HEPA filter/pre-filter and remove the pre-filter inside the bag. If you suffer
from dust allergies, we recommend moving the system outside before removing
the pre-filter to avoid the possibility of dust being released in your
environment. Alternatively, wear a dust mask if performing this operation
inside. Important: Do not attempt to vacuum the HEPA or Pre-filter as this
will damage the fine filter fibers and reduce efficiency. Air intake vents on
the sides of the system can be vacuumed including the base plate which sits
under the filters.
Replacing filters
Ordering new filters
Replacement filters can be ordered from the InovaAir website using the URL or QR code below. www.inovaairpurifiers.com.au/replacement-filters
System warranty
Definitions
In this warranty: “ACL” refers to the Australian Consumer Law . “Back to Base”
means where delivery to and collection of your product from the Service Agent
is your responsibility. “Consumable” includes (without limitation) filters and
pre-filters. “InovaAir® Australia” means InovaAir® Australia Pty Ltd ACN 103
549 435. “Factory Second” means a Product sold by InovaAir® Australia or any
other authorised person as a ‘second’ meaning a product with a small
imperfection that does not impede functioning. “Genuine” means manufactured by
or on behalf of InovaAir® Australia. “Product” means a Genuine Product
supplied new by InovaAir® Australia. “Purchase Date” means the date of first
purchase from InovaAir® Australia or any other authorised person seller or
distributor. “Any other authorised person” means a dealer, reseller or
retailer of the Product. “Service Agent” means an authorized InovaAir®
Australia service agent. “You” means the End User and “your” has a
corresponding meaning.
Introduction
Subject to these conditions, InovaAir® Australia Pty Ltd offers this Warranty
on a Product
-
This Warranty applies in addition to the conditions and warranties implied by the Act in relation to a Product.
-
Any other authorized person who has sold a Product to you has acted as principal and has no authority to give any additional warranty or guarantee in relation to the Product on behalf of InovaAir® Australia.
-
InovaAir® Australia will not be liable for any consequential loss, indirect or special damage arising from your use of the Product. In particular (but without limitation) InovaAir® Australia excludes any liability for actual or expected revenue loss or other loss.
NB. This exclusion is subject to any relevant Commonwealth or state law, which is intended to override such exclusions. -
In no event shall InovaAir® Australia, its agents, employees, or distributors be liable for special, incidental, consequential, or indirect damages.
-
The provisions of this warranty supersede and are in lieu of any other
warranty, whether express or implied, written or oral, including any warranty of merchantability or fitness for a particular purpose.
NB. This exclusion is subject to any relevant Commonwealth or state law, which is intended to override such exclusions. -
Maximum liability shall not exceed the actual purchase price paid for this product.
-
This warranty is non-transferable.
-
Should any of the conditions of the warranty be deemed unenforceable then same shall be severable from the balance of warranty conditions, which shall remain legally binding.
Year warranty
InovaAir® Australia warrants that your Product will be free from defects in
materials or workmanship for five (5) year/s from your Purchase Date. One (1)
year in commercial applications).
At its discretion, InovaAir® Australia will repair or replace your Product, if
it is found be defective. InovaAir® Australia will, if it deems the unit
defective, either repair or replace the unit at its sole option (and, based on
availability, may elect to replace the unit with an air purifier of similar
function or value). To make a Warranty claim, you must:
- First call InovaAir® Australia’s Contact Centre on 1 300 137 244;
- Return the Product (if warranty service is required) in its original packaging (or suitable alternative) to a Service Agent, as discussed with the Contact Centre; and
- Provide a copy of your purchase receipt, to show that this Warranty applies to your Product at the date of your claim.
You are responsible for the cost of and risk in delivery of your Product to and its collection from the Service Agent.
Warranty application
This Warranty applies only:
- To a Product that is supplied new to You by InovaAir® Australia or by any other authorized person;
- If you use the Product for your own private or business purposes; and
- You have not bought the Product for resale.
Warranty exclusions
This Warranty will not apply if during the warranty period:
- A Product’s serial number or any rating label is removed or changed in any way; This warranty shall immediately become void if the unit’s serial number label is removed, altered, or is no longer clearly legible;
- A Product is repaired other than by a Service Agent;
- You use a Product contrary to any technical or operating environment or safety guidelines recommended in its user guide or manual;
- No fault is found in service calls where the perceived problem is explained within the Operating Manual or the troubleshooting section of the operating manual.
- This Warranty does not cover costs associated with delivery, handling, freighting, or damage to product in transit.
- This Warranty does not apply to a Product’s malfunction or failure resulting from:
- Deliberate or accidental damage;
- Rust or damage to paintwork, varnishes, or seals caused by a corrosive atmosphere;
- Vermin infestation;
- Any modification by the purchaser which affects the reliability or performance of the unit is not attributable to faulty manufacture, parts, and labor;
- here a unit is installed incorrectly by the purchaser or its servant’s agents employees or by unqualified persons;
- Failure is due to improper installation or faulty installation;
- Failure is due to improper maintenance by the customer (refer to the maintenance section of Operating Instructions);
- Misuse, abuse, or neglect;
- Incorrect voltage or a power surge; or
- Your use of any non-genuine Consumables parts accessories or interfacing;
- Failure to remove or replace the out-of-date or non-functioning filter.
- This warranty covers only manufacturing defects, and not normal wear and tear, including filters which are considered consumables.
- InovaAir® does not warrant the Product as a health safety device. The product is not a Medical Device or Therapeutic Device as defined by the Therapeutic Goods Act 1989.
- All exclusions as determined by InovaAir® Australia at its sole discretion.
- Filter life: InovaAir® does not warrant the useful life of filter consumables. The filter consumables working life will depend entirely on the environments in which it is used. In dusty environments, filter life will be reduced. The Products and their filters are not intended to be used for dust extraction in industrial or commercial applications.
Non-genuine items
InovaAir® Australia advises that if you use non-Genuine Consumables,
replacement parts or accessories, you may damage your Product and may void
your warranty.
Australian Consumer Law
In addition to your rights under the InovaAir® guarantee, we also provide the
following statement as required by the Australian Consumer Law: In Australia,
your InovaAir® appliance comes with statutory guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have your InovaAir®
appliance repaired or replaced if it fails to be of acceptable quality and the
failure does not amount to a major failure.