INOVAAIR AirClean DE20 Plus Air Purifier User Manual
- June 5, 2024
- INOVAAIR
Table of Contents
- INOVAAIR AirClean DE20 Plus Air Purifier
- Introducing your InovaAir® AirClean system
- How your AirClean system works
- Positioning Your AirClean System
- The digital controller
- InovaSmartTM Digital Controller
- Monitoring filter replacement
- System operation
- Tips for getting the most out of your Air Purifier
- Accessing the filters
- When to replace the filters
- Replacing filters
- Ordering new filters
- System warranty
- Introduction
- 5-year warranty
- Warranty application
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INOVAAIR AirClean DE20 Plus Air Purifier
Important safety instructions
Please read these instructions before operating the InovaAir® System and keep for future reference.
To reduce the risk of fire, electric shock, or injury
- Do not detach the motor-outlet module until the system has been switched off.
- Disconnect power, or unplug, before cleaning, performing any maintenance or replacing a filter.
- Use caution when moving the air purifier to avoid injury. We advise removing the filters prior to lifting or transporting the system.
- Do not operate unless all components are fully assembled, securely latched and in the upright position. Failure to do so may result in serious injury.
- Leave a distance of at least 150mm between the appliance and the nearest wall to allow for adequate air circulation.
- Always keep air intake and outlet of the unit unobstructed.
- Do not use near water or moisture or the immediate surroundings of a bath, shower, or swimming pool.
- Do not immerse the air purifier in water or any other liquid.
- Do not let objects, or liquid, enter the product.
- Do not handle any part of the appliance or plug with wet hands.
- Clean only with a dry cloth.
- Do not install near any heat sources.
- Do not operate this appliance if it has a damaged cord or plug, is not working correctly, or has been dropped.
- Do not use this appliance if it has been damaged or submerged in water.
- The appliance is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- If the supply cord is damaged, it must be replaced with a new cord. Contact our support team for a replacement.
- Keep power cord away from heated surfaces.
- Refer all servicing to qualified InovaAir® service personal. Servicing is required when the product has been damaged in any way. Do not attempt to service this product yourself. Opening or removing covers may expose you to dangerous voltages or other hazards and may void warranty.
- Unplug the air purifier during lightning storms or when unused for long periods.
- Do not use this appliance as sole protection against harmful pollutants.
- Do not use outdoors.
- Keep the appliance away from flammable liquids, vapours, air fresheners and essential oils.
- Do not use in explosive or flammable environments.
- Use only on solid, horizontal, and stable surfaces.
Introducing your InovaAir® AirClean system
Inside the E7 box, you will find the InovaAir® unit consisting:
- E7 System Case/Motor
- Filter Base Plate (detachable)
- Power Cable (located in base of the box)
- E7 Pre-filter (pre-installed)
- E7 HEPA Filter (pre-installed)
- E7 Activated Carbon Blanket (pre-installed)
NOTE: Please ensure the two latches at the base of the unit are engaged BEFORE moving or lifting system, failure to do so may result in injury.
How your AirClean system works
- Air is drawn into the system through the sides of the unit.
- Air passes through the dust pre-filter.
- Air passes through the H13 HEPA filter which removes dust, allergens and sub-micron fine particle matter.
- Chemicals and odours are removed from the air in the final stage by the Activated Carbon filter.
- The purified air is then returned to the room via the high air-flow diffuser.
Positioning Your AirClean System
There are two main points to consider: where you spend your time and where the
main pollutants are.
The longer you keep your InovaAir® in a single room, the cleaner the air in
that room will be. As with a heater or air conditioner, the InovaAir® purifier
will only be effective if windows are closed during operation.
Your InovaAir® Airclean works best when it has plenty of unrestricted airflow
around it.
It is also important to make sure the Air Purifier has easy access to a power
outlet as long cords can be a tripping hazard and may result in damage to the
unit should it be knocked over.
The digital controller
Connect the power cord supplied to the power cord inlet on the back of the unit, switch the Main Power On/Off Switch to ON. The system will initiate startup power cycle and all LEDS will illuminate momentarily.
InovaSmartTM Digital Controller
Designed for intuitive operation the digital interface on your InovaAir system continuously keeps track of filter life by monitoring system usage based on hours of use and speed of the fan during operation.
-
FILTER CHECK
Filter Life indicator lights will illuminate separately when the “Filter Check” button is pressed and a number will appear in the LED display showing how many month(s) of life each filter has remaining.
Filter longevity based on 24 hour usage: Pre-filter: 6 months; HEPA Filter: 36 Months; 6kg Activated Carbon Filter: 36 Months.
Please note. The filter replacement intervals are calculated based on the current fan speed. Running the system at higher fan speeds will result in a reduced replacement
interval. -
EXPRESS CLEAN
When pressed this allows the user to preselect maximum speed for a period of between 15-90 minutes, using the fan speed control buttons (4), in 15 minute increments. After the set period elapses the system will resume to the previously set speed. -
NIGHT MODE
Turns off all LED lights to improve sleeping conditions (except night mode LED which is dimmed). -
FAN SPEED
Allows precise control of fan speed, levels 1 through 20, and increases time increments (express clean). -
LED DISPLAY
This functions as the main display for the system numerically, showing: speed, filter life and Express Clean status. -
FAN SPEED INDICATOR
LED bar increases with fan speed as a visual indicator of speed in addition to the numeric display.
Monitoring filter replacement
FILTER NAME | FACTORY DEFAULT SETTING |
---|---|
Pre-Filter (Wrap-around) | 6 months |
H13 HEPA Filter | 36 months |
Inner Activated Carbon Filter | 36 months |
FILTER CHECK
Press “Filter Check” button once and filters PRE-FILTER, HEPA or CARBON illuminate (illustration shows HEPA as example only) in sequence and display the remaining life of each filter. Filter life is displayed in months based on the current fan speed.
STANDARD FILTER LIFE RESET When the filter light illuminates (illustration shows HEPA as example only) for the filter you are wanting to replace, press and continuously hold “Filter Check” for 5 seconds, the display screen will start to flash. When the flashing stops, filter life has been reset to factory default above.
CUSTOMISING FILTER REPLACEMENT INTERVALS
To increase or decrease filter life to a custom setting, press “Filter
Check” button once to select the filter life to customise (illustration shows
HEPA as example only). Press and “Filter Check” button when the filter to be
chan luminated
( NOTE: CONTINUE TO HOLD THROUGHOUT THIS ENTIRE ADJUSTMENT PROCESS).
Once initial flashing has stopped use the “Fan Speed” buttons to increase or
decrease the filter life in months. When the desired number of months are
displayed, continue to hold down “Filter Check” button, the display will flash
again for 5 seconds to indicate the new setting has been saved as your
preferred ault filter life. (To revert to factory defaults see item 2
procedure above)
CUSTOM FAN SPEED FOR NIGHT MODE
Default night mode is set to speed 5, to set a custom fan speed for “Night Mode,” use the arrows to adjust the fan to the desired number. Then hold the “Night Mode” button for at least 5 se hen released the display will show “I II I” to confirm the t speed.
System operation
Speed Control
The system has a variable speed controller and uses an energy efficient
European AC fan. Power consumption is relative to the selected speed
.
The higher the speed, the more times per hour the air in your living space
will be cleaned, so it is recommended to run the system at the highest speed
you are comfortable with.
Higher fan speeds will generate higher sound levels. Generally for sleeping,
an ideal setting is position 1-2.
Tips for getting the most out of your Air Purifier
Always operate the system with windows closed.
Air purifiers are not designed to filter the great outdoors, like an air
conditioner or heater leaving a window open will render the system
ineffective. Use of evaporative coolers will also reduce effectiveness.
Operate the system 24/7.
As dust, allergens, and chemicals are always present in the air, for maximum
effectiveness you should operate the system continuously. By switching the
system off you are only allowing these contaminants to build up in the interim
until it is switched back on. InovaAir systems are designed for optimal energy
efficiency – so don’t be concerned about power consumption as this will barely
be noticeable on an electricity bill.
Decide where you need clean air the most.
Typically for allergy and asthma sufferers, use while sleeping will be an
important part of how you use your air purifier. If you have a high capacity
system with adequate coverage, it can be moved between living areas during the
day and the bedroom at night. Operation for 15-30mins on high speed will
dramatically reduce the bulk of airborne particulates when moving into a new
room.
Enclose the area where you are operating the system.
If you close a bedroom door the system will be much more effective as it will
only be filtering air in the one room. If you move to larger areas, if
possible, close off surrounding areas to maintain clean air in that space. E7
and E8 models are designed primarily for bedroom use, while the high capacity
E20 series are designed to cover large living areas and be moved to bedrooms
for night-time use.
Operate at the highest speed you are comfortable with.
All InovaAir systems include variable speed controls and the speed should be
varied depending on the room size, the level of air pollutants present, and
the sensitivity of the individual. The higher the operating speed the more
effective the system will be, as the purifier will be filtering the air more
times every hour resulting in lower levels of particles and certain chemicals.
When operating smaller systems in larger areas, increase the operating speed
to enable the system to filter the air more effectively.
Activated carbon filters.
While they are highly efficient at removing chemicals and odours, if you have
high levels of any chemicals or odours they will absorb these from the air
quickly and the filter life will be reduced. If you want to prolong the life
of the activated carbon filter, you should turn the system off while cooking
or if there are any heavy transient odours.
Check your pre-filters regularly for dust build-up.
We recommend that you check your pre-filter after every three months of
operation to visually inspect the level of dust buildup. Pre-filters typically
last between 4 to 6 months based on average dust levels in a home environment.
If the levels of dust in your home are high due to external factors such as
living near a main road, you may need to change your filters more regularly.
Change of filter colour alone from white to grey does not indicate the filter
needs changing, rather a thick dust layer does. Do not vacuum or wash pre-
filters, they are made from very high efficiency material which is not
designed for vacuuming or washing. These actions will damage the pre-filter
and reduce the life of the HEPA filter by allowing dirt to pass through.
Know when to change your main filters.
The HEPA filter will require replacement when the outside, the side
immediately visible underneath the pre-filter, changes colour from white to
dark grey – this typically takes some years to occur as long as you have
maintained and changed your pre-filter on a regular basis. Activated carbon
filters, when saturated with chemicals or odours, will leave the air tainted
with an odour. If the air coming out of your purifier develops any sort of
noticeable odour, the carbon filter may require replacement.
When changing pre-filters.
It is best to remove the HEPA filter with the pre-filter intact and take
outside so no dust is released in your environment when changing. If not
practical to do so you can simply place a large garbage bag over the entire
HEPA filter/pre-filter and remove the pre-filter inside the bag.
Accessing the filters
- Disconnect the power cord.
- Ensure system is sitting on a flat and even surface.
- Pull top of the latches (A) away from the main unit.
- Push the latches back towards the main unit (B)
- Ensure the latch clasps are clear of catches on the base (C).
- Lift casing clear of base to access filters.
Recommended filter replacement intervals
FILTER NAME | APPROXIMATE REPLACEMENT **INTERVAL*** |
---|---|
Pre-Filter (Wrap-around) | 3-6 months |
H13 HEPA Filter | 3-5 years |
Inner activated carbon blanket | 6-12 months |
Based on 60% daily usage in environments with average particulate/chemical
levels.
Operating conditions will vary based on levels of dust, chemicals & odours
present, and system proximity to major pollution sources each of which may
lower any of the filter lifespans. InovaAir does not warranty consumable
filter life.
When to replace the filters
Stage 1: Pre-filter
The pre-filter is the initial stage of filtration, filtering large dust
particles right down to ultra-fine sub-micron particles. It is made from a
patented material used in respirators and face masks.
On average the pre-filter is designed to last up to 6 months of continuous
use. Dust levels in the ambient air will affect how long the pre-filter will
last.
Pre-filters are white in colour and will turn grey fairly quickly within 1-2
weeks of use, this is nothing to be concerned about and simply means the
filter is doing its job.
We recommend checking the dust buildup on the pre-filter every 3 months of
use. When the dust layer is approximately 2 mm thick the pre-filter should be
replaced.
Stage 2: Medical-grade HEPA filter
The H13 HEPA filter is designed to last 3 to 5 years under normal use. As with
other filters the environment in which it is used will determine the filter
life.
The outside of the HEPA filter will change colour and turn dark grey when it
needs changing. Generally for the first two years of use the filter will
remain white and then gradually get darker in the final months of its life.
Please note, the inside of the HEPA filter will always remain white so it is
important to check the outside of the filter which is visible when the Pre-
filter is being changed.
Stage 3: Final stage activated carbon filter
The E7 impregnated carbon blanket filter is designed for light-duty
use and will last approx. 6-12 months. Activated carbon filters work like
sponges by adsorbing chemicals, gases and odours from the air.
Carbon filters should be changed when they are saturated, this means the
filter has entirely filled up with what it has filtered from the air during
use. You can tell when a carbon filter needs changing because the air coming
out of the air purifier will either be tainted with an odour of what it has
absorbed during use, or the air will simply stop smelling clean or smell
stale.
When changing pre-filters
It is best to remove the HEPA filter with the pre-filter intact and take it
outside so no dust is released into the environment when changing. If not
practical to do so, you can simply place a large garbage bag over the entire
HEPA filter/pre-filter and remove the pre-filter inside the bag.
If you suffer from dust allergies, we recommend moving the system outside
before removing the pre-filter to avoid the possibility of dust being released
in your environment. Alternatively wear a dust mask if performing this
operation inside.
Important: Do not attempt to vacuum the HEPA or Pre-filter as this will
damage the fine filter fibres and reduce efficiency.
Air intake vents on the sides of the system can be vacuumed including the base
plate which sits under the filters.
Replacing filters
Ordering new filters
Replacement filters can be ordered from the InovaAir website using the URL or
QR code below.
www.inovaairpurifiers.com.au/replacement-
filters
System warranty
Definitions
In this warranty:
“ACL” refers to the Australian Consumer Law. “Back to Base” means where
delivery to and collection of your product from the Service Agent is your
responsibility.
“Consumable” includes (without limitation) filters and pre-filters. “InovaAir®
Australia” means InovaAir® Australia Pty Ltd ACN 103 549 435. “Factory Second”
means a Product sold by InovaAir® Australia or any other authorised person as
a ‘second’ meaning a product with a small imperfection that does not impede
functioning. “Genuine” means manufactured by or on behalf of InovaAir®
Australia. “Product” means a Genuine Product supplied new by InovaAir®
Australia. “Purchase Date” means the date of first purchase from InovaAir®
Australia or any other authorised person seller or distributor. “Any other
authorised person” means a dealer, reseller or retailer of the Product.
“Service Agent” means an authorized InovaAir® Australia service agent. “You”
means the End User and “you’re” has a corresponding meaning.
Introduction
Subject to these conditions, InovaAir® Australia Pty Ltd offers this Warranty on a Product to which it’s Back to Base service applies.
-
This Warranty applies in addition to the conditions and warranties implied by the Act in relation to a Product.
-
Any other authorized person who has sold a Product to you has acted as principal and has no authority to give any additional warranty or guarantee in relation to the Product on behalf of InovaAir® Australia.
-
InovaAir® Australia will not be liable for any consequential loss, or indirect or special damage arising from your use of the Product. In particular (but without limitation) InovaAir® Australia excludes any liability for actual or expected revenue loss or other loss.
NB. This exclusion is subject to any relevant Commonwealth or state law, which is intended to override such exclusions. -
In no event shall InovaAir® Australia, its agents, employees, or distributors be liable for special, incidental, consequential, or indirect damages.
-
The provisions of this warranty supersede and are in lieu of any other
warranty, whether express or implied, written or oral, including any warranty of merchantability or fitness for a particular purpose.
NB. This exclusion is subject to any relevant Commonwealth or state law, which is intended to override such exclusions. -
Maximum liability shall not exceed the actual purchase price paid for this product.
-
This warranty is non-transferable.
-
Should any of the conditions of the warranty be deemed unenforceable then the same shall be severable from the balance of warranty conditions, which shall remain legally binding.
5-year warranty
InovaAir® Australia warrants that your Product will be free from defects in
materials or workmanship for five (5) year/s from your Purchase Date. One (1)
year in commercial applications).
At its discretion, InovaAir® Australia will repair or replace your Product, if
it is found be defective. InovaAir® Australia will, if it deems the unit
defective, either repair or replace the unit at its sole option (and, based on
availability, may elect to replace the unit with an air purifier of similar
function or value).
To make a warranty claim, you must:
- First, call InovaAir® Australia’s Contact Centre on 1 300 137 244;
- Return the Product (if warranty service is required) in its original packaging (or a suitable alternative) to a Service Agent, as discussed with the Contact Centre; and
- Provide a copy of your purchase receipt, to show that this Warranty applies to your Product at the date of your claim.
You are responsible for the cost of and risk in delivery of your Product to and its collection from the Service Agent.
Warranty application
This Warranty applies only:
- a. To a Product that is supplied new to You by InovaAir® Australia or by any other authorized person;
- b. If you use the Product for your own private or business purposes; and
- c. You have not bought the Product for resale.
Warranty exclusions
This Warranty will not apply if during the warranty period:
- A Product’s serial number or any rating label is removed or changed in any way; This warranty shall immediately become void if the unit’s serial number label is removed, altered, or is no longer clearly legible;
- A Product is repaired other than by a Service Agent;
- You use a Product contrary to any technical or operating environment or safety guidelines recommended in its user guide or manual;
- No-fault found service calls where the perceived problem is explained within the Operating Manual or the trouble shooting section of the operating manual.
- This Warranty does not cover costs associated with delivery, handling, freighting or damage to product in transit.
- This Warranty does not apply to a Product’s malfunction or failure resulting from:
- Deliberate or accidental damage;
- Rust or damage to paintwork, varnishes or seals caused by a corrosive atmosphere;
- Vermin infestation;
- Any modification by the purchaser which affects the reliability or performance of the unit, not attributable to faulty manufacture, parts and labour;
- Where a unit is installed incorrectly by the purchaser or its servant’s agents employees or by unqualified persons;
- Failure is due to improper installation or faulty installation;
- Failure is due to improper maintenance by the customer (refer to the maintenance section of Operating Instructions);
- Misuse, abuse or neglect;
- Incorrect voltage or a power surge; or
- Your use of any non-genuine Consumables parts accessories or interfacing;
- Failure to remove or replace out of date or non-functioning filter.
- This warranty covers only manufacturing defects, and not normal wear and tear, including filters which are considered consumables.
- InovaAir® does not warrant the Product as a health safety device. The product is not a Medical Device or Therapeutic Device as defined by the Therapeutic Goods Act 1989.
- All exclusions as determined by InovaAir® Australia at its sole discretion.
- Filter life: InovaAir® does not warrant the useful life of filter consumables. The filter consumables working life will depend entirely on the environments in which it is used. In dusty environments, filter life will be reduced. The Products and their filters are not intended to be used for dust extraction in industrial or commercial applications.
Non-genuine items
InovaAir® Australia advises that if you use non-Genuine Consumables,
replacement parts or accessories, you may damage your Product and may void
your warranty.
Australian Consumer Law
In addition to your rights under the InovaAir® guarantee, we also provide the
following statement as required by the Australian Consumer Law: In Australia,
your InovaAir® appliance comes with statutory guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have your InovaAir®
appliance repaired or replaced if it fails to be of acceptable quality and the
failure does not amount to a major failure.
- InovaAir Australia Pty Ltd Unit 8, 1
- Reliance Drive, Tuggerah, NSW 2259 Australia
- TEL: 1300 137 244
- www.airclean.com.au
References
Read User Manual Online (PDF format)