Methane (CH4) Gas Detector
Item no: 2483186sygonix 2483186 Methane Gas Detector - QR
codehttp://www.conrad.com/downloads

Intended use

The product is a standalone methane (CH4) gas detector. The product will constantly monitor gas levels and sound an alarm when combustible gas is detected.

Important:

  • This product will not detect other types of gases, steam, heat, or smoke.
  • This product cannot prevent explosions. It is only a warning indicator signaling a gas leakage.
  • When the end-of-service light indicator [Yellow: Service life] lights up, disconnect the power supply, remove the product from us, and then replace it with a new one.
  • Standard implemented: EN 50194-1:2009.

The product is designed for private use only.
The product is intended for indoor use only. Do not use it outdoors.
Contact with moisture must be avoided under all circumstances.
If you use the product for purposes other than those described, the product may be damaged.
Improper use can result in short circuits, fires, electric shocks, or other hazards.
The product complies with the statutory national and European requirements.
For safety and approval purposes, you must not rebuild and/or modify the product.
Read the operating instructions carefully and store them in a safe place. Make this product available to third parties only together with the operating instructions.
All company names and product names are trademarks of their respective owners. All rights reserved.

Delivery contents

■ Product
■ 2x Screws
■ 2x Dowels
■ Mounting bracket
■ Operating instructions

Latest product information

Download the latest product information at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.

Symbols in this document

The symbol warns of hazards that can lead to personal injury. Read the information carefully.
The symbol warns of dangerous voltage that can lead to personal injury by electric shock. Read the information carefully.

Symbols on the product

Protection class 2 (double or reinforced insulation, protective insulation).
Read the operating instructions carefully.

 Safety instructions

Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.

6.1 General

  • The product is not a toy. Keep it out of the reach of children and pets.
  • Do not leave packaging material lying around carelessly. This may become dangerous playing material for children.
  • If you have questions that remain unanswered by this information product, contact our technical support service or other technical personnel.
  • Maintenance, modifications, and repairs must only be completed by a technician or an authorized repair center.

6.2 Handling

  • Handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.

6.3 Operating environment

  • Do not place the product under any mechanical stress.
  • Protect the appliance from extreme temperatures, strong jolts, steam, and solvents.
  • Protect the product from high humidity and moisture.
  • Protect the product from direct sunlight.

6.4 Operation

  • Consult an expert when in doubt about the operation, safety, or connection of the product.
  • If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. DO NOT attempt to repair the product yourself. Safe operation can no longer be guaranteed if the product:
    – is visibly damaged,
    – is no longer working properly,
    – has been stored for extended periods in poor ambient conditions or
    – has been subjected to any serious transport-related stresses.

6.5 Mains cable

Do not tamper with power supply components. Risk of death by electric shock!

  • Always ensure proper connection.

  • Never use damaged power supply components.

  • Do not modify power supply components.

  • The mains outlet must be located near to the device and be easily accessible.

  • Never plug in or unplug the mains plug when your hands are wet.

  • Never pull the mains plug from the socket by pulling at the cable. Always pull it from the mains socket using the intended grips.

  • Unplug the mains plug from the mains socket if you do not use the device for an extended period of time.

  • Disconnect the mains plug from the mains socket in thunderstorms for reasons of safety.

  • Make sure that the mains cable is not squeezed, bent, damaged by sharp edges, or put under mechanical stress.

  • Avoid excessive thermal stress on the main cable from extreme heat or cold.

  • Do not modify the main cable. Otherwise, the mains cable may be damaged. A damaged mains cable can cause a deadly electric shock.

  • Do not touch the main cable if it is damaged.
    – First, power down the respective mains socket (e.g. via the respective circuit breaker) and then carefully pull the mains plug from the mains socket.
    – Never use the product if the main cable is damaged.

  • A damaged mains cable may only be replaced by the manufacturer, a workshop commissioned by the manufacturer, or a similarly qualified person, so as to prevent any danger.

  • Ensure that cables are not pinched, kinked, or damaged by sharp edges.

  • Always lay cables so that nobody can trip over or become entangled in them. This poses a risk of injury.

6.6 Product
Important:
When the end-of-service light indicator [Yellow: Service life] lights up, disconnect the power supply, remove the product from us, and replace it with a new one.

Product Overview

sygonix 2483186 Methane Gas Detector - overview

1 Power cable 5 Function button
2 Alarm speaker 6 Yellow: Service life LED
3 Mounting bracket 7 Gas detection holes
4 Red: Alarm / Green Power LED

Status indicator lights

Mode| Status LED [Red:
Alarm / Green: Power]| End-of-life LED [Yellow: service life]| Alarm (buzzer)
---|---|---|---
Start-up| Green flashing| –| –
Testing| Red flashing| –| 4x beeps
Normal| Green constant ON| –| –
Fault| Yellow constant ON| –| Constant alarm
Alarm| Red flashing| –| 4x beeps per cycle
End of life| –| Yellow flashing| 3x beeps per cycle

Installation location

Important:
The gas alarm must not be installed:

  • Where conditions exceed the operating range. See the section “Technical data” for further information.

  • Directly above cooking appliances (min. 1-meter clearance).

  • Adjacent to an extractor fan.

  • Directly above sources of water, steam, or heat.

  • Outdoors, near a door, or window.

  • In enclosed places such as behind a curtain or in cupboards.

  • Where excessive dirt or debris may block the gas detection holes.
    sygonix 2483186 Methane Gas Detector - InstallationNatural gas is less dense than air and will rise above the level of escape (e.g., doors, windows) and get trapped below the ceiling.
    The product must be installed above potential gas escapes:

  • Horizontal ceilings: approx.30 cm from the ceiling.

  • Sloped ceilings: approx. 50 cm from the roof ridge.

Installation

Important:

  • If necessary, drill holes and insert wall plugs. WARNING! Risk of electric shock or injury! Before drilling, check for concealed wires or pipes beneath the surface.
  • Risk of electric shock! Always disconnect the product from the power supply when installing or removing it.
  • The product must be connected to a stable power supply.

PRECONDITIONS:
✔ There is a power outlet within range of the power cord.
✔The product is not connected to the power supply.

  1. Use the holes on the mounting bracket as a template to mark where to drill.
  2. Attach the bracket using the supplied dowels and screws.
  3. Hang the product over the mounting bracket. Make sure the product is secure before letting go.

Connection

PRECONDITIONS:
✔ product is mounted in a suitable location.
✔ The power supply has not been connected.

  1. Connect the product to the power supply.
  2. A confirmation tone will sound and the green power LED [Green: Power] will flash for approx. 3 minutes (start-up time).
  3. When the green power LED [Green: Power] is constantly on, the product is ready for use.
  4. Bypass the preheating step and enter detection mode by, short pressing the function button once, then pressing and holding the function button for approx. 10 seconds.

Operation

Important:

  • Avoid spraying air fresheners, hair spray, or other aerosols near the product! This may trigger the alarm.
  • Clean the product regularly to prevent dust build-up. Pay close attention to the gas detection holes. See the section “Cleaning and maintenance”.
  • When the end-of-service light indicator [Yellow: Service life] lights up, disconnect the power supply, remove the product from use, and replace it with a new one.
  • The green power LED [Green: Power] must always be ON. This indicates that the power is ON and everything is functioning correctly.

12.1 Alarm test
It is recommended to test the alarm at least once a month.
Short press the function button, the product will enter a short testing state.
A sound and light alarm will signal if the product is working correctly.
Remove the product from use and contact customer service if the alarms fail to activate.

12.2 Alarm activated
When the methane (CH4) gas levels reach the set alarming point, the detector will enter alarming mode. When this happens:

  • The red alarm indicator [Red: Alarm] will flash.
  • The speaker will sound an alarm.

12.3 Action needed

Important:
The following actions are only suggestions and not in order of operation. The situation at hand may require different protocols. If in any doubt, consult a qualified professional to develop a suitable action plan.

If the alarm has been triggered or the smell of gas is present, remain calm and perform the following actions:

  • Call the fire department from outside the premises.
  • Extinguish open or smoldering flames e.g. candles, and cigarettes.
  • Turn off all gas appliances e.g. gas heater, and gas cooker.
  • Do not switch ON/OFF any electrical equipment, including the gas detector.
  • Turn off the gas supply at the gas main control.
  • Open doors and windows to increase ventilation.
  • Warn all persons and evacuate the premises immediately.
  • Do not use a telephone when explosive gas is present.
  • Do not re-enter the premises until there is no more gas is present.

13 End of service life

Important:
When the end-of-service light indicator [Yellow: Service life] lights up, disconnect the power supply, remove the product from use, and replace it with a new one.

  • The service life of this product is approximately 5 years under normal conditions. Make a note of the installation date.
  • Regular cleaning and maintenance will help prolong use. See the section “Cleaning and maintenance” for further details.

Troubleshooting

Problem Possible cause Suggested solution
The green power indicator [Green: Power] is not on. The power plug was not
connected properly. Check the power connection.
Damaged power indicator light or circuit failure. Contact customer service.
No sound and lights during alarm self-check. Circuit failure Contact

customer service.
No response to methane (CH4) gas leak.| The product still starting up.| Wait approx. 3 minutes.
Circuit failure| Contact customer service.
Continuous alarm| The environment contains cigarette smoke or other volatile organic compounds (e.g., petrol. perfume, banana oil, or paints)| Remove any environmental contaminants.
The product is kept in storage (not used) for a long time.| Power on and wait 2 hrs or more.
Circuit failure| Contact customer service.

Cleaning and maintenance

Important:

  • Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
    They damage the housing and can cause the product to malfunction.

  • Do not immerse the product in water.

Clean the product regularly to prevent dust build-up. Pay close attention to the gas detection holes.

  1. Disconnect the product from the power supply.
  2. Remove the product from the mounting bracket.
  3. Use a vacuum cleaner with a brush attachment on low power to remove dust particles from the front and sides.
  4. Wipe away any remaining dust using a dry, lint-free cloth.

Disposal

Electronic devices are recyclable waste and must not be disposed of in the household waste. At the end of its service life, dispose of the product in accordance with applicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

17 Technical data
Input ……………………………………… 100–240 V/AC 50-60 Hz
Power consumption ………………….. ≤4 W
Protection class ……………………….. II
Response time…………………………. ≤30 sec
Natural gas detected ………………… Methane (CH4)
Sensor life……………………………….. 5 years (typical value)
Sensor type …………………………….. Semiconductor
Alarm sensitivity……………………….. 7 % (±3 %) LEL (lower explosive limit)
Alerts ……………………………………… Sound, light
Alarm sound level …………………….. ≥85 dB (1 m ahead)
Standard …………………………………. EN 50194-1:2009
Power cord ……………………………… 1.5 m
Ambient pressure …………………….. 86 to 106 kPa
Operating conditions…………………. 0 to +55 °C, <95 % RH (non-condensing)
Storage conditions……………………. -25 to +55 °C, <95 % RH (non-condensing)
Dimensions (W x H x D) (approx.) 86 x 112 x 34 mm
Weight (approx.) ……………………… 203 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2483186_V1_1221_dh_mh_en I1/O1

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals