SAFETY REGULATIONS
Attention! This user manual is an essential part of this product. The user manual should be read carefully before you use the product for the first time. If the product is given to someone for temporary use, be sure to enclose the user manual to it.
- Do not misuse the product.
- Do not remove warning signs and protect them from abrasion, because they contain information about the safe operation of the product.
Laser radiation!
Do not stare into beam Class 2 laser <1 mW 635-670nm EN60825-1: 2007-03
- Do not look into the laser beam or its re-econ, with an unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- Do not let unauthorized people enter the zone of product operation.
- Store the product beyond the reach of children and unauthorized people.
- It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
- Do not use the product in an explosive environment, close to amiable materials.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with the eyes, fuse clean water for 10 minutes and consult the doctor.
FUNCTIONS/APPLICATIONS
IR-thermometer TM0300 is designed for non-contact measurement of the surface
temperature of various objects. Ergonomic, shockproof housing, small size and
weight, intuitive interface, laser spot marking, and continuous measurement
mode provide a simple and convenient measurement of the temperature of
dangerous, moving, hard-to-reach distant objects in less than 1 second at just
one touch of the trigger.
The principle of non-contact temperature measurement is based on measuring the
intensity of infrared radiation on the object’s surface.
DELIVERY PACKAGE
Infrared thermometer – 1pc.
Battery (1,5V LR6 AA) – 1 pc.
User manual – 1 pc.
TECHNICAL SPECIFICATIONS
Display | 30*30mm LCD with | backlight |
---|---|---|
Surface temperature range | -50 °C to 600 °C | |
-58 °F to 1112 °F | ||
Surface temperature accuracy | -50 °C to -20 °C |
(-58 °F to -4 °F)
-20 °C…0 °C
(-4 °F…32 °F)0
°C to 600 °C
(32 °F to 1112 °F)| ±3 °C (±6 °F)
±2 °C (±4 °F)
±1,5 °C (±3 °F)
or ±1,5%
Surface operation temperature| 0 °C to 50 °C (32 °F to 122 °F)
---|---
Body temperature range| 32 °C to 42 °C
Body temperature accuracy| +/-0.3°C(+/-0.6°F) 89.6°F to 107.6°F
Body operation temperature| 10 °C to 40 °C (50 °F to 104 °F)
Body Measurement distance| 5cm (T.B.D)
Smallest unit displayed| 0.1 °C/°F
Optical resolution| 12:01
---|---
Response time| 0,1 sec
Spectral sensitivity| 8 to 14 µm
Emissivity| 0.1 to 1.00 adjustable
Storage temperature| -10° to 60° (-14 °F to 140 °F)
Relative humidity for| <95%
Power supply| 1,5V LR6 alkaline
Battery life| ~6 hours
Automatic shutdown| 30 sec.
Laser| Class II, 635-670nm, <1mW
Dimensions| 1654759mm
Weight| 135 g
PRODUCT DESCRIPTION
- Display
- Keyboard
- Trigger
- Laser spot marking exit window
- Infrared sensor
Battery cover
Display
- Indication of continuous measurement
- Emissivity value
- Indication of battery charge level
- Measuring units (°C or °F
- Maximal/minimal measurement value
- Indication of maximal/minimal value
- Indication of activated laser spot marking
- Measurement result
- Surface Temperature Mode / Body Temperature Mode
Keyboard
| • Check max/min values/adjust emissivity degree.
---|---
| • Switch on/of display backlight and laser spot marking.
| • Select measuring unit (°f or °F)/adjust emissivity degree.
INSTALL/REPLACE BATTERIES
Remove the battery cover. Install the battery observing correct polarity. Put
the battery cover back and push it until a click is heard.
If the symbol of a low battery charge level appears on the display, replace the battery with a new one.
SWITCH ON/OFF
Short press the trigger to switch on the device. The device is ready to work.
The device switches automatically 30 seconds after the last pressing of any
button.
SURFACE TEMPERATURE MODE
It is used to measure the surface temperature of the targeted object.
-
Measure the object’s temperature
– Press the [Measure] key to measure the surface temperature of the targeted object.
The HOLD icon is OFF, and the temperature is updated every second.
– Release the [Measure] key to stop the measurement. The HOLD icon appeared. -
Switch between Min/Max Temperature
– Press the [Min/Max] key to switch the lower display for MAX Temp and MIN Temp -
To turn on or off the laser
– Press the [Laser] key to turn ON or OFF the laser function. -
To change the temperature unit
– Press the [C/F] key to toggle the unit of temperature. -
To adjust Emissivity
– Press the [Laser + Measure] key to enter emissivity adjustment mode.
– Press [Min/Max] to increase the emissivity value
– Press [C/F] to decrease the emissivity value
– If there is no keypress for 5sec, it will exit the emissivity adjustment mode.
BODY TEMPERATURE MODE
HUMAN HEAD ICON ON, LASER ICON OFF
-
To change to Body temperature Mode
– Press and hold the [Laser] key for 2 sec to change to Body temperature mode.
– The Human head icon appeared. The laser icon is OFF. -
Measure the object’s temperature
– Press the [Measure] key to measure the body temperature. The HOLD icon is OFF, the
temperature is updated every second.
– Release the [Measure] key to stop the measurement. The HOLD icon appeared. -
To set the temperature alert
( Note. When a measured temperature is higher than set value, the alert will be the numbers on the screen flashing)
– Press the [Laser] key to change to alert settings. In this mode, the number on the screen will be flashing and there will be “AL” displayed.
– Press [Min/Max] to increase the value
– Press [C/F] to decrease the value -
Switch between Min/Max Temperature
– Press the [Min/Max] key to switch the lower display for MAX Temp and MIN Temp -
To change the temperature unit
– Press the [C/F] key to toggle the unit of temperature.
EMISSIVITY
All objects emit thermal energy. Emitted energy quantity depends on the surface temperature and object emissivity. The product can measure emissions on the surface of the object and calculate object temperature. Objects with different surfaces but with the same temperature can emit a different quantity of thermal energy. Many objects (e.g. coated metal, wood, water, skin, and texture) possess high emissivity (0,9 and more), and emit more energy than glossy surfaces and uncoated metal because of their emissivity is less than 0,6. Adjustment of emissivity helps to take this feature into consideration and minimize inaccuracy of temperature measurement.
Material | Emissivity | Material | Emissivity |
---|---|---|---|
Asphalt | 0.90~0.98 | Black cloth | 0.98 |
Concrete | 0.94 | Human skin | 0.98 |
Cement | 0.96 | Bubble | 0.75~0.80 |
Sand | 0.9 | Charcoal dust | 0.96 |
Soil | 0.92~0.96 | Paint | 0.80~0.95 |
Water | 0.92~0.96 | Matte paint | 0.97 |
Ice | 0.96~0.98 | Black rubber | 0.94 |
Snow | 0.83 | Plastic | 0.85~0.95 |
Glass | 0.90~0.95 | Wood | 0.9 |
Ceramic | 0.90~0.94 | Paper | 0.70~0.94 |
Marble | 0.94 | Chromic oxide | 0.81 |
Gypsum | 0.80~0.90 | Copper oxide | 0.78 |
Mortar | 0.89~0.91 | Ferric oxide | 0.78~0.82 |
Brick | 0.93~0.96 | Texture | 0.9 |
8. SWITCH ON THE DEVICE / 9. OPTICAL RESOLUTION / 10. CARE AND MAINTENANCE
Switch on the device.
Press and hold the trigger, then the long-press button . A symbol E will
start flashing on the display. Release the trigger. Value 0.95 is set by
default. Press buttons and to adjust the emission degree E will be fixed
on the display, and the symbol will stop flashing.
OPTICAL RESOLUTION
As the distance from the device to the object increases, the size of the
measured spot on the object surface increases accordingly To determine the
size of the spot (S) divide the
distance from the device to the target (D) by 12.
CARE AND MAINTENANCE
Attention! The product is an accurate optical mechanic device and requires careful handling. Maintenance of the following recommendations will extend the life of the device:
- Keep the product clean and protect it from any bumps, dust, and dampness; do not allow moisture, dust or other dirt to get inside the product.
- Do not expose the product to extreme temperatures.
- If liquids get inside the product first remove the batteries, then contact a service center.
- Do not store or use the product under high humidity conditions for a long time.
- Clean the product with a soft wet cloth.
- Keep the device optics clean and protect it from mechanical impact. Failure to observe the following rules may result in leakage of electrolytes from the batteries and damage to the device.
- Remove the batteries from the product if you do not use it for a long time.
- Do not leave discharged batteries in the device.
UTILIZATION
Expired tools, accessories, and packages should be passed for waste recycling.
Please send the product to the following address for proper recycling:
Do not throw the product in municipal waste!
According to the European directive, 2002/96/EC expired measuring tools and
their components must be collected separately and submitted to environmentally
friendly recycling of wastes.
WARRANTY
All PerfectPrime products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation does not expire.
- PerfectPrime agrees to eliminate all defects in the product, discovered while the warranty period, that represents the defect in material or workmanship in full volume and at its own expense.
- The warranty period is 24 months and starts from the date of purchase by the end customer (see the original supporting document).
- The warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service, insuficient care, or the use of non-original accessories and spare parts. Modifications in the design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, which doesn’t hinder the normal operation of the product.
- PerfectPrime reserves the right to decide on the replacement or repair of the device.
- Other claims not mentioned above, are not covered by the warranty.
- After holding warranty works by PerfectPrime warranty period is not renewed or extended.
- PerfectPrime is not liable for loss of profit or inconvenience associated with a defect of the device, or rental cost of alternative equipment for the period of repair. In the warranty case please return the product to the retail seller or send it with a description of the defect to the following address: cs@perfectprime.com
CUSTOMER SERVICE INQUIRIES
Your emails are important to us so we strive to reply to all inquiries and
emails within 24 hours. In exceptional cases, we may require more time to
respond. Thank you for your understanding. For more information about our
products and services, please send us an email:
cs@perfectprime.com
For B2B or project-based applications, please send an email:
sales@perfectprime.com
FOR MORE INFORMATION ABOUT PERFECT PRIME PLEASE VISIT
OUR ABOUT US PAGE AND FEEL FREE TO BROWSE.
http://qr.w69b.com/g/r4oLxa2l2| http://qr.w69b.com/g/qRw248shO|
http://qr.w69b.com/g/mT0iM63Vm
---|---|---
Scan QR Code for the Youtube channel for video manual| Scan QR Code for the
Product Manual page (Multi-Language available for certain products)| Scan QR
Code to register the product for a 1-year warranty
Tyche Smart Limited cs@perfectprime.com
2nd Floor, 107 Charterhouse Street, EC1M
6HW, London, England UNITED KINGDOM
+44 203 7695377
Retailer…………………………….
Email………………………………..
Address……………………………….
Telephone……………………………..