wiltec 51634 SuperEco Filter Pump User Manual

June 5, 2024
wiltec

51634 SuperEco Filter Pump
User Manual

wiltec 51634 SuperEco Filter Pump

Read and follow the operating instructions and safety information before using it for the first time. Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.

Updating the documentation If you have suggestions for improvement or have found any irregularities, please contact us.

The information contained in this document may be altered at any time without prior notice. Copying or spreading any part of this document in any way without prior written permission is prohibited. All rights reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operation manual, including the diagrams and figures contained within.
Even though the WilTec Wildanger Technik GmbH has undergone the utmost effort to ensure that this operation manual is complete, faultless, and up to date, mistakes cannot be entirely avoided. We are looking forward to hearing from you in case you finding any mistakes or wishing to submit suggestions for improvement.

Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch

Our postal address is:

WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is:

WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us in advance or to place your order via our webshop.

E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

To return orders for exchange, repair, or other purposes, please use the following address. Attention! In order to allow for smooth processing of your complaint or return, it is important to contact our customer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler

E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

Introduction

Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients take some basic safety precautions when using this product. Please read this operation manual carefully and make sure you have understood its content.
Always keep this operation manual safe and accessible.

CAUTION:
On and near standing water, garden, and swimming ponds, use of the unit is only permitted with a residual current circuit breaker with a tripping rated current of up to 30 mA (according to VDE 0100 parts 702 and 738).

The unit is not suitable for use in swimming pools, paddling pools of any kind, and other water bodies in which people may be present during operation. Operation of the unit with people being in the danger zone is not permitted. Consult your electrician!

This device is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge unless they have been given supervision or instruction concerning use of the device by a person responsible for their safety. Children should be supervised to ensure that they do not play with the device.

ATTENTION:

  • Perform a visual inspection of the device before each use. Do not use the device if safety devices are damaged or worn. Never override safety devices.
  • Only use the device in accordance with the intended use specified in these instructions for use.
  • You are responsible for safety in the work area.
  • If the power cord or electrical plug is damaged due to external influences, do not repair the cable but replace it with a new one. This work may only be carried out by a qualified electrician.
  • The voltage of 23o V AC indicated on the unit’s rating plate must correspond to the existing mains voltage.
  • Never lift, transport, or fasten the unit by the power cord.
  • Make sure that the electrical plug connections are protected from moisture and flooding.
  • Always disconnect the plug before working on the unit.
  • Avoid exposing the unit to a direct jet of water or rain.
  • The operator is responsible for compliance with local safety and installation regulations. Consult a qualified electrician if necessary.
  • The user must take suitable measures (e.g., installation of an alarm system, standby pump, etc.) to prevent damage caused by flooding of rooms in the event of a malfunction of the unit.
  • In the event of a failure of the unit, repair work may only be carried out by a qualified electrician.
  • The unit must never run dry or be operated with the intake line completely closed.
  • The unit must not be used for operating swimming pools.
  • The unit must not be installed in the drinking water circuit.

WARNING:
Read all safety notices and instructions. Failure to comply with safety notices and instructions may result in electric shock, fire, and/or serious injury. Keep all safety notices and instructions for future reference.

Resistance

  • The maximum temperature of the pumped liquid should not exceed +35 ℃ in continuous operation.
  • Avoid pumping aggressive liquids (of acids, alkalis, silo leachate, etc.) and liquids with abrasive (rubbing-off) substances (e.g., sand).

Electrical connection

  • The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fuse protection at least 6 A.
  • The motor is protected against overloading or blocking by the built-in thermal motor protection.
    In case of overheating, the overheating protection of the motor automatically switches off the pump and after cooling down, the pump switches on again automatically.

Mains connection

The pond pump you have purchased is already equipped with a protective contact plug. The pump is intended for connection to a 230 V~50 Hz earthed socket. Make sure that the socket is sufficiently fused (min. 6 A) and in perfect condition. Insert the pump plug into the socket; the pump is then ready for operation.

Notice:
Installation

Please position the pump underwater and ensure that no water can get into the socket.

Features

A new and clear design with variable frequency technology, low power consumption, high flow rate, large capacity, and good noise insulation, can be used in water and on land.

  • Wear-resistant, rust-proof, and durable ceramic shaft
  • Suitable for fresh and saltwater as it contains no copper
  • All components can be disassembled for easy cleaning.
  • With stepped hose nozzle, suitable for connecting hoses with different diameters.
  • Rotor blockage protection with immediate power cut-off in case of pump impeller blockage.

Technical data

Model| Item N2| Power supply| Power (W)| Max. head (m)| Output (ℓ⁄h)
---|---|---|---|---|---
JTP-1800| 51634| 230 V/5o Hz| 11| 2.| i800
JTP-2800| 51635| 18| 3.0| 2800
JTP-3800| 51636| 25| 4.| 3800
JTP-4800| 51637| 32| 5.| 4800
JTP-4000R| 51638| 25| 3.| 4000
JTP-5000R| 51639| 30| 4.| 5000
JTP-6000R| 51640| 40| 4.0| 6000
JTP-7000R| 51641| 50| 4.| 7000
JTP-8000R| 51642| 6o| 5.| 8000
JTP–w000R| 51643| 8o| 6.o| 10000
JTP-12000R| 51644| 100| 7.| 12000
SIT-14000R| 51645| 120| 7.0| 14000

Note!

wiltec 51634 SuperEco Filter Pump - Technical data

There are 2 types for connection to inlet and outlet:

wiltec 51634 SuperEco Filter Pump - outlet

Type 1:

  • Loosen the screw nut clockwise.
  • Connect the hose. 3.
  • Tighten the screw nut anticlockwise.

Type 2 (multi-stage connections):

  • Select the right size for the connection and cut off the smaller connections.
  • Connect the hose.

Explosion view, parts list, and operating instructions

JTP-1800–2800–3800–4800

wiltec 51634 SuperEco Filter Pump - operating
instructions

No Name No Name
1 Control valve 6 Bearing
2 Filter casing 7 Housing
3 Impeller cover 8 Rear cover
4 Rotor 9 Cable seal
5 O-sealing ring 10 Baseplate

wiltec 51634 SuperEco Filter Pump - operating instructions
1

  • Fig. 1: Set the flow rate using the rotary control.
  • Fig. 2: Open the filter housing by turning it in the direction of the arrow and then pulling it off.
  • Fig. 3: Move the snap lock on the base plate in the direction of the arrow.
  • Fig. 4: Remove the base plate.
  • Fig. 5: Turn the motor housing in the direction of the arrow and remove it.
  • Fig. 6: Pull the impeller and pump shaft out of the housing to clean or replace them.
  • Fig. 7: Make sure that the sealing ring is properly refitted before reassembling the pump.

JTP-4000R-5000R-6000R-7000R-10000R-12000R-14000R

wiltec 51634 SuperEco Filter Pump - operating instructions
2

No Name NO Name
1 Filter housing 6 Bearing
2 Control valve 7 Housing
3 Impeller cover 8 Back cover
4 Rotor 9 Baseplate
5 O-sealing ring

wiltec 51634 SuperEco Filter Pump - operating instructions
3

  • Fig. 1: Set the flow rate with the help of the control dial.
  • Fig. 2: Open the filter housing by turning it in the direction of the arrow and then pulling it off.
  • Fig. 3: Remove the control valve in the direction of the arrow.
  • Fig. 4: Move the snap lock on the base plate in the direction of the arrow.
  • Fig. 5: Loosen the base plate.
  • Fig. 6: Turn the motor housing in the direction of the arrow and remove it.
  • Fig. 7: Pull the impeller and the pump shaft out of the housing to clean or replace them.
  • Fig. 8: Make sure that the sealing ring is properly refitted before reassembling the pump.

Disposal regulations

EU guidelines regarding the disposal of scrap electric devices (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and devices.

All WilTec electric devices that fall under the WEEE regulations are labeled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed of with domestic waste.

The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEEregistration number DE45283704.


Disposal of used electrical and electronic devices (intended for use in the countries of the European Union and other European countries with a separate collection system for these devices). The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.

Material recycling helps reduce the consumption of raw materials.

Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.

Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler

Important notice:

The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this operation manual, require the written permission of WilTec Wildanger Technik GmbH.

© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals