DearBeauty PL Photon Dehairing Apparatus Hair Removal Device Instruction
Manual
Please read the instructions carefully before using them
Product Profile
The instrument uses photon cosmetic IPL technology and uses intense pulsed light to directly irradiate the skin to produce photobiochemical effects. On the one hand, collagen fibers and elastic fibers in the skin can be rearranged, skin elasticity can be restored, blood microcirculation can be improved, wrinkles can be cleared or alleviated; on the other hand, intense pulsed light can penetrate the skin and be preferentially absorbed by the pigments and capillaries in the tissues. Heat energy can make blood coagulate and pigments be heated without destroying normal skin tissues. Solution, thereby alleviating capillary expansion, removing spots, and can remove excess hair and so on.
Product summary
Skin test
BBefore using or after sunshine, skin test should be performed on each part of the treatment. Skin test is a necessary step. The purpose is to check the reaction of the skin to the treatment, and to determine the appropriate light intensity for each part of the treatment.
- Turn on the power supply of the instrument and select 1 file by default.
- Put the instrument on the skin, then press the flash and twist it to emit a flash.
- After completing the skin test, please wait 24 hours to check whether the skin has any reaction. If the skin reacts, please select the gear that will not cause skin reaction and use it in the subsequent hair removal course.
Suitable for skin color
Scope of application: Lip hair, axillary hair, body hair of limbs, frontal hair line and other hair that affect beauty; Painless hair removal is suitable for black hair and dark hair, not for white, gray and golden hair; Specifically refer to the following comparative card:
Skin color and hair contrast card
Matters needing attention
- People with skin sensory impairment should not use it.
- Allergic dermatitis, eczema and other skin diseases, allergic constitution, can not be used.
- Pregnant women, women during menstruation and lactation should not be used.
- Those who have been exposed to sunlight in the past two weeks should not be used.
Instructions
Pre-use preparation:
- Please remove the hair on the surface of the skin first, do a good job of skin pre-treatment, but before shaving, must wet the hair (using soap or shower gel bubble to wet the hair shaving effect is the best), otherwise “dry shaving” is easy to scrape the cuticle on the surface of the skin, causing allergies!
- Clean the skin, confirm that there is no obvious hair on its surface, completely dry, and no oily substances. Before using photon depilator, it is strictly forbidden to apply condensate, aloe vera gel and other products. Otherwise, it will lead to no light.
Product parameters
Product Name: IPL Photon Skin Rejuvenator
Instrument Principle: IPL Photon Beauty Technology
Implementation criteria: Q/SKT 009-2019
Net weight of product: 220g
Input voltage: DC12V~3A
Current: 5.8V
Wavelength: 570-1100 NM
Use steps
- Use cotton swab or dust-free cloth before use to dip in the luminous outlet and filter of medical alcohol cleaning instrument (if not dirty, it can be unclean). Keep the luminous outlet dry and reuse, otherwise it will affect the luminous output
- Plug in the power plug, press the switch button for 3 seconds, turn on and display 500 300 times and gear, fan rotation icon;
- The power switch key is also the gear key. Click on the “gear key” to select the appropriate gear. The display screen shows the energy gear, the smallest one, the largest five, and the gear can be cyclically adjusted.
- After the gear is adjusted, the light outlet of the device is completely attached to the skin part which needs to be depilated. At this time, when the display screen flickers, the light is lightly pressed out.
- Press 3 seconds long to enter or exit the automatic light-out mode. The three prisms on the screen light up to open the automatic light-out mode. Step 5 of the cycle, close to each part of the skin that needs to be depilated, flash once, move slowly, the depilated part repeats three times each time, but not three times in the same place, need to be depilated in the depilated area as a whole, and then repeat two times. (Because three consecutive polishes in the same place can burn easily.)
- After using depilator, selectively apply aloe vera gel (or not). After using the equipment, press the “power switch key” for 3 seconds to shut down, and cut off the power supply in time. After use, there may be small black spots attached to the lamp head filter. Wipe it clean with alcohol.
Reference table for course of treatment
1—4weeks| Use 2-3 times a week| More than 75% of hair begins to fall off
naturally
---|---|---
5—6weeks| 2 times a week| New hair shedding and growth inhibition
7—8weeks| 1 times a week| Hair thinning less, no longer rebound
More than 8 weeks| 1-2 times a week| Selective use (hair can be reused until
it is no longer long) depending on the hair growth status.
The course of hair removal is 3 times of irradiation. After irradiating the
hair
removal area once, do the second and third times. Do not give light in the
same place continuously.
The higher the gear is, the higher the energy is, the better the effect is. In
the early stage, it is suggested to use 1-2 gear first. After skin adaptation
in
the later stage, you can choose to use 3-5 gear. The interval of the course
of treatment depends on the growth rate of your personal hair, and the
situation of different parts of the body will be different.
Use completed
- The skin may be slightly reddened or tingling or warm. These reactions were completely harmless and soon disappeared.
- After using the instrument for 2 hours, you can apply emulsion, cream, fragrance agent, moisturizing product or cosmetics at the site of treatment. If the skin is tingling or redness after the end of the treatment, please wait for these conditions to disappear and then apply any product on the skin. If the skin is tingling after applying the product, please wash it with water.
Product Maintenance
- Turn off the power supply of the device immediately after use, unplug the plug and let the instrument cool down.
- Wet the cleaning soft cloth with a little water, then use it to clean the following parts: filter, skin contact film
- Store the instrument in a dust-free dry place with temperature ranging from 0 to 60 degrees.
Troubleshooting
Problem description | here may be reasons | Resolvent |
---|---|---|
Variable temperature and heat of device/ power adapter in use | This is a | |
normal phenomenon | No action is required |
I put the depilator on my skin and the indicator didn’t turn on, but the
cooling fan started to work.| The device needs to be reset| The device needs
to be reset
Odor emitted when using the device| Fittings or filters are too dirty| Please
clean the accessories carefully
| You haven’t completely removed the hair from the treatment area, which may
burn and produce a bad
smell.
| Please remove the hair on the skin surface before using this instrument
During the course of treatment, the skin feels more sensitive than usual and
the pain is intolerable when using the device| The light intensity setting you
use is too high| Please check the following to confirm whether the appropriate
lighting intensity setting is selected. If necessary, please lower the
setting。
| You haven’t completely removed the hair from
the treated area yet
| Before using this instrument, please remove the hair on the
skin surface
| The ultraviolet filter at the exit is damaged| Once the ultraviolet filter is damaged, do not continue to
use the device.
| If you use this device in unsuitable parts, your skin color is not suitable
for the treatment of this product.| Do not use this device on the following
parts: nipple, areola, labia minor, vagina, anus, nostril and inner ear. Male
users should not use the product on face or scrotum
Not satisfied with the results of the course of treatment| The light intensity
setting you use is too low| Next time, please choose a higher setting
| You didn’t shine again around the area you had previously treated.| Please
shine as close as possible to the previous position
| This device has no effect on the color of your hair.| If your hair is light
golden, golden or red, some treatments will not work. To successfully remove
all hair, you are advised to follow the recommended course of treatment. You
can shorten the treatment interval, but not more than once a day
| The frequency of using the instrument is insufficient. Your response
to IPL therapy may be slow
| Continuous use of the device for at least six months, as hair regrowth will still decrease during this period
Operational precautions
-
When operating, the eyes should not look directly at the flash of the light outlet or directly at the eyes.
-
After operation, mild redness of skin is a normal phenomenon, which can be cooled by ice or self-cooling.
-
When cleaning the dirt on the glass sheet in the luminous outlet, it is forbidden to spray alcohol directly on the luminous outlet.
-
When the instrument is operated, no gel like cosmetics, such as gelatin, are allowed on the skin, so as to avoid damaging the instrument.
-
Try not to eat sensitive food (such as spinach, rape, mustard, etc.) during operation.
-
The adjustment of energy gear is from weak to strong. Without damaging the skin, the higher the energy, the better the effect.
-
People with blacker skin may have delayed skin reactions, which can not increase energy because the immediate response is not obvious
-
Watch out for skin hydration and sunscreen after flashing.
-
Avoid ultraviolet radiation during use, do a good job of sunshade protection outside, avoid computer radiation as far as possible, apply isolation cream, sunscreen protective layer
-
Do not block the air intake and heat sink during use, so as not to affect
the heat dissipation. -
In the process of using the instrument, if there is hair or stain sticking to the plastic at the edge of the exit, it will cause the plastic at the edge of the exit to blacken or produce black spots, but it will not affect the performance and normal use of the instrument.
-
The “light-emitting tube” inside the luminous outlet of the instrument will appear different degrees of blackening on the inner wall of the tube in the later period of the prescribed life, which belongs to the normal aging process of the tube. The energy decay rate will not exceed the prescribed range in the life period and can be used normally.
-
The product does not have waterproof function. Please do not use it in the bathroom, in the shower or in other places where water may easily be touched.
-
If the product shell, window is broken or the instrument is improperly immersed, please send it back to the manufacturer for repair to determine whether it can be repaired and reused. If it is immersed in live condition, please unplug the power supply and contact the instrument first to ensure your safety.
-
Avoid storing in places with strong magnetic field and severe moisture and dust or high temperature.
-
Do not impact or knock the instrument strongly.
-
It is forbidden to use this product for other purposes than specified functions.